  "procedure_number": "AA-18-T0O-018T0O002-N-22-2026",
  "file_number": "E-2026-00085304",
  "title": "SERVICIO DE MANTENIMIENTO PREVENTIVO A DOS VISCOSIMETROS",
  "description": {
    "short": "Adjudicación directa autorizada por el TUAF o equivalente, cuando la operación corresponde al monto de una invitación a cuando menos tres personas.",
    "detailed": "SERVICIO DE MANTENIMIENTO PREVENTIVO DE LOS SIGUIENTES SISTEMAS EXPERIMENTALES:\n\n1)\tVISCOSÍMETRO DE ALTA PRESIÓN, MARCA PSL, MODELO HPHT.\n2)\tVISCOSÍMETRO DE ALTA PRESIÓN, MARCA PSL, MODELO HPHT."
  },
  "lifecycle": {
    "section": "concluido",
    "source_status": "ADJUDICADO",
    "moved_at": null
  },
  "buyer": {
    "agency": "INSTITUTO MEXICANO DEL PETROLEO",
    "acronym": "IMP",
    "branch": "18 - ENERGÍA",
    "buying_unit": "MODULO DE MATERIALES Y SERVICIOS EN VERACRUZ",
    "requesting_unit": "unidad requiriente data",
    "requesting_group": "MODULO DE MATERIALES Y SERVICIOS EN VERACRUZ",
    "entity": "instituto mexicano del petroleo",
    "slug": "imp",
    "unit_slug": "modulo-de-materiales-y-servicios-en-veracruz-018t0o002"
  },
  "classification": {
    "procedure_type": "ADJUDICACIÓN DIRECTA",
    "contracting_type": "SERVICIOS",
    "publication_type": null,
    "character": "NACIONAL",
    "fiscal_year": 2026,
    "law": "LEY DE ADQUISICIONES, ARRENDAMIENTOS Y SERVICIOS DEL SECTOR PÚBLICO",
    "legal_basis_id": "266",
    "exception_basis": "Art. 55 párrafo segundo",
    "internal_control_number": "1202600375",
    "supply_source_number": null
  },
  "schedule": {
    "published_at": "2026-07-21T17:36:51.000Z",
    "clarification_meeting_at": null,
    "clarification_questions_deadline_at": null,
    "clarification_responses_deadline_at": null,
    "bid_opening_at": null,
    "award_at": null,
    "estimated_contract_at": "2026-07-29T06:00:00.000Z",
    "site_visit_at": null,
    "estimated_work_start_at": null
  },
  "estimated_value": {
    "minimum": null,
    "maximum": null,
    "currency": "MXN",
    "updated_at": null
  },
  "lots": [
    {
      "number": "1",
      "name": "PARTIDA SOLA",
      "description": "PARTIDA SOLA",
      "requirement_group_id": "1",
      "items": [
        {
          "number": "1",
          "cucop_code": "35401-0003",
          "specific_item_code": "35401",
          "cucop_description": "SERVICIOS DE MANTENIMIENTO DE EQUIPO E INSTRUMENTAL MEDICO",
          "description": "PARTIDA 1: VISCOSÍMETRO DE ALTA PRESIÓN, MARCA PSL, MODELO HPHT.\n\nSERVICIO DE MANTENIMIENTO PREVENTIVO, AL SIGUIENTE EQUIPO CON INVENTARIO SAP, QUE INTEGRAN EL SISTEMA:\n\nNOMBRE DEL EQUIPO EN SAP\tINVENTARIO\tSERIE\tFUNCIÓN\nVISCOSÍMETRO DE ALTA PRESIÓN\t0172066\t1624003\tMEDICIÓN\n\nA CONTINUACIÓN, SE DESCRIBEN LAS ACTIVIDADES QUE DEBE REALIZAR EL PROVEEDOR A CADA UNO DE LOS COMPONENTES:\n\nA).\tREVISIÓN, LIMPIEZA Y AJUSTES DEL SISTEMA DEL BAÑO TÉRMICO MARCA THERMOFISHER SCIENTIFIC, QUE FORMA PARTE INTEGRAL DEL SISTEMA EXPERIMENTAL DEL VISCOSÍMETRO PARA ALTA PRESIÓN Y TEMPERATURA MARCA PSL MODELO HAAKE A25, NÚMERO DE SERIE: 0152717101170123. INCLUIR CAMBIO DEL FLUIDO TÉRMICO THERMAL H10 (10 LITROS) Y SUSTITUCIÓN DE LAS DOS MANGUERAS PARA EL CHILLER DE 2 METROS.\nB).\tREVISIÓN, LIMPIEZA, AJUSTES Y CALIBRACIÓN DEL VISCOSÍMETRO HPV VISCOTESTER 550 MARCA PSL, EL CUAL INCLUYE EL MÓDULO DE CELDA AUTOCLAVE, ABRAZADERA DE BLOQUEO Y VÁLVULA DE SEGURIDAD, VÁLVULAS, TUBERÍAS Y CONEXIONES DEL VISCOSÍMETRO DE ALTA PRESIÓN (20 KPSI). INCLUIR LA SUSTITUCIÓN DEL JUEGO DE ORINGS.\nC).\tREVISIÓN, LIMPIEZA, VERIFICACIÓN, ALINEACIÓN Y AJUSTE DEL MÓDULO DE MEDICIÓN, LO CUAL COMPRENDE LA BRECHA DE MEDICIÓN, EL EJE EN LA TAPA DE LA AUTOCLAVE Y EL CUERPO DE ROTACIÓN DEL EQUIPO. INCLUIR SUSTITUCIÓN DE LA GEOMETRÍA NV CILINDRO CONCÉNTRICO (PARA FLUIDOS DE 2 HASTA 2000 MPAS) QUE SE ENCUENTRA EN MAL ESTADO.\nD).\tREVISIÓN Y AJUSTE DEL SISTEMA DE ADQUISICIÓN DE DATOS, ASÍ COMO LA VERIFICACIÓN DEL CORRECTO FUNCIONAMIENTO DE LA COMUNICACIÓN EQUIPO-PC. REVISAR Y ARREGLAR FALLA EN COMUNICACIÓN CON EL SENSOR DE PRESIÓN EN SOFTWARE.\nE).\tREEMPLAZO DE COMPONENTES DAÑADOS. INCLUIR UNA FLECHA ROTOR PARA ACOPLAMIENTO DE GEOMETRÍAS.\nF).\tVERIFICACIÓN DE MEDICIONES DEL SENSOR DE PRESIÓN, TEMPERATURA Y ESFUERZO DE CORTE.\nG).\tPRUEBAS DE FUNCIONAMIENTO DEL EQUIPO CON ESTÁNDARES CERTIFICADOS. INCLUIR 3 ESTÁNDARES PARA LOS INTERVALOS DE VISCOSIDAD DE MENORES A 100 CP, DE 100 A 1,000 CP Y MAYORES A 1,000 CP.\nH).\tPRUEBA DE FUNCIONAM",
          "requested_quantity": "1",
          "minimum_quantity": "1",
          "maximum_quantity": null,
          "unit": "SERVICIO",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "2",
          "cucop_code": "35401-0003",
          "specific_item_code": "35401",
          "cucop_description": "SERVICIOS DE MANTENIMIENTO DE EQUIPO E INSTRUMENTAL MEDICO",
          "description": "PARTIDA 2: VISCOSÍMETRO DE ALTA PRESIÓN, MARCA PSL, MODELO HPHT.\n\nSERVICIO DE MANTENIMIENTO PREVENTIVO, AL SIGUIENTE EQUIPO CON INVENTARIO SAP, QUE INTEGRAN EL SISTEMA:\n\nNOMBRE DEL EQUIPO EN SAP\tINVENTARIO\tSERIE\tFUNCIÓN\nVISCOSÍMETRO DE ALTA PRESIÓN\t0172067\t16224002\tMEDICIÓN\n\nA CONTINUACIÓN, SE DESCRIBEN LAS ACTIVIDADES QUE DEBE REALIZAR EL PROVEEDOR A CADA UNO DE LOS COMPONENTES:\n\nA).\tREVISIÓN, LIMPIEZA Y AJUSTES DEL SISTEMA DEL BAÑO TÉRMICO MARCA THERMOFISHER SCIENTIFIC, QUE FORMA PARTE INTEGRAL DEL SISTEMA EXPERIMENTAL DEL VISCOSÍMETRO DE ALTA PRESIÓN Y TEMPERATURA MARCA PSL, MODELO HAAKE A25, NÚMERO DE SERIE: 1152720101170124. INCLUIR CAMBIO DE FLUIDO TÉRMICO THERMAL H10 (10 LITROS) Y SUSTITUCIÓN DE LAS DOS MANGUERAS PARA EL CHILLER DE 2 METROS.\nB).\tREVISIÓN, LIMPIEZA, AJUSTES Y CALIBRACIÓN DEL VISCOSÍMETRO HPV VISCOTESTER 550 MARCA PSL, INCLUYE VÁLVULAS, TUBERÍAS Y CONEXIONES DEL VISCOSÍMETRO DE ALTA PRESIÓN. INCLUIR LA SUSTITUCIÓN DEL JUEGO DE ORINGS.\nC).\tREVISIÓN, LIMPIEZA, VERIFICACIÓN, ALINEACIÓN Y AJUSTE DEL MÓDULO DE MEDICIÓN, LO CUAL COMPRENDE LA BRECHA DE MEDICIÓN, EL EJE EN LA TAPA DE LA AUTOCLAVE Y EL CUERPO DE ROTACIÓN DEL EQUIPO. INCLUIR LA SUSTITUCIÓN DE LA GEOMETRÍA NV CILINDRO CONCÉNTRICO (PARA FLUIDOS DE 2 HASTA 2000 MPAS) EN MAL ESTADO Y UN EJE DE ROTACIÓN (SE ACOPLA CON LA GEOMETRÍA).\nD).\tREVISIÓN Y AJUSTE DEL SISTEMA DE ADQUISICIÓN DE DATOS, ASÍ COMO LA VERIFICACIÓN DEL CORRECTO FUNCIONAMIENTO DE LA COMUNICACIÓN EQUIPO-PC. REVISAR Y ARREGLAR FALLA EN COMUNICACIÓN CON EL SENSOR DE PRESIÓN EN SOFTWARE.\nE).\tREEMPLAZO DE COMPONENTES DAÑADOS. INCLUIR SENSOR TERMOPAR DE TEMPERATURA.\nF).\tVERIFICACIÓN DE MEDICIONES DEL SENSOR DE PRESIÓN, TEMPERATURA Y ESFUERZO DE CORTE.\nG).\tPRUEBAS DE FUNCIONAMIENTO CON ESTÁNDARES CERTIFICADOS. INCLUIR 3 ESTÁNDARES PARA LOS INTERVALOS DE VISCOSIDAD DE MENORES A 100 CP, DE 100 A 1,000 CP Y MAYORES A 1,000 CP.\nH).\tPRUEBA DE FUNCIONAMIENTO GENERAL CON MUESTRAS LÍQUIDAS, REALIZANDO UNA PRUEBA DE DETECCIÓN DE VISCOSIDAD Y",
          "requested_quantity": "1",
          "minimum_quantity": "1",
          "maximum_quantity": null,
          "unit": "SERVICIO",
          "minimum_amount": null,
          "maximum_amount": null
        }
      ]
    }
  ],
  "awards": [
    {
      "id": "C-2026-00073570",
      "internal_reference": "2026000298",
      "title": "SERVICIO DE MANTENIMIENTO PREVENTIVO A DOS VISCOSIMETROS",
      "status": "PUBLICADO",
      "contractor": {
        "name": "DBR DE MEXICO SA DE CV",
        "normalized_name": "DBR DE MEXICO",
        "rfc_type": null,
        "slug": "dbr-de-mexico"
      },
      "contract_period": {
        "published_at": "2026-07-30T16:10:15.000Z",
        "starts_at": "2026-07-30T06:00:00.000Z",
        "ends_at": "2026-09-27T06:00:00.000Z"
      },
      "value": {
        "subtotal": "1217304",
        "tax": "194768.64",
        "total": "1412072.64",
        "maximum_subtotal": "0",
        "maximum_total": "0",
        "currency": "MXN"
      },
      "open_contract_type": null,
      "quantity": null,
      "exercised_quantity": null,
      "participants": [],
      "line_items": [
        {
          "number": "0",
          "cucop_code": "35401-0003",
          "description": "PARTIDA 2: VISCOSÍMETRO DE ALTA PRESIÓN, MARCA PSL, MODELO HPHT.\n\nSERVICIO DE MANTENIMIENTO PREVENTIVO, AL SIGUIENTE EQUIPO CON INVENTARIO SAP, QUE INTEGRAN EL SISTEMA:\n\nNOMBRE DEL EQUIPO EN SAP\tINVENTARIO\tSERIE\tFUNCIÓN\nVISCOSÍMETRO DE ALTA PRESIÓN\t0172067\t16224002\tMEDICIÓN\n\nA CONTINUACIÓN, SE DESCRIBEN LAS ACTIVIDADES QUE DEBE REALIZAR EL PROVEEDOR A CADA UNO DE LOS COMPONENTES:\n\nA).\tREVISIÓN, LIMPIEZA Y AJUSTES DEL SISTEMA DEL BAÑO TÉRMICO MARCA THERMOFISHER SCIENTIFIC, QUE FORMA PARTE INTEGRAL DEL SISTEMA EXPERIMENTAL DEL VISCOSÍMETRO DE ALTA PRESIÓN Y TEMPERATURA MARCA PSL, MODELO HAAKE A25, NÚMERO DE SERIE: 1152720101170124. INCLUIR CAMBIO DE FLUIDO TÉRMICO THERMAL H10 (10 LITROS) Y SUSTITUCIÓN DE LAS DOS MANGUERAS PARA EL CHILLER DE 2 METROS.\nB).\tREVISIÓN, LIMPIEZA, AJUSTES Y CALIBRACIÓN DEL VISCOSÍMETRO HPV VISCOTESTER 550 MARCA PSL, INCLUYE VÁLVULAS, TUBERÍAS Y CONEXIONES DEL VISCOSÍMETRO DE ALTA PRESIÓN. INCLUIR LA SUSTITUCIÓN DEL JUEGO DE ORINGS.\nC).\tREVISIÓN, LIMPIEZA, VERIFICACIÓN, ALINEACIÓN Y AJUSTE DEL MÓDULO DE MEDICIÓN, LO CUAL COMPRENDE LA BRECHA DE MEDICIÓN, EL EJE EN LA TAPA DE LA AUTOCLAVE Y EL CUERPO DE ROTACIÓN DEL EQUIPO. INCLUIR LA SUSTITUCIÓN DE LA GEOMETRÍA NV CILINDRO CONCÉNTRICO (PARA FLUIDOS DE 2 HASTA 2000 MPAS) EN MAL ESTADO Y UN EJE DE ROTACIÓN (SE ACOPLA CON LA GEOMETRÍA).\nD).\tREVISIÓN Y AJUSTE DEL SISTEMA DE ADQUISICIÓN DE DATOS, ASÍ COMO LA VERIFICACIÓN DEL CORRECTO FUNCIONAMIENTO DE LA COMUNICACIÓN EQUIPO-PC. REVISAR Y ARREGLAR FALLA EN COMUNICACIÓN CON EL SENSOR DE PRESIÓN EN SOFTWARE.\nE).\tREEMPLAZO DE COMPONENTES DAÑADOS. INCLUIR SENSOR TERMOPAR DE TEMPERATURA.\nF).\tVERIFICACIÓN DE MEDICIONES DEL SENSOR DE PRESIÓN, TEMPERATURA Y ESFUERZO DE CORTE.\nG).\tPRUEBAS DE FUNCIONAMIENTO CON ESTÁNDARES CERTIFICADOS. INCLUIR 3 ESTÁNDARES PARA LOS INTERVALOS DE VISCOSIDAD DE MENORES A 100 CP, DE 100 A 1,000 CP Y MAYORES A 1,000 CP.\nH).\tPRUEBA DE FUNCIONAMIENTO GENERAL CON MUESTRAS LÍQUIDAS, REALIZANDO UNA PRUEBA DE DETECCIÓN DE VISCOSIDAD Y",
          "unit": "SERVICIO",
          "requested_quantity": "1",
          "awarded_quantity": null,
          "unit_price": "579652",
          "subtotal": "579652",
          "tax": "92744.32",
          "other_taxes": null,
          "total": "672396.32"
        },
        {
          "number": "0",
          "cucop_code": "35401-0003",
          "description": "PARTIDA 1: VISCOSÍMETRO DE ALTA PRESIÓN, MARCA PSL, MODELO HPHT.\n\nSERVICIO DE MANTENIMIENTO PREVENTIVO, AL SIGUIENTE EQUIPO CON INVENTARIO SAP, QUE INTEGRAN EL SISTEMA:\n\nNOMBRE DEL EQUIPO EN SAP\tINVENTARIO\tSERIE\tFUNCIÓN\nVISCOSÍMETRO DE ALTA PRESIÓN\t0172066\t1624003\tMEDICIÓN\n\nA CONTINUACIÓN, SE DESCRIBEN LAS ACTIVIDADES QUE DEBE REALIZAR EL PROVEEDOR A CADA UNO DE LOS COMPONENTES:\n\nA).\tREVISIÓN, LIMPIEZA Y AJUSTES DEL SISTEMA DEL BAÑO TÉRMICO MARCA THERMOFISHER SCIENTIFIC, QUE FORMA PARTE INTEGRAL DEL SISTEMA EXPERIMENTAL DEL VISCOSÍMETRO PARA ALTA PRESIÓN Y TEMPERATURA MARCA PSL MODELO HAAKE A25, NÚMERO DE SERIE: 0152717101170123. INCLUIR CAMBIO DEL FLUIDO TÉRMICO THERMAL H10 (10 LITROS) Y SUSTITUCIÓN DE LAS DOS MANGUERAS PARA EL CHILLER DE 2 METROS.\nB).\tREVISIÓN, LIMPIEZA, AJUSTES Y CALIBRACIÓN DEL VISCOSÍMETRO HPV VISCOTESTER 550 MARCA PSL, EL CUAL INCLUYE EL MÓDULO DE CELDA AUTOCLAVE, ABRAZADERA DE BLOQUEO Y VÁLVULA DE SEGURIDAD, VÁLVULAS, TUBERÍAS Y CONEXIONES DEL VISCOSÍMETRO DE ALTA PRESIÓN (20 KPSI). INCLUIR LA SUSTITUCIÓN DEL JUEGO DE ORINGS.\nC).\tREVISIÓN, LIMPIEZA, VERIFICACIÓN, ALINEACIÓN Y AJUSTE DEL MÓDULO DE MEDICIÓN, LO CUAL COMPRENDE LA BRECHA DE MEDICIÓN, EL EJE EN LA TAPA DE LA AUTOCLAVE Y EL CUERPO DE ROTACIÓN DEL EQUIPO. INCLUIR SUSTITUCIÓN DE LA GEOMETRÍA NV CILINDRO CONCÉNTRICO (PARA FLUIDOS DE 2 HASTA 2000 MPAS) QUE SE ENCUENTRA EN MAL ESTADO.\nD).\tREVISIÓN Y AJUSTE DEL SISTEMA DE ADQUISICIÓN DE DATOS, ASÍ COMO LA VERIFICACIÓN DEL CORRECTO FUNCIONAMIENTO DE LA COMUNICACIÓN EQUIPO-PC. REVISAR Y ARREGLAR FALLA EN COMUNICACIÓN CON EL SENSOR DE PRESIÓN EN SOFTWARE.\nE).\tREEMPLAZO DE COMPONENTES DAÑADOS. INCLUIR UNA FLECHA ROTOR PARA ACOPLAMIENTO DE GEOMETRÍAS.\nF).\tVERIFICACIÓN DE MEDICIONES DEL SENSOR DE PRESIÓN, TEMPERATURA Y ESFUERZO DE CORTE.\nG).\tPRUEBAS DE FUNCIONAMIENTO DEL EQUIPO CON ESTÁNDARES CERTIFICADOS. INCLUIR 3 ESTÁNDARES PARA LOS INTERVALOS DE VISCOSIDAD DE MENORES A 100 CP, DE 100 A 1,000 CP Y MAYORES A 1,000 CP.\nH).\tPRUEBA DE FUNCIONAM",
          "unit": "SERVICIO",
          "requested_quantity": "1",
          "awarded_quantity": null,
          "unit_price": "637652",
          "subtotal": "637652",
          "tax": "102024.32",
          "other_taxes": null,
          "total": "739676.32"
        }
      ]
    }
  ],
  "documents": [
    {
      "id": "93afcbe0-fdb1-4446-8498-a9781242981c",
      "annex_number": 1,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "ANEXO TECNICO.pdf",
      "availability": "available",
      "size_bytes": "1060011",
      "mime_type": "application/pdf",
      "sha256": "a1c7d7b1fd994d08c92abe203b652d2578ff0e554a3fee529d8b1c9b13db1622",
      "uploaded_at": "2026-08-07T23:37:58.963Z",
      "updated_at": "2026-08-07T23:37:58.963Z"
    },
    {
      "id": "8c260ece-2dcf-4a67-8c12-43b28d215904",
      "annex_number": 4,
      "document_type": null,
      "description": "OFICIO DE NOTIFICACIÓN DE ADJUDICACIÓN",
      "filename": "OFIC NOTIF DBR.pdf",
      "availability": "available",
      "size_bytes": "203586",
      "mime_type": "application/pdf",
      "sha256": "5870be1b10109740ff8fc6ca02a41fb7a22253656068e2295ea8a0288e73f34e",
      "uploaded_at": "2026-08-07T23:38:00.118Z",
      "updated_at": "2026-08-07T23:38:00.118Z"
    }
  ],
  "alternates": [],
  "similar": []
}