  "html_url": "https://licitia.com.mx/adjudicacion/aa-86-x74-927006955-n-13-2023",
  "canonical": "https://licitia.com.mx/adjudicacion/aa-86-x74-927006955-n-13-2023",
  "id": "43393e118feb4e18882f93894cc1c92e",
  "procedure_number": "AA-86-X74-927006955-N-13-2023",
  "file_number": "E-2023-00061778",
  "title": "CONTRATACIÓN DEL SERVICIO DE INSTALACIÓN, REPARACIÓN Y MANTENIMIENTO DE EQUIPO",
  "description": {
    "short": "No existen bienes alternativos o sustitutos, Único Oferente, Derechos exclusivos (patentes, licencias, derechos de autor u otros derechos exclusivos), o por obras de arte.",
    "detailed": "35401.- CONTRATACIÓN DEL SERVICIO DE INSTALACIÓN, REPARACIÓN Y MANTENIMIENTO DE EQUIPO E INSTRUMENTAL MEDICO Y DE LABORATORIO"
  },
  "lifecycle": {
    "section": "concluido",
    "source_status": "ADJUDICADO",
    "moved_at": null
  },
  "buyer": {
    "agency": "SSA-HRAEDJGC",
    "acronym": "SSA-HRAEDJGC",
    "branch": "86 - TABASCO",
    "buying_unit": "HOSPITAL REGIONAL DE ALTA ESPECIALIDAD DR. JUAN GRAHAM CASASUS, SUBDIRECCIÓN DE ADMON.",
    "requesting_unit": "unidad requiriente data",
    "requesting_group": "HOSPITAL REGIONAL DE ALTA ESPECIALIDAD DR. JUAN GRAHAM CASASUS, SUBDIRECCIÓN DE ADMON.",
    "entity": "SERVICIOS DE SALUD DEL ESTADO DE TABASCO",
    "slug": "ssa-hraedjgc",
    "unit_slug": "hospital-regional-de-alta-especialidad-dr-juan-graham-casasus-subdireccion-de-admon--927006955"
  },
  "classification": {
    "procedure_type": "ADJUDICACIÓN DIRECTA",
    "contracting_type": "SERVICIOS",
    "publication_type": null,
    "character": "NACIONAL",
    "fiscal_year": 2023,
    "law": "LEY DE ADQUISICIONES, ARRENDAMIENTOS Y SERVICIOS DEL SECTOR PÚBLICO",
    "legal_basis_id": "22",
    "exception_basis": "Art. 41 fr. I",
    "internal_control_number": "AA-E13-2023",
    "supply_source_number": null
  },
  "schedule": {
    "published_at": "2023-09-21T02:48:22.000Z",
    "clarification_meeting_at": null,
    "clarification_questions_deadline_at": null,
    "clarification_responses_deadline_at": null,
    "bid_opening_at": null,
    "award_at": null,
    "estimated_contract_at": "2023-07-11T06:00:00.000Z",
    "site_visit_at": null,
    "estimated_work_start_at": null
  },
  "estimated_value": {
    "minimum": null,
    "maximum": null,
    "currency": "MXN",
    "updated_at": null
  },
  "lots": [
    {
      "number": "1",
      "name": "PARTIDA SOLA",
      "description": "PARTIDA SOLA",
      "requirement_group_id": "1",
      "items": [
        {
          "number": "1",
          "cucop_code": "35401-0001",
          "specific_item_code": "35401",
          "cucop_description": "SERVICIOS DE INSTALACION DE EQUIPO E INSTRUMENTAL MEDICO",
          "description": "SERVICIO DE MANTENIMIENTO PREVENTIVO A EQUIPO MÉDICO MAQUINAS DE ANESTESIA MODELO PRIMUS IE MARCA DRAGER MODELO PRIMUS IE",
          "requested_quantity": "4",
          "minimum_quantity": "4",
          "maximum_quantity": null,
          "unit": "SERVICIO",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "2",
          "cucop_code": "35401-0001",
          "specific_item_code": "35401",
          "cucop_description": "SERVICIOS DE INSTALACION DE EQUIPO E INSTRUMENTAL MEDICO",
          "description": "SERVICIO DE MANTENIMIENTO PREVENTIVO A EQUIPO MÉDICO MAQUINAS DE ANESTESIA MODELO PERSEUS A500 MARCA DRAGER NUMERO DE SERIE E INVENTARIO: ASLL-0065, EHJG/011047; ASLL-0066, EHJG/01048  EL CUAL INCLUYE:   -REVISION DEL ASPECTO GENERAL.  - CHEQUEO Y REVISIÓN DE JUNTAS Y FILTROS.  - PRUEBA DE SEGURIDAD ELÉCTRICA, CORRIENTE DE FUGA, TOMA DE TIERRA.  - CHEQUEO DE LA CONEXION DEL VAPORIZADOR.  - CHEQUEO DEL DOSIFICADOR DE GASES FRESCOS. PRUEBA DE FUGAS Y REVISIÓN CON PRUEBA DE LA VÁLVULA DE PROPORCIONALIDAD.  - PRUEBA DE PARÁMETROS DE PRESIONES, FLUJOS Y VOLÚMENES, FIO2 Y TEMPERATURAS.  - PRUEBA DE ANALIZADOR DE GASES.  - PRUEBA FUNCIONAL DEL VENTILADOR Y DEL SISTEMA DE VENTILACION CON CALEFACTOR PARA SU USO EN PACIENTE.  - INFORMAR AL USUARIO DEL RESULTADO DE LA PRUEBA",
          "requested_quantity": "2",
          "minimum_quantity": "2",
          "maximum_quantity": null,
          "unit": "SERVICIO",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "3",
          "cucop_code": "35401-0001",
          "specific_item_code": "35401",
          "cucop_description": "SERVICIOS DE INSTALACION DE EQUIPO E INSTRUMENTAL MEDICO",
          "description": "MANTENIMIENTO PREVENTIVO Y CORRECTIVO DE EQUIPO MEDICO A MONITOR DE SIGNOS VITALES\nMODELO KAPPA MARCA DRAGER, CON LOS SIGUIENTES DATOS:\n1.-  SERIE 5495569354, NUMERO DE INVENTARIO: EHJG/011047-3\n2.-  SERIE 5495567953, NUMERO DE INVENTARIO: SHJG/0100688-1\n\n EL CUAL INCLUYE:\n- PRUEBA FUNCIONAL DEL EQUIPO, CONFIGURACIONES.\n- REVISIÓN GENERAL DE LOS EQUIPOS Y SUS PARTES, QUE PERMITAN ESTABLECER LA NECESIDAD DE AJUSTE, REPARACIÓN Y/O CAMBIO DE PIEZAS, QUE SUFRAN DESGASTE POR EL USO NORMAL.\n- VERIFICAR LA FUNCIÓN DE LOS CONTROLES DE BRILLO Y CONTRASTE, INTERNOS O EXTERNOS\n- VERIFICAR QUE LOS VALORES ENTREGADOS POR EL EQUIPO SEAN LOS MISMOS QUE APARECEN EN LOS MEDIDORES.\n- PRUEBA Y MEDIDA DE SEGURIDAD DE CORRIENTE DE FUGAS ELÉCTRICAS DEL MONITOR Y TODOS LOS ELEMENTOS ELÉCTRICOS ASOCIADOS A DICHO EQUIPO.\n- LIMPIEZA EXTERNA E INTERNA DE PARTES INACCESIBLES AL CLIENTE.\n- INFORMAR AL USUARIO DEL RESULTADO DE LA PRUEBA.",
          "requested_quantity": "2",
          "minimum_quantity": "2",
          "maximum_quantity": null,
          "unit": "SERVICIO",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "4",
          "cucop_code": "35401-0001",
          "specific_item_code": "35401",
          "cucop_description": "SERVICIOS DE INSTALACION DE EQUIPO E INSTRUMENTAL MEDICO",
          "description": "SERVICIO DE MANTENIMIENTO PREVENTIVO A EQUIPO MÉDICO VAPORIZADOR MODELO VAPOR 2000 MARCA DRAGER NUMERO DE SERIE E INVENTARIO: ASHM-1775, SHJG/006288-3; ASHM-1238, SHJG/006287-4; ASHM-1773, SHJG/006286-4; ASHM-1237, SHJG/006286-3; ASHM-1240, SHJG/006288-4; ASLL-0014, EHJG/011047-6; ASHM-0924, SHJG/006287-3; ASHM-0964, SHJG/006289-3; ASHM-1239, SHJG/006289-4; ASLL-0459, EHJG/011048-6.  EL CUAL INCLUYE:  -REVISION DEL ESTADO GENERAL DEL EQUIPO  -PRUEBA DE SEGURIDAD.  -COMPROBACION Y MEDIDA DE PARAMETROS RESPIRATORIOS  -PRUEBA DE COMPONENTES NEUMATICOS, ELETRONICOS, ALARMAS Y PUNTOS DE SEGURIDAD  -PRUEBAS DESDE MODO DE SERVICIO DRAGER SERVICE",
          "requested_quantity": "10",
          "minimum_quantity": "10",
          "maximum_quantity": null,
          "unit": "SERVICIO",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "5",
          "cucop_code": "35401-0001",
          "specific_item_code": "35401",
          "cucop_description": "SERVICIOS DE INSTALACION DE EQUIPO E INSTRUMENTAL MEDICO",
          "description": "MANTENIMIENTO PREVENTIVO Y CORRECTIVO A EQUIPO MÉDICO VENTILADOR DE CUIDADOS INTENSIVOS MODELO EVITA XL MCA DRAGER\n CON LOS SIGUIENTES DATOS:\n1.- SERIE ASDF-0050,  INVENTARIO: EHJG/011404\n2.- SERIE ASDF-0051,  INVENTARIO: EHJG/011405\n3.- SERIE ASDF-0052,  INVENTARIO: EHJG/011406\n4.- SERIE ASCL-0327,  INVENTARIO: EHJG/010612\n5.- SERIE ASCL-0328,  INVENTARIO: EHJG/010604\n6.- SERIE ASCL-0329,  INVENTARIO: EHJG/010608\n7.- SERIE ASCL-0330,  INVENTARIO: EHJG/010605\n8.- SERIE ASCL-0331,  INVENTARIO: EHJG/010607\n9.- SERIE ASCL-0332,  INVENTARIO: EHJG/010610\n10.- SERIE ASCL-0334, INVENTARIO: EHJG/010609\n11.- SERIE ASCL-0335, INVENTARIO: EHJG/010611\n12.- SERIE ASCL-0336, INVENTARIO: EHJG/010613\n13.- SERIE ASCL-0337, INVENTARIO: EHJG/010606\n14.- SERIE ASDF-0053, INVENTARIO: EHRM/001383\n15.- SERIE ASDF-0054, INVENTARIO: EHRM/001380\n16.- SERIE ASDF-0055, INVENTARIO: EHRM/001385\n17.- SERIE ASDF-0056, INVENTARIO: EHRM/001386\n18.- SERIE ASDF-0057, INVENTARIO: EHRM/001387\n EL CUAL INCLUYE:\n-REVISIÓN DE ASPECTO GENERAL, ASI COMO DE LAS HORAS DE FUNCIONAMIENTO,\n-COMPROBACIÓN DE LA FUENTE DE ALIMENTACIÓN.\n-REVISIÓN DE LAS VÁLVULAS DE SEGURIDAD\n-CONTROL DE TENSIÓN DE ALIMENTACIÓN\n-REVISIÓN DEL CONTROL DE FUNCIONES NEUMÁTICAS, PRUEBA DE SEGURIDAD NEUMÁTICA, VÁLVULAS DE EMERGENCIA, COMPROBACIÓN Y VERIFICACIÓN DE SENSORES DE O2, FLUJO Y PRESIONES.\n-COMPROBACIÓN DE PARÁMETROS Y MEDIDA DE RESPIRATORIOS EN LOS DISTINTOS MODOS VENTILATORIOS, COMPROBACIÓN DE ALARMAS.\n-LIMPIEZA INTERNA Y EXTERNA.\n- INFORMAR AL USUARIO DEL RESULTADO DE LA PRUEBA",
          "requested_quantity": "18",
          "minimum_quantity": "18",
          "maximum_quantity": null,
          "unit": "SERVICIO",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "6",
          "cucop_code": "35401-0001",
          "specific_item_code": "35401",
          "cucop_description": "SERVICIOS DE INSTALACION DE EQUIPO E INSTRUMENTAL MEDICO",
          "description": "MANTENIMIENTO PREVENTIVO Y CORRECTIVO A EQUIPO MÉDICO VENTILADOR DE CUIDADOS INTENSIVOS MODELO EVITA V300 MCA DRAGER\n CON LOS SIGUIENTES DATOS:\nSERIE ASMM-0252, NUMERO DE INVENTARIO \nSERIE ASMM-0225, NUMERO DE INVENTARIO\n EL CUAL INCLUYE:\n-REVISIÓN DE ASPECTO GENERAL, ASI COMO DE LAS HORAS DE FUNCIONAMIENTO,\n-COMPROBACIÓN DE LA FUENTE DE ALIMENTACIÓN.\n-REVISIÓN DE LAS VÁLVULAS DE SEGURIDAD\n-CONTROL DE TENSIÓN DE ALIMENTACIÓN\n-REVISIÓN DEL CONTROL DE FUNCIONES NEUMÁTICAS, PRUEBA DE SEGURIDAD NEUMÁTICA, VÁLVULAS DE EMERGENCIA, COMPROBACIÓN Y VERIFICACIÓN DE SENSORES DE O2, FLUJO Y PRESIONES.\n-COMPROBACIÓN DE PARÁMETROS Y MEDIDA DE RESPIRATORIOS EN LOS DISTINTOS MODOS VENTILATORIOS, COMPROBACIÓN DE ALARMAS.\n-LIMPIEZA INTERNA Y EXTERNA.\n- INFORMAR AL USUARIO DEL RESULTADO DE LA PRUEBA.",
          "requested_quantity": "2",
          "minimum_quantity": "2",
          "maximum_quantity": null,
          "unit": "SERVICIO",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "7",
          "cucop_code": "35401-0001",
          "specific_item_code": "35401",
          "cucop_description": "SERVICIOS DE INSTALACION DE EQUIPO E INSTRUMENTAL MEDICO",
          "description": "MANTENIMIENTO PREVENTIVO A EQUIPOS MONITORES DE SIGNOS VITALES\nMODELO DELTA XL, MARCA DRAGER, CON LOS SIGUIENTES DATOS:\n\n1.-  SERIE 6007806574, NUMERO DE INVENTARIO: SHJG/1006289-3\n2.-  SERIE 6007825767, NUMERO DE INVENTARIO: SHJG/1006286-6\n3.-  SERIE 6007823867, NUMERO DE INVENTARIO: SHJG/1006287-3\n4.-  SERIE 6007790768, NUMERO DE INVENTARIO: SHJG/1006288-3\n\n EL CUAL INCLUYE:\n- PRUEBA FUNCIONAL DEL EQUIPO, CONFIGURACIONES.\n- REVISIÓN GENERAL DE LOS EQUIPOS Y SUS PARTES, QUE PERMITAN ESTABLECER LA NECESIDAD DE AJUSTE, REPARACIÓN Y/O CAMBIO DE PIEZAS, QUE SUFRAN DESGASTE POR EL USO NORMAL.\n- VERIFICAR LA FUNCIÓN DE LOS CONTROLES DE BRILLO Y CONTRASTE, INTERNOS O EXTERNOS\n- VERIFICAR QUE LOS VALORES ENTREGADOS POR EL EQUIPO SEAN LOS MISMOS QUE APARECEN EN LOS MEDIDORES.\n- PRUEBA Y MEDIDA DE SEGURIDAD DE CORRIENTE DE FUGAS ELÉCTRICAS DEL MONITOR Y TODOS LOS ELEMENTOS ELÉCTRICOS ASOCIADOS A DICHO EQUIPO.\n- LIMPIEZA EXTERNA E INTERNA DE PARTES INACCESIBLES AL CLIENTE.\n- INFORMAR AL USUARIO DEL RESULTADO DE LA PRUEBA.",
          "requested_quantity": "4",
          "minimum_quantity": "4",
          "maximum_quantity": null,
          "unit": "SERVICIO",
          "minimum_amount": null,
          "maximum_amount": null
        }
      ]
    }
  ],
  "awards": [
    {
      "id": "C-2023-00110961",
      "internal_reference": "CP08170101-41/2023",
      "title": "CONTRATACIÓN DEL SERVICIO DE INSTALACIÓN, REPARACIÓN Y MANTENIMIENTO DE EQUIPO",
      "status": "PUBLICADO",
      "contractor": {
        "name": "MEDICAL ADVANCED SUPPLIES SA DE CV",
        "normalized_name": "MEDICAL ADVANCED SUPPLIES",
        "rfc_type": null,
        "slug": "medical-advanced-supplies"
      },
      "contract_period": {
        "published_at": "2023-09-21T02:48:22.000Z",
        "starts_at": "2023-07-11T06:00:00.000Z",
        "ends_at": "2023-08-11T06:00:00.000Z"
      },
      "value": {
        "subtotal": "5396760",
        "tax": "863481.6",
        "total": "6260241.6",
        "maximum_subtotal": "0",
        "maximum_total": "0",
        "currency": "MXN"
      },
      "open_contract_type": null,
      "quantity": null,
      "exercised_quantity": null,
      "participants": [],
      "line_items": [
        {
          "number": "0",
          "cucop_code": "35401-0001",
          "description": "SERVICIO DE MANTENIMIENTO PREVENTIVO A EQUIPO MÉDICO MAQUINAS DE ANESTESIA MODELO PRIMUS IE MARCA DRAGER MODELO PRIMUS IE",
          "unit": "SERVICIO",
          "requested_quantity": "4",
          "awarded_quantity": null,
          "unit_price": "217800",
          "subtotal": "871200",
          "tax": "139392",
          "other_taxes": null,
          "total": "1010592"
        },
        {
          "number": "0",
          "cucop_code": "35401-0001",
          "description": "SERVICIO DE MANTENIMIENTO PREVENTIVO A EQUIPO MÉDICO MAQUINAS DE ANESTESIA MODELO PERSEUS A500 MARCA DRAGER NUMERO DE SERIE E INVENTARIO: ASLL-0065, EHJG/011047; ASLL-0066, EHJG/01048  EL CUAL INCLUYE:   -REVISION DEL ASPECTO GENERAL.  - CHEQUEO Y REVISIÓN DE JUNTAS Y FILTROS.  - PRUEBA DE SEGURIDAD ELÉCTRICA, CORRIENTE DE FUGA, TOMA DE TIERRA.  - CHEQUEO DE LA CONEXION DEL VAPORIZADOR.  - CHEQUEO DEL DOSIFICADOR DE GASES FRESCOS. PRUEBA DE FUGAS Y REVISIÓN CON PRUEBA DE LA VÁLVULA DE PROPORCIONALIDAD.  - PRUEBA DE PARÁMETROS DE PRESIONES, FLUJOS Y VOLÚMENES, FIO2 Y TEMPERATURAS.  - PRUEBA DE ANALIZADOR DE GASES.  - PRUEBA FUNCIONAL DEL VENTILADOR Y DEL SISTEMA DE VENTILACION CON CALEFACTOR PARA SU USO EN PACIENTE.  - INFORMAR AL USUARIO DEL RESULTADO DE LA PRUEBA",
          "unit": "SERVICIO",
          "requested_quantity": "2",
          "awarded_quantity": null,
          "unit_price": "324527.5",
          "subtotal": "649055",
          "tax": "103848.8",
          "other_taxes": null,
          "total": "752903.8"
        },
        {
          "number": "0",
          "cucop_code": "35401-0001",
          "description": "MANTENIMIENTO PREVENTIVO Y CORRECTIVO DE EQUIPO MEDICO A MONITOR DE SIGNOS VITALES\nMODELO KAPPA MARCA DRAGER, CON LOS SIGUIENTES DATOS:\n1.-  SERIE 5495569354, NUMERO DE INVENTARIO: EHJG/011047-3\n2.-  SERIE 5495567953, NUMERO DE INVENTARIO: SHJG/0100688-1\n\n EL CUAL INCLUYE:\n- PRUEBA FUNCIONAL DEL EQUIPO, CONFIGURACIONES.\n- REVISIÓN GENERAL DE LOS EQUIPOS Y SUS PARTES, QUE PERMITAN ESTABLECER LA NECESIDAD DE AJUSTE, REPARACIÓN Y/O CAMBIO DE PIEZAS, QUE SUFRAN DESGASTE POR EL USO NORMAL.\n- VERIFICAR LA FUNCIÓN DE LOS CONTROLES DE BRILLO Y CONTRASTE, INTERNOS O EXTERNOS\n- VERIFICAR QUE LOS VALORES ENTREGADOS POR EL EQUIPO SEAN LOS MISMOS QUE APARECEN EN LOS MEDIDORES.\n- PRUEBA Y MEDIDA DE SEGURIDAD DE CORRIENTE DE FUGAS ELÉCTRICAS DEL MONITOR Y TODOS LOS ELEMENTOS ELÉCTRICOS ASOCIADOS A DICHO EQUIPO.\n- LIMPIEZA EXTERNA E INTERNA DE PARTES INACCESIBLES AL CLIENTE.\n- INFORMAR AL USUARIO DEL RESULTADO DE LA PRUEBA.",
          "unit": "SERVICIO",
          "requested_quantity": "2",
          "awarded_quantity": null,
          "unit_price": "89402.5",
          "subtotal": "178805",
          "tax": "28608.8",
          "other_taxes": null,
          "total": "207413.8"
        },
        {
          "number": "0",
          "cucop_code": "35401-0001",
          "description": "SERVICIO DE MANTENIMIENTO PREVENTIVO A EQUIPO MÉDICO VAPORIZADOR MODELO VAPOR 2000 MARCA DRAGER NUMERO DE SERIE E INVENTARIO: ASHM-1775, SHJG/006288-3; ASHM-1238, SHJG/006287-4; ASHM-1773, SHJG/006286-4; ASHM-1237, SHJG/006286-3; ASHM-1240, SHJG/006288-4; ASLL-0014, EHJG/011047-6; ASHM-0924, SHJG/006287-3; ASHM-0964, SHJG/006289-3; ASHM-1239, SHJG/006289-4; ASLL-0459, EHJG/011048-6.  EL CUAL INCLUYE:  -REVISION DEL ESTADO GENERAL DEL EQUIPO  -PRUEBA DE SEGURIDAD.  -COMPROBACION Y MEDIDA DE PARAMETROS RESPIRATORIOS  -PRUEBA DE COMPONENTES NEUMATICOS, ELETRONICOS, ALARMAS Y PUNTOS DE SEGURIDAD  -PRUEBAS DESDE MODO DE SERVICIO DRAGER SERVICE",
          "unit": "SERVICIO",
          "requested_quantity": "10",
          "awarded_quantity": null,
          "unit_price": "22605",
          "subtotal": "226050",
          "tax": "36168",
          "other_taxes": null,
          "total": "262218"
        },
        {
          "number": "0",
          "cucop_code": "35401-0001",
          "description": "MANTENIMIENTO PREVENTIVO Y CORRECTIVO A EQUIPO MÉDICO VENTILADOR DE CUIDADOS INTENSIVOS MODELO EVITA XL MCA DRAGER\n CON LOS SIGUIENTES DATOS:\n1.- SERIE ASDF-0050,  INVENTARIO: EHJG/011404\n2.- SERIE ASDF-0051,  INVENTARIO: EHJG/011405\n3.- SERIE ASDF-0052,  INVENTARIO: EHJG/011406\n4.- SERIE ASCL-0327,  INVENTARIO: EHJG/010612\n5.- SERIE ASCL-0328,  INVENTARIO: EHJG/010604\n6.- SERIE ASCL-0329,  INVENTARIO: EHJG/010608\n7.- SERIE ASCL-0330,  INVENTARIO: EHJG/010605\n8.- SERIE ASCL-0331,  INVENTARIO: EHJG/010607\n9.- SERIE ASCL-0332,  INVENTARIO: EHJG/010610\n10.- SERIE ASCL-0334, INVENTARIO: EHJG/010609\n11.- SERIE ASCL-0335, INVENTARIO: EHJG/010611\n12.- SERIE ASCL-0336, INVENTARIO: EHJG/010613\n13.- SERIE ASCL-0337, INVENTARIO: EHJG/010606\n14.- SERIE ASDF-0053, INVENTARIO: EHRM/001383\n15.- SERIE ASDF-0054, INVENTARIO: EHRM/001380\n16.- SERIE ASDF-0055, INVENTARIO: EHRM/001385\n17.- SERIE ASDF-0056, INVENTARIO: EHRM/001386\n18.- SERIE ASDF-0057, INVENTARIO: EHRM/001387\n EL CUAL INCLUYE:\n-REVISIÓN DE ASPECTO GENERAL, ASI COMO DE LAS HORAS DE FUNCIONAMIENTO,\n-COMPROBACIÓN DE LA FUENTE DE ALIMENTACIÓN.\n-REVISIÓN DE LAS VÁLVULAS DE SEGURIDAD\n-CONTROL DE TENSIÓN DE ALIMENTACIÓN\n-REVISIÓN DEL CONTROL DE FUNCIONES NEUMÁTICAS, PRUEBA DE SEGURIDAD NEUMÁTICA, VÁLVULAS DE EMERGENCIA, COMPROBACIÓN Y VERIFICACIÓN DE SENSORES DE O2, FLUJO Y PRESIONES.\n-COMPROBACIÓN DE PARÁMETROS Y MEDIDA DE RESPIRATORIOS EN LOS DISTINTOS MODOS VENTILATORIOS, COMPROBACIÓN DE ALARMAS.\n-LIMPIEZA INTERNA Y EXTERNA.\n- INFORMAR AL USUARIO DEL RESULTADO DE LA PRUEBA",
          "unit": "SERVICIO",
          "requested_quantity": "18",
          "awarded_quantity": null,
          "unit_price": "155171.41",
          "subtotal": "2793085.38",
          "tax": "446893.66",
          "other_taxes": null,
          "total": "3239979.04"
        },
        {
          "number": "0",
          "cucop_code": "35401-0001",
          "description": "MANTENIMIENTO PREVENTIVO Y CORRECTIVO A EQUIPO MÉDICO VENTILADOR DE CUIDADOS INTENSIVOS MODELO EVITA V300 MCA DRAGER\n CON LOS SIGUIENTES DATOS:\nSERIE ASMM-0252, NUMERO DE INVENTARIO \nSERIE ASMM-0225, NUMERO DE INVENTARIO\n EL CUAL INCLUYE:\n-REVISIÓN DE ASPECTO GENERAL, ASI COMO DE LAS HORAS DE FUNCIONAMIENTO,\n-COMPROBACIÓN DE LA FUENTE DE ALIMENTACIÓN.\n-REVISIÓN DE LAS VÁLVULAS DE SEGURIDAD\n-CONTROL DE TENSIÓN DE ALIMENTACIÓN\n-REVISIÓN DEL CONTROL DE FUNCIONES NEUMÁTICAS, PRUEBA DE SEGURIDAD NEUMÁTICA, VÁLVULAS DE EMERGENCIA, COMPROBACIÓN Y VERIFICACIÓN DE SENSORES DE O2, FLUJO Y PRESIONES.\n-COMPROBACIÓN DE PARÁMETROS Y MEDIDA DE RESPIRATORIOS EN LOS DISTINTOS MODOS VENTILATORIOS, COMPROBACIÓN DE ALARMAS.\n-LIMPIEZA INTERNA Y EXTERNA.\n- INFORMAR AL USUARIO DEL RESULTADO DE LA PRUEBA.",
          "unit": "SERVICIO",
          "requested_quantity": "2",
          "awarded_quantity": null,
          "unit_price": "160477.31",
          "subtotal": "320954.62",
          "tax": "51352.74",
          "other_taxes": null,
          "total": "372307.36"
        },
        {
          "number": "0",
          "cucop_code": "35401-0001",
          "description": "MANTENIMIENTO PREVENTIVO A EQUIPOS MONITORES DE SIGNOS VITALES\nMODELO DELTA XL, MARCA DRAGER, CON LOS SIGUIENTES DATOS:\n\n1.-  SERIE 6007806574, NUMERO DE INVENTARIO: SHJG/1006289-3\n2.-  SERIE 6007825767, NUMERO DE INVENTARIO: SHJG/1006286-6\n3.-  SERIE 6007823867, NUMERO DE INVENTARIO: SHJG/1006287-3\n4.-  SERIE 6007790768, NUMERO DE INVENTARIO: SHJG/1006288-3\n\n EL CUAL INCLUYE:\n- PRUEBA FUNCIONAL DEL EQUIPO, CONFIGURACIONES.\n- REVISIÓN GENERAL DE LOS EQUIPOS Y SUS PARTES, QUE PERMITAN ESTABLECER LA NECESIDAD DE AJUSTE, REPARACIÓN Y/O CAMBIO DE PIEZAS, QUE SUFRAN DESGASTE POR EL USO NORMAL.\n- VERIFICAR LA FUNCIÓN DE LOS CONTROLES DE BRILLO Y CONTRASTE, INTERNOS O EXTERNOS\n- VERIFICAR QUE LOS VALORES ENTREGADOS POR EL EQUIPO SEAN LOS MISMOS QUE APARECEN EN LOS MEDIDORES.\n- PRUEBA Y MEDIDA DE SEGURIDAD DE CORRIENTE DE FUGAS ELÉCTRICAS DEL MONITOR Y TODOS LOS ELEMENTOS ELÉCTRICOS ASOCIADOS A DICHO EQUIPO.\n- LIMPIEZA EXTERNA E INTERNA DE PARTES INACCESIBLES AL CLIENTE.\n- INFORMAR AL USUARIO DEL RESULTADO DE LA PRUEBA.",
          "unit": "SERVICIO",
          "requested_quantity": "4",
          "awarded_quantity": null,
          "unit_price": "89402.5",
          "subtotal": "357610",
          "tax": "57217.6",
          "other_taxes": null,
          "total": "414827.6"
        }
      ]
    }
  ],
  "documents": [
    {
      "id": null,
      "annex_number": 1,
      "document_type": null,
      "description": "JUSTIFICACIÓN DE EXCEPCIÓN",
      "filename": "DICTAMEN DE EXCEPCION.pdf",
      "availability": "available",
      "size_bytes": "5202710",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-12T16:18:38.373Z",
      "updated_at": "2025-12-12T16:18:38.375Z"
    },
    {
      "id": null,
      "annex_number": 1,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "ANEXO TECNICO.pdf",
      "availability": "available",
      "size_bytes": "998149",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-12T16:18:42.350Z",
      "updated_at": "2025-12-12T16:18:42.351Z"
    },
    {
      "id": null,
      "annex_number": 4,
      "document_type": null,
      "description": "OFICIO DE ADJUDICACIÓN",
      "filename": "N-13 contrato 41 medical advanced.pdf",
      "availability": "available",
      "size_bytes": "6408241",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-12T16:18:49.906Z",
      "updated_at": "2025-12-12T16:18:49.907Z"
    }
  ],
  "alternates": [],
  "similar": [
    {
      "numero_procedimiento": "aa-12-nbs-012nbs001-n-34-2023",
      "nombre_procedimiento": "SERVICIO DE MANTENIMIENTO PREVENTIVO Y CORRECTIVO GRÄGER",
      "dependencia": "SERVICIOS DE SALUD DEL INSTITUTO MEXICANO DEL SEGURO SOCIAL PARA EL BIENESTAR (IMSS-BIENESTAR)",
      "siglas": "IMSS-BIENESTAR",
      "score": 0.12799975347507464
    },
    {
      "numero_procedimiento": "aa-47-ayo-047ayo940-n-36-2024",
      "nombre_procedimiento": "SERVICIO DE MANTENIMIENTO PREVENTIVO - CORRECTIVO A EQUIPOS DRAGER",
      "dependencia": "IMSS-BIENESTAR",
      "siglas": "IMSS-BIENESTAR",
      "score": 0.1386337097387258
    },
    {
      "numero_procedimiento": "aa-86-x75-927006953-n-33-2023",
      "nombre_procedimiento": "MANTENIMIENTO DE EQUIPO INSTRUMEDICAL",
      "dependencia": "SSALUDTAB",
      "siglas": "SSALUDTAB",
      "score": 0.14180015628341014
    },
    {
      "numero_procedimiento": "aa-81-019-922010998-n-25-2025",
      "nombre_procedimiento": "SESEQ ADF 017 2025 PARTIDA PRESUPUESTAL 5354011",
      "dependencia": "SESA",
      "siglas": "SESA",
      "score": 0.1431438753437244
    },
    {
      "numero_procedimiento": "aa-86-x74-927006955-n-12-2023",
      "nombre_procedimiento": "CONTRATACIÓN DEL SERVICIO DE INSTALACIÓN, REPARACIÓN Y MANTENIMIENTO DE EQUIPO",
      "dependencia": "SSA-HRAEDJGC",
      "siglas": "SSA-HRAEDJGC",
      "score": 0.1455064594915516
    },
    {
      "numero_procedimiento": "aa-86-x75-927006974-n-106-2024",
      "nombre_procedimiento": "35701.-MANTENIMIENTO Y CONSERVACION DE MAQUINARIA Y EQUIPO",
      "dependencia": "SSALUDTAB",
      "siglas": "SSALUDTAB",
      "score": 0.15285304852791337
    }
  ]
}