  "html_url": "https://licitia.com.mx/adjudicacion/aa-10-lau-010lau001-n-112-2025",
  "canonical": "https://licitia.com.mx/adjudicacion/aa-10-lau-010lau001-n-112-2025",
  "id": "356557036afe40dfb5298d357e11e9f8",
  "procedure_number": "AA-10-LAU-010LAU001-N-112-2025",
  "file_number": "E-2025-00067486",
  "title": "MANTENIMIENTO PREVENTIVO PARA EL EQUIPO ANALIZADOR TERMO GRAVIMÉTRICO 2025",
  "description": {
    "short": "No existen bienes alternativos o sustitutos, Único Oferente, Derechos exclusivos (patentes, licencias, derechos de autor u otros derechos exclusivos), o por obras de arte.",
    "detailed": "SERVICIO DE MANTENIMIENTO PREVENTIVO PARA EL EQUIPO ANALIZADOR TERMO GRAVIMÉTRICO, MODELO TGA 801, MARCA LECO, NÚMERO DE SERIE 53611, NÚMERO DE INVENTARIO 531010178083, PROPIEDAD DEL SERVICIO GEOLÓGICO MEXICANO.\n\nVISITA PUNTUAL PARA MANTENIMIENTO PREVENTIVO. NÚMERO DE PARTE SVC-INT-604\n\nALCANCE DEL SERVICIO DE MANTENIMIENTO A EQUIPO ANALIZADOR TERMO GRAVIMÉTRICO:\n\n-VERIFICAR MONITOR AMBIENTE Y ANOTAR VALORES FUERA DE TOLERANCIA\n-VERIFICAR TENSIONES AC Y DC\n-COMPROBAR PRESIONES DE ENTRADA DE GAS\n-HACER TEST DEL SISTEMA Y REGISTRAR RESULTADO\n-REVISAR VENTILADORES Y LIMPIAR LOS FILTROS\n-REVISAR GRIETAS DEL HORNO. COMPROBAR SI ESTÁ ALINEADO. REVISAR SI LA VELOCIDAD ES CORRECTA\n-REVISAR SI LA POSICIÓN DE PESADA Y LA VELOCIDAD EN POSICIÓN GIRO ES CORRECTA\n-LIMPIEZA INTERNA DEL INSTRUMENTO, RETIRAR CUALQUIER RESIDUO DEL INTERIOR DEL HORNO\n-REVISIÓN DEL ESTADO DE CONEXIONES DE GAS, VERIFICAR ORIENTACIÓN DE LAS TUBERÍAS LANZAS \n-VERIFICAR /AJUSTAR CENTRADO DEL PEDESTAL\n-REVISIÓN DE MANGUERAS Y CONEXIONES DEL INSTRUMENTO, EN CASO DE SER NECESARIO Y ESTAR DISPONIBLES SE REEMPLAZARÁN LOS SEGMENTOS DE TUBERÍAS REQUERIDAS\n-VERIFICACIÓN DE LAS CONDICIONES DE FUENTES DE VOLTAJE\n-REVISIÓN DE PARÁMETROS DEL MONITOR DE AMBIENTE Y SU CORRECCIÓN EN CASO DE QUE SE PUEDA REALIZAR CON LAS HERRAMIENTAS Y REFACCIONES DISPONIBLES\n-REVISAR ALTURA Y ORIENTACIÓN DEL TERMOPAR\n-VERIFIQUE LA POSICIÓN HOME DEL CARRUSEL. REALIZAR SU CALIBRACIÓN SI FUERA NECESARIO\n-RETIRE LA TUBERÍA DE LA SALIDA DEL EXTRACTOR EXTERNO Y REGISTRE EL CAUDAL\n-COMPROBAR EN LA CONFIGURACIÓN DEL SISTEMA LA VELOCIDAD DEL VENTILADOR SUPERIOR Y REGÍSTRELO\n-AJUSTE LOS FLUJOS DE SALIDA Y REALICE LA CALIBRACIÓN DEL FLUJO EN CHIMENEA SI FUERA NECESARIO\n-HACER TEST DEL SISTEMA Y REGISTRAR RESULTADO\n-CREAR UN MÉTODO DE PRUEBA USANDO LOS PARÁMETROS INDICADOS EN SERVICIO, EN EL MANUAL. ASEGURAR BIEN LOS PARÁMETROS. ANALICE LA PÉRDIDA DE PESO DEL OXALATO CÁLCICO COMO SE DESCRIBE EN LA SECCIÓN SERVICE - SYSTEM CHECK DEL MANUAL DE INSTRUC"
  },
  "lifecycle": {
    "section": "concluido",
    "source_status": "ADJUDICADO",
    "moved_at": null
  },
  "buyer": {
    "agency": "SERVICIO GEOLOGICO MEXICANO",
    "acronym": "SGM",
    "branch": "10 - ECONOMÍA",
    "buying_unit": "SUBGERENCIA DE ADQUISICIONES",
    "requesting_unit": "unidad requiriente data",
    "requesting_group": "SUBGERENCIA DE ADQUISICIONES",
    "entity": "SERVICIO GEOLÓGICO MEXICANO",
    "slug": "sgm",
    "unit_slug": "subgerencia-de-adquisiciones-010lau001"
  },
  "classification": {
    "procedure_type": "ADJUDICACIÓN DIRECTA",
    "contracting_type": "SERVICIOS",
    "publication_type": null,
    "character": "NACIONAL",
    "fiscal_year": 2025,
    "law": "LEY DE ADQUISICIONES, ARRENDAMIENTOS Y SERVICIOS DEL SECTOR PÚBLICO",
    "legal_basis_id": "153",
    "exception_basis": "Art. 54 fr. I",
    "internal_control_number": "PEDIDO NO. 01-00109-2025.",
    "supply_source_number": null
  },
  "schedule": {
    "published_at": "2025-08-13T23:58:08.000Z",
    "clarification_meeting_at": null,
    "clarification_questions_deadline_at": null,
    "clarification_responses_deadline_at": null,
    "bid_opening_at": null,
    "award_at": null,
    "estimated_contract_at": "2025-08-04T06:00:00.000Z",
    "site_visit_at": null,
    "estimated_work_start_at": null
  },
  "estimated_value": {
    "minimum": null,
    "maximum": null,
    "currency": "USD",
    "updated_at": null
  },
  "lots": [
    {
      "number": "1",
      "name": "PARTIDA SOLA",
      "description": "PARTIDA SOLA",
      "requirement_group_id": "1",
      "items": [
        {
          "number": "1",
          "cucop_code": "35701-0001",
          "specific_item_code": "35701",
          "cucop_description": "MAQUINARIA Y EQUIPO (MANTENIMIENTO Y REPARACION)",
          "description": "SERVICIO DE MANTENIMIENTO PREVENTIVO PARA EL EQUIPO ANALIZADOR TERMO GRAVIMÉTRICO, MODELO TGA 801, MARCA LECO, NÚMERO DE SERIE 53611, NÚMERO DE INVENTARIO 531010178083, PROPIEDAD DEL SERVICIO GEOLÓGICO MEXICANO.\n\nVISITA PUNTUAL PARA MANTENIMIENTO PREVENTIVO. NÚMERO DE PARTE SVC-INT-604\n\nALCANCE DEL SERVICIO DE MANTENIMIENTO A EQUIPO ANALIZADOR TERMO GRAVIMÉTRICO:\n\n-VERIFICAR MONITOR AMBIENTE Y ANOTAR VALORES FUERA DE TOLERANCIA\n-VERIFICAR TENSIONES AC Y DC\n-COMPROBAR PRESIONES DE ENTRADA DE GAS\n-HACER TEST DEL SISTEMA Y REGISTRAR RESULTADO\n-REVISAR VENTILADORES Y LIMPIAR LOS FILTROS\n-REVISAR GRIETAS DEL HORNO. COMPROBAR SI ESTÁ ALINEADO. REVISAR SI LA VELOCIDAD ES CORRECTA\n-REVISAR SI LA POSICIÓN DE PESADA Y LA VELOCIDAD EN POSICIÓN GIRO ES CORRECTA\n-LIMPIEZA INTERNA DEL INSTRUMENTO, RETIRAR CUALQUIER RESIDUO DEL INTERIOR DEL HORNO\n-REVISIÓN DEL ESTADO DE CONEXIONES DE GAS, VERIFICAR ORIENTACIÓN DE LAS TUBERÍAS LANZAS \n-VERIFICAR /AJUSTAR CENTRADO DEL PEDESTAL\n-REVISIÓN DE MANGUERAS Y CONEXIONES DEL INSTRUMENTO, EN CASO DE SER NECESARIO Y ESTAR DISPONIBLES SE REEMPLAZARÁN LOS SEGMENTOS DE TUBERÍAS REQUERIDAS\n-VERIFICACIÓN DE LAS CONDICIONES DE FUENTES DE VOLTAJE\n-REVISIÓN DE PARÁMETROS DEL MONITOR DE AMBIENTE Y SU CORRECCIÓN EN CASO DE QUE SE PUEDA REALIZAR CON LAS HERRAMIENTAS Y REFACCIONES DISPONIBLES\n-REVISAR ALTURA Y ORIENTACIÓN DEL TERMOPAR\n-VERIFIQUE LA POSICIÓN HOME DEL CARRUSEL. REALIZAR SU CALIBRACIÓN SI FUERA NECESARIO\n-RETIRE LA TUBERÍA DE LA SALIDA DEL EXTRACTOR EXTERNO Y REGISTRE EL CAUDAL\n-COMPROBAR EN LA CONFIGURACIÓN DEL SISTEMA LA VELOCIDAD DEL VENTILADOR SUPERIOR Y REGÍSTRELO\n-AJUSTE LOS FLUJOS DE SALIDA Y REALICE LA CALIBRACIÓN DEL FLUJO EN CHIMENEA SI FUERA NECESARIO\n-HACER TEST DEL SISTEMA Y REGISTRAR RESULTADO\n-CREAR UN MÉTODO DE PRUEBA USANDO LOS PARÁMETROS INDICADOS EN SERVICIO, EN EL MANUAL. ASEGURAR BIEN LOS PARÁMETROS. ANALICE LA PÉRDIDA DE PESO DEL OXALATO CÁLCICO COMO SE DESCRIBE EN LA SECCIÓN SERVICE - SYSTEM CHECK DEL MANUAL DE INSTRUC",
          "requested_quantity": "1",
          "minimum_quantity": "1",
          "maximum_quantity": null,
          "unit": "SERVICIO",
          "minimum_amount": null,
          "maximum_amount": null
        }
      ]
    }
  ],
  "awards": [
    {
      "id": "C-2025-00083845",
      "internal_reference": "PEDIDO NO. 01-00109-2025.",
      "title": "MANTENIMIENTO PREVENTIVO PARA EL EQUIPO ANALIZADOR TERMO GRAVIMÉTRICO 2025",
      "status": "PUBLICADO",
      "contractor": {
        "name": "LECO MEXICO S DE RL DE CV",
        "normalized_name": "LECO MEXICO",
        "rfc_type": null,
        "slug": "leco-mexico"
      },
      "contract_period": {
        "published_at": "2025-08-13T23:58:08.000Z",
        "starts_at": "2025-08-04T06:00:00.000Z",
        "ends_at": "2025-10-13T06:00:00.000Z"
      },
      "value": {
        "subtotal": "9283",
        "tax": "1485.28",
        "total": "10768.28",
        "maximum_subtotal": "0",
        "maximum_total": "0",
        "currency": "USD"
      },
      "open_contract_type": null,
      "quantity": null,
      "exercised_quantity": null,
      "participants": [],
      "line_items": [
        {
          "number": "0",
          "cucop_code": "35701-0001",
          "description": "SERVICIO DE MANTENIMIENTO PREVENTIVO PARA EL EQUIPO ANALIZADOR TERMO GRAVIMÉTRICO, MODELO TGA 801, MARCA LECO, NÚMERO DE SERIE 53611, NÚMERO DE INVENTARIO 531010178083, PROPIEDAD DEL SERVICIO GEOLÓGICO MEXICANO.\n\nVISITA PUNTUAL PARA MANTENIMIENTO PREVENTIVO. NÚMERO DE PARTE SVC-INT-604\n\nALCANCE DEL SERVICIO DE MANTENIMIENTO A EQUIPO ANALIZADOR TERMO GRAVIMÉTRICO:\n\n-VERIFICAR MONITOR AMBIENTE Y ANOTAR VALORES FUERA DE TOLERANCIA\n-VERIFICAR TENSIONES AC Y DC\n-COMPROBAR PRESIONES DE ENTRADA DE GAS\n-HACER TEST DEL SISTEMA Y REGISTRAR RESULTADO\n-REVISAR VENTILADORES Y LIMPIAR LOS FILTROS\n-REVISAR GRIETAS DEL HORNO. COMPROBAR SI ESTÁ ALINEADO. REVISAR SI LA VELOCIDAD ES CORRECTA\n-REVISAR SI LA POSICIÓN DE PESADA Y LA VELOCIDAD EN POSICIÓN GIRO ES CORRECTA\n-LIMPIEZA INTERNA DEL INSTRUMENTO, RETIRAR CUALQUIER RESIDUO DEL INTERIOR DEL HORNO\n-REVISIÓN DEL ESTADO DE CONEXIONES DE GAS, VERIFICAR ORIENTACIÓN DE LAS TUBERÍAS LANZAS \n-VERIFICAR /AJUSTAR CENTRADO DEL PEDESTAL\n-REVISIÓN DE MANGUERAS Y CONEXIONES DEL INSTRUMENTO, EN CASO DE SER NECESARIO Y ESTAR DISPONIBLES SE REEMPLAZARÁN LOS SEGMENTOS DE TUBERÍAS REQUERIDAS\n-VERIFICACIÓN DE LAS CONDICIONES DE FUENTES DE VOLTAJE\n-REVISIÓN DE PARÁMETROS DEL MONITOR DE AMBIENTE Y SU CORRECCIÓN EN CASO DE QUE SE PUEDA REALIZAR CON LAS HERRAMIENTAS Y REFACCIONES DISPONIBLES\n-REVISAR ALTURA Y ORIENTACIÓN DEL TERMOPAR\n-VERIFIQUE LA POSICIÓN HOME DEL CARRUSEL. REALIZAR SU CALIBRACIÓN SI FUERA NECESARIO\n-RETIRE LA TUBERÍA DE LA SALIDA DEL EXTRACTOR EXTERNO Y REGISTRE EL CAUDAL\n-COMPROBAR EN LA CONFIGURACIÓN DEL SISTEMA LA VELOCIDAD DEL VENTILADOR SUPERIOR Y REGÍSTRELO\n-AJUSTE LOS FLUJOS DE SALIDA Y REALICE LA CALIBRACIÓN DEL FLUJO EN CHIMENEA SI FUERA NECESARIO\n-HACER TEST DEL SISTEMA Y REGISTRAR RESULTADO\n-CREAR UN MÉTODO DE PRUEBA USANDO LOS PARÁMETROS INDICADOS EN SERVICIO, EN EL MANUAL. ASEGURAR BIEN LOS PARÁMETROS. ANALICE LA PÉRDIDA DE PESO DEL OXALATO CÁLCICO COMO SE DESCRIBE EN LA SECCIÓN SERVICE - SYSTEM CHECK DEL MANUAL DE INSTRUC",
          "unit": "SERVICIO",
          "requested_quantity": "1",
          "awarded_quantity": null,
          "unit_price": "9283",
          "subtotal": "9283",
          "tax": "1485.28",
          "other_taxes": null,
          "total": "10768.28"
        }
      ]
    }
  ],
  "documents": [
    {
      "id": null,
      "annex_number": 1,
      "document_type": null,
      "description": "JUSTIFICACIÓN DE EXCEPCIÓN",
      "filename": "JUST PED 109.pdf",
      "availability": "available",
      "size_bytes": "1687040",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-03T13:41:32.770Z",
      "updated_at": "2025-12-03T13:41:32.771Z"
    },
    {
      "id": null,
      "annex_number": 1,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A TEC PED 109.pdf",
      "availability": "available",
      "size_bytes": "3651733",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-03T13:41:46.013Z",
      "updated_at": "2025-12-03T13:41:46.014Z"
    },
    {
      "id": null,
      "annex_number": 4,
      "document_type": null,
      "description": "OFICIO DE ADJUDICACIÓN",
      "filename": "OF DAF-366-2025.pdf",
      "availability": "available",
      "size_bytes": "85262",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-03T13:41:48.173Z",
      "updated_at": "2025-12-03T13:41:48.174Z"
    }
  ],
  "alternates": [],
  "similar": [
    {
      "numero_procedimiento": "aa-10-lau-010lau001-n-93-2023",
      "nombre_procedimiento": "SERVICIO DE MANTENIMIENTO PREVENTIVO PARA EL EQUIPO ANALIZADOR TERMO GRAVIMÉTRIC",
      "dependencia": "SERVICIO GEOLOGICO MEXICANO",
      "siglas": "SGM",
      "score": 0.07398384368515787
    },
    {
      "numero_procedimiento": "aa-10-lau-010lau001-n-72-2024",
      "nombre_procedimiento": "SERVICIO DE MANTENIMIENTO PREVENTIVO PARA EL EQUIPO ANALIZADOR TERMOGRAVIMÉTRICO",
      "dependencia": "SERVICIO GEOLOGICO MEXICANO",
      "siglas": "SGM",
      "score": 0.07970452308654785
    },
    {
      "numero_procedimiento": "aa-11-l4j-011l4j996-n-32-2024",
      "nombre_procedimiento": "CONTRATO DE SERVICIO PARA INSTRUMENTO ANALITICO LECO",
      "dependencia": "CINVESTAV",
      "siglas": "CINVESTAV",
      "score": 0.16476886482424202
    },
    {
      "numero_procedimiento": "aa-11-l4j-011l4j996-n-41-2023",
      "nombre_procedimiento": "CONTRATO DE SERVICIO PARA INSTRUMENTO ANALITICO LECO CS-230",
      "dependencia": "CINVESTAV",
      "siglas": "CINVESTAV",
      "score": 0.17208883679177833
    },
    {
      "numero_procedimiento": "aa-11-l4j-011l4j996-n-38-2025",
      "nombre_procedimiento": "MANTENIMIENTO PARA INSTRUMENTO ANALITICO LECO CS-230",
      "dependencia": "CINVESTAV",
      "siglas": "CINVESTAV",
      "score": 0.17913711071014404
    },
    {
      "numero_procedimiento": "aa-11-l4j-011l4j996-n-52-2024",
      "nombre_procedimiento": "SERVICIO DE MANTENIMIENTO PREVENTIVO PARA EQUIPO FLASH SMART ANALIZADOR",
      "dependencia": "CINVESTAV",
      "siglas": "CINVESTAV",
      "score": 0.21377980709075928
    }
  ]
}