  "html_url": "https://licitia.com.mx/adjudicacion/aa-70-044-911056968-n-1-2023",
  "canonical": "https://licitia.com.mx/adjudicacion/aa-70-044-911056968-n-1-2023",
  "id": "b5b6c7fb10df47478600df7b9915a9f7",
  "procedure_number": "AA-70-044-911056968-N-1-2023",
  "file_number": "E-2023-00075518",
  "title": "CROMATÓGRAFO DE LÍQUIDOS",
  "description": {
    "short": "No existen bienes alternativos o sustitutos, Único Oferente, Derechos exclusivos (patentes, licencias, derechos de autor u otros derechos exclusivos), o por obras de arte.",
    "detailed": "ADQUISICIÓN DE CROMATÓGRAFO DE LÍQUIDOS DE ULTRA-ALTA RESOLUCIO N UHPLC MARCA AGILENT TECHNOLOGIES MODELO 1290 SERIE II, INCLUYE:\n1.- ESPECTRÓMETRO DE MASAS DE ALTA RESOLUCIÓN QTOF MODELO 6546\n2.- AGILENT UHPLC 1290 INFINITY II FLEXIBLE PUMP\n3.- AGILENT UHPLC 1290 INFINITY II VIALSAMPLER\n4.- AGILENT 1290 INFINITY II COMPARTIMENTO TERMOSTATADO DE COLUMNAS\n5.-SELECTOR DE 4 COLUMNAS PARA CABEZA DE VÁLVULAS AGILENT DE INTERCAMBIO RÁPIDO DE 4\nPOSICIONES Y 10 PUERTOS, PARA SU USO CON EL TERMOSTATO MULTICOLUMNA\n6.- AGILENT 1290 INFINITY II DIODE ARRAY DETECTOR\n7.- GENERADOR DE NITRÓGENO\n8.- SISTEMA DE ENERGÍA ININTERRUMPIBLE\n9.- 959758-902 COLUMNA ECLIPSE PLUS C18 RRHP, 2,1 X 100 MM, 1,8 UM\n10.- 959759-902 COLUMNA ECLIPSE PLUS C18 RRHD, 2,1X150MM, 1,8UM\n11.- 695775-902 COLUMNA POROSHELL 120,EC-C18, 2,1X100MM,2,7UM\nSE INCLUYE LA INSTALACIÓN Y CAPACITACIÓN POR 40 HORAS PARA 4 PERSONAS.\nINCLUYE CALIFICACIÓN A LA INSTALACIÓN Y OPERACIÓN. (IQ Y OQ)"
  },
  "lifecycle": {
    "section": "concluido",
    "source_status": "ADJUDICADO",
    "moved_at": null
  },
  "buyer": {
    "agency": "FISCALÍA GENERAL DEL ESTADO DE GUANAJUATO",
    "acronym": "FGEGUANAJUATO",
    "branch": "70 - GUANAJUATO",
    "buying_unit": "UNIDAD DE ADMINISTRACIÓN Y PRESUPUESTACIÓN ESTRATÉGICA",
    "requesting_unit": "unidad requiriente data",
    "requesting_group": "UNIDAD DE ADMINISTRACIÓN Y PRESUPUESTACIÓN ESTRATÉGICA",
    "entity": "Fiscalía general del estado de guanajuato",
    "slug": "fgeguanajuato",
    "unit_slug": "unidad-de-administracion-y-presupuestacion-estrategica-911056968"
  },
  "classification": {
    "procedure_type": "ADJUDICACIÓN DIRECTA",
    "contracting_type": "ADQUISICIONES",
    "publication_type": null,
    "character": "NACIONAL",
    "fiscal_year": 2023,
    "law": "LEY DE ADQUISICIONES, ARRENDAMIENTOS Y SERVICIOS DEL SECTOR PÚBLICO",
    "legal_basis_id": "22",
    "exception_basis": "Art. 41 fr. I",
    "internal_control_number": "FGEG-AIC-114-2023",
    "supply_source_number": null
  },
  "schedule": {
    "published_at": "2023-08-24T16:08:28.000Z",
    "clarification_meeting_at": null,
    "clarification_questions_deadline_at": null,
    "clarification_responses_deadline_at": null,
    "bid_opening_at": null,
    "award_at": null,
    "estimated_contract_at": "2023-08-28T06:00:00.000Z",
    "site_visit_at": null,
    "estimated_work_start_at": null
  },
  "estimated_value": {
    "minimum": null,
    "maximum": null,
    "currency": "MXN",
    "updated_at": null
  },
  "lots": [
    {
      "number": "1",
      "name": "PARTIDA SOLA",
      "description": "PARTIDA SOLA",
      "requirement_group_id": "1",
      "items": [
        {
          "number": "1",
          "cucop_code": "53101-1222",
          "specific_item_code": "53101",
          "cucop_description": "533.274.0033 CROMATOGRAFOS. CROMATOGRAFO DE LIQUIDOS DE ALTA RESOLUCION. SISTEMA MODULAR CONSTITUIDO POR UNA BOMBA CONTROLADA MEDIANTE UN MICROPROCESADOR CON CAPACIDAD DE MANEJAR FLUJOS Y PRESIONES Y DE EDITAR Y ALMACENAR METODOS. CON LAS SIGUIENTES CARACTERISTICAS SELECCIONABLES DE ACUERDO A LAS NECESIDADES DE LAS UNIDADES MEDICAS: CAPACIDAD DE ACOPLAMIENTO A ESPECTROFOTOMETRO DE MASAS. MICROBOMBA ISOCRATICA BOMBA CUATERNARIA Y/O BINARIA. DESGASIFICADOR DE VACIO. AUTOMUESTREADOR AUTONOMO PARA MICROPLACAS Y/O CARRUSEL. INYECTOR AUTOMATICO. SISTEMA DE MUESTREO INDEPENDIENTE. ESPECTROFOTOMETRO DE MASAS. DETECTOR DE ARREGLO DE DIODOS. DETECTOR ULTRAVIOLETA/VISIBLE. DETECTOR DE FLUORESCENCIA. SISTEMA DE GENERACION DE GAS. COMPRESOR DE AIRE. CAMPANA DE EXTRACCION DE GASES. COLUMNAS CROMATOGRAFICAS.",
          "description": "CROMATÓGRAFO DE LÍQUIDOS DE ULTRA-ALTA RESOLUCIO N UHPLC MARCA AGILENT TECHNOLOGIES MODELO 1290 SERIE II, INCLUYE:\n1.- ESPECTRÓMETRO DE MASAS DE ALTA RESOLUCIÓN QTOF MODELO 6546\n2.- AGILENT UHPLC 1290 INFINITY II FLEXIBLE PUMP\n3.- AGILENT UHPLC 1290 INFINITY II VIALSAMPLER\n4.- AGILENT 1290 INFINITY II COMPARTIMENTO TERMOSTATADO DE COLUMNAS\n5.-SELECTOR DE 4 COLUMNAS PARA CABEZA DE VÁLVULAS AGILENT DE INTERCAMBIO RÁPIDO DE 4\nPOSICIONES Y 10 PUERTOS, PARA SU USO CON EL TERMOSTATO MULTICOLUMNA\n6.- AGILENT 1290 INFINITY II DIODE ARRAY DETECTOR\n7.- GENERADOR DE NITRÓGENO\n8.- SISTEMA DE ENERGÍA ININTERRUMPIBLE\n9.- 959758-902 COLUMNA ECLIPSE PLUS C18 RRHP, 2,1 X 100 MM, 1,8 UM\n10.- 959759-902 COLUMNA ECLIPSE PLUS C18 RRHD, 2,1X150MM, 1,8UM\n11.- 695775-902 COLUMNA POROSHELL 120,EC-C18, 2,1X100MM,2,7UM\nSE INCLUYE LA INSTALACIÓN Y CAPACITACIÓN POR 40 HORAS PARA 4 PERSONAS.\nINCLUYE CALIFICACIÓN A LA INSTALACIÓN Y OPERACIÓN. (IQ Y OQ)",
          "requested_quantity": "1",
          "minimum_quantity": "1",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        }
      ]
    }
  ],
  "awards": [
    {
      "id": "C-2023-00096449",
      "internal_reference": "FGEG-AIC-114-2023",
      "title": "CROMATÓGRAFO DE LÍQUIDOS",
      "status": "PUBLICADO",
      "contractor": {
        "name": "AGILENT TECHNOLOGIES MEXICO S DE RL DE CV",
        "normalized_name": "AGILENT TECHNOLOGIES MEXICO",
        "rfc_type": null,
        "slug": "agilent-technologies-mexico"
      },
      "contract_period": {
        "published_at": "2023-08-24T16:08:28.000Z",
        "starts_at": "2023-08-28T06:00:00.000Z",
        "ends_at": "2023-12-29T06:00:00.000Z"
      },
      "value": {
        "subtotal": "10794917.98",
        "tax": "1727186.87",
        "total": "12522104.85",
        "maximum_subtotal": "0",
        "maximum_total": "0",
        "currency": "MXN"
      },
      "open_contract_type": null,
      "quantity": null,
      "exercised_quantity": null,
      "participants": [],
      "line_items": [
        {
          "number": "0",
          "cucop_code": "53101-1222",
          "description": "CROMATÓGRAFO DE LÍQUIDOS DE ULTRA-ALTA RESOLUCIO N UHPLC MARCA AGILENT TECHNOLOGIES MODELO 1290 SERIE II, INCLUYE:\n1.- ESPECTRÓMETRO DE MASAS DE ALTA RESOLUCIÓN QTOF MODELO 6546\n2.- AGILENT UHPLC 1290 INFINITY II FLEXIBLE PUMP\n3.- AGILENT UHPLC 1290 INFINITY II VIALSAMPLER\n4.- AGILENT 1290 INFINITY II COMPARTIMENTO TERMOSTATADO DE COLUMNAS\n5.-SELECTOR DE 4 COLUMNAS PARA CABEZA DE VÁLVULAS AGILENT DE INTERCAMBIO RÁPIDO DE 4\nPOSICIONES Y 10 PUERTOS, PARA SU USO CON EL TERMOSTATO MULTICOLUMNA\n6.- AGILENT 1290 INFINITY II DIODE ARRAY DETECTOR\n7.- GENERADOR DE NITRÓGENO\n8.- SISTEMA DE ENERGÍA ININTERRUMPIBLE\n9.- 959758-902 COLUMNA ECLIPSE PLUS C18 RRHP, 2,1 X 100 MM, 1,8 UM\n10.- 959759-902 COLUMNA ECLIPSE PLUS C18 RRHD, 2,1X150MM, 1,8UM\n11.- 695775-902 COLUMNA POROSHELL 120,EC-C18, 2,1X100MM,2,7UM\nSE INCLUYE LA INSTALACIÓN Y CAPACITACIÓN POR 40 HORAS PARA 4 PERSONAS.\nINCLUYE CALIFICACIÓN A LA INSTALACIÓN Y OPERACIÓN. (IQ Y OQ)",
          "unit": "PIEZA",
          "requested_quantity": "1",
          "awarded_quantity": null,
          "unit_price": "10794917.88",
          "subtotal": "10794917.98",
          "tax": "1727186.87",
          "other_taxes": null,
          "total": "12522104.85"
        }
      ]
    }
  ],
  "documents": [
    {
      "id": null,
      "annex_number": 1,
      "document_type": null,
      "description": "JUSTIFICACIÓN DE EXCEPCIÓN",
      "filename": "FGEG-AIC-EL-008-2023.pdf",
      "availability": "available",
      "size_bytes": "858458",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-03T01:32:31.180Z",
      "updated_at": "2025-12-03T01:32:31.181Z"
    },
    {
      "id": null,
      "annex_number": 1,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "SOLICITUD DE PEDIDO 8000733.pdf",
      "availability": "available",
      "size_bytes": "596607",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-03T01:32:33.274Z",
      "updated_at": "2025-12-03T01:32:33.275Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "PEDIDO",
      "filename": "PEDIDO 48000979.pdf",
      "availability": "available",
      "size_bytes": "1604427",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-03T01:32:35.555Z",
      "updated_at": "2025-12-03T01:32:35.556Z"
    },
    {
      "id": null,
      "annex_number": 3,
      "document_type": null,
      "description": "OFERTA",
      "filename": "OFERTA 60001557.pdf",
      "availability": "available",
      "size_bytes": "3101732",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-03T01:32:39.758Z",
      "updated_at": "2025-12-03T01:32:39.760Z"
    },
    {
      "id": null,
      "annex_number": 6,
      "document_type": null,
      "description": "OFICIO DE ADJUDICACIÓN",
      "filename": "OFICIO DE ADJUDICACIÃ¿N DA-AIC-912-2023.pdf",
      "availability": "available",
      "size_bytes": "4216579",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-03T01:32:44.993Z",
      "updated_at": "2025-12-03T01:32:44.995Z"
    }
  ],
  "alternates": [],
  "similar": [
    {
      "numero_procedimiento": "aa-16-b00-016b00015-i-118-2026",
      "nombre_procedimiento": "PROGRAMA ADQUISICIÓN DE EQUIPOS PARA MEDICIONES (CROMATÓGRAFO GASES)",
      "dependencia": "COMISION NACIONAL DEL AGUA",
      "siglas": "CONAGUA",
      "score": 0.19770983484865634
    },
    {
      "numero_procedimiento": "aa-81-025-922062973-n-30-2026",
      "nombre_procedimiento": "CROMATÓGRAFO DE LIQUIDOS",
      "dependencia": "UNIVERSIDAD AUTÓNOMA DE QUERÉTARO",
      "siglas": "UAQ",
      "score": 0.19971065522964726
    },
    {
      "numero_procedimiento": "aa-08-b00-008b00001-n-40-2025",
      "nombre_procedimiento": "SERVICIO MANTENIMIENTO EQUIPOS LABORATORIO DIFERENTES ÁREAS CNRIBA (WATERS)",
      "dependencia": "SERVICIO NACIONAL DE SANIDAD, INOCUIDAD Y CALIDAD AGROALIMENTARIA",
      "siglas": "SENASICA",
      "score": 0.21484378620516587
    },
    {
      "numero_procedimiento": "aa-08-b00-008b00001-n-99-2025",
      "nombre_procedimiento": "SERVICIO MANTENIMIENTO EQUIPOS DE LABORATORIOS MARCA WATERS",
      "dependencia": "SENASICA",
      "siglas": "SENASICA",
      "score": 0.22255975008010864
    },
    {
      "numero_procedimiento": "aa-18-t0q-018t0q001-n-49-2023",
      "nombre_procedimiento": "ADQUISICION DE COLUMNAS ANALITICAS PARA HPLC",
      "dependencia": "ININ",
      "siglas": "ININ",
      "score": 0.22481738181010458
    },
    {
      "numero_procedimiento": "aa-10-lau-010lau001-n-157-2023",
      "nombre_procedimiento": "ADQUISICIÓN DE UN ESPECTRÓMETRO DE EMISIÓN ÓPTICA MARCA AGILENT.",
      "dependencia": "SERVICIO GEOLOGICO MEXICANO",
      "siglas": "SGM",
      "score": 0.22696180504332675
    }
  ]
}