    "detailed": "SERVICIO DE CABLEADO DE FIBRA ÓPTICA.\n\nLAS ESPECIFICACIONES TÉCNICAS MÍNIMAS QUE DEBEN CUMPLIR EN ENLACE DE FIBRA ÓPTICA, DEBEN SER LAS SIGUIENTES:\n\n•\tGENERALES\n-\tEL CABLE DE FIBRA ÓPTICA DEBE ESTAR DISEÑADO PARA INSTALACIONES EN INTERIORES O EXTERIORES TANTO HORIZONTALES COMO VERTICALES.\n-\tDEBE CONTAR CON FORRO RETARDANTE AL FUEGO. \n-\tLOS HILOS DE FIBRA DEBEN CUMPLIR CON LA CLASIFICACIÓN OM3 DE FIBRA OPTIMIZADA PARA 10G.\n-\tDEBE SER UNA FIBRA ÓPTICA OM3 50/125 MULTIMODO.\n-\tDEBE CONTAR CON UN TIGHT BUFFER (900 ¿M).\n-\tDEBE CONTAR CON UN FORRO DE TIPO OFNR RISER/LSZH CON PROTECCIÓN CONTRA RAYOS UV.\n-\tDEBE SOPORTAR UNA TENSIÓN MÁXIMA DE 400 N.\n-\tDEBE SOPORTAR UNA TEMPERATURA DE OPERACIÓN DE -10°C A 60°C.\n-\tDEBE SOPORTAR UNA TEMPERATURA DE ALMACENAJE DE -20°C A 60°C.\n-\tDEBE CONTAR UN CON DIÁMETRO NOMINAL (D) DE 5.5MM ± 0.5 MM.\n-\tDEBE CONTAR CON UN RADIO MÍNIMO DE CURVATURA DE LOS SIGUIENTES TIPOS: \nA.\tINSTALACIÓN: 20D\nB.\tOPERACIÓN: 10D\n-\tDEBE CONTAR CON UNA RESISTENCIA AL APLASTAMIENTO DE 500N/10CM\n-\tDEBE SER DE 6 HILOS."
  },
  "lifecycle": {
    "section": "concluido",
    "source_status": "ADJUDICADO",
    "moved_at": null
  },
  "buyer": {
    "agency": "INALI",
    "acronym": "INALI",
    "branch": "48 - CULTURA",
    "buying_unit": "DIRECCION DE ADMINISTRACION Y FINANZAS",
    "requesting_unit": "unidad requiriente data",
    "requesting_group": "UNIDAD DE ADMINISTRACIÓN Y FINANZAS",
    "entity": null,
    "slug": "inali",
    "unit_slug": "direccion-de-administracion-y-finanzas-048mdb002"
  },
  "classification": {
    "procedure_type": "ADJUDICACIÓN DIRECTA",
    "contracting_type": "SERVICIOS",
    "publication_type": null,
    "character": "NACIONAL",
    "fiscal_year": 2024,
    "law": "LEY DE ADQUISICIONES, ARRENDAMIENTOS Y SERVICIOS DEL SECTOR PÚBLICO",
    "legal_basis_id": "42",
    "exception_basis": "Art. 42 párrafo primero",
    "internal_control_number": "N31-INALI-AA-2024",
    "supply_source_number": null
  },
  "schedule": {
    "published_at": "2024-05-31T23:32:25.000Z",
    "clarification_meeting_at": null,
    "clarification_questions_deadline_at": null,
    "clarification_responses_deadline_at": null,
    "bid_opening_at": null,
    "award_at": null,
    "estimated_contract_at": "2024-06-18T06:00:00.000Z",
    "site_visit_at": null,
    "estimated_work_start_at": null
  },
  "estimated_value": {
    "minimum": null,
    "maximum": null,
    "currency": "MXN",
    "updated_at": null
  },
  "lots": [
    {
      "number": "1",
      "name": "PARTIDA SOLA",
      "description": "PARTIDA SOLA",
      "requirement_group_id": "1",
      "items": [
        {
          "number": "1",
          "cucop_code": "31701-0002",
          "specific_item_code": "31701",
          "cucop_description": "SERVICIOS DE CONDUCCION DE SEÑALES ANALOGICAS Y DIGITALES",
          "description": "LAS ESPECIFICACIONES TÉCNICAS MÍNIMAS QUE DEBEN CUMPLIR EN ENLACE DE FIBRA ÓPTICA, DEBEN SER LAS SIGUIENTES:\n\n•\tGENERALES\n-\tEL CABLE DE FIBRA ÓPTICA DEBE ESTAR DISEÑADO PARA INSTALACIONES EN INTERIORES O EXTERIORES TANTO HORIZONTALES COMO VERTICALES.\n-\tDEBE CONTAR CON FORRO RETARDANTE AL FUEGO. \n-\tLOS HILOS DE FIBRA DEBEN CUMPLIR CON LA CLASIFICACIÓN OM3 DE FIBRA OPTIMIZADA PARA 10G.\n-\tDEBE SER UNA FIBRA ÓPTICA OM3 50/125 MULTIMODO.\n-\tDEBE CONTAR CON UN TIGHT BUFFER (900 ¿M).\n-\tDEBE CONTAR CON UN FORRO DE TIPO OFNR RISER/LSZH CON PROTECCIÓN CONTRA RAYOS UV.\n-\tDEBE SOPORTAR UNA TENSIÓN MÁXIMA DE 400 N.\n-\tDEBE SOPORTAR UNA TEMPERATURA DE OPERACIÓN DE -10°C A 60°C.\n-\tDEBE SOPORTAR UNA TEMPERATURA DE ALMACENAJE DE -20°C A 60°C.\n-\tDEBE CONTAR UN CON DIÁMETRO NOMINAL (D) DE 5.5MM ± 0.5 MM.\n-\tDEBE CONTAR CON UN RADIO MÍNIMO DE CURVATURA DE LOS SIGUIENTES TIPOS: \nA.\tINSTALACIÓN: 20D\nB.\tOPERACIÓN: 10D\n-\tDEBE CONTAR CON UNA RESISTENCIA AL APLASTAMIENTO DE 500N/10CM\n-\tDEBE SER DE 6 HILOS.",
          "requested_quantity": "1",
          "minimum_quantity": "1",
          "maximum_quantity": null,
          "unit": "SERVICIO",
          "minimum_amount": null,
          "maximum_amount": null
        }
      ]
    }
  ],
  "awards": [
    {
      "id": "C-2024-00074136",
      "internal_reference": "INALI.D.A.4.6C.6/038/2024",
      "title": "SERVICIO DE CABLEADO DE FIBRA ÓPTICA",
      "status": "PUBLICADO",
      "contractor": {
        "name": "COMERCIALIZADORA Y DISTRIBUIDORA CAALESLO S DE RL DE CV",
        "normalized_name": "COMERCIALIZADORA Y DISTRIBUIDORA CAALESLO",
        "rfc_type": null,
        "slug": "comercializadora-y-distribuidora-caaleslo"
      },
      "contract_period": {
        "published_at": "2024-05-31T23:32:25.000Z",
        "starts_at": "2024-06-18T06:00:00.000Z",
        "ends_at": "2024-06-28T06:00:00.000Z"
      },
      "value": {
        "subtotal": "40900",
        "tax": "6544",
        "total": "47444",
        "maximum_subtotal": "0",
        "maximum_total": "0",
        "currency": "MXN"
      },
      "open_contract_type": null,
      "quantity": null,
      "exercised_quantity": null,
      "participants": [],
      "line_items": [
        {
          "number": "0",
          "cucop_code": "31701-0002",
          "description": "LAS ESPECIFICACIONES TÉCNICAS MÍNIMAS QUE DEBEN CUMPLIR EN ENLACE DE FIBRA ÓPTICA, DEBEN SER LAS SIGUIENTES:\n\n•\tGENERALES\n-\tEL CABLE DE FIBRA ÓPTICA DEBE ESTAR DISEÑADO PARA INSTALACIONES EN INTERIORES O EXTERIORES TANTO HORIZONTALES COMO VERTICALES.\n-\tDEBE CONTAR CON FORRO RETARDANTE AL FUEGO. \n-\tLOS HILOS DE FIBRA DEBEN CUMPLIR CON LA CLASIFICACIÓN OM3 DE FIBRA OPTIMIZADA PARA 10G.\n-\tDEBE SER UNA FIBRA ÓPTICA OM3 50/125 MULTIMODO.\n-\tDEBE CONTAR CON UN TIGHT BUFFER (900 ¿M).\n-\tDEBE CONTAR CON UN FORRO DE TIPO OFNR RISER/LSZH CON PROTECCIÓN CONTRA RAYOS UV.\n-\tDEBE SOPORTAR UNA TENSIÓN MÁXIMA DE 400 N.\n-\tDEBE SOPORTAR UNA TEMPERATURA DE OPERACIÓN DE -10°C A 60°C.\n-\tDEBE SOPORTAR UNA TEMPERATURA DE ALMACENAJE DE -20°C A 60°C.\n-\tDEBE CONTAR UN CON DIÁMETRO NOMINAL (D) DE 5.5MM ± 0.5 MM.\n-\tDEBE CONTAR CON UN RADIO MÍNIMO DE CURVATURA DE LOS SIGUIENTES TIPOS: \nA.\tINSTALACIÓN: 20D\nB.\tOPERACIÓN: 10D\n-\tDEBE CONTAR CON UNA RESISTENCIA AL APLASTAMIENTO DE 500N/10CM\n-\tDEBE SER DE 6 HILOS.",
          "unit": "SERVICIO",
          "requested_quantity": "1",
          "awarded_quantity": null,
          "unit_price": "40900",
          "subtotal": "40900",
          "tax": "6544",
          "other_taxes": null,
          "total": "47444"
        }
      ]
    }
  ],
  "documents": [
    {
      "id": null,
      "annex_number": 1,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "3. Anexo tecnico_Cableado FO 2024.pdf",
      "availability": "available",
      "size_bytes": "194772",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-05T05:51:22.061Z",
      "updated_at": "2025-12-05T05:51:22.062Z"
    },
    {
      "id": null,
      "annex_number": 3,
      "document_type": null,
      "description": "OFICIO DE ADJUDICACIÓN",
      "filename": "Oficio INALI D.A.5.17-039-2024 ADJUDICACION COM DIST CAALESLO.pdf",
      "availability": "available",
      "size_bytes": "965831",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-05T05:51:23.818Z",
      "updated_at": "2025-12-05T05:51:23.819Z"
    }
  ],
  "alternates": [],
  "similar": [
    {
      "numero_procedimiento": "aa-13-312-013000999-n-485-2024",
      "nombre_procedimiento": "NAC 13-0420/24 REQ 806 INFO072/24 MATERIAL ELECTRICO Y ELECTRONICO",
      "dependencia": "SEMAR",
      "siglas": "SEMAR",
      "score": 0.2174137830734253
    },
    {
      "numero_procedimiento": "aa-13-312-013000999-n-613-2024",
      "nombre_procedimiento": "NAC 13-0646/24 REQ 1226 INFO145 MATERIAL ELECTRICO Y ELECTRONICO",
      "dependencia": "SEMAR",
      "siglas": "SEMAR",
      "score": 0.2505977600456606
    },
    {
      "numero_procedimiento": "aa-72-060-913066991-n-48-2023",
      "nombre_procedimiento": "INSTALACION DE 2 KM DE FIBRA OPTICA PARA CONECTAR 10 EDIFICIOS DE LA UNIVERSIDAD",
      "dependencia": "UTECTULANCINGO",
      "siglas": "UTECTULANCINGO",
      "score": 0.25264817476272583
    },
    {
      "numero_procedimiento": "aa-13-312-013000999-n-592-2024",
      "nombre_procedimiento": "NAC 13-0655/24 REQ 1244 INFO153 MATERIAL ELECTRICO Y ELECTRONICO",
      "dependencia": "SEMAR",
      "siglas": "SEMAR",
      "score": 0.253445908221845
    },
    {
      "numero_procedimiento": "aa-48-l8p-048l8p001-n-53-2025",
      "nombre_procedimiento": "ADQUISICIÓN DE CABLE DE INTERCONEXIÓN CATEGORÍA 6A (305 METROS / 1000 PIES)",
      "dependencia": "ECHASA",
      "siglas": "ECHASA",
      "score": 0.2715758681297302
    },
    {
      "numero_procedimiento": "aa-13-312-013000999-n-1520-2023",
      "nombre_procedimiento": "NAC 13-1581/23  REQ 2174 NFO101/23 MATERIAL ELECTRICO Y ELECTRONICO",
      "dependencia": "SECRETARIA DE MARINA",
      "siglas": "SEMAR",
      "score": 0.27363649292426706
    }
  ]
}