  "title": "ADQUISICION DE ESPECTROFOTOMETRO",
  "description": {
    "short": "Razones justificadas para la adquisición o arrendamientos de bienes de marca determinada.",
    "detailed": "ESPECTROFOTOMETRO, MARCA UNICO, S-215OUV, UV/VIS\n1. ÓPTICA Y RANGO DE MEDICIÓN\n• RANGO DE LONGITUD DE ONDA: 200 NM A 1000 NM, LO QUE CUBRE TODAS LAS NECESIDADES PARA EL ANÁLISIS DE ANTIBIÓTICOS (COMO LAS PENICILINAS EN TU PROYECTO) Y ENSAYOS BIOLÓGICOS.\n• ANCHO DE BANDA ESPECTRAL: 4 NM. ES EL ESTÁNDAR IDEAL PARA ANÁLISIS CUANTITATIVOS, OFRECIENDO UN EQUILIBRIO ENTRE RESOLUCIÓN DE PICOS Y PASO DE LUZ.\n• SISTEMA ÓPTICO: HAZ ÚNICO (SINGLE BEAM) CON REJILLA DE DIFRACCIÓN DE 1200 LÍNEAS/MM.\n2. RENDIMIENTO Y PRECISIÓN\n• PRECISIÓN DE LONGITUD DE ONDA: $\\PM 1.0\\TEXT{ NM}$, ASEGURANDO QUE SIEMPRE MIDAS EN EL PICO MÁXIMO DE ABSORBANCIA DEL ANALITO.\n• REPETIBILIDAD DE LONGITUD DE ONDA: 0.5 NM.\n• LUZ DISPERSA (STRAY LIGHT): $\\LE 0.3\\% \\ T$ (MEDIDO A 220 NM Y 340 NM). ESTO ES VITAL PARA EVITAR ERRORES DE LECTURA EN CONCENTRACIONES ALTAS.\n• RANGO FOTOMÉTRICO:\nO ABSORBANCIA: -0.3 A 3.0 A.\nO TRANSMITANCIA: 0 A 200% T.\n3. FUENTES DE LUZ Y DETECCIÓN\n• LÁMPARAS: POSEE UN SISTEMA DUAL DE LÁMPARA DE DEUTERIO (D2) PARA EL RANGO UV Y LÁMPARA DE TUNGSTENO-HALÓGENO PARA EL RANGO VISIBLE.\n• DETECTOR: FOTODIODO DE SILICIO DE ALTA SENSIBILIDAD.\n• CAMBIO DE LÁMPARA: EL EQUIPO PERMITE CONFIGURAR EL PUNTO EXACTO DE INTERCAMBIO ENTRE LÁMPARAS (USUALMENTE A LOS 340 NM).\n4. FUNCIONES DE SOFTWARE INTEGRADAS\nEL PANEL DE CONTROL Y LA PANTALLA LCD PERMITEN REALIZAR FUNCIONES SIN NECESIDAD DE UNA PC EXTERNA:\n• MODO FOTOMETRÍA: LECTURA DIRECTA DE ABSORBANCIA O TRANSMITANCIA.\n• MODO CUANTITATIVO: CURVAS DE CALIBRACIÓN ESTÁNDAR (HASTA 8 PUNTOS).\n• CINÉTICA: SEGUIMIENTO DE REACCIONES QUÍMICAS EN TIEMPO REAL (ÚTIL PARA ENSAYOS ENZIMÁTICOS EN ECOTOXICIDAD).\n• VALIDACIÓN DEL SISTEMA: AUTODIAGNÓSTICO AL ENCENDER PARA VERIFICAR LA CALIBRACIÓN DE LA LONGITUD DE ONDA.\n5. DISEÑO Y CONECTIVIDAD\n• COMPARTIMENTO DE MUESTRAS: AMPLIO, CON CAPACIDAD PARA UN CAMBIADOR DE CELDAS MANUAL DE 4 POSICIONES (CUBETAS DE 10 MM ESTÁNDAR).\n• SALIDAS DE DATOS: PUERTO USB Y PUERTO PARALELO (RS-232) PARA CONEXIÓN A IMPRESORA O COMPUTADO"
  },
  "lifecycle": {
    "section": "concluido",
    "source_status": "ADJUDICADO",
    "moved_at": null
  },
  "buyer": {
    "agency": "UNIVERSIDAD DE GUANAJUATO",
    "acronym": "UGTO",
    "branch": "70 - GUANAJUATO",
    "buying_unit": "DEPARTAMENTO DE ADQUISICIONES Y CONTROL DE BIENES",
    "requesting_unit": "unidad requiriente data",
    "requesting_group": "DEPARTAMENTO DE ADQUISICIONES Y CONTROL DE BIENES",
    "entity": "UNIVERSIDAD DE GUANAJUATO",
    "slug": "ugto",
    "unit_slug": "departamento-de-adquisiciones-y-control-de-bienes-911043999"
  },
  "classification": {
    "procedure_type": "ADJUDICACIÓN DIRECTA",
    "contracting_type": "ADQUISICIONES",
    "publication_type": null,
    "character": "INTERNACIONAL ABIERTO",
    "fiscal_year": 2026,
    "law": "LEY DE ADQUISICIONES, ARRENDAMIENTOS Y SERVICIOS DEL SECTOR PÚBLICO",
    "legal_basis_id": "253",
    "exception_basis": "Art. 54 fr. VIII",
    "internal_control_number": "ADF-010-2026",
    "supply_source_number": null
  },
  "schedule": {
    "published_at": "2026-04-21T20:09:12.000Z",
    "clarification_meeting_at": null,
    "clarification_questions_deadline_at": null,
    "clarification_responses_deadline_at": null,
    "bid_opening_at": null,
    "award_at": null,
    "estimated_contract_at": "2026-04-30T06:00:00.000Z",
    "site_visit_at": null,
    "estimated_work_start_at": null
  },
  "estimated_value": {
    "minimum": null,
    "maximum": null,
    "currency": "MXN",
    "updated_at": null
  },
  "lots": [
    {
      "number": "1",
      "name": "PARTIDA SOLA",
      "description": "PARTIDA SOLA",
      "requirement_group_id": "1",
      "items": [
        {
          "number": "1",
          "cucop_code": "53101-0469",
          "specific_item_code": "53101",
          "cucop_description": "ESPECTRO-FOTOMETRO (INSTRUMENTO CIENTIFICO)",
          "description": "ESPECTROFOTOMETRO, MARCA UNICO, S-215OUV, UV/VIS\n1. ÓPTICA Y RANGO DE MEDICIÓN\n• RANGO DE LONGITUD DE ONDA: 200 NM A 1000 NM, LO QUE CUBRE TODAS LAS NECESIDADES PARA EL ANÁLISIS DE ANTIBIÓTICOS (COMO LAS PENICILINAS EN TU PROYECTO) Y ENSAYOS BIOLÓGICOS.\n• ANCHO DE BANDA ESPECTRAL: 4 NM. ES EL ESTÁNDAR IDEAL PARA ANÁLISIS CUANTITATIVOS, OFRECIENDO UN EQUILIBRIO ENTRE RESOLUCIÓN DE PICOS Y PASO DE LUZ.\n• SISTEMA ÓPTICO: HAZ ÚNICO (SINGLE BEAM) CON REJILLA DE DIFRACCIÓN DE 1200 LÍNEAS/MM.\n2. RENDIMIENTO Y PRECISIÓN\n• PRECISIÓN DE LONGITUD DE ONDA: $\\PM 1.0\\TEXT{ NM}$, ASEGURANDO QUE SIEMPRE MIDAS EN EL PICO MÁXIMO DE ABSORBANCIA DEL ANALITO.\n• REPETIBILIDAD DE LONGITUD DE ONDA: 0.5 NM.\n• LUZ DISPERSA (STRAY LIGHT): $\\LE 0.3\\% \\ T$ (MEDIDO A 220 NM Y 340 NM). ESTO ES VITAL PARA EVITAR ERRORES DE LECTURA EN CONCENTRACIONES ALTAS.\n• RANGO FOTOMÉTRICO:\nO ABSORBANCIA: -0.3 A 3.0 A.\nO TRANSMITANCIA: 0 A 200% T.\n3. FUENTES DE LUZ Y DETECCIÓN\n• LÁMPARAS: POSEE UN SISTEMA DUAL DE LÁMPARA DE DEUTERIO (D2) PARA EL RANGO UV Y LÁMPARA DE TUNGSTENO-HALÓGENO PARA EL RANGO VISIBLE.\n• DETECTOR: FOTODIODO DE SILICIO DE ALTA SENSIBILIDAD.\n• CAMBIO DE LÁMPARA: EL EQUIPO PERMITE CONFIGURAR EL PUNTO EXACTO DE INTERCAMBIO ENTRE LÁMPARAS (USUALMENTE A LOS 340 NM).\n4. FUNCIONES DE SOFTWARE INTEGRADAS\nEL PANEL DE CONTROL Y LA PANTALLA LCD PERMITEN REALIZAR FUNCIONES SIN NECESIDAD DE UNA PC EXTERNA:\n• MODO FOTOMETRÍA: LECTURA DIRECTA DE ABSORBANCIA O TRANSMITANCIA.\n• MODO CUANTITATIVO: CURVAS DE CALIBRACIÓN ESTÁNDAR (HASTA 8 PUNTOS).\n• CINÉTICA: SEGUIMIENTO DE REACCIONES QUÍMICAS EN TIEMPO REAL (ÚTIL PARA ENSAYOS ENZIMÁTICOS EN ECOTOXICIDAD).\n• VALIDACIÓN DEL SISTEMA: AUTODIAGNÓSTICO AL ENCENDER PARA VERIFICAR LA CALIBRACIÓN DE LA LONGITUD DE ONDA.\n5. DISEÑO Y CONECTIVIDAD\n• COMPARTIMENTO DE MUESTRAS: AMPLIO, CON CAPACIDAD PARA UN CAMBIADOR DE CELDAS MANUAL DE 4 POSICIONES (CUBETAS DE 10 MM ESTÁNDAR).\n• SALIDAS DE DATOS: PUERTO USB Y PUERTO PARALELO (RS-232) PARA CONEXIÓN A IMPRESORA O COMPUTADO",
          "requested_quantity": "1",
          "minimum_quantity": "1",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        }
      ]
    }
  ],
  "awards": [
    {
      "id": "C-2026-00030927",
      "internal_reference": "UG-FED-AD-028-2026",
      "title": "ADQUISICION DE ESPECTROFOTOMETRO",
      "status": "PUBLICADO",
      "contractor": {
        "name": "VIDRIERIA Y REACTIVOS SA DE CV",
        "normalized_name": "VIDRIERIA Y REACTIVOS",
        "rfc_type": null,
        "slug": "vidrieria-y-reactivos"
      },
      "contract_period": {
        "published_at": "2026-04-22T20:50:42.000Z",
        "starts_at": "2026-04-28T06:00:00.000Z",
        "ends_at": "2027-04-28T06:00:00.000Z"
      },
      "value": {
        "subtotal": "73648.33",
        "tax": "11783.73",
        "total": "85432.06",
        "maximum_subtotal": "0",
        "maximum_total": "0",
        "currency": "MXN"
      },
      "open_contract_type": null,
      "quantity": null,
      "exercised_quantity": null,
      "participants": [],
      "line_items": [
        {
          "number": "0",
          "cucop_code": "53101-0469",
          "description": "ESPECTROFOTOMETRO, MARCA UNICO, S-215OUV, UV/VIS\n1. ÓPTICA Y RANGO DE MEDICIÓN\n• RANGO DE LONGITUD DE ONDA: 200 NM A 1000 NM, LO QUE CUBRE TODAS LAS NECESIDADES PARA EL ANÁLISIS DE ANTIBIÓTICOS (COMO LAS PENICILINAS EN TU PROYECTO) Y ENSAYOS BIOLÓGICOS.\n• ANCHO DE BANDA ESPECTRAL: 4 NM. ES EL ESTÁNDAR IDEAL PARA ANÁLISIS CUANTITATIVOS, OFRECIENDO UN EQUILIBRIO ENTRE RESOLUCIÓN DE PICOS Y PASO DE LUZ.\n• SISTEMA ÓPTICO: HAZ ÚNICO (SINGLE BEAM) CON REJILLA DE DIFRACCIÓN DE 1200 LÍNEAS/MM.\n2. RENDIMIENTO Y PRECISIÓN\n• PRECISIÓN DE LONGITUD DE ONDA: $\\PM 1.0\\TEXT{ NM}$, ASEGURANDO QUE SIEMPRE MIDAS EN EL PICO MÁXIMO DE ABSORBANCIA DEL ANALITO.\n• REPETIBILIDAD DE LONGITUD DE ONDA: 0.5 NM.\n• LUZ DISPERSA (STRAY LIGHT): $\\LE 0.3\\% \\ T$ (MEDIDO A 220 NM Y 340 NM). ESTO ES VITAL PARA EVITAR ERRORES DE LECTURA EN CONCENTRACIONES ALTAS.\n• RANGO FOTOMÉTRICO:\nO ABSORBANCIA: -0.3 A 3.0 A.\nO TRANSMITANCIA: 0 A 200% T.\n3. FUENTES DE LUZ Y DETECCIÓN\n• LÁMPARAS: POSEE UN SISTEMA DUAL DE LÁMPARA DE DEUTERIO (D2) PARA EL RANGO UV Y LÁMPARA DE TUNGSTENO-HALÓGENO PARA EL RANGO VISIBLE.\n• DETECTOR: FOTODIODO DE SILICIO DE ALTA SENSIBILIDAD.\n• CAMBIO DE LÁMPARA: EL EQUIPO PERMITE CONFIGURAR EL PUNTO EXACTO DE INTERCAMBIO ENTRE LÁMPARAS (USUALMENTE A LOS 340 NM).\n4. FUNCIONES DE SOFTWARE INTEGRADAS\nEL PANEL DE CONTROL Y LA PANTALLA LCD PERMITEN REALIZAR FUNCIONES SIN NECESIDAD DE UNA PC EXTERNA:\n• MODO FOTOMETRÍA: LECTURA DIRECTA DE ABSORBANCIA O TRANSMITANCIA.\n• MODO CUANTITATIVO: CURVAS DE CALIBRACIÓN ESTÁNDAR (HASTA 8 PUNTOS).\n• CINÉTICA: SEGUIMIENTO DE REACCIONES QUÍMICAS EN TIEMPO REAL (ÚTIL PARA ENSAYOS ENZIMÁTICOS EN ECOTOXICIDAD).\n• VALIDACIÓN DEL SISTEMA: AUTODIAGNÓSTICO AL ENCENDER PARA VERIFICAR LA CALIBRACIÓN DE LA LONGITUD DE ONDA.\n5. DISEÑO Y CONECTIVIDAD\n• COMPARTIMENTO DE MUESTRAS: AMPLIO, CON CAPACIDAD PARA UN CAMBIADOR DE CELDAS MANUAL DE 4 POSICIONES (CUBETAS DE 10 MM ESTÁNDAR).\n• SALIDAS DE DATOS: PUERTO USB Y PUERTO PARALELO (RS-232) PARA CONEXIÓN A IMPRESORA O COMPUTADO",
          "unit": "PIEZA",
          "requested_quantity": "1",
          "awarded_quantity": null,
          "unit_price": "73648.33",
          "subtotal": "73648.33",
          "tax": "11783.73",
          "other_taxes": null,
          "total": "85432.06"
        }
      ]
    }
  ],
  "documents": [
    {
      "id": null,
      "annex_number": 1,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "ANEXO TECNICO.pdf",
      "availability": "available",
      "size_bytes": "112617",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2026-04-23T04:17:03.543Z",
      "updated_at": "2026-04-23T04:17:08.223Z"
    },
    {
      "id": null,
      "annex_number": 1,
      "document_type": null,
      "description": "JUSTIFICACIÓN DE EXCEPCIÓN",
      "filename": "ADF010 DICTA.pdf",
      "availability": "available",
      "size_bytes": "2870046",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2026-04-23T04:17:06.077Z",
      "updated_at": "2026-04-23T04:17:08.225Z"
    },
    {
      "id": null,
      "annex_number": 6,
      "document_type": null,
      "description": "OFICIO DE NOTIFICACIÓN DE ADJUDICACIÓN",
      "filename": "ACTA.pdf",
      "availability": "available",
      "size_bytes": "1127186",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2026-04-23T04:17:08.009Z",
      "updated_at": "2026-04-23T04:17:08.227Z"
    }
  ],
  "alternates": [],
  "similar": [
    {
      "numero_procedimiento": "aa-38-9zu-0389zu001-n-147-2024",
      "nombre_procedimiento": "ESPECTROFOTOMETRO UV-VISIBLE JENWAY 7205 DE 90 A 240 VCA. ANCHO 1 DE BANDA  ESPE",
      "dependencia": "CIDESI",
      "siglas": "CIDESI",
      "score": 0.15616011619567272
    },
    {
      "numero_procedimiento": "aa-70-q94-911043999-i-38-2026",
      "nombre_procedimiento": "ESPECTROFOTÓMETRO UV/VIS",
      "dependencia": "UNIVERSIDAD DE GUANAJUATO",
      "siglas": "UGTO",
      "score": 0.1573566700603548
    },
    {
      "numero_procedimiento": "aa-80-v26-921069958-n-25-2024",
      "nombre_procedimiento": "ADQUISICIÓN DE UN ESPECTROFOTÓMETRO",
      "dependencia": "BUAP",
      "siglas": "BUAP",
      "score": 0.17167106181304392
    },
    {
      "numero_procedimiento": "aa-85-w83-926014991-n-128-2024",
      "nombre_procedimiento": "ADQUISICIÓN DE EQUIPO DE LABORATORIO",
      "dependencia": "INSTITUTO TECNOLÓGICO DE SONORA",
      "siglas": "ITSON",
      "score": 0.17759924068455313
    },
    {
      "numero_procedimiento": "aa-08-izc-008izc999-n-238-2024",
      "nombre_procedimiento": "ADQUISICIÓN DE  ESPECTROFOTOMETRO UV-VIS GENESYS 50 190-1100NM THERMO SCIENTIFIC",
      "dependencia": "COLPOS",
      "siglas": "COLPOS",
      "score": 0.2023799298775224
    },
    {
      "numero_procedimiento": "aa-08-izc-008izc999-n-87-2023",
      "nombre_procedimiento": "ADQUISICON DE ESPECTOFOTOMETRO P/MICROPLACAS 96-384 POZOS PARA EL PROYECTO PM23",
      "dependencia": "COLEGIO DE POSTGRADUADOS",
      "siglas": "COLPOS",
      "score": 0.23325805465828908
    }
  ]
}