  "html_url": "https://licitia.com.mx/adjudicacion/aa-12-m7b-012m7b997-i-4-2023",
  "canonical": "https://licitia.com.mx/adjudicacion/aa-12-m7b-012m7b997-i-4-2023",
  "id": "f3c73d8c68c7462e8be5eb5dba2d327e",
  "procedure_number": "AA-12-M7B-012M7B997-I-4-2023",
  "file_number": "E-2023-00000176",
  "title": "ADQUISICIÓN DE EQUIPO MEDICO, EN COAHUILA (ANGIÓGRAFOS)",
  "description": {
    "short": "Se haya declarado desierta una licitación pública, siempre que se mantengan los requisitos establecidos en la convocatoria.",
    "detailed": "ADQUISICIÓN DE EQUIPO MEDICO, EN COAHUILA (ANGIÓGRAFOS)"
  },
  "lifecycle": {
    "section": "concluido",
    "source_status": "ADJUDICADO",
    "moved_at": null
  },
  "buyer": {
    "agency": "INSTITUTO DE SALUD PARA EL BIENESTAR",
    "acronym": "INSABI",
    "branch": "12 - SALUD",
    "buying_unit": "COORDINACION DE OPTIMIZACION Y PROCESOS DEL ABASTO",
    "requesting_unit": "unidad requiriente data",
    "requesting_group": "COORDINACION DE OPTIMIZACION Y PROCESOS DEL ABASTO",
    "entity": "INSTITUTO DE SALUD PARA EL BIENESTAR",
    "slug": "insabi",
    "unit_slug": "coordinacion-de-optimizacion-y-procesos-del-abasto-012m7b997"
  },
  "classification": {
    "procedure_type": "ADJUDICACIÓN DIRECTA",
    "contracting_type": "ADQUISICIONES",
    "publication_type": null,
    "character": "INTERNACIONAL ABIERTO",
    "fiscal_year": 2023,
    "law": "LEY DE ADQUISICIONES, ARRENDAMIENTOS Y SERVICIOS DEL SECTOR PÚBLICO",
    "legal_basis_id": "28",
    "exception_basis": "Art. 41 fr. VII",
    "internal_control_number": "ADQUISICIÓN DE EQUIPO MEDICO, EN COAHUILA (ANGIÓGRAFOS)",
    "supply_source_number": null
  },
  "schedule": {
    "published_at": "2023-07-31T16:50:15.000Z",
    "clarification_meeting_at": null,
    "clarification_questions_deadline_at": null,
    "clarification_responses_deadline_at": null,
    "bid_opening_at": null,
    "award_at": null,
    "estimated_contract_at": "2023-01-09T06:00:00.000Z",
    "site_visit_at": null,
    "estimated_work_start_at": null
  },
  "estimated_value": {
    "minimum": null,
    "maximum": null,
    "currency": "MXN",
    "updated_at": null
  },
  "lots": [
    {
      "number": "1",
      "name": "PARTIDA SOLA",
      "description": "PARTIDA SOLA",
      "requirement_group_id": "1",
      "items": [
        {
          "number": "1",
          "cucop_code": "53101-1330",
          "specific_item_code": "53101",
          "cucop_description": "531.055.0024 ANGIOGRAFO ARCO MONOPLANAR. SISTEMA DE RAYOS \"\"X\"\" PARA ESTUDIOS DIAGNOSTICOS Y TERAPEUTICOS. CON LAS SIGUIENTES CARACTERISTICAS SELECCIONABLES DE ACUERDO A LAS NECESIDADES DE LAS UNIDADES MEDICAS: INTEGRADO POR UN ARCO AL PISO O AL TECHO CON LAS SIGUIENTES CARACTERISTICAS DE ACUERDO A APLICACIONES DIAGNOSTICAS Y DE TRATAMIENTO: ROTACION Y ANGULACION MOVIMIENTO AXIAL MANUAL O MOTORIZADO DEL INTENSIFICADOR DE IMAGEN O PANTALLA PLANA PARA AJUSTAR LA DISTANCIA FOCO-PACIENTE DISTANCIA VARIABLE ENTRE EL FOCO Y LA PANTALLA DEL INTENSIFICADOR DE IMAGEN PROFUNDIDAD DEL BRAZO MOVIMIENTOS MOTORIZADOS DEL ARCO DE VELOCIDAD VARIABLE CON ROTACION Y ANGULACION INTENSIFICADOR DE IMAGEN O PANTALLA PLANA CON PROTECCION CONTRA O ANTICOLISION. MESA PARA EL PACIENTE: CON MOVIMIENTO LONGITUDINAL Y TRANSVERSAL AJUSTE DE LA ALTURA CARGA MAXIMA DEL PACIENTE. SISTEMA DE RAYOS \"\"X : GENERADOR DE RAYOS \"\"X\"\" DE ALTA FRECUENCIA CONTROLADO POR MICROPROCESADOR CORRIENTE DEL GENERADOR TUBO DE RAYOS \"\"X\"\" CON DOS PUNTOS FOCALES CON CAPACIDAD DE ALMACENAMIENTO DE CALOR DEL ANODO Y CAPACIDAD DE DISIPACION DE CALOR POSICION MANUAL O AUTOMATICA. FILTRACION DE LA RADIACION. SISTEMA DE ADQUISICION: PROGRAMAS PARA FLUOROSCOPIA CON CONTROL DE DOSIS PROCESAMIENTO DIGITAL Y SELECCION DE FILTROS DE RAYOS \"\"X\"\" A IMPULSOS PARA FLUOROSCOPIA PULSADA. CADENA DIGITAL DE TV CON SALIDA DIGITAL CUATRO MONITORES DE ALTA RESOLUCION PANTALLA ANTIRREFLEJANTE CON ADAPTACION AUTOMATICA DEL BRILLO Y CONTRASTE A LAS CONDICIONES DE LA SALA. SUSPENSION A TECHO PARA COLOCACION DE MONITORES. MODULO O CONSOLA DE DESPLIEGUE QUE APORTE INFORMACION SOBRE: EL ESTADO DE ROTACION/ANGULACION DEL BRAZO MENSAJES DEL SISTEMA EL ESTADO DE CARGA DE LOS TUBOS. DE RAYOS \"\"X\"\" LA MODALIDAD FLUORO SELECCIONADA Y CAMPO DE LOS INTENSIFICADORES DE IMAGEN O CAMPOS O AREAS DE VISION O IMAGEN. MODULO PARA LECTURA DE LA TASA DE DOSIS DE RADIACION EN CGY/CM2/SEG Y CRONOMETRO. ESTACION DE TRABAJO CON MONITOR TECLADO ALFANUMERICO Y MOUSE. CAPACIDAD PARA ADQUISICION Y ALMACENAMIENTO DE SEÑALES FISIOLOGICAS Y SU DESPLIEGUE. PROCESAMIENTO DE IMAGEN: MATRICES Y VELOCIDADES DE ADQUISICION Y CON SUSTRACCION DIGITAL EN TIEMPO REAL.",
          "description": "531.055.0024 ANGIOGRAFO ARCO MONOPLANAR. SISTEMA DE RAYOS \"\"X\"\" PARA ESTUDIOS DIAGNOSTICOS Y TERAPEUTICOS. CON LAS SIGUIENTES CARACTERISTICAS SELECCIONABLES DE ACUERDO A LAS NECESIDADES DE LAS UNIDADES MEDICAS: INTEGRADO POR UN ARCO AL PISO O AL TECHO CON LAS SIGUIENTES CARACTERISTICAS DE ACUERDO A APLICACIONES DIAGNOSTICAS Y DE TRATAMIENTO: ROTACION Y ANGULACION MOVIMIENTO AXIAL MANUAL O MOTORIZADO DEL INTENSIFICADOR DE IMAGEN O PANTALLA PLANA PARA AJUSTAR LA DISTANCIA FOCO-PACIENTE DISTANCIA VARIABLE ENTRE EL FOCO Y LA PANTALLA DEL INTENSIFICADOR DE IMAGEN PROFUNDIDAD DEL BRAZO MOVIMIENTOS MOTORIZADOS DEL ARCO DE VELOCIDAD VARIABLE CON ROTACION Y ANGULACION INTENSIFICADOR DE IMAGEN O PANTALLA PLANA CON PROTECCION CONTRA O ANTICOLISION. MESA PARA EL PACIENTE: CON MOVIMIENTO LONGITUDINAL Y TRANSVERSAL AJUSTE DE LA ALTURA CARGA MAXIMA DEL PACIENTE. SISTEMA DE RAYOS \"\"X : GENERADOR DE RAYOS \"\"X\"\" DE ALTA FRECUENCIA CONTROLADO POR MICROPROCESADOR CORRIENTE DEL GENERADOR TUBO DE RAYOS \"\"X\"\" CON DOS PUNTOS FOCALES CON CAPACIDAD DE ALMACENAMIENTO DE CALOR DEL ANODO Y CAPACIDAD DE DISIPACION DE CALOR POSICION MANUAL O AUTOMATICA. FILTRACION DE LA RADIACION. SISTEMA DE ADQUISICION: PROGRAMAS PARA FLUOROSCOPIA CON CONTROL DE DOSIS PROCESAMIENTO DIGITAL Y SELECCION DE FILTROS DE RAYOS \"\"X\"\" A IMPULSOS PARA FLUOROSCOPIA PULSADA. CADENA DIGITAL DE TV CON SALIDA DIGITAL CUATRO MONITORES DE ALTA RESOLUCION PANTALLA ANTIRREFLEJANTE CON ADAPTACION AUTOMATICA DEL BRILLO Y CONTRASTE A LAS CONDICIONES DE LA SALA. SUSPENSION A TECHO PARA COLOCACION DE MONITORES. MODULO O CONSOLA DE DESPLIEGUE QUE APORTE INFORMACION SOBRE: EL ESTADO DE ROTACION/ANGULACION DEL BRAZO MENSAJES DEL SISTEMA EL ESTADO DE CARGA DE LOS TUBOS. DE RAYOS \"\"X\"\" LA MODALIDAD FLUORO SELECCIONADA Y CAMPO DE LOS INTENSIFICADORES DE IMAGEN O CAMPOS O AREAS DE VISION O IMAGEN. MODULO PARA LECTURA DE LA TASA DE DOSIS DE RADIACION EN CGY/CM2/SEG Y CRONOMETRO. ESTACION DE TRABAJO CON MONITOR TECLADO ALFANUMERICO Y MOUSE. CA",
          "requested_quantity": "2",
          "minimum_quantity": "2",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        }
      ]
    }
  ],
  "awards": [
    {
      "id": "C-2023-00083406",
      "internal_reference": "AA-I-4-EQANGIO-INSABI-01-2023",
      "title": "ADQUISICIÓN DE EQUIPO MEDICO, EN COAHUILA (ANGIÓGRAFOS)",
      "status": "PUBLICADO",
      "contractor": {
        "name": "TECNOLOGIAS EOS MEDICAL SA DE CV",
        "normalized_name": "TECNOLOGIAS EOS MEDICAL",
        "rfc_type": null,
        "slug": "tecnologias-eos-medical"
      },
      "contract_period": {
        "published_at": "2023-07-31T16:50:15.000Z",
        "starts_at": "2023-01-09T06:00:00.000Z",
        "ends_at": "2023-09-18T06:00:00.000Z"
      },
      "value": {
        "subtotal": "81286738",
        "tax": "0",
        "total": "81286738",
        "maximum_subtotal": "0",
        "maximum_total": "0",
        "currency": "MXN"
      },
      "open_contract_type": null,
      "quantity": null,
      "exercised_quantity": null,
      "participants": [],
      "line_items": [
        {
          "number": "0",
          "cucop_code": "53101-1330",
          "description": "531.055.0024 ANGIOGRAFO ARCO MONOPLANAR. SISTEMA DE RAYOS \"\"X\"\" PARA ESTUDIOS DIAGNOSTICOS Y TERAPEUTICOS. CON LAS SIGUIENTES CARACTERISTICAS SELECCIONABLES DE ACUERDO A LAS NECESIDADES DE LAS UNIDADES MEDICAS: INTEGRADO POR UN ARCO AL PISO O AL TECHO CON LAS SIGUIENTES CARACTERISTICAS DE ACUERDO A APLICACIONES DIAGNOSTICAS Y DE TRATAMIENTO: ROTACION Y ANGULACION MOVIMIENTO AXIAL MANUAL O MOTORIZADO DEL INTENSIFICADOR DE IMAGEN O PANTALLA PLANA PARA AJUSTAR LA DISTANCIA FOCO-PACIENTE DISTANCIA VARIABLE ENTRE EL FOCO Y LA PANTALLA DEL INTENSIFICADOR DE IMAGEN PROFUNDIDAD DEL BRAZO MOVIMIENTOS MOTORIZADOS DEL ARCO DE VELOCIDAD VARIABLE CON ROTACION Y ANGULACION INTENSIFICADOR DE IMAGEN O PANTALLA PLANA CON PROTECCION CONTRA O ANTICOLISION. MESA PARA EL PACIENTE: CON MOVIMIENTO LONGITUDINAL Y TRANSVERSAL AJUSTE DE LA ALTURA CARGA MAXIMA DEL PACIENTE. SISTEMA DE RAYOS \"\"X : GENERADOR DE RAYOS \"\"X\"\" DE ALTA FRECUENCIA CONTROLADO POR MICROPROCESADOR CORRIENTE DEL GENERADOR TUBO DE RAYOS \"\"X\"\" CON DOS PUNTOS FOCALES CON CAPACIDAD DE ALMACENAMIENTO DE CALOR DEL ANODO Y CAPACIDAD DE DISIPACION DE CALOR POSICION MANUAL O AUTOMATICA. FILTRACION DE LA RADIACION. SISTEMA DE ADQUISICION: PROGRAMAS PARA FLUOROSCOPIA CON CONTROL DE DOSIS PROCESAMIENTO DIGITAL Y SELECCION DE FILTROS DE RAYOS \"\"X\"\" A IMPULSOS PARA FLUOROSCOPIA PULSADA. CADENA DIGITAL DE TV CON SALIDA DIGITAL CUATRO MONITORES DE ALTA RESOLUCION PANTALLA ANTIRREFLEJANTE CON ADAPTACION AUTOMATICA DEL BRILLO Y CONTRASTE A LAS CONDICIONES DE LA SALA. SUSPENSION A TECHO PARA COLOCACION DE MONITORES. MODULO O CONSOLA DE DESPLIEGUE QUE APORTE INFORMACION SOBRE: EL ESTADO DE ROTACION/ANGULACION DEL BRAZO MENSAJES DEL SISTEMA EL ESTADO DE CARGA DE LOS TUBOS. DE RAYOS \"\"X\"\" LA MODALIDAD FLUORO SELECCIONADA Y CAMPO DE LOS INTENSIFICADORES DE IMAGEN O CAMPOS O AREAS DE VISION O IMAGEN. MODULO PARA LECTURA DE LA TASA DE DOSIS DE RADIACION EN CGY/CM2/SEG Y CRONOMETRO. ESTACION DE TRABAJO CON MONITOR TECLADO ALFANUMERICO Y MOUSE. CA",
          "unit": "PIEZA",
          "requested_quantity": "2",
          "awarded_quantity": null,
          "unit_price": "40643369",
          "subtotal": "81286738",
          "tax": null,
          "other_taxes": null,
          "total": "81286738"
        }
      ]
    }
  ],
  "documents": [
    {
      "id": null,
      "annex_number": 1,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "01. ANEXO COA.PDF",
      "availability": "available",
      "size_bytes": "14383506",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-07T20:03:44.590Z",
      "updated_at": "2025-12-07T20:03:44.591Z"
    },
    {
      "id": null,
      "annex_number": 1,
      "document_type": null,
      "description": "JUSTIFICACIÓN DE EXCEPCIÓN",
      "filename": "12. MEMO 004 Justificación contratación.pdf",
      "availability": "available",
      "size_bytes": "3709280",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-07T20:03:48.104Z",
      "updated_at": "2025-12-07T20:03:48.106Z"
    },
    {
      "id": null,
      "annex_number": 4,
      "document_type": null,
      "description": "OFICIO DE ADJUDICACIÓN",
      "filename": "OFICIO INSABI-UCNAMEM-COPA-069-2023.PDF",
      "availability": "available",
      "size_bytes": "58721",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-07T20:03:49.322Z",
      "updated_at": "2025-12-07T20:03:49.323Z"
    }
  ],
  "alternates": [],
  "similar": [
    {
      "numero_procedimiento": "aa-50-gyr-050gyr022-t-291-2024",
      "nombre_procedimiento": "ADQUISICIÓN DE EQUIPAMIENTO ASOCIADO A OBRA",
      "dependencia": "INSTITUTO MEXICANO DEL SEGURO SOCIAL",
      "siglas": "IMSS",
      "score": 0.0491053403490308
    },
    {
      "numero_procedimiento": "aa-50-gyr-050gyr022-t-158-2024",
      "nombre_procedimiento": "EQUIPAMIENTO ASOCIADO A OBRA",
      "dependencia": "INSTITUTO MEXICANO DEL SEGURO SOCIAL",
      "siglas": "IMSS",
      "score": 0.05431411155886079
    },
    {
      "numero_procedimiento": "aa-50-gyr-050gyr022-t-145-2024",
      "nombre_procedimiento": "EQUIPAMIENTO ASOCIADO A OBRA",
      "dependencia": "IMSS",
      "siglas": "IMSS",
      "score": 0.0801551890280714
    },
    {
      "numero_procedimiento": "aa-07-110-007000999-t-669-2024",
      "nombre_procedimiento": "CONSTRUCCION, AMPLIACION Y ADECUACION DEL HOSPITAL CENTRAL MILITAR (ANGIOGRAFO)",
      "dependencia": "SEDENA",
      "siglas": "SEDENA",
      "score": 0.08617973327636719
    },
    {
      "numero_procedimiento": "aa-07-110-007000999-t-748-2024",
      "nombre_procedimiento": "HOSPITAL GENERAL AGUSTIN O HORAN EN MERIDA, EQUIPO MED. ESPECIALIDADES PTDAS DES",
      "dependencia": "SECRETARIA DE LA DEFENSA NACIONAL",
      "siglas": "SEDENA",
      "score": 0.09761703596216498
    },
    {
      "numero_procedimiento": "aa-80-u88-921002997-n-35-2023",
      "nombre_procedimiento": "EQUIPO MÉDICO ANGIOGRAFO ARCO MONOPLANAR",
      "dependencia": "SECRETARÍA DE PLANEACIÓN, FINANZAS Y ADMINISTRACIÓN (PUE)",
      "siglas": "SAPUEBLA",
      "score": 0.13829905619019456
    }
  ]
}