{
  "html_url": "https://licitia.com.mx/adjudicacion/aa-50-gyr-050gyr045-t-229-2024",
  "canonical": "https://licitia.com.mx/adjudicacion/aa-50-gyr-050gyr045-t-229-2024",
  "id": "a867579a8b7246c1845e4abef45635a2",
  "procedure_number": "AA-50-GYR-050GYR045-T-229-2024",
  "file_number": "E-2024-00098022",
  "title": "ADQUISICION DE SENSOR PARA GLUCOMETRO PROGRAMA ONCOCREA",
  "description": {
    "short": "Peligro o alteración del orden social, economía, servicios públicos, salubridad, seguridad o ambiente, por caso fortuito o de fuerza mayor.",
    "detailed": "ADQUISICION DE SENSOR PARA GLUCOMETRO PROGRAMA ONCOCREA"
  },
  "lifecycle": {
    "section": "concluido",
    "source_status": "ADJUDICADO",
    "moved_at": null
  },
  "buyer": {
    "agency": "IMSS",
    "acronym": "IMSS",
    "branch": "50 - INSTITUTO MEXICANO DEL SEGURO SOCIAL",
    "buying_unit": "UMAE HOSPITAL DE ESPECILIDADES NO.71 DEPTO DE ABASTECIMIENTO",
    "requesting_unit": "unidad requiriente data",
    "requesting_group": "UMAE HOSPITAL DE ESPECILIDADES NO.71 DEPTO DE ABASTECIMIENTO",
    "entity": null,
    "slug": "imss",
    "unit_slug": "umae-hospital-de-especilidades-no-71-depto-de-abastecimiento-050gyr045"
  },
  "classification": {
    "procedure_type": "ADJUDICACIÓN DIRECTA",
    "contracting_type": "ADQUISICIONES",
    "publication_type": null,
    "character": "INTERNACIONAL BAJO LA COBERTURA DE TRATADOS",
    "fiscal_year": 2024,
    "law": "LEY DE ADQUISICIONES, ARRENDAMIENTOS Y SERVICIOS DEL SECTOR PÚBLICO",
    "legal_basis_id": "23",
    "exception_basis": "Art. 41 fr. II",
    "internal_control_number": "AA-50-GYR-050GYR045-T-2024",
    "supply_source_number": null
  },
  "schedule": {
    "published_at": "2024-10-30T18:23:15.000Z",
    "clarification_meeting_at": null,
    "clarification_questions_deadline_at": null,
    "clarification_responses_deadline_at": null,
    "bid_opening_at": null,
    "award_at": null,
    "estimated_contract_at": "2024-09-30T06:00:00.000Z",
    "site_visit_at": null,
    "estimated_work_start_at": null
  },
  "estimated_value": {
    "minimum": null,
    "maximum": null,
    "currency": "MXN",
    "updated_at": null
  },
  "lots": [
    {
      "number": "1",
      "name": "PARTIDA SOLA",
      "description": "PARTIDA SOLA",
      "requirement_group_id": "1",
      "items": [
        {
          "number": "1",
          "cucop_code": "53101-2084",
          "specific_item_code": "53101",
          "cucop_description": "531.345.0039 GLUCOMETRO. DISEÑADO PARA MEDIR LOS NIVELES DE GLUCOSA EN LIQUIDO INTERSTICIAL DEL USUARIO A TRAVES DE UN SENSOR AMPEROMETRICO ELECTROQUIMICO. LA COLA DEL SENSOR SE INSERTA EN EL TEJIDO SUBCUTANEO (PUEDE PERMANECER PUESTO HASTA 14 DIAS) Y GENERA UNA CORRIENTE ELECTRICA A TRAVES DE LA OXIDACION DE GLUCOSA EN EL LIQUIDO INTERSTICIAL. CADA SENSOR INCLUYE UN IDENTIFICADOR UNICO QUE SE REGISTRA POR EL LECTOR DURANTE LA ACTIVACION Y LA CAPTURA DE DATOS. EL SISTEMA UTILIZA ESTE IDENTIFICADOR PARA ASEGURAR LA VINCULACION DEL SENSOR Y LECTOR. EL LECTOR VINCULADO PUEDE OBTENER LOS DATOS ALMACENADOS EN EL SENSOR A TRAVES DE LA TRANSMISION INALAMBRICA DE DATOS DE RADIOFRECUENCIA A TRAVES DE UNA ACCION E ESCANEO. EL SISTEMA TAMBIEN INCORPORA UN MEDIDOR DE GLUCOSA EN SANGRE Y CETONA. TIENE TRES PARTES PRINCIPALES: A. UN ENSAMBLAJE COLOCADO EN EL CUERPO, DESECHABLE (SENSOR) QUE INCORPORA UN SENSOR DE GLUCOSA ELECTROQUIMICO IMPLANTADO SUBCUTANEAMENTE Y ELEMENTOS ELECTRONICOS ASOCIADOS: B. UN DISPOSITIVO DE INSERCION DEL SENSOR, DESECHABLE (UNIDAD DE SUMINISTRO DEL PARCHE) QUE CONSTA DE DOS COMPONENTES SECUNDARIOS (APLICADOR DEL SENSOR Y PAQUETE DEL SENSOR) SE UTILIZA PARA ADHERIR EL SENSOR A LA PIEL DEL PACIENTE INSERTAR LA COLA DEL SENSOR APROXIMADAMENTE 5.5 MM DEBAJO DE LA SUPERFICIE DE LA PIEL; C. UN DISPOSITIVO PORTATIL (LECTOR) QUE RECOLECTA MUESTRA LAS LECTURAS DE GLUCOSA OBTENIDAS DEL SENSOR DURANTE UNA EXPLORACION EL LECTOR TIENE UN PUERTO DE BANDA INCORPORADO CON FUNCIONALIDAD DE MEDIDOR DE CETONAS EN SANGRE Y GLUCOSA EN SANGRE Y UNA INTERFAZ DEL USUARIO QUE INCLUYE FUNCIONES DE REGISTRO DE EVENTOS. EL LECTOR SE USA PARA OBTENER LA LECTURA DE GLUCOSA DEL SENSOR. PUEDE ALMACENAR APROXIMADAMENTE 90 DIAS DEL HISTORIAL DE LECTURAS DE GLUCOSA Y LAS NOTAS QUE INGRESE ACERCA DE SUS ACTIVIDADES, COMO APLICARSE INSULINA, COMER ALIMENTOS O HACER EJERCICIO. UTILIZA UNA BATERIA INTERNA TIPO LIPO. CUENTA CON DOS SOFTWARES INCORPORADOS DENTRO DEL SISTEMA: EL SOFTWARE DEL LECTOR Y EL SOFTWARE DEL PARCHE. EL SOFTWARE ESTA DISEÑADO PARA COMUNICARSE AL PARCHE A TRAVES DE LA INTERFAZ RFID PARA RECOLECTAR LOS DATOS DE MEDICION DEL SENSOR Y CONVERTIR LOS DATOS MEDIDOS EN RESULTADOS DE GLUCOSA DE FLUIDO INTERSTICIAL (IST). TAMBIEN SOPORTA LA FUNCION DE MEDICION DE TIRA DE GLUCOSA Y DE CETONA POR LO TANTO ESTA DISEÑADA PARA SER UTILIZADO CON TIRAS REACTIVAS DE GLUCOSA EN SANGRE Y CETONAS EN SANGRE Y SOLUCION DE CONTROL, Y SOPORTA UNA PANTALLA DE COLOR TACTIL DE ALTA RESOLUCION Y RETROILUMINACION PARA LA INTERFAZ DEL USUARIO, UN BOTON Y COMUNICACION DE DATOS USB.",
          "description": "53134503470001\tSENSOR PARA GLUCOMETRO. TIENE DOS PARTES PRINCIPALES: UN LECTOR DE MANO Y UNSENSOR DESECHABLE QUE SE LLEVA PUESTO EN EL CUERPO. EL LECTOR SE UTILIZA PARAESCANEAR EL SENSOR DE MANERA INALAMBRICA Y OBTENER LA LECTURA DE LA GLUCOSA OCETONAS EN SANGRE JUNTO CON EL EQUIPO. EL SENSOR MIDE Y ALMACENA LAS LECTURAS DEGLUCOSA MIENTRAS LO LLEVA PUESTO. INICIALMENTE VIENE EN DOS PARTES: UNA PARTE ENEL ENVASE DEL SENSOR Y LA OTRA ES EL APLICADOR DEL SENSOR. SE APLICA EL SENSOREN LA PARTE POSTERIOR DEL BRAZO SIGUIENDO LAS INSTRUCCIONES. EL SENSOR TIENE UNAPUNTA PEQUEÑA Y FLEXIBLE QUE SE INSERTA A PENAS DEBAJO DE LA PIEL. PUEDE LLEVARPUESTO EL SENSOR DURANTE HASTA 14 DIAS. ESTERILIZADO POR RADIACION GAMMA. ELSENSOR ES ENSAMBLADO POR EL USUARIO A TRAVES DEL EMPAREJAMIENTO DEL PAQUETE DELSENSOR Y APLICADOR DEL SENSOR, PREPARANDO EL DISPOSITIVO PARA EL DESPLIEGUE Y LAINSERCION SUBCUTANEA DE LA COLA DEL SENSOR. ESTA ETAPA TRANSFIERE EL ENSAMBLAJEDEL TAPON DESDE EL PAQUETE DEL SENSOR AL APLICADOR DEL SENSOR Y PREPARA ELAPLICADOR DEL SENSOR PARA APLICAR EL SENSOR E INSERTAR LA COLA DEL SENSOR PORVIA SUBCUTANEA. UNA ALMOHADILLA ADHESIVA ADHIERE EL SENSOR A LA PIEL DURANTE ELUSO DEL DISPOSITIVO. EL FILO, DESTINADO A ACOMPAÑAR A LA COLA DEL SENSOR DENTRODEL TEJIDO SUBCUTANEO, SE RETRAE DENTRO DEL APLICADOR. LA COLA DEL SENSOR ESTACOMPUESTA DE UN SUSTRATO DE POLIESTER RECUBIERTO POR UNA SERIE DE CAPAS DE TINTAAPILADAS, AMBAS CONDUCIENDO (LOS ELECTRODOS) Y AISLANDO (LAS CAPASDIELECTRICAS), EN AMBOS LADOS DEL SUSTRATO. LOS CONECTORES DEL ELECTRODOPERMITEN LA CONEXION AL INSTRUMENTAL ELECTROQUIMICO (POTENCIOSTATO) A FIN DEMEDIR LAS CORRIENTES RELACIONADAS CON LA GLUCOSA. EL MONTAJE, TAPON, ALMOHADILLAADHESIVA Y LA COLA DEL SENSOR ESTAN EN CONTACTO DIRECTO CON EL CUERPO DURANTE ELUSO DEL DISPOSITIVO. EL FILO ESTA HECHO DE ACERO INOXIDABLE, PENETRA POR POCOTIEMPO LA PIEL Y PERMITE LA IMPLANTACION SUBCUTANEA DE LA COLA DEL SENSOR, ANTESDE RETRAERSE DENTRO DEL APLICADOR DEL SENSOR.",
          "requested_quantity": "400",
          "minimum_quantity": "400",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        }
      ]
    }
  ],
  "awards": [
    {
      "id": "C-2024-00131200",
      "internal_reference": "D244034",
      "title": "ADQUISICION DE SENSOR PARA GLUCOMETRO PROGRAMA ONCOCREA",
      "status": "PUBLICADO",
      "contractor": {
        "name": "CORPORACION ARMO SA DE CV",
        "normalized_name": "CORPORACION ARMO",
        "rfc_type": null,
        "slug": "corporacion-armo"
      },
      "contract_period": {
        "published_at": "2024-10-30T18:23:15.000Z",
        "starts_at": "2024-09-30T06:00:00.000Z",
        "ends_at": "2024-12-31T06:00:00.000Z"
      },
      "value": {
        "subtotal": "571600",
        "tax": "91456",
        "total": "663056",
        "maximum_subtotal": "0",
        "maximum_total": "0",
        "currency": "MXN"
      },
      "open_contract_type": null,
      "quantity": null,
      "exercised_quantity": null,
      "participants": [],
      "line_items": [
        {
          "number": "0",
          "cucop_code": "53101-2084",
          "description": "53134503470001\tSENSOR PARA GLUCOMETRO. TIENE DOS PARTES PRINCIPALES: UN LECTOR DE MANO Y UNSENSOR DESECHABLE QUE SE LLEVA PUESTO EN EL CUERPO. EL LECTOR SE UTILIZA PARAESCANEAR EL SENSOR DE MANERA INALAMBRICA Y OBTENER LA LECTURA DE LA GLUCOSA OCETONAS EN SANGRE JUNTO CON EL EQUIPO. EL SENSOR MIDE Y ALMACENA LAS LECTURAS DEGLUCOSA MIENTRAS LO LLEVA PUESTO. INICIALMENTE VIENE EN DOS PARTES: UNA PARTE ENEL ENVASE DEL SENSOR Y LA OTRA ES EL APLICADOR DEL SENSOR. SE APLICA EL SENSOREN LA PARTE POSTERIOR DEL BRAZO SIGUIENDO LAS INSTRUCCIONES. EL SENSOR TIENE UNAPUNTA PEQUEÑA Y FLEXIBLE QUE SE INSERTA A PENAS DEBAJO DE LA PIEL. PUEDE LLEVARPUESTO EL SENSOR DURANTE HASTA 14 DIAS. ESTERILIZADO POR RADIACION GAMMA. ELSENSOR ES ENSAMBLADO POR EL USUARIO A TRAVES DEL EMPAREJAMIENTO DEL PAQUETE DELSENSOR Y APLICADOR DEL SENSOR, PREPARANDO EL DISPOSITIVO PARA EL DESPLIEGUE Y LAINSERCION SUBCUTANEA DE LA COLA DEL SENSOR. ESTA ETAPA TRANSFIERE EL ENSAMBLAJEDEL TAPON DESDE EL PAQUETE DEL SENSOR AL APLICADOR DEL SENSOR Y PREPARA ELAPLICADOR DEL SENSOR PARA APLICAR EL SENSOR E INSERTAR LA COLA DEL SENSOR PORVIA SUBCUTANEA. UNA ALMOHADILLA ADHESIVA ADHIERE EL SENSOR A LA PIEL DURANTE ELUSO DEL DISPOSITIVO. EL FILO, DESTINADO A ACOMPAÑAR A LA COLA DEL SENSOR DENTRODEL TEJIDO SUBCUTANEO, SE RETRAE DENTRO DEL APLICADOR. LA COLA DEL SENSOR ESTACOMPUESTA DE UN SUSTRATO DE POLIESTER RECUBIERTO POR UNA SERIE DE CAPAS DE TINTAAPILADAS, AMBAS CONDUCIENDO (LOS ELECTRODOS) Y AISLANDO (LAS CAPASDIELECTRICAS), EN AMBOS LADOS DEL SUSTRATO. LOS CONECTORES DEL ELECTRODOPERMITEN LA CONEXION AL INSTRUMENTAL ELECTROQUIMICO (POTENCIOSTATO) A FIN DEMEDIR LAS CORRIENTES RELACIONADAS CON LA GLUCOSA. EL MONTAJE, TAPON, ALMOHADILLAADHESIVA Y LA COLA DEL SENSOR ESTAN EN CONTACTO DIRECTO CON EL CUERPO DURANTE ELUSO DEL DISPOSITIVO. EL FILO ESTA HECHO DE ACERO INOXIDABLE, PENETRA POR POCOTIEMPO LA PIEL Y PERMITE LA IMPLANTACION SUBCUTANEA DE LA COLA DEL SENSOR, ANTESDE RETRAERSE DENTRO DEL APLICADOR DEL SENSOR.",
          "unit": "PIEZA",
          "requested_quantity": "400",
          "awarded_quantity": null,
          "unit_price": "1429",
          "subtotal": "571600",
          "tax": "91456",
          "other_taxes": null,
          "total": "663056"
        }
      ]
    }
  ],
  "documents": [
    {
      "id": null,
      "annex_number": 1,
      "document_type": null,
      "description": "JUSTIFICACIÓN DE EXCEPCIÓN",
      "filename": "JUSTIFICACION.pdf",
      "availability": "available",
      "size_bytes": "58671",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-04T07:30:48.538Z",
      "updated_at": "2025-12-04T07:30:48.540Z"
    },
    {
      "id": null,
      "annex_number": 1,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "ANEXO TECNICO.pdf",
      "availability": "available",
      "size_bytes": "355040",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-04T07:30:49.824Z",
      "updated_at": "2025-12-04T07:30:49.825Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "acta notif fallo",
      "filename": "NOTIF FALLO AA-045-T-229-2024.pdf",
      "availability": "available",
      "size_bytes": "251298",
      "mime_type": "application/pdf",
      "sha256": "1799a2db4cf71aff039916d12199e37777b3294f01e05c20cd127e31228bcc44",
      "uploaded_at": "2025-12-04T07:30:51.195Z",
      "updated_at": "2026-08-06T02:38:16.249Z"
    },
    {
      "id": null,
      "annex_number": 5,
      "document_type": null,
      "description": "OFICIO DE ADJUDICACIÓN",
      "filename": "ACTA NOTIF FALLO AA-045-T-229-2024.pdf",
      "availability": "available",
      "size_bytes": "251298",
      "mime_type": "application/pdf",
      "sha256": "1799a2db4cf71aff039916d12199e37777b3294f01e05c20cd127e31228bcc44",
      "uploaded_at": "2025-12-04T07:30:52.284Z",
      "updated_at": "2026-08-06T02:38:16.249Z"
    },
    {
      "id": null,
      "annex_number": 6,
      "document_type": null,
      "description": "ANEXOS OFICIO DE ADJUDICACIÓN",
      "filename": "D244034_redacted.pdf",
      "availability": "available",
      "size_bytes": "11802601",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-04T07:31:10.917Z",
      "updated_at": "2025-12-04T07:31:10.918Z"
    }
  ],
  "alternates": [],
  "similar": [
    {
      "numero_procedimiento": "aa-50-gyr-050gyr998-t-452-2025",
      "nombre_procedimiento": "AA-50-GYR-050GYR998-T-452-2025ADQUISICIÓN DE “SENSOR PARA GLUCOMETRO” GRUPO 531",
      "dependencia": "IMSS",
      "siglas": "IMSS",
      "score": 0.07090473175048828
    },
    {
      "numero_procedimiento": "aa-51-gyn-051gyn041-t-85-2023",
      "nombre_procedimiento": "SENSORES PARA GLUCÓMETRO, SISTEMA FLASH DE MONITOREO CONTINUO DE GLUCOSA CAJA CO",
      "dependencia": "INSTITUTO DE SEGURIDAD Y SERVICIOS SOCIALES DE LOS TRABAJADORES DEL ESTADO",
      "siglas": "ISSSTE",
      "score": 0.07414513384430643
    },
    {
      "numero_procedimiento": "aa-50-gyr-050gyr045-t-169-2024",
      "nombre_procedimiento": "ADQ. DE SENSOR PARA GLUCOMETRO Y ADAPTADOR PARA PROGRAMA ONCOCREA",
      "dependencia": "INSTITUTO MEXICANO DEL SEGURO SOCIAL",
      "siglas": "IMSS",
      "score": 0.09020788015173986
    },
    {
      "numero_procedimiento": "aa-50-gyr-050gyr018-i-308-2024",
      "nombre_procedimiento": "AA-I-308-2024 ADQ. DE APARATOS MEDICOS Y CONSUMIBLES DE EQUIPOS MEDICOS Y DE LAB",
      "dependencia": "INSTITUTO MEXICANO DEL SEGURO SOCIAL",
      "siglas": "IMSS",
      "score": 0.14133141740185395
    },
    {
      "numero_procedimiento": "aa-50-gyr-050gyr998-t-770-2024",
      "nombre_procedimiento": "AA-50-GYR-050GYR998-T-770-2024 ADQUISICIÓN CONSUMIBLES EQUIPO MEDICO GPO 379",
      "dependencia": "IMSS",
      "siglas": "IMSS",
      "score": 0.18383736514075644
    },
    {
      "numero_procedimiento": "aa-50-gyr-050gyr998-t-436-2025",
      "nombre_procedimiento": "AA-50-GYR-050GYR998-T-436-2025ADQUISICIÓN DE “TIRA REACTIVA” GRUPO 379 EQUIPOS,",
      "dependencia": "INSTITUTO MEXICANO DEL SEGURO SOCIAL",
      "siglas": "IMSS",
      "score": 0.1850641965866089
    }
  ]
}