{
  "html_url": "https://licitia.com.mx/adjudicacion/aa-50-gyr-050gyr060-t-205-2025",
  "canonical": "https://licitia.com.mx/adjudicacion/aa-50-gyr-050gyr060-t-205-2025",
  "id": "297d8ea245d448ed8ffcaf995d08e6c9",
  "procedure_number": "AA-50-GYR-050GYR060-T-205-2025",
  "file_number": "E-2025-00111241",
  "title": "ADJUDICACION MATERIAL DE CURACION",
  "description": {
    "short": "Contrataciones para atender una eventualidad por caso fortuito o de fuerza mayor, limitada a lo estrictamente necesario para afrontarla.",
    "detailed": "ADJUDICACION MATERIAL DE CURACION NEUROESTIMULADOR"
  },
  "lifecycle": {
    "section": "concluido",
    "source_status": "ADJUDICADO",
    "moved_at": null
  },
  "buyer": {
    "agency": "INSTITUTO MEXICANO DEL SEGURO SOCIAL",
    "acronym": "IMSS",
    "branch": "50 - INSTITUTO MEXICANO DEL SEGURO SOCIAL",
    "buying_unit": "UMAE HOSPITAL DE PEDIATRIA DEL CMNO, DEPARTAMENTO DE ABASTECIMIENTO Y EQUIPAMIENTO",
    "requesting_unit": "unidad requiriente data",
    "requesting_group": "UMAE HOSPITAL DE PEDIATRIA DEL CMNO, DEPARTAMENTO DE ABASTECIMIENTO Y EQUIPAMIENTO",
    "entity": null,
    "slug": "imss",
    "unit_slug": "umae-hospital-de-pediatria-del-cmno-departamento-de-abastecimiento-y-equipamiento-050gyr060"
  },
  "classification": {
    "procedure_type": "ADJUDICACIÓN DIRECTA",
    "contracting_type": "ADQUISICIONES",
    "publication_type": null,
    "character": "INTERNACIONAL BAJO LA COBERTURA DE TRATADOS",
    "fiscal_year": 2025,
    "law": "LEY DE ADQUISICIONES, ARRENDAMIENTOS Y SERVICIOS DEL SECTOR PÚBLICO",
    "legal_basis_id": "250",
    "exception_basis": "Art. 54 fr. V",
    "internal_control_number": "00317/2025",
    "supply_source_number": null
  },
  "schedule": {
    "published_at": "2026-07-28T15:15:58.000Z",
    "clarification_meeting_at": null,
    "clarification_questions_deadline_at": null,
    "clarification_responses_deadline_at": null,
    "bid_opening_at": null,
    "award_at": null,
    "estimated_contract_at": "2026-07-31T06:00:00.000Z",
    "site_visit_at": null,
    "estimated_work_start_at": null
  },
  "estimated_value": {
    "minimum": null,
    "maximum": null,
    "currency": "MXN",
    "updated_at": null
  },
  "lots": [
    {
      "number": "1",
      "name": "PARTIDA SOLA",
      "description": "PARTIDA SOLA",
      "requirement_group_id": "1",
      "items": [
        {
          "number": "1",
          "cucop_code": "25401-0001",
          "specific_item_code": "25401",
          "cucop_description": "ABATELENGUAS",
          "description": "060.345.3440.00.01 SISTEMA DE NEUROESTIMULACION IMPLANTABLE DEL NERVIO VAGO PARA EL TRATAMIENTO DE EPILEPSIA. EQUIPO IMPLANTABLE QUIRURGICAMENTE, OPERADO POR MICROPROCESADOR PARAEL TRATAMIENTO DE EPILEPSIA REFRACTARIA. CONSTA DE LOS SIGUIENTES ELEMENTOS: GENERADOR DE CORRIENTE OPERADO POR MICROPOCESADOR,  PROGRAMABLE PARA RESPONDERA ESTIMULACION TRANSCUTANEA, CABLE BIPOLAR CON ELECTRODOS Y ASAS PARA FIJACIONA NERVIO VAGO; OPERADO POR BATERIA; CAPACIDAD PARA PROGRAMAR FRECUENCIA DE LA SENAL, DURACION DEL IMPULSO, DURACION E INTERVALO DE LOS TRENES DE IMPULSO,TIEMPO E INICIO DEL TRATAMIENTO . CATETER CON CABLE PARA ESTIMULACION. LAS ESPECIFICACIONES DE CADA UNO DE LOS ELEMENTOS SEÑALADOS, SERAN DETERMINADAS POR LAS UNIDADES MEDICAS DE ACUERDO A SUS NECESIDADES. REFACCIONES: LAS UNIDADES MÉDICAS SELECCIONARÁN DE ACUERDO A SUS NECESIDADES, ASEGURANDO SU COMPATIBILIDAD CON LA MARCA Y MODELO DEL EQUIPO: MAGNETO ESTIMULADOR; INSTRUMENTO TUNELIZADOR CON CUBIERTA; BATERÍA ACCESORIOS OPCIONALES: LAS UNIDADES MEDICAS SELECCIONARAN DE ACUERDO A SUS NECESIDADES, ASEGURANDO SU COMPATIBILIDAD CON LA MARCA Y MODELO DEL EQUIPO: COMPUTADORA Y SOFTWARE.CATETER CON CABLE PARA ESTIMULACION. DESARMADORES Y CONECTORES. REFACCIONES: LAS UNIDADES MEDICAS SELECCIONARAN DE ACUERDO A SUS NECESIDADES, ASEGURANDO SU COMPATIBILIDAD CON LA MARCA Y MODELO DEL EQUIPO: MAGNETO ESTIMULADOR. INSTRUMENTO TUNELIZADOR CON CUBIERTA: BATERIA. CONSUMIBLES: LAS UNIDADES MEDICAS SELECCIONARAN DE ACUERDO A SUS NECESIDADES, ASEGURANDO SU COMPATIBILIDAD CON LA MARCA Y MODELO DEL EQUIPO: ACEITE MINERAL ESTERIL. INSTALACION: NO REQUIERE; OPERACION: POR PERSONAL ESPECIALIZADO Y DE ACUERDO ALMANUAL DE OPERACION; MANUALES Y PROGRAMAS EN ESPANOL. MANTENIMIENTO: PREVENTIVO. CORRECTIVO POR PERSONAL CALIFICADO.",
          "requested_quantity": null,
          "minimum_quantity": null,
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": "240000",
          "maximum_amount": "600000"
        }
      ]
    }
  ],
  "awards": [
    {
      "id": "C-2026-00072774",
      "internal_reference": "D5P0061",
      "title": "ADJUDICACION MATERIAL DE CURACION",
      "status": "PUBLICADO",
      "contractor": {
        "name": "ARTROSA SA DE CV",
        "normalized_name": "ARTROSA",
        "rfc_type": null,
        "slug": "artrosa"
      },
      "contract_period": {
        "published_at": "2026-07-28T20:06:59.000Z",
        "starts_at": "2025-11-27T06:00:00.000Z",
        "ends_at": "2025-12-05T06:00:00.000Z"
      },
      "value": {
        "subtotal": "600000",
        "tax": "96000",
        "total": "696000",
        "maximum_subtotal": "0",
        "maximum_total": "0",
        "currency": "MXN"
      },
      "open_contract_type": null,
      "quantity": null,
      "exercised_quantity": null,
      "participants": [],
      "line_items": [
        {
          "number": "0",
          "cucop_code": "25401-0001",
          "description": "060.345.3440.00.01 SISTEMA DE NEUROESTIMULACION IMPLANTABLE DEL NERVIO VAGO PARA EL TRATAMIENTO DE EPILEPSIA. EQUIPO IMPLANTABLE QUIRURGICAMENTE, OPERADO POR MICROPROCESADOR PARAEL TRATAMIENTO DE EPILEPSIA REFRACTARIA. CONSTA DE LOS SIGUIENTES ELEMENTOS: GENERADOR DE CORRIENTE OPERADO POR MICROPOCESADOR,  PROGRAMABLE PARA RESPONDERA ESTIMULACION TRANSCUTANEA, CABLE BIPOLAR CON ELECTRODOS Y ASAS PARA FIJACIONA NERVIO VAGO; OPERADO POR BATERIA; CAPACIDAD PARA PROGRAMAR FRECUENCIA DE LA SENAL, DURACION DEL IMPULSO, DURACION E INTERVALO DE LOS TRENES DE IMPULSO,TIEMPO E INICIO DEL TRATAMIENTO . CATETER CON CABLE PARA ESTIMULACION. LAS ESPECIFICACIONES DE CADA UNO DE LOS ELEMENTOS SEÑALADOS, SERAN DETERMINADAS POR LAS UNIDADES MEDICAS DE ACUERDO A SUS NECESIDADES. REFACCIONES: LAS UNIDADES MÉDICAS SELECCIONARÁN DE ACUERDO A SUS NECESIDADES, ASEGURANDO SU COMPATIBILIDAD CON LA MARCA Y MODELO DEL EQUIPO: MAGNETO ESTIMULADOR; INSTRUMENTO TUNELIZADOR CON CUBIERTA; BATERÍA ACCESORIOS OPCIONALES: LAS UNIDADES MEDICAS SELECCIONARAN DE ACUERDO A SUS NECESIDADES, ASEGURANDO SU COMPATIBILIDAD CON LA MARCA Y MODELO DEL EQUIPO: COMPUTADORA Y SOFTWARE.CATETER CON CABLE PARA ESTIMULACION. DESARMADORES Y CONECTORES. REFACCIONES: LAS UNIDADES MEDICAS SELECCIONARAN DE ACUERDO A SUS NECESIDADES, ASEGURANDO SU COMPATIBILIDAD CON LA MARCA Y MODELO DEL EQUIPO: MAGNETO ESTIMULADOR. INSTRUMENTO TUNELIZADOR CON CUBIERTA: BATERIA. CONSUMIBLES: LAS UNIDADES MEDICAS SELECCIONARAN DE ACUERDO A SUS NECESIDADES, ASEGURANDO SU COMPATIBILIDAD CON LA MARCA Y MODELO DEL EQUIPO: ACEITE MINERAL ESTERIL. INSTALACION: NO REQUIERE; OPERACION: POR PERSONAL ESPECIALIZADO Y DE ACUERDO ALMANUAL DE OPERACION; MANUALES Y PROGRAMAS EN ESPANOL. MANTENIMIENTO: PREVENTIVO. CORRECTIVO POR PERSONAL CALIFICADO.",
          "unit": "PIEZA",
          "requested_quantity": null,
          "awarded_quantity": null,
          "unit_price": "600000",
          "subtotal": "600000",
          "tax": "96000",
          "other_taxes": null,
          "total": "696000"
        }
      ]
    }
  ],
  "documents": [
    {
      "id": "72049b70-d2bc-49e9-90cb-f8bff1800d29",
      "annex_number": 1,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "ANEXO.pdf",
      "availability": "available",
      "size_bytes": "1514388",
      "mime_type": "application/pdf",
      "sha256": "d13b2f05b7690f049564f31ceee12b9988411ebc6b0044f825391dc863d3bc11",
      "uploaded_at": "2026-08-08T01:05:39.327Z",
      "updated_at": "2026-08-08T01:05:39.327Z"
    },
    {
      "id": "a5dcd668-05d3-4596-9a9c-9468c004fc6b",
      "annex_number": 1,
      "document_type": null,
      "description": "JUSTIFICACIÓN DE EXCEPCIÓN",
      "filename": "DICT EXCP.pdf",
      "availability": "available",
      "size_bytes": "920093",
      "mime_type": "application/pdf",
      "sha256": "c5b60d03349be6d48e16e9634be7fd726737bea7b9f9938a62687edc7036f1df",
      "uploaded_at": "2026-08-08T01:05:40.581Z",
      "updated_at": "2026-08-08T01:05:40.581Z"
    },
    {
      "id": "99e35021-7974-41bb-8c8b-5b2e4f6adcec",
      "annex_number": 6,
      "document_type": null,
      "description": "OFICIO DE NOTIFICACIÓN DE ADJUDICACIÓN",
      "filename": "ACTA T-205.pdf",
      "availability": "available",
      "size_bytes": "603274",
      "mime_type": "application/pdf",
      "sha256": "f47419aa5b170d251e00f66d9e6c73ca3657b41e6a27c68fd88f135a62200c13",
      "uploaded_at": "2026-08-08T01:05:42.378Z",
      "updated_at": "2026-08-08T01:05:42.379Z"
    }
  ],
  "alternates": [],
  "similar": []
}