  "html_url": "https://licitia.com.mx/adjudicacion/aa-50-gyr-050gyr067-t-20-2025",
  "canonical": "https://licitia.com.mx/adjudicacion/aa-50-gyr-050gyr067-t-20-2025",
  "id": "f44a1979a98a4ca7b03bd5f8b51528c8",
  "procedure_number": "AA-50-GYR-050GYR067-T-20-2025",
  "file_number": "E-2025-00013567",
  "title": "ADQUISICION DE INSUMOS GPO.379 NEUROESTIMULADOR FEBRERO 2025",
  "description": {
    "short": "Adquisiciones, arrendamientos y servicios, dentro de los montos máximos establecidos en el PEF.",
    "detailed": "379 646 0016 00 01 NEUROESTIMULADOR IMPLANTABLE (GENERADOR DE PULSOS), NO RECARGABLE, DE DOS CANALES MULTIPROGRAMABLE. PARAMETROS FISICOS: ALTURA 70.9 MM, LONGITUD 49.5 MM, GROSOR 11.3 MM, PESO 55 GRAMOS, VOLUMEN 33 CM3. TIPO DE CONECTOR OCTAPOLAR POR CANAL. CARCASA DE TITANIO. ESTERIL. PRESENTACION: PIEZA. NUMERO DE CATALOGO: M365DB11400. PARA SU USO EN EL DISPOSITIVO: SISTEMA DE NEUROESTIMULACION IMPLANTABLE PARA DESORDENES DE MOVIMIENTOS DE PARKINSON. CLAVE: 060.345.3408. MARCA: BOSTON SCIENTIFIC. MODELO: VERCISE.\n379 304 7212 00 01 ELECTRODO CON DIRECCIONALIDAD PARA ESTIMULACION CEREBRAL PROFUNDA, OCTAPOLAR, CON POLOS DE 1.5 MM DE LONGITUD Y 0.5 MM DE SEPARACION. LONGITUD TOTAL: 45 CM. LONGITUD PARTE DISTAL (8 POLOS): 7.5 MM. DIAMETRO EXTERNO: 1.3 MM. MARCADOR RADIOPACO EN PARTE DISTAL. ENTRADA OCTAPOLAR. ESTERIL. PRESENTACION: PIEZA. NUMERO DE CATALOGO: M365DB2202450. PARA SU USO EN EL DISPOSITIVO: SISTEMA DE NEUROESTIMULACION IMPLANTABLE PARA DESORDENES DE MOVIMIENTOS DE PARKINSON. CLAVE: 060.345.3408. MARCA: BOSTON SCIENTIFIC. MODELO: VERCISE.\n379 334 0104 00 01 EXTENSION DE NEUROESTIMULADOR IMPLANTABLE DE TRANSTORNOS DE MOVIMIENTO. LONGITUD TOTAL: 55 CM. CONECTOR DISTAL OCTAPOLAR EN LINEA, ESPACIO ENTRE CONTACTOS DE 1.5 MM. CONECTOR EXTREMO PROXIMAL (NEUROESTIMULADOR) OCTAPOLAR EN LINEA, ESPACIO ENTRE CONTACTOS 1.5 MM, DIAMETRO EXTERIOR 1.35 MM. ESTERIL. PRESENTACION: PIEZA. NUMERO DE CATALOGO: M365NM3138550. PARA SU USO EN EL DISPOSITIVO: SISTEMA DE NEUROESTIMULACION IMPLANTABLE PARA DESORDENES DE MOVIMIENTOS DE PARKINSON. CLAVE: 060.345.3408. MARCA: BOSTON SCIENTIFIC. MODELO: VERCISE.\n379 252 0417 00 01 CUBIERTA DE TREPANO Y SISTEMA DE ANCLAJE DE ELECTRODO SURETEK. INCLUYE: 1 BASE DE CUBIERTA PARA TREPANO, 2 TORNILLOS PARA HUESO, DESTORNILLADOR PARA TORNILLOS, 1 CLIP PARA ANCLAJE DE ELECTRODO, 1 CUBIERTA DE TREPANO Y 1 FIJADOR CON EXTREMO EN FORMA DE \"C\" PARA COLOCACION DE CUBIERTA, PRESENTACION: PIEZA. NUMERO DE CATALOGO: M365DB4600C0. PARA SU USO EN EL D"
  },
  "lifecycle": {
    "section": "concluido",
    "source_status": "ADJUDICADO",
    "moved_at": null
  },
  "buyer": {
    "agency": "IMSS",
    "acronym": "IMSS",
    "branch": "50 - INSTITUTO MEXICANO DEL SEGURO SOCIAL",
    "buying_unit": "UMAE HOSPITAL DE PEDIATRÍA SILVESTRE FRENK FREUND DEL CMN SIGLO XXI",
    "requesting_unit": "unidad requiriente data",
    "requesting_group": "UMAE HOSPITAL DE PEDIATRÍA SILVESTRE FRENK FREUND DEL CMN SIGLO XXI",
    "entity": null,
    "slug": "imss",
    "unit_slug": "umae-hospital-de-pediatria-silvestre-frenk-freund-del-cmn-siglo-xxi-050gyr067"
  },
  "classification": {
    "procedure_type": "ADJUDICACIÓN DIRECTA",
    "contracting_type": "ADQUISICIONES",
    "publication_type": null,
    "character": "INTERNACIONAL BAJO LA COBERTURA DE TRATADOS",
    "fiscal_year": 2025,
    "law": "LEY DE ADQUISICIONES, ARRENDAMIENTOS Y SERVICIOS DEL SECTOR PÚBLICO",
    "legal_basis_id": "42",
    "exception_basis": "Art. 42 párrafo primero",
    "internal_control_number": "AA-50-GYR-050GYR067-T-XX-2025",
    "supply_source_number": null
  },
  "schedule": {
    "published_at": "2025-02-19T18:33:19.000Z",
    "clarification_meeting_at": null,
    "clarification_questions_deadline_at": null,
    "clarification_responses_deadline_at": null,
    "bid_opening_at": null,
    "award_at": null,
    "estimated_contract_at": "2025-02-20T06:00:00.000Z",
    "site_visit_at": null,
    "estimated_work_start_at": null
  },
  "estimated_value": {
    "minimum": null,
    "maximum": null,
    "currency": "MXN",
    "updated_at": null
  },
  "lots": [
    {
      "number": "1",
      "name": "PARTIDA SOLA",
      "description": "PARTIDA SOLA",
      "requirement_group_id": "1",
      "items": [
        {
          "number": "1",
          "cucop_code": "53101-0160",
          "specific_item_code": "53101",
          "cucop_description": "ESTIMULADOR NERVIOS (EQUIPO MEDICO QUIRURGICO)",
          "description": "379 646 0016 00 01 NEUROESTIMULADOR IMPLANTABLE (GENERADOR DE PULSOS), NO RECARGABLE, DE DOS CANALES MULTIPROGRAMABLE. PARAMETROS FISICOS: ALTURA 70.9 MM, LONGITUD 49.5 MM, GROSOR 11.3 MM, PESO 55 GRAMOS, VOLUMEN 33 CM3. TIPO DE CONECTOR OCTAPOLAR POR CANAL. CARCASA DE TITANIO. ESTERIL. PRESENTACION: PIEZA. NUMERO DE CATALOGO: M365DB11400. PARA SU USO EN EL DISPOSITIVO: SISTEMA DE NEUROESTIMULACION IMPLANTABLE PARA DESORDENES DE MOVIMIENTOS DE PARKINSON. CLAVE: 060.345.3408. MARCA: BOSTON SCIENTIFIC. MODELO: VERCISE.",
          "requested_quantity": "1",
          "minimum_quantity": "1",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "2",
          "cucop_code": "53101-0160",
          "specific_item_code": "53101",
          "cucop_description": "ESTIMULADOR NERVIOS (EQUIPO MEDICO QUIRURGICO)",
          "description": "379 304 7212 00 01 ELECTRODO CON DIRECCIONALIDAD PARA ESTIMULACION CEREBRAL PROFUNDA, OCTAPOLAR, CON POLOS DE 1.5 MM DE LONGITUD Y 0.5 MM DE SEPARACION. LONGITUD TOTAL: 45 CM. LONGITUD PARTE DISTAL (8 POLOS): 7.5 MM. DIAMETRO EXTERNO: 1.3 MM. MARCADOR RADIOPACO EN PARTE DISTAL. ENTRADA OCTAPOLAR. ESTERIL. PRESENTACION: PIEZA. NUMERO DE CATALOGO: M365DB2202450. PARA SU USO EN EL DISPOSITIVO: SISTEMA DE NEUROESTIMULACION IMPLANTABLE PARA DESORDENES DE MOVIMIENTOS DE PARKINSON. CLAVE: 060.345.3408. MARCA: BOSTON SCIENTIFIC. MODELO: VERCISE.",
          "requested_quantity": "2",
          "minimum_quantity": "2",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "3",
          "cucop_code": "53101-0160",
          "specific_item_code": "53101",
          "cucop_description": "ESTIMULADOR NERVIOS (EQUIPO MEDICO QUIRURGICO)",
          "description": "379 334 0104 00 01 EXTENSION DE NEUROESTIMULADOR IMPLANTABLE DE TRANSTORNOS DE MOVIMIENTO. LONGITUD TOTAL: 55 CM. CONECTOR DISTAL OCTAPOLAR EN LINEA, ESPACIO ENTRE CONTACTOS DE 1.5 MM. CONECTOR EXTREMO PROXIMAL (NEUROESTIMULADOR) OCTAPOLAR EN LINEA, ESPACIO ENTRE CONTACTOS 1.5 MM, DIAMETRO EXTERIOR 1.35 MM. ESTERIL. PRESENTACION: PIEZA. NUMERO DE CATALOGO: M365NM3138550. PARA SU USO EN EL DISPOSITIVO: SISTEMA DE NEUROESTIMULACION IMPLANTABLE PARA DESORDENES DE MOVIMIENTOS DE PARKINSON. CLAVE: 060.345.3408. MARCA: BOSTON SCIENTIFIC. MODELO: VERCISE.",
          "requested_quantity": "2",
          "minimum_quantity": "2",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "4",
          "cucop_code": "53101-0160",
          "specific_item_code": "53101",
          "cucop_description": "ESTIMULADOR NERVIOS (EQUIPO MEDICO QUIRURGICO)",
          "description": "379 252 0417 00 01 CUBIERTA DE TREPANO Y SISTEMA DE ANCLAJE DE ELECTRODO SURETEK. INCLUYE: 1 BASE DE CUBIERTA PARA TREPANO, 2 TORNILLOS PARA HUESO, DESTORNILLADOR PARA TORNILLOS, 1 CLIP PARA ANCLAJE DE ELECTRODO, 1 CUBIERTA DE TREPANO Y 1 FIJADOR CON EXTREMO EN FORMA DE \"C\" PARA COLOCACION DE CUBIERTA, PRESENTACION: PIEZA. NUMERO DE CATALOGO: M365DB4600C0. PARA SU USO EN EL DISPOSITIVO: SISTEMA DE NEUROESTIMULACION IMPLANTABLE PARA DESORDENES DE MOVIMIENTOS DE PARKINSON. CLAVE: 060.345.3408. MARCA: BOSTON SCIENTIFIC. MODELO: VERCISE.",
          "requested_quantity": "2",
          "minimum_quantity": "2",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "5",
          "cucop_code": "53101-0160",
          "specific_item_code": "53101",
          "cucop_description": "ESTIMULADOR NERVIOS (EQUIPO MEDICO QUIRURGICO)",
          "description": "379 817 0209 00 01 SISTEMA DE RECARGA PARA NEUROESTIMULADOR RECARGABLE. INCLUYE CARGADOR INALAMBRICO, ESTACION BASE CON CABLE ADAPTADOR PARA CARGADOR INALAMBRICO, 2 COLLARINES EN TAMAÑO PEQUEÑO Y MEDIANO. PRESENTACION: PIEZA. NUMERO DE CATALOGO: M365DB6412EUC0. PARA SU USO EN EL DISPOSITIVO: SISTEMA DE NEUROESTIMULACION IMPLANTABLE PARA DESORDENES DE MOVIMIENTOS DE PARKINSON. CLAVE: 060.345.3408. MARCA: BOSTON SCIENTIFIC. MODELO: VERCISE.",
          "requested_quantity": "1",
          "minimum_quantity": "1",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "6",
          "cucop_code": "53101-0160",
          "specific_item_code": "53101",
          "cucop_description": "ESTIMULADOR NERVIOS (EQUIPO MEDICO QUIRURGICO)",
          "description": "379 231 6816 00 01 CONTROL REMOTO PARA EL NEUROESTIMULADOR NO RECARGABLE. PARA ENCENDIDO Y APAGADO DEL NEUROESTIMULADOR. INALAMBRICO. PARAMETROS FISICOS: ALTURA 12.4 CM, LONGITUD 5 CM, GROSOR 2 CM. INCLUYE ESTUCHE PROTECTOR, ESTUCHE PORTACONTROL Y CABLE USB PARA RECARGA DEL CONTROL REMOTO. PRESENTACION: PIEZA. NUMERO DE CATALOGO: M365DB55421A0. PARA SU USO EN EL DISPOSITIVO: SISTEMA DE NEUROESTIMULACION IMPLANTABLE PARA DESORDENES DE MOVIMIENTOS DE PARKINSON. CLAVE: 060.345.3408. MARCA: BOSTON SCIENTIFIC. MODELO: VERCISE.",
          "requested_quantity": "1",
          "minimum_quantity": "1",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        }
      ]
    }
  ],
  "awards": [
    {
      "id": "C-2025-00012554",
      "internal_reference": "D5P0003; 050GYR067A000325-003",
      "title": "ADQUISICION DE INSUMOS GPO.379 NEUROESTIMULADOR FEBRERO 2025",
      "status": "PUBLICADO",
      "contractor": {
        "name": "BOSTON SCIENTIFIC DE MEXICO SA DE CV",
        "normalized_name": "BOSTON SCIENTIFIC DE MEXICO",
        "rfc_type": null,
        "slug": "boston-scientific-de-mexico"
      },
      "contract_period": {
        "published_at": "2025-02-19T18:33:19.000Z",
        "starts_at": "2025-02-20T06:00:00.000Z",
        "ends_at": "2025-03-01T06:00:00.000Z"
      },
      "value": {
        "subtotal": "395000",
        "tax": "63200",
        "total": "458200",
        "maximum_subtotal": "0",
        "maximum_total": "0",
        "currency": "MXN"
      },
      "open_contract_type": null,
      "quantity": null,
      "exercised_quantity": null,
      "participants": [],
      "line_items": [
        {
          "number": "0",
          "cucop_code": "53101-0160",
          "description": "379 646 0016 00 01 NEUROESTIMULADOR IMPLANTABLE (GENERADOR DE PULSOS), NO RECARGABLE, DE DOS CANALES MULTIPROGRAMABLE. PARAMETROS FISICOS: ALTURA 70.9 MM, LONGITUD 49.5 MM, GROSOR 11.3 MM, PESO 55 GRAMOS, VOLUMEN 33 CM3. TIPO DE CONECTOR OCTAPOLAR POR CANAL. CARCASA DE TITANIO. ESTERIL. PRESENTACION: PIEZA. NUMERO DE CATALOGO: M365DB11400. PARA SU USO EN EL DISPOSITIVO: SISTEMA DE NEUROESTIMULACION IMPLANTABLE PARA DESORDENES DE MOVIMIENTOS DE PARKINSON. CLAVE: 060.345.3408. MARCA: BOSTON SCIENTIFIC. MODELO: VERCISE.",
          "unit": "PIEZA",
          "requested_quantity": "1",
          "awarded_quantity": null,
          "unit_price": "150000",
          "subtotal": "150000",
          "tax": "24000",
          "other_taxes": null,
          "total": "174000"
        },
        {
          "number": "0",
          "cucop_code": "53101-0160",
          "description": "379 304 7212 00 01 ELECTRODO CON DIRECCIONALIDAD PARA ESTIMULACION CEREBRAL PROFUNDA, OCTAPOLAR, CON POLOS DE 1.5 MM DE LONGITUD Y 0.5 MM DE SEPARACION. LONGITUD TOTAL: 45 CM. LONGITUD PARTE DISTAL (8 POLOS): 7.5 MM. DIAMETRO EXTERNO: 1.3 MM. MARCADOR RADIOPACO EN PARTE DISTAL. ENTRADA OCTAPOLAR. ESTERIL. PRESENTACION: PIEZA. NUMERO DE CATALOGO: M365DB2202450. PARA SU USO EN EL DISPOSITIVO: SISTEMA DE NEUROESTIMULACION IMPLANTABLE PARA DESORDENES DE MOVIMIENTOS DE PARKINSON. CLAVE: 060.345.3408. MARCA: BOSTON SCIENTIFIC. MODELO: VERCISE.",
          "unit": "PIEZA",
          "requested_quantity": "2",
          "awarded_quantity": null,
          "unit_price": "44100",
          "subtotal": "88200",
          "tax": "14112",
          "other_taxes": null,
          "total": "102312"
        },
        {
          "number": "0",
          "cucop_code": "53101-0160",
          "description": "379 334 0104 00 01 EXTENSION DE NEUROESTIMULADOR IMPLANTABLE DE TRANSTORNOS DE MOVIMIENTO. LONGITUD TOTAL: 55 CM. CONECTOR DISTAL OCTAPOLAR EN LINEA, ESPACIO ENTRE CONTACTOS DE 1.5 MM. CONECTOR EXTREMO PROXIMAL (NEUROESTIMULADOR) OCTAPOLAR EN LINEA, ESPACIO ENTRE CONTACTOS 1.5 MM, DIAMETRO EXTERIOR 1.35 MM. ESTERIL. PRESENTACION: PIEZA. NUMERO DE CATALOGO: M365NM3138550. PARA SU USO EN EL DISPOSITIVO: SISTEMA DE NEUROESTIMULACION IMPLANTABLE PARA DESORDENES DE MOVIMIENTOS DE PARKINSON. CLAVE: 060.345.3408. MARCA: BOSTON SCIENTIFIC. MODELO: VERCISE.",
          "unit": "PIEZA",
          "requested_quantity": "2",
          "awarded_quantity": null,
          "unit_price": "25000",
          "subtotal": "50000",
          "tax": "8000",
          "other_taxes": null,
          "total": "58000"
        },
        {
          "number": "0",
          "cucop_code": "53101-0160",
          "description": "379 252 0417 00 01 CUBIERTA DE TREPANO Y SISTEMA DE ANCLAJE DE ELECTRODO SURETEK. INCLUYE: 1 BASE DE CUBIERTA PARA TREPANO, 2 TORNILLOS PARA HUESO, DESTORNILLADOR PARA TORNILLOS, 1 CLIP PARA ANCLAJE DE ELECTRODO, 1 CUBIERTA DE TREPANO Y 1 FIJADOR CON EXTREMO EN FORMA DE \"C\" PARA COLOCACION DE CUBIERTA, PRESENTACION: PIEZA. NUMERO DE CATALOGO: M365DB4600C0. PARA SU USO EN EL DISPOSITIVO: SISTEMA DE NEUROESTIMULACION IMPLANTABLE PARA DESORDENES DE MOVIMIENTOS DE PARKINSON. CLAVE: 060.345.3408. MARCA: BOSTON SCIENTIFIC. MODELO: VERCISE.",
          "unit": "PIEZA",
          "requested_quantity": "2",
          "awarded_quantity": null,
          "unit_price": "30170",
          "subtotal": "60340",
          "tax": "9654.4",
          "other_taxes": null,
          "total": "69994.4"
        },
        {
          "number": "0",
          "cucop_code": "53101-0160",
          "description": "379 817 0209 00 01 SISTEMA DE RECARGA PARA NEUROESTIMULADOR RECARGABLE. INCLUYE CARGADOR INALAMBRICO, ESTACION BASE CON CABLE ADAPTADOR PARA CARGADOR INALAMBRICO, 2 COLLARINES EN TAMAÑO PEQUEÑO Y MEDIANO. PRESENTACION: PIEZA. NUMERO DE CATALOGO: M365DB6412EUC0. PARA SU USO EN EL DISPOSITIVO: SISTEMA DE NEUROESTIMULACION IMPLANTABLE PARA DESORDENES DE MOVIMIENTOS DE PARKINSON. CLAVE: 060.345.3408. MARCA: BOSTON SCIENTIFIC. MODELO: VERCISE.",
          "unit": "PIEZA",
          "requested_quantity": "1",
          "awarded_quantity": null,
          "unit_price": "23230",
          "subtotal": "23230",
          "tax": "3716.8",
          "other_taxes": null,
          "total": "26946.8"
        },
        {
          "number": "0",
          "cucop_code": "53101-0160",
          "description": "379 231 6816 00 01 CONTROL REMOTO PARA EL NEUROESTIMULADOR NO RECARGABLE. PARA ENCENDIDO Y APAGADO DEL NEUROESTIMULADOR. INALAMBRICO. PARAMETROS FISICOS: ALTURA 12.4 CM, LONGITUD 5 CM, GROSOR 2 CM. INCLUYE ESTUCHE PROTECTOR, ESTUCHE PORTACONTROL Y CABLE USB PARA RECARGA DEL CONTROL REMOTO. PRESENTACION: PIEZA. NUMERO DE CATALOGO: M365DB55421A0. PARA SU USO EN EL DISPOSITIVO: SISTEMA DE NEUROESTIMULACION IMPLANTABLE PARA DESORDENES DE MOVIMIENTOS DE PARKINSON. CLAVE: 060.345.3408. MARCA: BOSTON SCIENTIFIC. MODELO: VERCISE.",
          "unit": "PIEZA",
          "requested_quantity": "1",
          "awarded_quantity": null,
          "unit_price": "23230",
          "subtotal": "23230",
          "tax": "3716.8",
          "other_taxes": null,
          "total": "26946.8"
        }
      ]
    }
  ],
  "documents": [
    {
      "id": null,
      "annex_number": 1,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "Anexo Tecnico.pdf",
      "availability": "available",
      "size_bytes": "1599286",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-11-03T20:13:30.967Z",
      "updated_at": "2025-11-03T20:13:30.968Z"
    },
    {
      "id": null,
      "annex_number": 3,
      "document_type": null,
      "description": "OFICIO DE ADJUDICACIÓN",
      "filename": "AAT202025.pdf",
      "availability": "available",
      "size_bytes": "2564709",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-11-03T20:14:05.609Z",
      "updated_at": "2025-11-03T20:14:05.610Z"
    }
  ],
  "alternates": [],
  "similar": [
    {
      "numero_procedimiento": "aa-50-gyr-050gyr998-i-69-2025",
      "nombre_procedimiento": "AA-50-GYR-050GYR998-I-69-2025 EQUIPOS INSTRUMENTAL ACCESORIOS MEDICOS GRUPO 379",
      "dependencia": "IMSS",
      "siglas": "IMSS",
      "score": 0.059904459709193225
    },
    {
      "numero_procedimiento": "aa-50-gyr-050gyr998-t-161-2024",
      "nombre_procedimiento": "AA-50-GYR-050GYR998-T-161-2024 SISTEMA DE NEUROESTIMULACIÓN IMPLANTABLE PARA DES",
      "dependencia": "INSTITUTO MEXICANO DEL SEGURO SOCIAL",
      "siglas": "IMSS",
      "score": 0.07008736907914892
    },
    {
      "numero_procedimiento": "aa-50-gyr-050gyr998-i-132-2025",
      "nombre_procedimiento": "AA-50-GYR-050GYR998-I-132-2025",
      "dependencia": "IMSS",
      "siglas": "IMSS",
      "score": 0.0712845964005332
    },
    {
      "numero_procedimiento": "aa-50-gyr-050gyr998-i-63-2025",
      "nombre_procedimiento": "AA-50-GYR-050GYR998-I-63-2025 EQUIPOS INSTRUMENTAL ACCESORIOS MEDICOS GRUPO 379",
      "dependencia": "IMSS",
      "siglas": "IMSS",
      "score": 0.07728391885757446
    },
    {
      "numero_procedimiento": "aa-50-gyr-050gyr998-t-484-2023",
      "nombre_procedimiento": "AA-50-GYR-050GYR998-T-484-2023  ADQUISICION DE CLAVES DEL GRUPO 526",
      "dependencia": "IMSS",
      "siglas": "IMSS",
      "score": 0.07808160781860352
    },
    {
      "numero_procedimiento": "aa-50-gyr-050gyr045-t-114-2023",
      "nombre_procedimiento": "ADQ. SISTEMA DE NEUROESTIMULACION IMPLANTABLE",
      "dependencia": "IMSS",
      "siglas": "IMSS",
      "score": 0.11487722396850586
    }
  ]
}