{
  "html_url": "https://licitia.com.mx/adjudicacion/aa-50-gyr-050gyr029-t-188-2026",
  "canonical": "https://licitia.com.mx/adjudicacion/aa-50-gyr-050gyr029-t-188-2026",
  "id": "53db12a92c890e0ae0639e1200a9b765",
  "procedure_number": "AA-50-GYR-050GYR029-T-188-2026",
  "file_number": "E-2026-00058631",
  "title": "ADQUISICION DE IMPLANTE COCLEAR PARA PACIENTE ESPECIFICO",
  "description": {
    "short": "Adquisiciones, arrendamientos y servicios, dentro de los montos máximos establecidos en el PEF.",
    "detailed": "ADQUISICION DE IMPLANTE COCLEAR PARA PACIENTE ESPECIFICO"
  },
  "lifecycle": {
    "section": "concluido",
    "source_status": "ADJUDICADO",
    "moved_at": null
  },
  "buyer": {
    "agency": "INSTITUTO MEXICANO DEL SEGURO SOCIAL",
    "acronym": "IMSS",
    "branch": "50 - INSTITUTO MEXICANO DEL SEGURO SOCIAL",
    "buying_unit": "DEPARTAMENTO DE ADQUISICION DE BIENES Y CONTRATACION DE SERVICIOS",
    "requesting_unit": "unidad requiriente data",
    "requesting_group": "DEPARTAMENTO DE ADQUISICION DE BIENES Y CONTRATACION DE SERVICIOS",
    "entity": "imss",
    "slug": "imss",
    "unit_slug": "departamento-de-adquisicion-de-bienes-y-contratacion-de-servicios-050gyr029"
  },
  "classification": {
    "procedure_type": "ADJUDICACIÓN DIRECTA",
    "contracting_type": "ADQUISICIONES",
    "publication_type": null,
    "character": "INTERNACIONAL BAJO LA COBERTURA DE TRATADOS",
    "fiscal_year": 2026,
    "law": "LEY DE ADQUISICIONES, ARRENDAMIENTOS Y SERVICIOS DEL SECTOR PÚBLICO",
    "legal_basis_id": "217",
    "exception_basis": "Art. 55 párrafo primero",
    "internal_control_number": "ADQUISICION DE IMPLANTE COCLEAR PARA PACIENTE ESPECIFICO",
    "supply_source_number": null
  },
  "schedule": {
    "published_at": "2026-06-09T23:01:44.000Z",
    "clarification_meeting_at": null,
    "clarification_questions_deadline_at": null,
    "clarification_responses_deadline_at": null,
    "bid_opening_at": "2026-06-05T20:00:00.000Z",
    "award_at": null,
    "estimated_contract_at": "2026-06-15T06:00:00.000Z",
    "site_visit_at": null,
    "estimated_work_start_at": null
  },
  "estimated_value": {
    "minimum": null,
    "maximum": null,
    "currency": "MXN",
    "updated_at": null
  },
  "lots": [
    {
      "number": "1",
      "name": "PARTIDA SOLA",
      "description": "PARTIDA SOLA",
      "requirement_group_id": "1",
      "items": [
        {
          "number": "1",
          "cucop_code": "25401-0609",
          "specific_item_code": "25401",
          "cucop_description": "IMPLANTE COCLEAR",
          "description": "IMPLANTE COCLEAR. DISPOSITIVO DESTINADO PARA LA RESTAURACIÓN PARCIAL DE LA SENSACIÓN AUDITIVA A NIÑOS CON HIPOACUSIA NEUROSENSORIAL BILATERAL DE SEVERA A PROFUNDA. CONSTA DE UN RECEPTOR-ESTIMULADOR CONFORMADO POR UN CONJUNTO DE ELECTRODOS QUE SE INSERTAN QUIRÚRGICAMENTE EN LA CÓCLEA Y SE IMPLANTA EN EL CRÁNEO, CERCA DEL PABELLÓN AURICULAR Y UN PROCESADOR DE SONIDO EXTERNO, QUE CONVIERTE EL SONIDO EN SEÑALES ELÉCTRICAS QUE SE TRANSMITEN AL RECEPTOR ESTIMULADOR. PROCESADOR DIGITAL DE SONIDO EXTERNO: RESISTENTE A LA HUMEDAD, CON MEMORIA PARA ALMACENAR 4 MAPAS O PROGRAMAS ACTUALIZABLES HASTA LLEGAR A UN ÓPTIMO DEFINIDO POR EL AUDIÓLOGO, CAPACIDAD DE CAMBIAR PROGRAMAS Y VOLÚMENES DE MANERA EXTERNA POR EL USUARIO, ALARMAS AUDIBLES O VISUALES DE BATERÍA BAJA Y MAL FUNCIONAMIENTO DEL PROCESADOR, GANCHO PEDIÁTRICO PARA RETROAURICULAR O ARNÉS O ESTUCHE O FIJADOR PARA CUERPO. JUEGO DE BATERÍAS NECESARIAS PARA LA OPERACIÓN DEL IMPLANTE: TRES, TIPO RECARGABLE CON UN CARGADOR DE BATERÍAS, CABLE Y FUENTE DE ALIMENTACIÓN; Y TRES TIPOS DESECHABLES, CON UNA PORTA BATERÍA EN CASO DE SER NECESARIO. BOBINA O ANTENA: CON IMÁN INTEGRADO Y CABLE CONECTOR PARA PROCESADOR. MICRÓFONO OMNIDIRECCIONAL O RANGO MÍNIMO DE 180 GRADOS. ENTRADA Y CABLE PARA DISPOSITIVOS FM. ESTIMULADOR RECEPTOR IMPLANTABLE DE TITANIO. ELECTRODOS INTRACOCLEARES DE 16 MÁS TIERRA: ELECTRODO MONOPOLARES O BIPOLARES O MULTIPOLAR, ESTIMULACIÓN MONOPOLAR MULTICANAL A UNA TAZA DE ESTIMULACIÓN DE 83 000 PULSOS POR SEGUNDO O MAYOR, PULSOS TRIFÁSICOS. IMÁN REMOVIBLE INTERNO EN EL CUERPO DEL IMPLANTE. MÉTODO DE ESTIMULACIÓN PULSÁTIL O CONTINUO. TRANSMISIÓN DE LA SEÑAL DIGITAL TRASCUTÁNEA O PERCUTÁNEA. TODOS LOS ELEMENTOS DEBEN SER REEMPLAZABLES Y COMPATIBLES ENTRE SÍ, DE ACUERDO A MARCA Y MODELO. SOFTWARE: COMPATIBLE CON LOS MODELOS FUTUROS, CAPAZ DE REALIZAR Y MODIFICAR MAPAS O PROGRAMAS, MEDICIÓN DE REFLEJO ESTAPEDIAL, TELEMETRÍA QUE VERIFIQUE EL FUNCIONAMIENTO INTERNO DEL IMPLANTE, MEDICIÓN DE LA RESPUESTA DEL NERVIO AUDITIVO",
          "requested_quantity": "1",
          "minimum_quantity": "1",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        }
      ]
    }
  ],
  "awards": [
    {
      "id": "C-2026-00050445",
      "internal_reference": "050GYR029T18826-187-00",
      "title": "ADQUISICION DE IMPLANTE COCLEAR PARA PACIENTE ESPECIFICO",
      "status": "PUBLICADO",
      "contractor": {
        "name": "PHONO & MEDICAL SA DE CV",
        "normalized_name": "PHONO Y MEDICAL",
        "rfc_type": null,
        "slug": "phono-y-medical"
      },
      "contract_period": {
        "published_at": "2026-06-23T23:14:09.000Z",
        "starts_at": "2026-06-10T06:00:00.000Z",
        "ends_at": "2026-12-31T06:00:00.000Z"
      },
      "value": {
        "subtotal": "439655.17",
        "tax": "70344.83",
        "total": "510000",
        "maximum_subtotal": "0",
        "maximum_total": "0",
        "currency": "MXN"
      },
      "open_contract_type": null,
      "quantity": null,
      "exercised_quantity": null,
      "participants": [],
      "line_items": [
        {
          "number": "0",
          "cucop_code": "25401-0609",
          "description": "IMPLANTE COCLEAR. DISPOSITIVO DESTINADO PARA LA RESTAURACIÓN PARCIAL DE LA SENSACIÓN AUDITIVA A NIÑOS CON HIPOACUSIA NEUROSENSORIAL BILATERAL DE SEVERA A PROFUNDA. CONSTA DE UN RECEPTOR-ESTIMULADOR CONFORMADO POR UN CONJUNTO DE ELECTRODOS QUE SE INSERTAN QUIRÚRGICAMENTE EN LA CÓCLEA Y SE IMPLANTA EN EL CRÁNEO, CERCA DEL PABELLÓN AURICULAR Y UN PROCESADOR DE SONIDO EXTERNO, QUE CONVIERTE EL SONIDO EN SEÑALES ELÉCTRICAS QUE SE TRANSMITEN AL RECEPTOR ESTIMULADOR. PROCESADOR DIGITAL DE SONIDO EXTERNO: RESISTENTE A LA HUMEDAD, CON MEMORIA PARA ALMACENAR 4 MAPAS O PROGRAMAS ACTUALIZABLES HASTA LLEGAR A UN ÓPTIMO DEFINIDO POR EL AUDIÓLOGO, CAPACIDAD DE CAMBIAR PROGRAMAS Y VOLÚMENES DE MANERA EXTERNA POR EL USUARIO, ALARMAS AUDIBLES O VISUALES DE BATERÍA BAJA Y MAL FUNCIONAMIENTO DEL PROCESADOR, GANCHO PEDIÁTRICO PARA RETROAURICULAR O ARNÉS O ESTUCHE O FIJADOR PARA CUERPO. JUEGO DE BATERÍAS NECESARIAS PARA LA OPERACIÓN DEL IMPLANTE: TRES, TIPO RECARGABLE CON UN CARGADOR DE BATERÍAS, CABLE Y FUENTE DE ALIMENTACIÓN; Y TRES TIPOS DESECHABLES, CON UNA PORTA BATERÍA EN CASO DE SER NECESARIO. BOBINA O ANTENA: CON IMÁN INTEGRADO Y CABLE CONECTOR PARA PROCESADOR. MICRÓFONO OMNIDIRECCIONAL O RANGO MÍNIMO DE 180 GRADOS. ENTRADA Y CABLE PARA DISPOSITIVOS FM. ESTIMULADOR RECEPTOR IMPLANTABLE DE TITANIO. ELECTRODOS INTRACOCLEARES DE 16 MÁS TIERRA: ELECTRODO MONOPOLARES O BIPOLARES O MULTIPOLAR, ESTIMULACIÓN MONOPOLAR MULTICANAL A UNA TAZA DE ESTIMULACIÓN DE 83 000 PULSOS POR SEGUNDO O MAYOR, PULSOS TRIFÁSICOS. IMÁN REMOVIBLE INTERNO EN EL CUERPO DEL IMPLANTE. MÉTODO DE ESTIMULACIÓN PULSÁTIL O CONTINUO. TRANSMISIÓN DE LA SEÑAL DIGITAL TRASCUTÁNEA O PERCUTÁNEA. TODOS LOS ELEMENTOS DEBEN SER REEMPLAZABLES Y COMPATIBLES ENTRE SÍ, DE ACUERDO A MARCA Y MODELO. SOFTWARE: COMPATIBLE CON LOS MODELOS FUTUROS, CAPAZ DE REALIZAR Y MODIFICAR MAPAS O PROGRAMAS, MEDICIÓN DE REFLEJO ESTAPEDIAL, TELEMETRÍA QUE VERIFIQUE EL FUNCIONAMIENTO INTERNO DEL IMPLANTE, MEDICIÓN DE LA RESPUESTA DEL NERVIO AUDITIVO",
          "unit": "PIEZA",
          "requested_quantity": "1",
          "awarded_quantity": null,
          "unit_price": "439655.17",
          "subtotal": "439655.17",
          "tax": "70344.83",
          "other_taxes": null,
          "total": "510000"
        }
      ]
    }
  ],
  "documents": [
    {
      "id": "7df13c48-d559-486c-b97b-014bc969ff1a",
      "annex_number": 1,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "AT y TC.pdf",
      "availability": "available",
      "size_bytes": "547358",
      "mime_type": "application/pdf",
      "sha256": "4598a49adc781d6ef5262add72fcf6b4a3cde1b5c1228921d32e557663c9eec0",
      "uploaded_at": "2026-08-07T09:19:25.252Z",
      "updated_at": "2026-08-07T09:19:25.253Z"
    },
    {
      "id": "11fe7518-c24b-49d0-b7ce-6e47b8114a73",
      "annex_number": 4,
      "document_type": null,
      "description": "OFICIO DE NOTIFICACIÓN DE ADJUDICACIÓN",
      "filename": "Fallo T-188.pdf",
      "availability": "available",
      "size_bytes": "663067",
      "mime_type": "application/pdf",
      "sha256": "dcbdd7b232956d8d06ce76548ab6f61ef07bed8adee42d0ae403cf592c81544a",
      "uploaded_at": "2026-08-07T09:19:26.330Z",
      "updated_at": "2026-08-07T09:19:26.330Z"
    }
  ],
  "alternates": [],
  "similar": []
}