  "html_url": "https://licitia.com.mx/licitacion/la-07-110-007000999-t-463-2024",
  "canonical": "https://licitia.com.mx/licitacion/la-07-110-007000999-t-463-2024",
  "id": "b9ac9d974f8043b4b366fcc7d5f102e9",
  "procedure_number": "LA-07-110-007000999-T-463-2024",
  "file_number": "E-2024-00043573",
  "title": "SUSTITUCIONDEL HOSPITAL GENERAL AGUSTIN O' HORANEN MERIDA, YUCATAN",
  "description": {
    "short": "No existen bienes alternativos o sustitutos, Único Oferente, Derechos exclusivos (patentes, licencias, derechos de autor u otros derechos exclusivos), o por obras de arte.",
    "detailed": "SUSTITUCIONDEL HOSPITAL GENERAL AGUSTIN O' HORANEN MERIDA, YUCATAN,ADQUISICION DE EQUIPO MEDICO DE ESPECIALIDADES"
  },
  "lifecycle": {
    "section": "concluido",
    "source_status": "ADJUDICADO PARCIAL",
    "moved_at": null
  },
  "buyer": {
    "agency": "SECRETARIA DE LA DEFENSA NACIONAL",
    "acronym": "SEDENA",
    "branch": "07 - DEFENSA NACIONAL",
    "buying_unit": "SUBDIRECCIÓN DE ADQUISICIONES",
    "requesting_unit": "unidad requiriente data",
    "requesting_group": "SUBDIRECCIÓN DE ADQUISICIONES",
    "entity": "TESORERÍA DE LA FEDERACIÓN",
    "slug": "sedena",
    "unit_slug": "subdireccion-de-adquisiciones-007000999"
  },
  "classification": {
    "procedure_type": "LICITACIÓN PÚBLICA",
    "contracting_type": "ADQUISICIONES",
    "publication_type": null,
    "character": "INTERNACIONAL BAJO LA COBERTURA DE TRATADOS",
    "fiscal_year": 2024,
    "law": "LEY DE ADQUISICIONES, ARRENDAMIENTOS Y SERVICIOS DEL SECTOR PÚBLICO",
    "legal_basis_id": "1",
    "exception_basis": "Art. 41 fr. I",
    "internal_control_number": "LA-007000999-S.A.S./083-2024",
    "supply_source_number": null
  },
  "schedule": {
    "published_at": "2024-05-02T21:50:58.000Z",
    "clarification_meeting_at": "2024-05-23T14:00:00.000Z",
    "clarification_questions_deadline_at": "2024-05-22T14:00:00.000Z",
    "clarification_responses_deadline_at": null,
    "bid_opening_at": "2024-06-12T15:00:00.000Z",
    "award_at": "2024-07-02T18:00:00.000Z",
    "estimated_contract_at": "2024-07-17T06:00:00.000Z",
    "site_visit_at": null,
    "estimated_work_start_at": null
  },
  "estimated_value": {
    "minimum": null,
    "maximum": null,
    "currency": "MXN",
    "updated_at": null
  },
  "lots": [
    {
      "number": "1",
      "name": "PARTIDA SOLA",
      "description": "PARTIDA SOLA",
      "requirement_group_id": "1",
      "items": [
        {
          "number": "1",
          "cucop_code": "53101-1129",
          "specific_item_code": "53101",
          "cucop_description": "531.048.0040 ANALIZADORES. ANALIZADOR CLINICO PORTATIL DE SANGRE. EQUIPO PORTATIL PARA LA DETERMINACION DE LOS SIGUIENTES ANALITOS Y PARAMETROS SELECCIONABLES DE ACUERDO A LAS NECESIDADES DE LAS UNIDADES MEDICAS: ANALITOS: GLUCOSA NITROGENO UREICO CREATININA. HEMOGLOBINA Y HEMATOCRITO. ELECTROLITOS GASES BILIRRUBINAS TRANSAMINASAS LACTATO. PARAMETROS: TIEMPO DE RESPUESTA VOLUMEN DE MUESTRA ALMACENAMIENTO DE INFORMACION.",
          "description": "ANALIZADOR CLÍNICO PORTÁTIL DE SANGRE",
          "requested_quantity": "6",
          "minimum_quantity": "6",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "2",
          "cucop_code": "56501-0028",
          "specific_item_code": "56501",
          "cucop_description": "ANALIZADOR DE SISTEMAS (EQ. DE COM., CINEMAT. O FOTOGRAF.)",
          "description": "ANALIZADOR DE DESFIBRILADORES Y MARCAPASOS",
          "requested_quantity": "1",
          "minimum_quantity": "1",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "3",
          "cucop_code": "56501-0028",
          "specific_item_code": "56501",
          "cucop_description": "ANALIZADOR DE SISTEMAS (EQ. DE COM., CINEMAT. O FOTOGRAF.)",
          "description": "ANALIZADOR DE INCUBADORAS PARA RECIÉN NACIDOS",
          "requested_quantity": "1",
          "minimum_quantity": "1",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "4",
          "cucop_code": "56501-0028",
          "specific_item_code": "56501",
          "cucop_description": "ANALIZADOR DE SISTEMAS (EQ. DE COM., CINEMAT. O FOTOGRAF.)",
          "description": "ANALIZADOR DE VENTILACIÓN MECÁNICA",
          "requested_quantity": "1",
          "minimum_quantity": "1",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "5",
          "cucop_code": "53101-1330",
          "specific_item_code": "53101",
          "cucop_description": "531.055.0024 ANGIOGRAFO ARCO MONOPLANAR. SISTEMA DE RAYOS \"\"X\"\" PARA ESTUDIOS DIAGNOSTICOS Y TERAPEUTICOS. CON LAS SIGUIENTES CARACTERISTICAS SELECCIONABLES DE ACUERDO A LAS NECESIDADES DE LAS UNIDADES MEDICAS: INTEGRADO POR UN ARCO AL PISO O AL TECHO CON LAS SIGUIENTES CARACTERISTICAS DE ACUERDO A APLICACIONES DIAGNOSTICAS Y DE TRATAMIENTO: ROTACION Y ANGULACION MOVIMIENTO AXIAL MANUAL O MOTORIZADO DEL INTENSIFICADOR DE IMAGEN O PANTALLA PLANA PARA AJUSTAR LA DISTANCIA FOCO-PACIENTE DISTANCIA VARIABLE ENTRE EL FOCO Y LA PANTALLA DEL INTENSIFICADOR DE IMAGEN PROFUNDIDAD DEL BRAZO MOVIMIENTOS MOTORIZADOS DEL ARCO DE VELOCIDAD VARIABLE CON ROTACION Y ANGULACION INTENSIFICADOR DE IMAGEN O PANTALLA PLANA CON PROTECCION CONTRA O ANTICOLISION. MESA PARA EL PACIENTE: CON MOVIMIENTO LONGITUDINAL Y TRANSVERSAL AJUSTE DE LA ALTURA CARGA MAXIMA DEL PACIENTE. SISTEMA DE RAYOS \"\"X : GENERADOR DE RAYOS \"\"X\"\" DE ALTA FRECUENCIA CONTROLADO POR MICROPROCESADOR CORRIENTE DEL GENERADOR TUBO DE RAYOS \"\"X\"\" CON DOS PUNTOS FOCALES CON CAPACIDAD DE ALMACENAMIENTO DE CALOR DEL ANODO Y CAPACIDAD DE DISIPACION DE CALOR POSICION MANUAL O AUTOMATICA. FILTRACION DE LA RADIACION. SISTEMA DE ADQUISICION: PROGRAMAS PARA FLUOROSCOPIA CON CONTROL DE DOSIS PROCESAMIENTO DIGITAL Y SELECCION DE FILTROS DE RAYOS \"\"X\"\" A IMPULSOS PARA FLUOROSCOPIA PULSADA. CADENA DIGITAL DE TV CON SALIDA DIGITAL CUATRO MONITORES DE ALTA RESOLUCION PANTALLA ANTIRREFLEJANTE CON ADAPTACION AUTOMATICA DEL BRILLO Y CONTRASTE A LAS CONDICIONES DE LA SALA. SUSPENSION A TECHO PARA COLOCACION DE MONITORES. MODULO O CONSOLA DE DESPLIEGUE QUE APORTE INFORMACION SOBRE: EL ESTADO DE ROTACION/ANGULACION DEL BRAZO MENSAJES DEL SISTEMA EL ESTADO DE CARGA DE LOS TUBOS. DE RAYOS \"\"X\"\" LA MODALIDAD FLUORO SELECCIONADA Y CAMPO DE LOS INTENSIFICADORES DE IMAGEN O CAMPOS O AREAS DE VISION O IMAGEN. MODULO PARA LECTURA DE LA TASA DE DOSIS DE RADIACION EN CGY/CM2/SEG Y CRONOMETRO. ESTACION DE TRABAJO CON MONITOR TECLADO ALFANUMERICO Y MOUSE. CAPACIDAD PARA ADQUISICION Y ALMACENAMIENTO DE SEÑALES FISIOLOGICAS Y SU DESPLIEGUE. PROCESAMIENTO DE IMAGEN: MATRICES Y VELOCIDADES DE ADQUISICION Y CON SUSTRACCION DIGITAL EN TIEMPO REAL.",
          "description": "ANGIÓGRAFO ARCO EN \"C\" PARA HEMODINAMIA (DE TECHO).",
          "requested_quantity": "1",
          "minimum_quantity": "1",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "6",
          "cucop_code": "53101-1347",
          "specific_item_code": "53101",
          "cucop_description": "531.088.0108 AUDIOMETRO AUTOMATICO. EQUIPO PARA LA DETECCION INICIAL DE LA CAPACIDAD AUDITIVA DEL PACIENTE MEDIANTE PROGRAMA DE AUDIOMETRIA AUTOMATICA. CON LAS SIGUIENTES CARACTERISTICAS SELECCIONABLES DE ACUERDO A NECESIDADES DE LAS UNIDADES MEDICAS: CON DIFERENTES FRECUENCIAS DE ESTIMULO; RANGO VARIABLE DEL ATENUADOR; PRESENTACION DEL TONO EN INTERVALOS ALEATORIOS. DURACION DEL TONO: CONTINUO Y PULSADO CON FRECUENCIA DE REPETICION; PROGRAMA CON UMBRAL AUTOMATICO DE FRECUENCIA SENCILLA; MODO MANUAL CON MONITOREO AUTOMATICO DE ERROR. CALCULOS: UMBRAL PORCENTAJE DE IMPEDIMENTO BINAURAL Y PROMEDIOS. FUNCIONES DE REPORTE. AUDIOMETRO CON INTERFASE PARA COMUNICACION CON PC COMPATIBLE. PROCESADOR. DISCO DURO. MEMORIA INTERNA RAM. UNIDADES PARA DISCO DE 3.5\"\" Y PARA DISCO COMPACTO. MONITOR SVGA.",
          "description": "AUDIÓMETRO AUTOMÁTICO",
          "requested_quantity": "1",
          "minimum_quantity": "1",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "7",
          "cucop_code": "53101-1348",
          "specific_item_code": "53101",
          "cucop_description": "531.088.0157 AUDIOMETRO CLINIC.. EQUIPO EMPLEADO PARA REALIZAR PRUEBAS DE EVALUACION AUDITIVA. CON LAS SIGUIENTES CARACTERISTICAS SELECCIONABLES DE ACUERDO A NECESIDADES DE LAS UNIDADES MEDICAS: RANGO DE FRECUENCIA EN 2 CANALES CON ESTIMULO DE TONO PURO: VIA AEREA ALTA FRECUENCIA VIA OSEA; CAMPO LIBRE EXACTITUD ± 1%; RANGO DE INTENSIDAD: VIA AEREA; ALTA FRECUENCIA; VIA OSEA EN MASTOIDES Y FRENTE. MICROFONO PARA PRUEBAS DE VOZ E INTERCOMUNICACION. RANGO DE INTENSIDAD DE ENMASCARAMIENTO CALIBRADO EN ENMASCARAMIENTO EFECTIVO. RUIDO DE BANDA ANGOSTA. RUIDO BLANCO. FORMATO DE SEÑAL: CONTINUO PULSADO Y FRECUENCIA MODULADA. PROCESADOR DISCO DURO. MEMORIA INTERNA RAM. UNIDAD DE DISCO DE 3.5\"\" Y UNIDAD DE DISCO COMPACTO. MONITOR SVGA. INTERFASE PARA IMPRESORA.",
          "description": "AUDIÓMETRO CLÍNICO.",
          "requested_quantity": "1",
          "minimum_quantity": "1",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "8",
          "cucop_code": "53101-1395",
          "specific_item_code": "53101",
          "cucop_description": "531.157.0062 CAMARA SONOAMORTIGUADA CON COMPARTIMIENTO SENCILLO. UNIDAD AISLANTE DE RUIDO QUE SE UTILIZA PARA REALIZAR AUDIOMETRIAS CON FINES DE DIAGNOSTICO. PISO CUBIERTO CON ALFOMBRA PARA TRANSITO PESADO O MATERIAL ACUSTICO AISLADO. PUERTA ACUSTICA SELLADA. VENTANA PARA OBSERVACION CON DOBLE CRISTAL PARA AISLAMIENTO ACUSTICO (MINIMO 7 MM DE ESPESOR). REPISA EXTERIOR PARA COLOCACION DE AUDIOMETRO Y ACCESORIOS. RECEPTACULO O TABLERO PARA INTERCONEXION DEL EXTERIOR AL INTERIOR DE LA CAMARA. ILUMINACION INTERIOR INCANDESCENTE O FLUORESCENTE. PAREDES ACUSTICAS CON SISTEMA DE VENTILACION INTEGRADO CON NIVEL MAXIMO DE RUIDO DE 22 DB O MENOR A 500 HZ. DIMENSIONES EXTERIORES: ALTURA: ENTRE 190 Y 215 CM PROFUNDIDAD NO MENOR A 120 CM ANCHO NO MENOR A 120 CM. SISTEMA DE AISLAMIENTO DE VIBRACIONES. AISLAMIENTO A RUIDO DE 40 DB O MAYOR A 500 HZ",
          "description": "CÁMARA SONO-AMORTIGUADORA CON COMPARTIMIENTO SENCILLO",
          "requested_quantity": "2",
          "minimum_quantity": "2",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "9",
          "cucop_code": "53101-1381",
          "specific_item_code": "53101",
          "cucop_description": "531.146.1577 BRONCOSCOPIO FLEXIBLE DE FIBRA OPTICA. EQUIPO PORTATIL DE DIAGNOSTICO Y TRATAMIENTO PARA VIAS AEREAS ALTAS Y BAJAS CON CAPACIDAD PARA LA EXTRACCION DE CUERPOS EXTRAÑOS INVASIVO. TUBO DE INSERCION ENTRE 5.9 Y 6 MM DE DIAMETRO. LONGITUD DE 55 A 60 CM. CANAL DE TRABAJO DENTRO DEL RANGO DE 2.6 A 2.8 MM. ANGULOS DE FLEXION ARRIBA: MAYOR DE 170 GRADOS ABAJO: MAYOR DE 120 GRADOS. FUENTE DE LUZ MINIMO DE 150 WATTS. HALOGENA. AJUSTE DE INTENSIDAD DE LUZ. ESTUCHE RIGIDO PARA GUARDA. PINZA DE BIOPSIA.",
          "description": "BRONCOSCOPIO FLEXIBLE DE FIBRA ÓPTICA",
          "requested_quantity": "1",
          "minimum_quantity": "1",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "10",
          "cucop_code": "53101-1408",
          "specific_item_code": "53101",
          "cucop_description": "531.157.0786 CAMARA DIGITAL NO MIDRIATICA PARA FONDO DE OJO CON CAPACIDAD PARA ESTUDIOS DE FLUORANGIOGRAFIA. CAMARA DIGITAL OFTALMOLOGICA UTILIZADA PARA FOTOGRAFIAR Y REGISTRAR IMAGENES DEL FONDO DEL OJO SIN NECESIDAD DE DILATAR LA PUPILA; CON CAPACIDAD PARA REALIZAR ESTUDIOS DE FLUORANGIOGRAFIA. CON LAS SIGUIENTES CARACTERISTICAS SELECCIONABLES DE ACUERDO A NECESIDADES DE LAS UNIDADES MEDICAS: ANGULOS DE CONVERGENCIA O DE CAMPO DEL SEGMENTO ANTERIOR Y POSTERIOR: UNO OBLIGATORIO DE 45° Y EL OTRO DE 50° O 30°. ENFOQUE: FIJACION INTERNA DEL OJO; BRAZO INTERCONSTRUIDO CON PUNTO DE FIJACION EXTERNA; ALINEACION MANUAL; ENFOQUE AUTOMATICO Y MANUAL A PARTIR DEL OBSERVADOR. ILUMINACION: PARA VISUALIZAR Y ENFOCAR POR MEDIO DE FUENTE DE LUZ INFRARROJA; PARA FLUORANGIOGRAFIA CAPAZ DE REALIZAR SECUENCIAS DE IMAGENES; FLASH INTEGRADO DE XENON CON INTENSIDAD MODULABLE. IMAGENES: DESPLIEGUE DE IMAGEN EN TIEMPO REAL A TRAVES DE MONITOR DE LCD O TFT; CAPTURA DE IMAGENES DIGITALES; CAPAZ DE REALIZAR SECUENCIAS DE IMAGENES PARA ESTUDIO DE FLUOROANGIOGRAFIA. FILTROS: MODO DE CAPTURA POR MANIPULACION O A TRAVES DE FILTROS: VERDE O LIBRE DE ROJO; AZUL COLOR. QUE CUENTE CON AL MENOS LOS SIGUIENTES FILTROS: FILTRO PARA BLOQUEAR LUZ ULTRAVIOLETA FILTRO AUTOFLUORESCENCIA Y FILTRO FOTOFLUORANGIOGRAFIA. AJUSTE DE LA DISTANCIA DE TRABAJO: A TRAVES DE PALANCA DE MANDO. MOVIMIENTO DE LA BASE Y LA MENTONERA INDEPENDIENTES: MOVIMIENTO DE LA MENTONERA AJUSTABLE; MOVIMIENTOS DE LA BASE AJUSTABLES EN LOS EJES X Y Y Z OPTICA: CAPAZ DE TRABAJAR CON PUPILAS DE UN DIAMETRO DESDE 3.3 MM; MAGNIFICACION DIGITAL; COMPENSACION DE AMETROPIA DEL USUARIO EN CASO DE USAR OCULAR; COMPENSACION DE LA CORRECCION DE DIOPTRIAS DEL PACIENTE EN EL RANGO DE AL MENOS -30 DIOPTRIAS A +30 DIOPTRIAS. CAMARA DIGITAL: CON RESOLUCION DEL SENSOR DE IMAGEN DIGITAL A COLOR DE 5 MEGAPIXELES O MAYOR; CAPAZ DE PROPORCIONAR ZOOM DIGITAL. COMPUTADORA INTERNA O EXTERNA: CON CAPACIDAD PARA ALMACENAR MINIMO 60000 IMAGENES O 320 GBITES O MAYOR; QUE INCLUYA TECLADO Y MOUSE; GRABADOR DE DVD Y CD; TENGA CAPACIDAD DE INTERFASE A UNA USB VGA Y RED; SOFTWARE DE LA MISMA MARCA DEL EQUIPO CON LICENCIAS PARA: MANIPULACION O PROCESAMIENTO DE IMAGEN AJUSTES DE ILUMINACION NOTAS FOTOGRAFIA PANORAMICA FOTOGRAFIA ESTEREO BASE DE DATOS DEL PACIENTE; MAGNIFICACION DIGITAL DE LAS IMAGENES; CAPAZ DE GUARDAR EXPORTAR E IMPRIMIR LOS DATOS DE LA IMAGEN DE AL MENOS EN LOS FORMATOS AL BMP JPG Y DICOM.",
          "description": "CÁMARA DIGITAL NO MEDIATRICA PARA FONDO DE OJO, CON CAPACIDAD PARA ESTUDIOS DE FLUORANGIOGRAFIA",
          "requested_quantity": "1",
          "minimum_quantity": "1",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "11",
          "cucop_code": "53101-1410",
          "specific_item_code": "53101",
          "cucop_description": "531.165.0021 CAMPIMETRO COMPUTARIZADO. EQUIPO COMPUTARIZADO FIJO EMPLEADO PARA LA DETERMINACION DEL CAMPO VISUAL Y ESCOTOMAS UTILIZADO CON FINES DE DIAGNOSTICO Y TRATAMIENTO. CAMPIMETRO CON MODERNA TECNOLOGIA PARA LA DETERMINACION DE ESCOTOMAS Y ESTUDIOS DEL CAMPO VISUAL. CON MONITOR DE TUBO DE RAYO CATODICO INTEGRADO CON PANTALLA SENSIBLE AL TACTO Y TECLADO ALFANUMERICO. COMPUTADORA CON MICROPROCESADOR INTEGRADO. DISCO DURO CON 1.2 GB O MAYOR MEMORIA RAM DE 32 MB O MAYOR UNIDAD DE DISCO FLEXIBLE DE 3.5\"\" HEMIESFERA DE 30 CM DE DIAMETRO PARA DISTANCIA DE EXAMENES A 30 CMS. INTENSIDAD LUMINICA DE LA ESFERA DE 31.5 ASB. LONGITUD DE ONDA DE TODO EL ESPECTRO VISIBLE PARA: PRUEBAS CINETICAS CON ESTIMULO GOLDMAN. PARA TEMPRANO RECONOCIMIENTO DE GLAUCOMA. MENTONERA Y CABEZAL DE APOYO SON AUTOMATICOS Y PERMANENTEMENTE CONTROLADOS EN SU POSICION DURANTE TODO EL EXAMEN.",
          "description": "CAMPÍMETRO COMPUTARIZADO",
          "requested_quantity": "2",
          "minimum_quantity": "2",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "12",
          "cucop_code": "53101-1417",
          "specific_item_code": "53101",
          "cucop_description": "531.191.0391 CARRO ROJO CON EQUIPO COMPLETO PARA REANIMACION CON DESFIBRILADOR-MONITOR-MARCAPASO. CARRO RODABLE CON SISTEMA DE FRENO PARA REALIZAR LAS MANIOBRAS DE REANIMACION CARDIOVERSION Y DESFIBRILACION CARDIOPULMONAR. CON COMPARTIMIENTOS PARA ACCESORIOS AL MENOS UNO DE ELLOS CON DISPOSITIVO DE SEGURIDAD. CON SOPORTE PARA LA TABLA DE COMPRESIONES CARDIACAS EXTERNAS Y PARA TANQUE DE OXIGENO. POSTE DE ALTURA AJUSTABLE PARA INFUSIONES. REANIMADOR PULMONAR. CON EQUIPO PARA INTUBACION ENDOTRAQUEAL. EQUIPO DE MONITOREO CONTINUO CON PANTALLA DE DESPLIEGUE DE AL MENOS ECG SATURACION DE OXIGENO Y FRECUENCIA CARDIACA. ENERGIA PARA DESCARGA EXTERNA SELECCIONABLE. ALARMAS VISIBLES Y AUDIBLES. INDICADORES. CAPACIDAD DE MEMORIA DE ACUERDO A LAS NECESIDADES. REGISTRO EN PAPEL TERMICO DE TENDENCIAS. PALETAS PEDIATRICAS Y ADULTO PARA DESFIBRILACION Y CARDIOVERSION. CON SELECTOR DE MODO. CON OPCION DE DESCARGA. CON SISTEMA DE SUSPENSION DE LA CARGA. CON SISTEMA PARA PROBAR DESCARGA. BATERIA RECARGABLE QUE GARANTICE AL MENOS 30 DESFIBRILACIONES A CARGA MAXIMA. CON TIEMPO DE CARGA COMPLETA DE LA BATERIA. CON ENERGIA BIFASICA. MARCAPASO EXTERNO TRANSCUTANEO INTERCONSTRUIDO. SELECCIONABLE EN INTERVALOS. FRECUENCIA DE MARCAPASO AJUSTABLE. ACTIVACION POR MODOS: FIJO O ASINCRONICO Y A DEMANDA O SINCRONICO.",
          "description": "CARRO ROJO CON EQUIPO COMPLETO PARA REANIMACIÓN CON DESFIBRILADOR MONITOR MARCAPASO",
          "requested_quantity": "59",
          "minimum_quantity": "59",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "13",
          "cucop_code": "53101-1433",
          "specific_item_code": "53101",
          "cucop_description": "531.225.0011 COLPOSCOPIO. EQUIPO RODABLE DE MAGNIFICACION VISUAL CON FINES DE DIAGNOSTICO Y TRATAMIENTO DE PATOLOGIAS EN VAGINA O CERVIX. CON LAS SIGUIENTES CARACTERISTICAS SELECCIONABLES DE ACUERDO A LAS NECESIDADES DE LAS UNIDADES MEDICAS: MONTADO EN BRAZO ARTICULADO Y AUTOCOMPENSADO DE POSICIONAMIENTO SOLIDO SIN NECESIDAD DE CONTRAPESOS. TUBO BINOCULAR CON AJUSTE DE LA DISTANCIA INTERPUPILAR CON ANGULO DE INCLINACION. OCULARES GRANANGULARES PARA PORTADORES DE GAFAS CON COMPENSACION DE AMETROPIAS. ANTEOJERA INTEGRADA. CAMBIADOR DE AUMENTOS. ENFOQUE FINO. OBJETIVOS CAMBIABLES. OPCION DE CAMBIAR POR OBJETIVOS. FILTRO VERDE COMO MINIMO. QUE PERMITA LA ADAPTACION DE SISTEMA DE VIDEO O FOTOGRAFIA. HAZ DE LUZ DE ALTA INTENSIDAD. TRANSMISION DE LUZ POR FIBRA OPTICA. FUENTE DE LUZ. GUIAS DE LUZ.",
          "description": "COLPOSCÓPIO - CON CÁMARA Y MONITOR.",
          "requested_quantity": "3",
          "minimum_quantity": "3",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "14",
          "cucop_code": "53101-3659",
          "specific_item_code": "53101",
          "cucop_description": "537.260.0055 CRANEOTOMO NEUMATICO. EQUIPO PARA TREPANOTOMIA Y CRANEOTOMIA. CON LAS SIGUIENTES CARACTERISTICAS SELECCIONABLES DE ACUERDO A LAS NECESIDADES DE LAS UNIDADES MEDICAS: REDUCTOR DE VELOCIDAD Y ADITAMENTO PARA CRANEOPLASTIA.",
          "description": "CRANEOTOMO",
          "requested_quantity": "1",
          "minimum_quantity": "1",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "15",
          "cucop_code": "53101-1483",
          "specific_item_code": "53101",
          "cucop_description": "531.324.0151 ECOCARDIOGRAFO BIDIMENSIONAL DOPPLER COLOR AVANZADO. EQUIPO DE ALTA RESOLUCION QUE SE UTILIZA CON FINES DIAGNOSTICOS PARA EXPLORACION ULTRASONOGRAFICA INVASIVA Y NO INVASIVA EN TIEMPO REAL CON DOPPLER COLOR PARA ESTUDIOS CARDIACOS EN PACIENTES ADULTOS Y PEDIATRICOS. MONITOR A COLOR DE ALTA RESOLUCION DE 14 PULGADAS O MAYOR. SISTEMA DIGITAL DE 512 CANALES INDEPENDIENTES DE PROCESAMIENTO DIGITAL MODO B DOPPLER CONTINUO Y PULSADO DOPPLER COLOR Y SISTEMA DE MAPEO A COLOR (ANGIO POWER DOPPLER) MODO DE IMAGENES ARMONICAS EN MODO B Y ANGIO. MODO DOPPLER COLOR DE TEJIDO TRAZO AUTOMATICO DEL ESPECTRO DOPPLER Y CALCULOS DE: FRECUENCIA CARDIACA INDICE DE PULSATILIDAD INDICE DE RESISTENCIA VELOCIDAD MAXIMA Y MINIMA ACELERACION MAXIMA Y TIEMPO DE ACELERACION GASTO CARDIACO. RANGO DINAMICO DE 150 DB O MAYOR CON ADQUISICION DE MINIMO 300 CUADROS POR SEGUNDO. CON 256 ESCALAS DE GRISES Y 256 TONO DE COLOR COMO MINIMO. MEMORIA DE CINELOOP O CUADRO POR CUADRO DE MINIMO 400 CUADROS EN COLOR Y EN BLANCO Y NEGRO Y 100 SEGUNDOS EN MODO M O DOPPLER ESPECTRAL. PROGRAMA COMPLETO DE MEDICIONES EN MODO DOPPLER M Y 2D (MODO B) CON CALCULOS CARDIACOS Y VASCULARES: DIMENSIONES VOLUMENES DE VENTRICULO IZQUIERDO Y DERECHO MEDICION DE FRACCION DE EXPULSION MEDICION DE AREAS MEDICION DE MASAS DE VENTRICULO IZQUIERDO Y DERECHO MEDICION DE VELOCIDADES PENDIENTES Y ACELERACION METODO SIMPSON Y METODO BULLET. ZOOM. SUPERPOSICION DEL ECG.",
          "description": "ECOCARDIÓGRAFO BIDIMENSIONAL DOPPLER COLOR",
          "requested_quantity": "2",
          "minimum_quantity": "2",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "16",
          "cucop_code": "53101-1484",
          "specific_item_code": "53101",
          "cucop_description": "531.324.0169 ECOCARDIOGRAFO TRIDIMENSIONAL DOPPLER COLOR. EQUIPO UTILIZADO CON FINES DIAGNOSTICOS PARA EXPLORACION ULTRASONOGRAFICA INVASIVA Y NO INVASIVA EN TIEMPO REAL CON DOPPLER COLOR E IMAGEN EN 3D PARA ESTUDIOS CARDIACOS EN ADULTOS NIÑOS Y NEONATOS. MONITOR DE ALTA RESOLUCION DE MINIMO 14 PULGADAS. MODOS: SISTEMA DIGITAL CON 512 CANALES DE PROCESAMIENTO SIMULTANEO MODO B DOPPLER CONTINUO Y PULSADO DOPPLER COLOR Y SISTEMA DE MAPEO A COLOR (ANGIO POWER DOPPLER) MODO DE IMAGENES ARMONICAS CON MODO B ANGIO MODO DOPPLER COLOR DE TEJIDO DOPPLER INTELIGENTE O AUTOAJUSTABLE. CON 256 ESCALAS DE GRISES MEMORIA DE CINELOOP O CUADRO POR CUADRO DE 128 IMAGENES EN COLOR Y 256 EN BLANCO Y NEGRO COMO MINIMO. FUNCION DE ECO ESTRES INCLUIDA COMO UNA FUNCION DEL EQUIPO NO COMO UN EQUIPO DISTINTO Y EXTERNO. PROGRAMA COMPLETO DE MEDICIONES EN TIEMPO REAL EN MODO B CON CALCULOS Y MEDICIONES EN MODO B M DOPPLER PARA APLICACIONES CARDIACAS Y VASCULARES: MODO DE ADQUISICION DE IMAGENES CONTRASTADAS EN MODO B Y ANGIO SIMULTANEOS CON ARMONICAS. MEDICION DE DIMENSIONES MEDICION DE VOLUMENES LATIDO A LATIDO EN TIEMPO REAL MEDICION DE FRACCION DE EXPULSION LATIDO A LATIDO EN TIEMPO REAL MEDICION DE AREAS CARDIACAS EN TIEMPO REAL MEDICION DE MASAS MEDICION DE VELOCIDADES PENDIENTES ACELERACION/DESACELERACION METODO SIMPSON Y METODO BULLET O VOLUMEN POR AREA ENTRE LONGITUD COMO MINIMO PROGRAMA PARA EVALUACION DEL MOVIMIENTO LA CONTRACTILIDAD REGIONAL Y GLOBAL DEL MIOCARDIO ASI COMO LA FUNCION VENTRICULAR IZQUIERDA. ZOOM. CON CAPACIDAD DE SUPERPOSICION DEL ECG. CAPACIDAD DE INCORPORAR NUEVAS MEDICIONES O APLICACIONES Y NUEVOS TRANSDUCTORES.",
          "description": "ECOCARDIÓGRAFO TRIDIMENSIONAL DOPPLER COLOR",
          "requested_quantity": "1",
          "minimum_quantity": "1",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "17",
          "cucop_code": "53101-1336",
          "specific_item_code": "53101",
          "cucop_description": "531.072.0064 EQUIPO DE ARTROSCOPIA. EQUIPO PARA EL DIAGNOSTICO Y TRATAMIENTO DE PADECIMIENTOS ARTICULARES POR MINIMA INVASION. CAMISA DE ARTROSCOPIO CON LLAVES. Y OBTURADORES. CAMARA DE ALTA DEFINICION. MONITOR GRADO MEDICO. FUENTE DE LUZ. BOMBA DE IRRIGACION PARA ARTROSCOPIA. RASURADOR DE MOTOR PROGRESIVO. TODOS LOS ELEMENTOS DEL EQUIPO DEBEN SER COMPATIBLES ENTRE SI.",
          "description": "EQUIPO PARA ARTROSCOPIA (TORRE COMPLETA PARA ARTROSCOPIA)",
          "requested_quantity": "2",
          "minimum_quantity": "2",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "18",
          "cucop_code": "53101-1655",
          "specific_item_code": "53101",
          "cucop_description": "531.564.0267 EQUIPO PARA LAPAROSCOPIA. EQUIPO PORTATIL PARA LA VISUALIZACION DE CAVIDADES CON FINES DIAGNOSTICOS O TERAPEUTICOS. CON LAS SIGUIENTES CARACTERISTICAS SELECCIONABLES DE ACUERDO A LAS NECESIDADES DE LAS UNIDADES MEDICAS: CAMARA DE COLOR SENSIBLE. TECLADO. MONITORES DE VIDEO. FUENTE DE LUZ. GUIA DE LUZ DE FIBRA OPTICA. INSUFLADOR DE CO2. CILINDRO DE GAS PARA CO2 DE ALTA PRESION CON REGULADOR Y MANOMETRO. EQUIPO DE IRRIGACION/ASPIRACION SISTEMA DE VIDEOGRABACION. REGULADOR DE VOLTAJE CON ENTRADAS PARA TODOS LOS ELEMENTOS DEL EQUIPO. CARRO RODABLECON FRENOS EN AL MENOS 2 RUEDAS. TODOS LOS ELEMENTOS DEL EQUIPO DEBEN SER COMPATIBLES ENTRE SI.",
          "description": "EQUIPO PARA LAPAROSCOPIA (TORRE COMPLETA PARA LAPAROSCOPIA)",
          "requested_quantity": "2",
          "minimum_quantity": "2",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "19",
          "cucop_code": "53101-1799",
          "specific_item_code": "53101",
          "cucop_description": "531.829.0599 EQUIPO PORTATIL DE DIALISIS PERITONEAL AUTOMATIZADA PARA USO PEDIATRICO Y ADULTO. EQUIPO QUE REGULA AUTOMATICAMENTE LOS INTERCAMBIOS DE SOLUCION DIALIZANTE CON DIALISIS PERITONEAL EN PACIENTES PEDIATRICOS Y ADULTOS. 1.- EQUIPO PORTATIL PARA DIALISIS PERITONEAL POR MEDIO DE GRAVEDAD O SISTEMA HIDRONEUMATICO: 1.1.- PESO NO MAYOR DE 14 KG. 2.- CON BANDEJA O SISTEMA CALEFACTOR DEL LIQUIDO DE DIALISIS:2.1.- DENTRO DEL RANGO DE TEMPERATURA PRECONFIGURADO DE 35 °C +/- 2 °C. 3.- CON CAPACIDAD DE REALIZAR LAS SIGUIENTES TERAPIAS: 3.1.- DPN (DIALISIS PERITONEAL NOCTURNA) DPI (DIALISIS PERITONEAL INTERMITENTE) O DPIN (DIALISIS PERITONEAL INTERMITENTE NOCTURNA). 3.2.- DPCC (DIALISIS PERITONEAL CONTINUA CICLICA). 3.3.- MAREA (TIDAL). 4.- PARAMETROS PROGRAMADOS O INFERIDOS: 4.1.- CAPACIDAD DE INICIAR CON CICLO DE DRENAJE. 4.2.- CICLO DE PURGA O CEBADO O ENJUAGUE. 4.3.- VOLUMEN TOTAL DE TRATAMIENTO. 4.4.- VOLUMEN DE INFUSION: 4.4.1.- DE 60 ML O MENOR A 3000 ML O MAYOR. 4.5.- TIEMPO DE TRATAMIENTO: 4.5.1.- DE 8 HORAS O MENOR A 14 HORAS O MAYOR. 4.6.- VOLUMEN DE ULTIMA INFUSION: 4.6.1.- DE 60 ML O MENOR A 3000 ML O MAYOR 4.7.- OPCION DE ULTIMA INFUSION. 4.8.- TIEMPO DE DRENADO: 4.8.1.- DENTRO DE UN RANGO DE 1 A 59 MINUTOS. 4.9.- TIEMPO DE INFUSION: 4.9.1.- DENTRO DE UN RANGO DE 1 A 25 MINUTOS. 4.10.- PORCENTAJE MINIMO DE DRENADO: 4.10.1.- AL MENOS EL 80% DEL VOLUMEN DE INFUSION. 4.11.- OPCION DE INTERRUMPIR EL TRATAMIENTO. 5.- PARAMETROS DESPLEGADOS EN PANTALLA: 5.1.- VOLUMEN INFUNDIDO O CANTIDAD DE LIQUIDO A INFUNDIR 5.2.- VOLUMEN DE ULTRAFILTRACION 5.3.- TIEMPO DE PERMANENCIA 5.4.- TIEMPO DE DRENADO. 5.5.- VOLUMEN TOTAL DE TRATAMIENTO 5.6.- INDICACIONES PARA EL PROCEDIMIENTO DE CONEXION Y FIN DE PROCEDIMIENTO. 5.7.- ULTRAFILTRACION: 5.7.1.- ESPECIFICAR VALORES NEGATIVOS O DE RETENCION. 6.- ALARMAS: 6.1.- VISIBLES Y AUDIBLES: 6.1.1.- DE INFUSION (NO FLUJO OCLUSION O FLUJO LENTO). 6.1.2.- DE DRENAJE (NO FLUJO OCLUSION O FLUJO LENTO). 6.1.3.- DE FUGA DE LINEA O ALARMA DE FILTRACION EN LA BOMBA O ALARMA DE DIFERENCIA DE FLUJO. 6.1.4.- DE BAJA TEMPERATURA. 6.1.5.- DE ALTA TEMPERATURA. 6.2.- VISUALES Y/O AUDIBLES: 6.2.1.- FALLA EN EL SUMINISTRO DE LA ENERGIA ELECTRICA.",
          "description": "EQUIPO PORTÁTIL DE DIÁLISIS PERITONEAL AUTOMATIZADA PARA USO PEDIÁTRICO Y ADULTO",
          "requested_quantity": "16",
          "minimum_quantity": "16",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "20",
          "cucop_code": "53101-1826",
          "specific_item_code": "53101",
          "cucop_description": "531.848.0013 EQUIPO PORTATIL PARA TAMIZ AUDITIVO A TRAVES DE EMISIONES OTOACUSTICAS Y POTENCIALES AUDITIVOS AUTOMATIZADOS. EQUIPO QUE SIRVE PARA REALIZAR PRUEBAS OBJETIVAS DE TAMIZ AUDITIVO A RECIEN NACIDOS NIÑOS Y ADULTOS. CON LAS SIGUIENTES CARACTERISTICAS SELECCIONABLES DE ACUERDO A LAS NECESIDADES DE LAS UNIDADES MEDICAS: EQUIPO AUTOMATICO PORTATIL DE MANO PARA REALIZAR PRUEBAS AUDITIVAS EN AMBOS OIDOS. PESO NO MAYOR DE 600 GRAMOS. CON PROCESO DE CALIBRACION DEL EQUIPO DE FORMA AUTOMATICA. DESPLIEGUE DE RESULTADOS EN PANTALLA LCD. BOTONES O TECLAS PARA MANEJO DEL EQUIPO. CON CAPACIDAD DE REALIZAR PRUEBAS POR MEDIO DE: ABR O PEAA (POTENCIALES EVOCADOS AUDITIVOS AUTOMATIZADOS) Y DPOAE O EOAPD (EMISIONES OTOACUSTICAS POR PRODUCTOS DE DISTORSION) Y/O TEOAE O EOAT (EMISIONES OTOACUSTICAS POR TRANSITORIOS). RESULTADOS AUTOMATICOS SIN NECESIDAD DE INTERPRETACION. PASS (APTO). REFER (NO APTO). AMPLITUD MAXIMA DEL ESTIMULO PARA: EMISIONES OTOACUSTICAS POR TRANSITORIOS 84 DB SPL. EMISIONES OTOACUSTICAS POR PRODUCTOS DE DISTORSION 70DB SPL. ABR O PEAA DE 35 A 45 DB NHL COMO MINIMO EN PASOS DE 5 DB NHL. RANGO MINIMO DE FRECUENCIAS DE PRUEBA O ANCHO DE BANDA: PARA EMISIONES OTOACUSTICAS POR TRANSITORIOS DE 0.7KHZ. A 4KHZ. Y PARA EMISIONES OTOACUSTICAS POR PRODUCTOS DE DISTORSION 2KHZ. A 4KHZ. ABR O PEAA DE 100 HZ A 3000HZ. QUE PERMITA ELEGIR LA PRUEBA A REALIZAR: EMISIONES OTOACUSTICAS Y/O POTENCIALES EVOCADOS.CON TASA DE ESTIMULACION PARA POTENCIALES EVOCADOS POR CLICKS ENTRE 30 Y 60 POR SEGUNDO. MEDICION AUTOMATICA DE LA IMPEDANCIA. CRITERIO DE PASE AUTOMATIZADO. CAPACIDAD DE ALMACENAR 50 PRUEBAS COMO MINIMO EN MEMORIA INTERNA DE LA UNIDAD. DESPLIEGUE DE INFORMACION EN IDIOMA ESPAÑOL. INTERFASE PARA DESCARGAR DATOS A COMPUTADORA Y/O IMPRESORA. SOFTWARE DE BASE DE DATOS PARA MANEJO EN EQUIPO DE COMPUTO. ALARMAS O AVISOS VISIBLES DE AMBIENTE RUIDOSO ALTA IMPEDANCIA MALA COLOCACION Y BATERIA BAJA. QUE FUNCIONE CON BATERIAS RECARGABLES. CARGADOR Y PILAS ACORDE AL MODELO DEL EQUIPO. CON CABLE DE SONDA PARA PRUEBAS DE AL MENOS 1 METRO DE LONGITUD.",
          "description": "EQUIPO PORTÁTIL PARA TAMIZ AUDITIVO A TRAVÉS DE EMISIONES OTOACÚSTICAS",
          "requested_quantity": "1",
          "minimum_quantity": "1",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "21",
          "cucop_code": "51501-0032",
          "specific_item_code": "51501",
          "cucop_description": "ESTACION DE TRABAJO (EQ. DE COMPUTACION)",
          "description": "ESTACIÓN DE TRABAJO PARA INTERPRETACIÓN RIS - PACS",
          "requested_quantity": "2",
          "minimum_quantity": "2",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "22",
          "cucop_code": "53101-1585",
          "specific_item_code": "53101",
          "cucop_description": "531.385.1031 ESTERILIZADOR DE BAJA TEMPERATURA A TRAVES DE PLASMA DE PEROXIDO DE HIDROGENO. EQUIPO PARA ESTERILIZAR MATERIAL QUE NO RESISTE ALTAS TEMPERATURAS PRESION Y HUMEDAD. CONSTA DE: GABINETE VERTICAL CON SISTEMA DE SEGURIDAD QUE IMPIDA LA APERTURA DE PUERTA(S) DURANTE EL PERIODO DE ESTERILIZACION. CON CAMARA DE ESTERILIZACION. SISTEMA PARA LA ALIMENTACION DEL PEROXIDO DE HIDROGENO. CON PANTALLA DE CRISTAL LIQUIDO O SIMILAR. IMPRESOR INTEGRADO PARA REGISTRAR LOS DATOS DEL PROCESO DE ESTERILIZACION: PRESION TEMPERATURA HUMEDAD MENSAJES DE ERROR. CON RUEDAS PARA FACIL DESPLAZAMIENTO. QUE FUNCIONE CON UN MICROPROCESADOR. CON UN PROGRAMA QUE CONTROLE LOS PARAMETROS DE OPERACION Y QUE CONTROLE CADA UNA DE LAS ETAPAS DEL CICLO. LAS ESPECIFICACIONES DE CADA UNO DE LOS ELEMENTOS SEÑALADOS SERAN SELECCIONADOS POR LAS UNIDADES DE ACUERDO A SUS NECESIDADES.",
          "description": "ESTERILIZADOR DE BAJA TEMPERATURA A TRAVÉS DE PLASMA DE PERÓXIDO DE HIDRÓGENO",
          "requested_quantity": "3",
          "minimum_quantity": "3",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "23",
          "cucop_code": "53101-1587",
          "specific_item_code": "53101",
          "cucop_description": "531.385.1056 ESTERILIZADOR DE VAPOR AUTOGENERADO. EQUIPO FIJO PARA ESTERILIZAR EN FORMA MANUAL O AUTOMATICA OBJETOS QUE RESISTEN ALTAS TEMPERATURAS POR MEDIO DE VAPOR AUTOGENERADO. CON LAS SIGUIENTES CARACTERISTICAS SELECCIONABLES DE ACUERDO A LAS NECESIDADES DE LAS UNIDADES MEDICAS: TIPO GABINETE. FUNCIONAMIENTO MANUAL Y AUTOMATICO CONTROLADO POR MICROPROCESADOR. PREVACIO O REMOCION DE AIRE POR MEDIOS MECANICOS. CAMARA: DIMENSIONES Y MATERIAL. CHAQUETA Y CHASIS. AISLAMIENTO. CON PUERTAS DE APERTURA MANUAL. SISTEMA DE SEGURIDAD QUE IMPIDA LA APERTURA DURANTE EL PERIODO DE ESTERILIZACION. DESPLIEGUE DE LOS PARAMETROS DE ESTERILIZACION: TIEMPO PRESION TEMPERATURA. CON PROGRAMAS DE ESTERILIZACION QUE INCLUYAN: PREVACIO Y POSTVACIO RAPIDO O FLASH Y LIQUIDOS. TEMPERATURA AJUSTABLE. GRAFICADOR O IMPRESORA. ALARMAS AUDIBLES Y VISIBLES PARA MAL FUNCIONAMIENTO Y ERROR DE MANEJO. DEPOSITO DE AGUA. INDICADOR DE NIVEL DE AGUA EN EL DEPOSITO. TUBERIA SANITARIA.",
          "description": "ESTERILIZADOR DE VAPOR AUTOGENERADO 450 L",
          "requested_quantity": "5",
          "minimum_quantity": "5",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "24",
          "cucop_code": "53101-1587",
          "specific_item_code": "53101",
          "cucop_description": "531.385.1056 ESTERILIZADOR DE VAPOR AUTOGENERADO. EQUIPO FIJO PARA ESTERILIZAR EN FORMA MANUAL O AUTOMATICA OBJETOS QUE RESISTEN ALTAS TEMPERATURAS POR MEDIO DE VAPOR AUTOGENERADO. CON LAS SIGUIENTES CARACTERISTICAS SELECCIONABLES DE ACUERDO A LAS NECESIDADES DE LAS UNIDADES MEDICAS: TIPO GABINETE. FUNCIONAMIENTO MANUAL Y AUTOMATICO CONTROLADO POR MICROPROCESADOR. PREVACIO O REMOCION DE AIRE POR MEDIOS MECANICOS. CAMARA: DIMENSIONES Y MATERIAL. CHAQUETA Y CHASIS. AISLAMIENTO. CON PUERTAS DE APERTURA MANUAL. SISTEMA DE SEGURIDAD QUE IMPIDA LA APERTURA DURANTE EL PERIODO DE ESTERILIZACION. DESPLIEGUE DE LOS PARAMETROS DE ESTERILIZACION: TIEMPO PRESION TEMPERATURA. CON PROGRAMAS DE ESTERILIZACION QUE INCLUYAN: PREVACIO Y POSTVACIO RAPIDO O FLASH Y LIQUIDOS. TEMPERATURA AJUSTABLE. GRAFICADOR O IMPRESORA. ALARMAS AUDIBLES Y VISIBLES PARA MAL FUNCIONAMIENTO Y ERROR DE MANEJO. DEPOSITO DE AGUA. INDICADOR DE NIVEL DE AGUA EN EL DEPOSITO. TUBERIA SANITARIA.",
          "description": "ESTERILIZADOR DE VAPOR AUTOGENERADO - 250 LT DE 1 PUERTA",
          "requested_quantity": "2",
          "minimum_quantity": "2",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "25",
          "cucop_code": "53101-1145",
          "specific_item_code": "53101",
          "cucop_description": "531.385.1064 ESTERILIZADORES. ESTERILIZADOR DE VAPOR AUTOGENERADO PARA LABORATORIO. EQUIPO PARA ESTERILIZAR INSTRUMENTAL Y MATERIAL DE LABORATORIO EN FORMA MANUAL O AUTOMATICA POR MEDIO DE VAPOR AUTOGENERADO. ESTERILIZADOR DE VAPOR AUTOGENERADO. CON LAS SIGUIENTES CARACTERISTICAS SELECCIONABLES DE ACUERDO A LAS NECESIDADES DE LAS UNIDADES MEDICAS: CONTROLADO POR MICROPROCESADOR. OPERACION MANUAL Y/O AUTOMATICA. DESPLIEGUE DIGITAL E INDICADOR DE LOS PARAMETROS DE ESTERILIZACION: TIEMPO TEMPERATURA PRESION. TIPO GABINETE SEMIPORTATIL O PORTATIL. CAPACIDAD Y MATERIAL DE LA CAMARA. MEDIDAS EXTERNAS. DEPOSITO DE AGUA CON INDICADOR DE NIVEL DE AGUA. SISTEMA DE SEGURIDAD QUE IMPIDA LA APERTURA DE LA PUERTA DURANTE EL PERIODO DE ESTERILIZACION. IMPRESOR INTEGRADO PARA REGISTRO DE PRESION TIEMPO Y TEMPERATURA. ALARMAS AUDIBLES Y VISUALES. CON PREVACIO Y POSTVACIO. PROGRAMAS PARA EL CICLO DE ESTERILIZACION QUE INCLUYA SECADO.",
          "description": "ESTERILIZADOR DE VAPOR AUTOGENERADO PARA LABORATORIO",
          "requested_quantity": "1",
          "minimum_quantity": "1",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "26",
          "cucop_code": "53101-1351",
          "specific_item_code": "53101",
          "cucop_description": "531.088.0199 IMPEDANCIOMETRO AVANZADO. EQUIPO ELECTRONICO FIJO PARA REALIZAR ESTUDIOS DEL OIDO MEDIO. SE USA PARA PRUEBAS INICIALES DE TIPO: LABORAL CLINICAS Y DE INVESTIGACION. EL RESULTADO DE LAS PRUEBAS TIENE COMPONENTES NO OBJETIVOS PUES DEPENDERAN EN PARTE DE LA RESPUESTA VOLUNTARIA DEL PACIENTE. PARA OBTENER PRUEBAS EXITOSAS SE REQUIERE UN AMBIENTE SILENCIOSO Y LA ADECUADA PREPARACION Y COLABORACION DEL PACIENTE. CAPACIDAD PARA MEDIR LA INTEGRIDAD DEL TIMPANO. MODO MANUAL PARA PRUEBAS Y PROGRAMAS ESPECIALES MODO AUTOMATICO. SONDA CON TRES O MAS TONOS DE PRUEBA. TIMPANOMETRIA DE 2 COMPONENTES TIMPANOMETRIA MULTIFRECUENCIA MEDICION DE ADMITANCIA (Y) MEDICION DE SUCEPTANCIA (B) MEDICION DE CONDUCTANCIA (G). CAPACIDAD PARA PRUEBA DE REFLEJO ESTAPEDIAL (UMBRAL DE REFLEJO ACUSTICO) IPSILATERAL Y CONTRALATERAL. CON PRESENTACION DE TONO ACUSTICO AUTOMATICO O MANUAL. SELECCION DE TIEMPO DE ESTIMULACION. ESCALA DE SENSIBILIDAD AUTOAJUSTABLE O MANUAL. EVALUACION DE TROMPA DE EUSTAQUIO CON TIMPANO INTEGRO Y CON TIMPANO PERFORADO. PRUEBA DE FATIGA DE REFLEJO. CON DESPLIEGUE EN PANTALLA DEL TIEMPO DE FATIGA DEL REFLEJO. ESCALAS DE SENSIBILIDAD AJUSTABLES. INTERFASE RS-232 PARA COMUNICACION CON PC.",
          "description": "IMPEDANCIOMETRO AVANZADO",
          "requested_quantity": "1",
          "minimum_quantity": "1",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "27",
          "cucop_code": "53101-1520",
          "specific_item_code": "53101",
          "cucop_description": "531.341.0424 UNIDAD RADIOLOGICA Y FLUOROSCOPICA DE USO GENERAL. EQUIPO FIJO QUE PERMITE EFECTUAR ESTUDIOS RADIOGRAFICOS Y FLUOROSCOPICOS SIMPLES Y CONTRASTADOS CON FINES DIAGNOSTICOS. CON LAS SIGUIENTES CARACTERISTICAS SELECCIONABLES DE ACUERDO A LAS NECESIDADES DE LAS UNIDADES MEDICAS: GENERADOR DE RAYOS \"\"X\"\" DE ALTA FRECUENCIA. CORRIENTE EN MA AJUSTE EN KV. POTENCIA EN KW CON TIEMPO MINIMO DE EXPOSICION. TABLERO DE CONTROL. TUBOS. DE RAYOS \"\"X\"\" CON DOS PUNTOS FOCALES CADA UNO. CONTROL AUTOMATICO DE EXPOSICION. MESA BASCULABLE MOTORIZADA. CUBIERTA DESPLAZABLE EN CUATRO DIRECCIONES LONGITUDINAL Y LATERAL. BUCKY CON REJILLA FOCALIZADA. SERIOGRAFO AUTOMATICO ELECTRONICO CON DESPLAZAMIENTO MOTORIZADO A LO LARGO DE LA MESA CON EXPOSICIONES POR PLACA PARA CHASISES. INTENSIFICADOR DE IMAGEN O PANTALLA PLANA CON CAMPOS. CIRCUITO CERRADO DE TELEVISION. MONITOR DE TELEVISION. FLUOROSCOPIA PULSADA. CAMARA CCD DE ALTA RESOLUCION. MEMORIA DE IMAGENES FLUOROSCOPICAS. ZOOM DE IMAGEN CONGELADA. AJUSTE DEL NIVEL DE BRILLO Y DE LA AMPLITUD DE VENTANA DE LA IMAGEN DESPLEGADA. COLUMNA PORTATUBOS. CON FRENOS ELECTROMAGNETICOS CON SOPORTE DE PISO O PISO-TECHO. COLIMADOR. BUCKY VERTICAL. CON REJILLA FOCALIZADA.",
          "description": "KIT DE CONTROL DE CALIDAD PARA RAYOS X Y FLUOROSCOPÍA (FLUORO PHANTON)",
          "requested_quantity": "3",
          "minimum_quantity": "3",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "28",
          "cucop_code": "53101-1652",
          "specific_item_code": "53101",
          "cucop_description": "531.562.1473 LAMPARA DE HENDIDURA SIN FOTOGRAFIA.. EQUIPO FIJO MONTABLE SOBRE UN ESTATIVO O MESA DE ELEVACION QUE PERMITE LA EXPLORACION DEL OJO EN SU CONJUNTO (SEGMENTO ANTERIOR Y POSTERIOR) CON FINES DE DIAGNOSTICO Y TRATAMIENTO. MICROSCOPIO ESTEREOSCOPICO CON SELECTOR DE 5 AUMENTOS ENTRE 6X Y 40X CON TRES VALORES INTERMEDIOS. TUBO BINOCULAR CON AJUSTE DE LA DISTANCIA INTERPUPILAR. OCULARES 12.5X O MAYOR. CON CORRECTOR DE AMETROPIAS + 5 DIOPTRIAS O MAYOR. PROYECCION DE LA ANCHURA Y ALTURA DE LA HENDIDURA VARIABLE ENTRE 0 HASTA 9 MM O MAYOR. FILTROS: AZUL VERDE (EXENTO DE ROJO) FILTRO ANTITERMICO FIJO. FILTRO MATE (NEUTRO) ABATIBLE PARA ILUMINACION DIFUSA. ROTACION DE LA HENDIDURA DE + 90 GRADOS CON ESCALA ANGULAR PARA ANGULO DE DIFERENCIA. MOVIMIENTOS DE ESPEJO DE REFLEXION EN PLANO HORIZONTAL. INCLINACION DEL ANGULO DE INCIDENCIA DE 0 GRADOS HASTA 20 GRADOS CON CABEZAL DE PRISMA INTEGRADO. PALANCA DE MANDO MONO MANUAL PARA MOVER EL INSTRUMENTO EN LAS DIRECCIONES DE LAS TRES COORDENADAS CON UNA SOLA MANO SE REALIZAN LOS DESPLAZAMIENTOS GUIAS Y AJUSTES. AJUSTE VERTICAL PARA EL ACOMODO DISPOSICION DE ALTURA DEL PACIENTE BARBIQUEJO Y DE LA LAMPARA. DIODO-LAMPARA PARA PUNTO DE FIJACION. EL EQUIPO PUEDE FACILMENTE SER COMPLEMENTADO CON ACCESORIOS DE FOTOGRAFIA VIDEO Y OTROS ACCESORIOS. CON MESA ELECTROMOTORIZADA ASIMETRICA CON DESPLAZAMIENTO DE ALTURA. LENTE DE HRUBI PARA VISION DEL FONDO DEL OJO INCLUIDA. TONOMETRO DE APLANACION CON SOPORTE DE MONTAJE INCLUIDO.",
          "description": "LÁMPARA DE HENDIDURA",
          "requested_quantity": "2",
          "minimum_quantity": "2",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "29",
          "cucop_code": "53101-1546",
          "specific_item_code": "53101",
          "cucop_description": "531.350.0026 LASER QUIRURGICO NEODYNIUM-YAG. EQUIPO RODABLE UTILIZADO CON RAYO LASER CON REGULADOR DE INTENSIDAD. ENERGIA DE FOTODISRUPCION DE 2.8 MJ O MENOR EN EL AIRE. MODO SUPERGAUSSIANO ENERGIA MAXIMA: PULSO SENCILLO 10MJ PULSO DOBLE 25 MJ PULSO TRIPLE 40 MJ ATENUACION DE LA ENERGIA EN 9 ESCALONES DURACION DEL PULSO MENOR A 4NS FRECUENCIA DEL PULSO MAXIMO 2 HZ POSIBILIDAD DE DISPARO CON INTERRUPTOR MANUAL O PEDAL. DIAMETRO DEL FOCO: MINIMO 10 MICRAS EN AIRE. HAZ DE GUIA OJO DIODO LASER INTENSIDAD DE 670 NM REGULABLE EN FORMA CONTINUA CON SISTEMA DE ENFOQUE CUATRO PUNTOS POTENCIA DEL HAZ GUIA: 3 A 150 MICROWATTS. LAMPARA DE HENDIDURA INTEGRADA CON EL LASER FORMANDO UNA SOLA UNIDAD DEBE GARANTIZARSE LA VISTA Y ACCESO LIBRE AL OJO DEL PACIENTE. EL RAYO LASER Y EL EJE OPTICO DE LA LAMPARA DE HENDIDURA DEBEN ESTAR COAXIALMENTE ACOPLADOS. CON FILTRO PARA PROTECCION DEL CIRUJANO DE LOS REFLEJOS DEL LASER. PROVISTA DE DIODO ROJO CENTELLEANTE PARA LA FIJACION DE LA MIRADA DEL PACIENTE. CON PALANCA CENTRAL DE MANDO PARA ORIENTACION Y BLOQUEO RESPECTO AL OJO DEL PACIENTE. AUMENTOS VARIABLES ENTRE 5 X HASTA 30 X CON SISTEMA GALILEO. OCULARES 12.5 X PARA PORTADORES DE GAFAS Y COMPENSACION DE +/-8 DIOPTRIAS. REGULACION DEL ANCHO DE LA HENDIDURA DE 0 A 10 MM. ILUMINACION DE HALOGENO 12V 30W DE INTENSIDAD REGULABLE.",
          "description": "LÁSER QUIRÚRGICO OFTALMOLÓGICO.",
          "requested_quantity": "1",
          "minimum_quantity": "1",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "30",
          "cucop_code": "53101-1552",
          "specific_item_code": "53101",
          "cucop_description": "531.350.0133 LASER QUIRURGICO DE HOLMIO. EQUIPO PARA EXCISION INCISION ABLACION Y VAPORIZACION DE TEJIDOS SIN SANGRADO ADEMAS DE FRAGMENTACION DE CALCULOS. CONSTA DE GENERADOR LASER CON: LONGITUD DE ONDA POTENCIA DE PULSO DESPLIEGUE DE SALIDA FRECUENCIA EN HZ FIBRA OPTICA MODOS O FORMAS DE ONDA AMPLITUD DEL PULSO CONTROL DE EMISION ACTIVADO POR PEDAL HAZ DE GENERADOR LASER SISTEMA DE ENFRIAMIENTO INTEGRADO; MONITOR CON DESPLIEGUE Y MENSAJES DE ERROR DE FALLA CON PANTALLA SENSIBLE AL TACTO. LAS ESPECIFICACIONES DE CADA UNO DE LOS ELEMENTOS SEÑALADOS SERAN DETERMINADAS POR LAS UNIDADES MEDICAS DE ACUERDO A SUS NECESIDADES.",
          "description": "LASER HOLMIO DE 120 WATTS.",
          "requested_quantity": "1",
          "minimum_quantity": "1",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "31",
          "cucop_code": "53101-1552",
          "specific_item_code": "53101",
          "cucop_description": "531.350.0133 LASER QUIRURGICO DE HOLMIO. EQUIPO PARA EXCISION INCISION ABLACION Y VAPORIZACION DE TEJIDOS SIN SANGRADO ADEMAS DE FRAGMENTACION DE CALCULOS. CONSTA DE GENERADOR LASER CON: LONGITUD DE ONDA POTENCIA DE PULSO DESPLIEGUE DE SALIDA FRECUENCIA EN HZ FIBRA OPTICA MODOS O FORMAS DE ONDA AMPLITUD DEL PULSO CONTROL DE EMISION ACTIVADO POR PEDAL HAZ DE GENERADOR LASER SISTEMA DE ENFRIAMIENTO INTEGRADO; MONITOR CON DESPLIEGUE Y MENSAJES DE ERROR DE FALLA CON PANTALLA SENSIBLE AL TACTO. LAS ESPECIFICACIONES DE CADA UNO DE LOS ELEMENTOS SEÑALADOS SERAN DETERMINADAS POR LAS UNIDADES MEDICAS DE ACUERDO A SUS NECESIDADES.",
          "description": "LASER HOLMIO DE 30 WATTS.",
          "requested_quantity": "1",
          "minimum_quantity": "1",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "32",
          "cucop_code": "53101-1665",
          "specific_item_code": "53101",
          "cucop_description": "531.572.0549 LAVADORA DE EQUIPO DE INHALOTERAPIA. SISTEMA DE LAVADO Y PASTEURIZACION FIJO PARA LIMPIEZA Y DESINFECCION DE EQUIPO DE INHALOTERAPIA Y ANESTESIA. LAVADORA CON SISTEMA AUTOMATICO DE LAVADO Y PASTEURIZACION O DESINFECCION. CANASTILLA DE ACERO INOXIDABLE CON SOPORTES O SUJETADORES PARA COLOCAR TUBOS. MASCARILLAS CONECTORES Y ACCESORIOS DE INHALOTERAPIA Y ANESTESIA (CAPACIDAD PARA AL MENOS CINCO CIRCUITOS COMPLETOS). INYECTORES DE AGUA CALIENTE PARA LAVADO ENJUAGUE Y LIMPIEZA. SISTEMA DE CICLO DE LAVADO Y PASTEURIZACION DE 30 A 45 MINUTOS DE DURACION CADA UNO. PUERTA CON SISTEMA MANUAL O AUTOMATICO PARA COLOCAR Y SACAR LA CANASTILLA DENTRO DE LA LAVADORA. SISTEMA DE SEGURIDAD QUE EVITE LA APERTURA DE LA PUERTA DURANTE EL PROCESO DE LAVADO Y PASTEURIZACION O DESINFECCION. PANEL DE CONTROL PARA: ENCENDIDO Y APAGADO CICLO DE LAVADO CICLO DE PASTEURIZACION O DESINFECCION. INDICADOR VISUAL DE CICLO DE PASTEURIZACION. SISTEMA DE DRENADO.",
          "description": "LAVADORA DE EQUIPO DE INHALOTERAPIA",
          "requested_quantity": "1",
          "minimum_quantity": "1",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "33",
          "cucop_code": "53101-1686",
          "specific_item_code": "53101",
          "cucop_description": "531.609.0041 MARCAPASO CARDIACO EXTERNO.. EQUIPO PORTATIL QUE GENERA ESTIMULOS ELECTRICOS Y LOS TRANSMITE A TRAVES DE LA PIEL DEL TORAX DEL PACIENTE CON LA FINALIDAD DE SUSTITUIR EVENTUALMENTE LA FUNCION DEL MARCAPASO NATURAL DEL CORAZON. CONSTA DE LOS SIGUIENTES ELEMENTOS: MARCAPASO PERCUTANEO NO INVASIVO QUE EMITE PULSOS ELECTRICOS QUE SON TRANSMITIDOS A TRAVES DE LA PARED TORACICA CON FRECUENCIA DE DISPARO AJUSTABLE ENTRE 40 Y 170 POR MIN. CON INTENSIDAD DE 0 A 200 MA Y DURACION DEL PULSO DE +/- 1 MSEG. SE UTILIZA ONDA R PARA EMPLEO EN FORMA ASINCRONICA Y/O SINCRONICA. OPERA POR CORRIENTE ELECTRICA Y BATERIA. TOLERA EL EMPLEO DE DESFIBRILACION HASTA DE 400 J. A TRAVES DE LOS ELECTRODOS. INCLUYE CABLES DE ENTRADA Y SALIDA PARA ELECTROCARDIOSCOPIO Y DESFIBRILADOR ASI COMO ELECTRODOS PARA APLICACION A PACIENTE ADULTO Y PEDIATRICO.",
          "description": "MARCAPASO CARDÍACO EXTERNO",
          "requested_quantity": "24",
          "minimum_quantity": "24",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "34",
          "cucop_code": "53101-1533",
          "specific_item_code": "53101",
          "cucop_description": "531.341.2487 MASTOGRAFO DIGITAL. EQUIPO FIJO PARA REALIZAR ESTUDIOS RADIOLOGICOS DE MAMA CON ADQUISICION DE IMAGEN DIGITAL DE CAMPO COMPLETO.",
          "description": "MASTÓGRAFO DIGITAL CON ESTEREOTAXIA Y TOMOSÍNTESIS.",
          "requested_quantity": "1",
          "minimum_quantity": "1",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "35",
          "cucop_code": "53101-1707",
          "specific_item_code": "53101",
          "cucop_description": "531.616.5108 MESA QUIRURGICA UNIVERSAL ELECTROHIDRAULICA. MESA PARA FACILITAR EL PROCEDIMIENTO QUIRURGICO CON POSICIONES ADECUADAS PARA EL PACIENTE Y EL CIRUJANO. MESA PARA FACILITAR EL PROCEDIMIENTO QUIRURGICO CON POSICIONES ADECUADAS PARA EL PACIENTE Y EL CIRUJANO. CARACTERISTICAS GENERALES: MESA ELECTROHIDRAULICA RODABLE. CONTROLADA POR MICROPROCESADOR. QUE SOPORTE UN PESO DE 160 KG COMO MINIMO. CON SISTEMA DE FRENOS. LONGITUD TOTAL CON EXTENSION DE CABECERA Y PIERNAS DE 210 CM +/- 10 CM. BASE CON CUBIERTA DE ACERO INOXIDABLE O ACERO AL CROMO NIQUEL O POLIMERO RESISTENTE AL ALTO IMPACTO. CUBIERTA DE LA COLUMNA EN ACERO INOXIDABLE O ACERO AL CROMO NIQUEL. ESTRUCTURA DE LA SUPERFICIE EN ACERO INOXIDABLE O ACERO AL CROMO NIQUEL O ACERO AL CARBON PINTADO Y RIELES LATERALES EN ACERO INOXIDABLE O ACERO AL CROMO NIQUEL. SUPERFICIE RADIOTRANSPARENTE ACCESIBLE AL EQUIPO DE RAYOS X. MESA DIVIDIDA EN AL MENOS CUATRO SECCIONES: CABECERA; DORSO; PELVIS; MIEMBROS INFERIORES O PIERNAS. MIEMBROS INFERIORES O PIERNAS EN PLACAS INDEPENDIENTES DESMONTABLES ABATIBLES DE 0 A 90 GRADOS COMO MINIMO Y CON MOVIMIENTO DE TIJERA. CABECERA DESMONTABLE Y CON AJUSTE DE FLEXION CONTINUA DE +/- 20 GRADOS COMO MINIMO. LA MESA DEBE TENER LA CAPACIDAD PARA DAR LA POSICION DE NEFRECTOMIA. CONTROL REMOTO O DE MANO ALAMBICO PARA LOS MOVIMIENTOS ELECTROHIDRAULICOS. SISTEMA DE EMERGENCIA QUE PERMITA EL CONTROL DE TODOS LOS MOVIMIENTOS DE LA MESA EN CASO DE FALLA. FUNCION AUTOMATICA DE RETORNO DE LA MESA A LA POSICION HORIZONTAL. BATERIA CON INDICADOR DE CARGA. COJINES ELECTRICAMENTE CONDUCTIVOS O ANTIESTATICOS REMOVIBLES SIN COSTURAS Y DE FACIL LIMPIEZA. MOVIMIENTOS ELECTROHIDRAULICOS: ELEVACION Y DESCENSO QUE CUBRA EL RANGO DE 70 A 110 CM. +/- 10 CM. CON RESPECTO AL PISO; FOWLER DE 65 GRADOS COMO MINIMO; TRENDELENBURG DE 25 GRADOS COMO MINIMO; TRENDELENBURG INVERSO DE 20 GRADOS COMO MINIMO; INCLINACION LATERAL IZQUIERDA Y DERECHA DE 15 GRADOS COMO MINIMO. ACCESORIOS INCLUIDOS PARA CIRUGIA GENERAL Y GINECOLOGIA (ACCESORIOS DE LA MISMA MARCA DE LA MESA. LAS PARTES METALICAS DE LOS ACCESORIOS DEBEN SER EN ACERO INOXIDABLE O ACERO AL CROMO NIQUEL): ARCO DE ANESTESIA CON FIJADORES. SOPORTE ACOJINADO PARA BRAZO CON FIJADOR (2 PIEZAS). SOPORTE PARA HOMBROS ACOJINADOS CON FIJADORES (2 PIEZAS). SOPORTES LATERALES ACOJINADOS CON FIJADORES (2 PIEZAS). CINTURON PARA PACIENTE CON FIJADORES. PIERNERAS ARTICULADAS TIPO GOEPEL CON FIJADORES (2 PIEZAS). SOPORTE DE PIERNAS PARA POSICION DE LITOTOMIA. CHAROLA PORTACHASISES DE 35 X 43 CM (14 X 17 PULGADAS).",
          "description": "MESA QUIRÚRGICA PARA OBSTETRICIA - ELÉCTRICA",
          "requested_quantity": "3",
          "minimum_quantity": "3",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "36",
          "cucop_code": "53101-1708",
          "specific_item_code": "53101",
          "cucop_description": "531.616.5116 MESA QUIRURGICA UNIVERSAL AVANZADA. MESA PARA FACILITAR EL PROCEDIMIENTO QUIRURGICO CON POSICIONES ADECUADAS PARA EL PACIENTE Y EL CIRUJANO. MESA ELECTROHIDRAULICA RODABLE. CONTROLADA POR MICROPROCESADOR. QUE SOPORTE UN PESO DE 220* KG COMO MINIMO. CON SISTEMA DE FRENOS. LONGITUD TOTAL CON EXTENSION DE CABECERA Y PIERNAS DE 210 CM +/- 10 CM. BASE CON CUBIERTA DE ACERO INOXIDABLE O ACERO AL CROMO NIQUEL O POLIMERO RESISTENTE AL ALTO IMPACTO. CUBIERTA DE LA COLUMNA EN ACERO INOXIDABLE O ACERO AL CROMO NIQUEL. ESTRUCTURA DE LA SUPERFICIE Y RIELES LATERALES EN ACERO INOXIDABLE O ACERO AL CROMO NIQUEL. SUPERFICIE RADIOTRANSPARENTE ACCESIBLE AL EQUIPO DE RAYOS X. MIEMBROS INFERIORES O PIERNAS EN PLACAS INDEPENDIENTES DESMONTABLES ABATIBLES DE 0 A 90 GRADOS COMO MINIMO Y CON MOVIMIENTO DE TIJERA. CABECERA DESMONTABLE Y CON AJUSTE DE FLEXION CONTINUA DE +/- 20 GRADOS COMO MINIMO. LA MESA DEBE TENER LA CAPACIDAD PARA DAR LA POSICION DE NEFRECTOMIA. CONTROL REMOTO O DE MANO ALAMBICO PARA LOS MOVIMIENTOS ELECTROHIDRAULICOS. SISTEMA DE EMERGENCIA QUE PERMITA EL CONTROL DE TODOS LOS MOVIMIENTOS DE LA MESA EN CASO DE FALLA. CAPACIDAD DE SELECCIONAR LA ORIENTACION DEL PACIENTE. FUNCION AUTOMATICA DE RETORNO DE LA MESA A LA POSICION HORIZONTAL. BATERIA CON INDICADOR DE CARGA. COJINES ELECTRICAMENTE CONDUCTIVOS O ANTIESTATICOS REMOVIBLES SIN COSTURAS Y DE FACIL LIMPIEZA. CAPACIDAD DE INTERFACE Y COMUNICACION PARA UN QUIROFANO INTEGRADO. * PARA PACIENTE BARIATRICO SE PUEDE SOLICITAR OTRO VALOR MAYOR. MESA DIVIDIDA EN AL MENOS CUATRO SECCIONES: CABECERA DORSO PELVIS MIEMBROS INFERIORES O PIERNAS. MOVIMIENTOS ELECTROHIDRAULICOS: ELEVACION Y DESCENSO QUE CUBRA EL RANGO DE 70 A 110 CM. +/- 10 CM. CON RESPECTO AL PISO FOWLER DE 70 GRADOS COMO MINIMO TRENDELENBURG DE 25 GRADOS COMO MINIMO TRENDELENBURG INVERSO DE 25 GRADOS COMO MINIMO INCLINACION LATERAL IZQUIERDA Y DERECHA DE 20 GRADOS COMO MINIMO DESPLAZAMIENTO LONGITUDINAL DEL TABLERO DE 22 CM COMO MINIMO PARA UN OPTIMO ACCESO DEL ARCO EN C. ACCESORIOS INCLUIDOS PARA CIRUGIA GENERAL Y GINECOLOGIA (ACCESORIOS DE LA MISMA MARCA DE LA MESA. LAS PARTES METALICAS DE LOS ACCESORIOS DEBEN SER EN ACERO INOXIDABLE O ACERO AL CROMO NIQUEL): ARCO DE ANESTESIA CON FIJADORES POSTE PARA INFUSIONES CON FIJADOR SOPORTE ACOJINADO PARA BRAZO CON FIJADOR (2 PIEZAS) SOPORTE PARA HOMBROS ACOJINADOS CON FIJADORES (2 PIEZAS) SOPORTES LATERALES ACOJINADOS CON FIJADORES (2 PIEZAS) CINTURON PARA PACIENTE CON FIJADORES PIERNERAS ARTICULADAS TIPO GOEPEL CON FIJADORES (2 PIEZAS) SOPORTE DE PIERNAS PARA POSICION DE LITOTOMIA CHAROLA PORTACHASISES DE 35 X 43 CM (14 X 17 PULGADAS).",
          "description": "MESA QUIRÚRGICA UNIVERSAL AVANZADA - ELÉCTRICA",
          "requested_quantity": "11",
          "minimum_quantity": "11",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "37",
          "cucop_code": "53101-1708",
          "specific_item_code": "53101",
          "cucop_description": "531.616.5116 MESA QUIRURGICA UNIVERSAL AVANZADA. MESA PARA FACILITAR EL PROCEDIMIENTO QUIRURGICO CON POSICIONES ADECUADAS PARA EL PACIENTE Y EL CIRUJANO. MESA ELECTROHIDRAULICA RODABLE. CONTROLADA POR MICROPROCESADOR. QUE SOPORTE UN PESO DE 220* KG COMO MINIMO. CON SISTEMA DE FRENOS. LONGITUD TOTAL CON EXTENSION DE CABECERA Y PIERNAS DE 210 CM +/- 10 CM. BASE CON CUBIERTA DE ACERO INOXIDABLE O ACERO AL CROMO NIQUEL O POLIMERO RESISTENTE AL ALTO IMPACTO. CUBIERTA DE LA COLUMNA EN ACERO INOXIDABLE O ACERO AL CROMO NIQUEL. ESTRUCTURA DE LA SUPERFICIE Y RIELES LATERALES EN ACERO INOXIDABLE O ACERO AL CROMO NIQUEL. SUPERFICIE RADIOTRANSPARENTE ACCESIBLE AL EQUIPO DE RAYOS X. MIEMBROS INFERIORES O PIERNAS EN PLACAS INDEPENDIENTES DESMONTABLES ABATIBLES DE 0 A 90 GRADOS COMO MINIMO Y CON MOVIMIENTO DE TIJERA. CABECERA DESMONTABLE Y CON AJUSTE DE FLEXION CONTINUA DE +/- 20 GRADOS COMO MINIMO. LA MESA DEBE TENER LA CAPACIDAD PARA DAR LA POSICION DE NEFRECTOMIA. CONTROL REMOTO O DE MANO ALAMBICO PARA LOS MOVIMIENTOS ELECTROHIDRAULICOS. SISTEMA DE EMERGENCIA QUE PERMITA EL CONTROL DE TODOS LOS MOVIMIENTOS DE LA MESA EN CASO DE FALLA. CAPACIDAD DE SELECCIONAR LA ORIENTACION DEL PACIENTE. FUNCION AUTOMATICA DE RETORNO DE LA MESA A LA POSICION HORIZONTAL. BATERIA CON INDICADOR DE CARGA. COJINES ELECTRICAMENTE CONDUCTIVOS O ANTIESTATICOS REMOVIBLES SIN COSTURAS Y DE FACIL LIMPIEZA. CAPACIDAD DE INTERFACE Y COMUNICACION PARA UN QUIROFANO INTEGRADO. * PARA PACIENTE BARIATRICO SE PUEDE SOLICITAR OTRO VALOR MAYOR. MESA DIVIDIDA EN AL MENOS CUATRO SECCIONES: CABECERA DORSO PELVIS MIEMBROS INFERIORES O PIERNAS. MOVIMIENTOS ELECTROHIDRAULICOS: ELEVACION Y DESCENSO QUE CUBRA EL RANGO DE 70 A 110 CM. +/- 10 CM. CON RESPECTO AL PISO FOWLER DE 70 GRADOS COMO MINIMO TRENDELENBURG DE 25 GRADOS COMO MINIMO TRENDELENBURG INVERSO DE 25 GRADOS COMO MINIMO INCLINACION LATERAL IZQUIERDA Y DERECHA DE 20 GRADOS COMO MINIMO DESPLAZAMIENTO LONGITUDINAL DEL TABLERO DE 22 CM COMO MINIMO PARA UN OPTIMO ACCESO DEL ARCO EN C. ACCESORIOS INCLUIDOS PARA CIRUGIA GENERAL Y GINECOLOGIA (ACCESORIOS DE LA MISMA MARCA DE LA MESA. LAS PARTES METALICAS DE LOS ACCESORIOS DEBEN SER EN ACERO INOXIDABLE O ACERO AL CROMO NIQUEL): ARCO DE ANESTESIA CON FIJADORES POSTE PARA INFUSIONES CON FIJADOR SOPORTE ACOJINADO PARA BRAZO CON FIJADOR (2 PIEZAS) SOPORTE PARA HOMBROS ACOJINADOS CON FIJADORES (2 PIEZAS) SOPORTES LATERALES ACOJINADOS CON FIJADORES (2 PIEZAS) CINTURON PARA PACIENTE CON FIJADORES PIERNERAS ARTICULADAS TIPO GOEPEL CON FIJADORES (2 PIEZAS) SOPORTE DE PIERNAS PARA POSICION DE LITOTOMIA CHAROLA PORTACHASISES DE 35 X 43 CM (14 X 17 PULGADAS).",
          "description": "MESA QUIRÚRGICA UNIVERSAL AVANZADA - ELÉCTRICA ORTOPÉDICA",
          "requested_quantity": "2",
          "minimum_quantity": "2",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "38",
          "cucop_code": "53101-1722",
          "specific_item_code": "53101",
          "cucop_description": "531.626.0024 MICROSCOPIO PARA NEUROCIRUGIA. EQUIPO RODABLE NO INVASIVO DE PRECISION EN MICROSCOPIA UTILIZADO COMO AUXILIAR EN EL TRATAMIENTO QUIRURGICO. MICROSCOPIO DE CUERPO COMPACTO QUE PERMITA LA FACIL Y RAPIDA INTEGRACION Y CONVERSION DEL SISTEMA PARA SU USO ESPECIFICO O EN LA ESPECIALIDAD DE NEUROCIRUGIA. ESTATIVO DE PISO DE BASE COMPACTA MONTADO SOBRE RUEDAS QUE PERMITEN EL FACIL DESPLAZAMIENTO CON SISTEMA DE FRENADO. DESPLAZAMIENTO DEL MICROSCOPIO EN FORMA AGIL Y PRECISA EN CUALQUIER POSICION DESEADA BIEN SEA CON LA MANO O CON MANDO BUCAL. MANDO BUCAL INTEGRADO. CON CONTRAPESOS PARA LA NIVELACION Y COMPENSACION DEL EQUILIBRIO. ZOOM MOTORIZADO CON MARGEN DE EXPANSION FACTOR 1:6. ENFOQUE MOTORIZADO REGULABLE EN UN RANGO MINIMO DE 200 A 400 MM INCLINACION MANUAL DEL MICROSCOPIO CON ASEGURAMIENTO MAGNETICO QUE PERMITE LA RAPIDA DISPOSICION DEL MICROSCOPIO EN CUALQUIER POSICION DEL ESPACIO. SISTEMAS. DE ILUMINACION: ILUMINACION DE LUZ FRIA POR MEDIO DE FIBRA OPTICA. CONDICIONES DE ILUMINACION Y OBSERVACION IGUAL PARA DOS CIRUJANOS. CON AJUSTE DEL DIAMETRO DEL HAZ DE ILUMINACION. FUENTE DE LUZ DE ALTA POTENCIA CON LAMPARA DE XENON: POTENCIA DE SALIDA MINIMA DE 280 WATTS CON LAMPARA DE LUZ HALOGENA DE REPUESTO INTERCAMBIABLE AUTOMATICAMENTE O VIA INTERRUPTOR. LUZ DE ALTA ILUMINACION CONDUCIDA POR FIBRA OPTICA CON CARACTERISTICAS DE BRILLANTEZ Y CLARIDAD. SISTEMA DE OBJETIVO APOCROMATICO CON ZOOM PARA DISTANCIAS DE TRABAJO DE HASTA 400 MM O MAS. SISTEMA DE ENFOQUE INTEGRADO AUTOMATICO Y MANUAL. DISPOSITIVOS ESTEREOSCOPICOS: PARA OBSERVACION SIMULTANEA DE 2 CIRUJANOS QUE OBSERVEN EL MISMO CAMPO OPERATORIO CARA A CARA DE PIE. PARA OBSERVACION SIMULTANEA DE 2 CIRUJANOS QUE OBSERVEN EL MISMO CAMPO OPERATORIO CARA A CARA EN POSICION COMODA SENTADOS. QUE PERMITAN LA ADAPTACION DE ALGUN SISTEMA DE VIDEO O FOTOGRAFIA. TUBO BINOCULAR REGULABLE CON 2 OCULARES DE GRAN CAMPO 10X Y CONTROLES PARA EL AJUSTE DE LA DISTANCIA INTERPUPILAR. CUATRO OCULARES GRANANGULARES PARA PORTADORES DE LENTES Y CORRECTOR DE DIOPTRIAS. EL EQUIPO DEBERA ESTAR PROVISTO PARA PERMITIR LA ADAPTACION DE UN LASER DE CO2.",
          "description": "MICROSCOPIO PARA NEUROCIRUGÍA",
          "requested_quantity": "1",
          "minimum_quantity": "1",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "39",
          "cucop_code": "53101-1720",
          "specific_item_code": "53101",
          "cucop_description": "531.624.0026 MICROSCOPIO PARA OFTALMOCIRUGIA. AUXILIAR EN LAS INTERVENCIONES QUIRURGICAS DE OFTALMOLOGIA. COLUMNA -ESTATIVO RODABLE CON SISTEMA DE FRENADO. BRAZO ARTICULADO COMPENSADO Y DE CONTRABALANCEO. SISTEMA DE MOVIMIENTO XY MOTORIZADO CON BOTON DE PUESTA A CERO O PRECENTRADO AUTOMATICO. SISTEMAS. ZOOM (RELACION 1: 6) Y DE ENFOQUE FINO MOTORIZADOS. TUBO BINOCULAR OBLICUO CON DISPOSITIVO DE OBSERVACION SIMULTANEA CON OPTICA APOCROMATICA. OCULARES DE 10X O 12.5X GRAN ANGULARES CON AJUSTE DE AMETROPIAS. OBJETIVOS PARA DISTANCIA 175 O 200 MM. CON OPTICA APOCROMATICA DE GRAN CAMPO. PANTALLA DE PENUMBRA INTEGRADA E INTERCALABLE EN LA TRAYECTORIA DE LOS HACES. PEDAL DE CONTROL PARA TODAS LAS FUNCIONES IMPERMEABLE. SISTEMA DE ILUMINACION CON FUENTE DE LUZ FRIA DE HALOGENO. CONDUCTOR DE LUZ POR FIBRA OPTICA PARA DOS SISTEMAS. DE ILUMINACION COAXIAL E INCLINADO CONMUTABLES DESDE EL PEDAL DE CONTROL. INCLUYE FUNDA PROTECTORA Y SISTEMA QUE PERMITA ADAPTAR ACCESORIOS.",
          "description": "MICROSCOPIO PARA OFTALMOCIRUGÍA",
          "requested_quantity": "1",
          "minimum_quantity": "1",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "40",
          "cucop_code": "53101-1721",
          "specific_item_code": "53101",
          "cucop_description": "531.626.0016 MICROSCOPIO PARA OTORRINOLARINGOCIRUGIA.. EQUIPO PARA VISUALIZACION MICROSCOPICA DE LAS ESTRUCTURAS DE LA NARIZ OIDO Y GARGANTA. CONSTA DE LOS SIGUIENTES ELEMENTOS: BRAZO GIRATORIO ESTATIVO Y BRAZO BASCULANTE DE AUTOCOMPENSADO; SISTEMA QUE PERMITA MULTIPLES POSICIONAMIENTOS; CAMBIADOR MANUAL DE AUMENTOS; ENFOQUE FINO; TUBO BINOCULAR RECTO E INCLINABLE; OPTICAS CON AJUSTE DE DIOPTRIAS; CAMPO AMPLIO; OBJETIVOS PARA DISTANCIA DE TRABAJO CON OPTICA DE GRAN CAMPO; SISTEMA MODULAR QUE PERMITA ADAPTAR ACCESORIOS NECESARIOS; MOVIL CON FRENOS; ADAPTADOR PARA EL SISTEMA DE VIDEO; ILUMINACION DE SISTEMA CON FUENTE DE LUZ; LAMPARA DE RECAMBIO; CONDUCTORES DE LUZ POR FIBRA OPTICA E ILUMINACION COAXIAL INTEGRADA (LUZ FRIA). LAS ESPECIFICACIONES DE CADA UNO DE LOS ELEMENTOS SEÑALADOS SERAN DETERMINADAS POR LAS UNIDADES MEDICAS DE ACUERDO A SUS NECESIDADES.",
          "description": "MICROSCOPIO PARA OTORRINOLARINGOLOGÍA",
          "requested_quantity": "2",
          "minimum_quantity": "2",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "41",
          "cucop_code": "53101-1730",
          "specific_item_code": "53101",
          "cucop_description": "531.632.0554 CENTRAL DE MONITOREO PARA MULTIPLES CAMAS. SISTEMA DE VIGILANCIA DE CONSTANTES VITALES CON LAS SIGUIENTES CARACTERISTICAS SELECCIONABLES DE ACUERDO A LAS NECESIDADES DE LAS UNIDADES MEDICAS: QUE OPERE POR MICROPROCESADOR FIJO QUE REQUIERE DE INSTALACION ELECTRICA E INTERCONEXION ENTRE LOS ELEMENTOS QUE LO INTEGRAN. PARA DOCUMENTAR LOS PARAMETROS CON SOFTWARE Y ALARMAS QUE REQUIERAN LAS UNIDADES MEDICAS. TECLADO ALFANUMERICO Y RATON. IMPRESORA LASER. MONITORES MODULARES DE CABECERA.",
          "description": "CENTRAL DE MONITOREO PARA MÚLTIPLES CAMAS - 6 MONITORES",
          "requested_quantity": "1",
          "minimum_quantity": "1",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "42",
          "cucop_code": "53101-1730",
          "specific_item_code": "53101",
          "cucop_description": "531.632.0554 CENTRAL DE MONITOREO PARA MULTIPLES CAMAS. SISTEMA DE VIGILANCIA DE CONSTANTES VITALES CON LAS SIGUIENTES CARACTERISTICAS SELECCIONABLES DE ACUERDO A LAS NECESIDADES DE LAS UNIDADES MEDICAS: QUE OPERE POR MICROPROCESADOR FIJO QUE REQUIERE DE INSTALACION ELECTRICA E INTERCONEXION ENTRE LOS ELEMENTOS QUE LO INTEGRAN. PARA DOCUMENTAR LOS PARAMETROS CON SOFTWARE Y ALARMAS QUE REQUIERAN LAS UNIDADES MEDICAS. TECLADO ALFANUMERICO Y RATON. IMPRESORA LASER. MONITORES MODULARES DE CABECERA.",
          "description": "CENTRAL DE MONITOREO PARA MÚLTIPLES CAMAS - 10 MONITORES",
          "requested_quantity": "2",
          "minimum_quantity": "2",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "43",
          "cucop_code": "53101-1730",
          "specific_item_code": "53101",
          "cucop_description": "531.632.0554 CENTRAL DE MONITOREO PARA MULTIPLES CAMAS. SISTEMA DE VIGILANCIA DE CONSTANTES VITALES CON LAS SIGUIENTES CARACTERISTICAS SELECCIONABLES DE ACUERDO A LAS NECESIDADES DE LAS UNIDADES MEDICAS: QUE OPERE POR MICROPROCESADOR FIJO QUE REQUIERE DE INSTALACION ELECTRICA E INTERCONEXION ENTRE LOS ELEMENTOS QUE LO INTEGRAN. PARA DOCUMENTAR LOS PARAMETROS CON SOFTWARE Y ALARMAS QUE REQUIERAN LAS UNIDADES MEDICAS. TECLADO ALFANUMERICO Y RATON. IMPRESORA LASER. MONITORES MODULARES DE CABECERA.",
          "description": "CENTRAL DE MONITOREO PARA MÚLTIPLES CAMAS - 8 MONITORES",
          "requested_quantity": "5",
          "minimum_quantity": "5",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "44",
          "cucop_code": "53101-1530",
          "specific_item_code": "53101",
          "cucop_description": "531.341.2446 OSTEODENSITOMETRO. EQUIPO DE DIAGNOSTICO PARA MEDIR LA DENSIDAD OSEA POR RASTREO. PARA RASTREOS DE FEMUR COLUMNA AP CUERPO ENTERO COLUMNA LATERAL. BRAZO CON ROTACION DE 140 ° O MAS. DETECTOR DE DOBLE ENERGIA DE 570 ELEMENTOS O MAS. MESA DE ALTURA MOTORIZADA DE 65 CM O MENOS A 85 CM O MAS. TIEMPOS DE RASTREO: DE 12 SEG O MENOS PARA COLUMNA AP DE 12 SEG O MENOS PARA FEMUR DE 240 SEG O MENOS PARA CUERPO ENTERO. PRECISION DE 1.0% O MENOS. PROGRAMA INFORMATICO PARA CUANTIFICACION DEL TEJIDO CON INDICACION DE LA MASA GRASA Y LA MASA MAGRA. MORFOMETRIA EN 40 SEGUNDOS CON SOFTWARE DE ALTURA DE FORMACION VERTEBRAL.",
          "description": "OSTEODENSITÓMETRO",
          "requested_quantity": "1",
          "minimum_quantity": "1",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "45",
          "cucop_code": "53101-1528",
          "specific_item_code": "53101",
          "cucop_description": "531.341.2248 RAYOS X CON FLUROSCOPIA MOVIL ANALOGICO AVANZADO TIPO ARCO EN \"\"C\"\". EQUIPO MOVIL DE RADIOLOGIA CON FLUOROSCOPIA PARA DIAGNOSTICO CON SUSTRACCION DIGITAL EN TIEMPO REAL QUE UTILIZA UN BRAZO EN C Y APLICA TECNICAS ANALOGICAS O DE CONVERSION ANALOGICA A DIGITAL PARA LA CAPTURA PRESENTACION Y MANIPULACION DE IMAGENES PARA DIVERSAS APLICACIONES COMO LA EVALUACION VISUAL Y CUANTITATIVA DE LA ANATOMIA Y FUNCIONAMIENTO DE DIVERSAS ZONAS SELECCIONADAS. GENERADOR DE RAYOS X DE ALTA FRECUENCIA: POTENCIA DE 7 KW. O MAYOR KV. DE 40 O MENOR A 110 CORRIENTE EN FLUOROSCOPIA PULSADA O CONTINUA DE 15 MA. O MAYOR CORRIENTE DE RADIOGRAFIA DE 60 MA. O MAYOR. TUBO DE RAYOS X: DOS PUNTOS FOCALES UNO DE 0.3 MM. O MENOR Y EL OTRO DE 0.6 MM. O MENOR CAPACIDAD DE ALMACENAMIENTO DE CALOR TERMICO EN EL ANODO DE 270 KHU O MAYOR ANODO GIRATORIO O ROTATORIO. ARCO EN C: SID DE 90 CM. O MAYOR. DISTANCIA ENTRE FOCO E IMAGEN (SOURCE IMAGE DISTANCE) ROTACION DE +-110 GRADOS O MAYOR RECORRIDO HORIZONTAL RECORRIDO VERTICAL MOVIMIENTO PANORAMICO O LATERAL. CADENA DE IMAGEN DIGITAL O CAMARA DE VIDEO O CCD DE AL MENOS 1K X 1K O MAYOR A 12 BITS O MAYOR. DIAMETRO DEL INTENSIFICADOR DE IMAGEN DE 9\"\" O MAYOR DE 3 CAMPOS COMO MINIMO. SUSTRACCION DIGITAL EN TIEMPO REAL O SUSTRACCION DIGITAL ANGIOGRAFICA (DSA). ADQUISICION O ALMACENAMIENTO DE 30 IMAGENES O FRAMES/SEGUNDO O MAYOR. CAPACIDAD DE ALMACENAMIENTO DE 10000 IMAGENES O MAYOR O 100 GB O MAYOR. DICOM PRINT Y DICOM SEND O STORE DICOM WORKLIST AL MENOS. CON UNIDAD DE GRABACION CD-R O DVD EN FORMATO DICOM. SE DEBERA INCLUIR UN VISOR DICOM. CONSOLA DE CONTROL MOVIL: DOS MONITORES DE 18\"\" O MAYOR CON RESOLUCION DE 1K X 1K TECLADO ALFA NUMERICO DE CONTROL DE PROCESOS.",
          "description": "RAYOS X CON FLUOROSCOPÍA, MÓVIL DIGITAL TIPO ARCO EN C",
          "requested_quantity": "3",
          "minimum_quantity": "3",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "46",
          "cucop_code": "53101-1789",
          "specific_item_code": "53101",
          "cucop_description": "531.825.0619 SILLON PARA OTORRINOLARINGOLOGIA. EQUIPO FIJO DE OPERACION ELECTROHIDRAULICA QUE PERMITE LA REVISION DEL PACIENTE EN DIVERSAS POSICIONES LO QUE FACILITA EL ESTUDIO Y TRATAMIENTO DE PROBLEMAS EN OIDO NARIZ Y FARINGE. SILLON PARA PACIENTE CON AJUSTE DE ALTURA. OPERACION ELECTROHIDRAULICA O ELECTRICA EN LA BASE. GIRATORIO A 330 ° O MAYOR. SOPORTE AJUSTABLE PARA CABEZA. DESCANSAPIES AJUSTABLE. RECLINABLE HASTA POSICION HORIZONTAL INCLUYENDO LOS PIES. BRAZO ABATIBLE A 90 ° PARA FACIL ACCESO. ASIENTO TIPO STANDARD O CONVENCIONAL. CON PLATAFORMA Y CON RESPALDO RECLINABLE CON CONTROL DE POSICIONES MEDIANTE AJUSTE MANUAL.",
          "description": "SILLÓN PARA OTORRINOLARINGOLOGÍA",
          "requested_quantity": "1",
          "minimum_quantity": "1",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "47",
          "cucop_code": "53101-1512",
          "specific_item_code": "53101",
          "cucop_description": "531.340.0169 SISTEMA DE HEMODIALISIS PARA USO EN NEONATO PEDIATRICO Y ADULTO. EQUIPO PARA EL TRATAMIENTO DE PACIENTES CON FALLA RENAL O CON OTROS PADECIMIENTOS QUE REQUIERAN DESINTOXICACION SANGUINEA Y ELIMINACION DE EXCESO DE LIQUIDOS DEL ORGANISMO (ULTRAFILTRACION) PARA USO EN NEONATO PEDIATRICO Y ADULTO A TRAVES DE TERAPIAS DIALITICAS. 1.- MAQUINA DE HEMODIALISIS CON TECNOLOGIA BASADA EN MICROPROCESADORES. 2.- CON CAPACIDAD DE ADMINISTRACION DE DATOS A TRAVES DE UN SISTEMA DE COMPUTO. 3.- QUE TRABAJE CON BICARBONATO EN POLVO CARTUCHO O EN SOLUCION (PARA USO NO PARENTERAL). 4.- CON CONTROL DE PARAMETROS DE: 4.1.- TEMPERATURA DEL LIQUIDO DIALIZANTE DENTRO DEL RANGO DE 35 A 38 GRADOS CENTIGRADOS. 4.2.- FLUJO DEL LIQUIDO DIALIZANTE DENTRO DEL RANGO DE 300 A 800 ML/MIN O MAYOR. 4.3.- FLUJO DE SANGRE DENTRO DEL RANGO DE 15 ML/MIN A 500 ML/MIN. 4.4.- NIVEL DE BICARBONATO PROGRAMABLE (PARCIAL O PERFIL DE BICARBONATO) DURANTE EL PROCESO DE HEMODIALISIS DENTRO DEL RANGO DE 28 A 40 MEQ/L O 28 A 40 MMOL/L O 2.4 A 4 MS/CM. 4.5.- NIVEL DE SODIO PROGRAMABLE DURANTE EL PROCESO DE LA HEMODIALISIS DENTRO DEL RANGO DE 130 A 150 MEQ/L O 130 A 150 MMOL/L O 12.8 A 15.7 MS/CM. 4.6.- SISTEMA DE CONTROL DE LA ULTRAFILTRACION CON TASA DENTRO DEL RANGO DE 0.0 A 3 L/H. O DE 0.0 A 3 KG/H. 4.7.- SISTEMA INTEGRADO DE INFUSION PARA ANTICOAGULACION (BOMBA DE HEPARINA DE 0.5 ML/H A 5 ML/H). CON UN FLUJO DE INFUSION DENTRO DEL RANGO DE 0.1 A 9.9 ML/H EN INCREMENTOS DE 0.1ML/H. 5.- QUE CUENTE DENTRO DEL SISTEMA CON ALARMAS CRITICAS: 5.1.- PRESION ARTERIAL NO INVASIVA. 5.2.- DETECTOR DE AIRE. 5.3.- DETECTOR DE FUGAS SANGUINEAS. 6.- PANTALLA LCD O PLASMA O TECNOLOGIA SUPERIOR INTEGRADA A LA MAQUINA. 7.- CON CAPACIDAD DE INGRESAR AL MENOS TRES TIPOS DE PERFILES DE SODIO. 8.- CON DESPLIEGUE EN PANTALLA DE: 8.1.- PRESION ARTERIAL DEL CIRCUITO. 8.2.- PRESION VENOSA DEL CIRCUITO. 8.3.- PRESION TRANSMEMBRANA. 8.4.- FLUJO DE LIQUIDO DIALIZANTE. 8.5.- FLUJO DE SANGRE. 8.6.- TASA DE INFUSION DE HEPARINA. 8.7.- TASA DE ULTRAFILTRACION. 8.8.- CONDUCTIVIDAD DEL DIALIZANTE. 8.9.- VOLUMEN DE SANGRE PROCESADA. 8.10.- TEMPERATURA DEL LIQUIDO DIALIZANTE. 8.11.- PRESION ARTERIAL NO INVASIVA DEL PACIENTE (SISTOLICA Y DIASTOLICA) FRECUENCIA CARDIACA. 8.12.- TIEMPO TRANSCURRIDO O RESTANTE DE DIALISIS. 8.13.- VOLUMEN DE ULTRAFILTRACION CONSEGUIDO. 9.- CON SISTEMA DE ALARMAS AUDIBLES Y VISIBLES DE: 9.1.- PRESION ARTERIAL DEL CIRCUITO. 9.2.- PRESION VENOSA DEL CIRCUITO. 9.3.- PRESION TRANSMEMBRANA. 9.4.- FLUJO DEL LIQUIDO DIALIZANTE. 9.5.- FLUJO DE SANGRE. 9.6.- ULTRAFILTRACION. 9.7.- CONDUCTIVIDAD. 9.8.- TEMPERATURA DEL LIQUIDO DIALIZANTE. 9.9.- DETECTOR DE FUGAS SANGUINEAS. 9.10.- DETECTOR DE AIRE. 9.11.- FALLA EN EL SUMINISTRO DE AGUA. 9.12.- FALLA EN EL SUMINISTRO DE ENERGIA ELECTRICA. 9.13.- PRESION ARTERIAL NO INVASIVA. 10.- CON SISTEMA AUTOMATICO PARA DESINFECCION QUIMICA. 11.- CON SISTEMA AUTOMATICO PARA REMOCION DE SALES Y/O CON SISTEMA AUTOMATICO DE DESINFECCION TERMICA. 12.- GABINETE CON LAS SIGUIENTES CARACTERISTICAS: SUPERFICIES DE MATERIAL LAVABLE CON BASE RODABLE CON SISTEMA DE FRENOS. 13.- CAPACIDAD PARA GUARDAR LA INFORMACION DEL TRATAMIENTO EN CASO DE FALLA DE ENERGIA ELECTRICA. 14.- CON CAPACIDAD PARA REALIZAR EL RETORNO SANGUINEO EN FORMA MANUAL EN CASO DE FALLA ELECTRICA.\"\"",
          "description": "SISTEMA DE HEMODIÁLISIS PARA USO EN NEONATO PEDIÁTRICO Y ADULTO",
          "requested_quantity": "12",
          "minimum_quantity": "12",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "48",
          "cucop_code": "53101-1796",
          "specific_item_code": "53101",
          "cucop_description": "531.829.0243 SISTEMA DE MEDICION URODINAMICA.. EQUIPO COMPUTARIZADO FIJO PARA DIAGNOSTICO DE DISFUNCION URINARIA Y MEDICION DE PRESIONES Y CISTOMETRIA. SISTEMA COMPUTARIZADO INTEGRADO RODABLE DE URODINAMIA. CAPACIDAD DE 9 CANALES (3 INPUT Y 6 DISPLAY). COMPUTADORA INTEL PENTIUM 166 MHZ O MAYOR DISCO DURO DE 2.1 GB O MAYOR. CAPACIDAD DE MEMORIA DE 32 MB RAM O MAYOR. UNIDAD PARA DISCO FLEXIBLE DE 3.5Š. TECLADO MOUSE E IMPRESORA. EQUIPADO CON TRANSDUCTORES PARA ESTUDIOS DE: UROFLUJOMETRIA CISTOMETRIA Y PERFILOMETRIA. OPERACION DE LOS PROGRAMAS URODINAMICOS EN SISTEMA OPERATIVO Y MODO GRAFICO. TRES CANALES DE PRESION (0 100 Y 200 CM H2O): UN CANAL DE VOLUMEN UN CANAL DE FLUJOMETRIA UN CANAL EMG. MONITOR ALFAGRAFICO DE COLOR SVGA DE 15Š. PANEL DE CONTROL MEDIANTE EL CUAL SE PUEDEN REALIZAR MODIFICACIONES DE CURVAS MARCA EVENTOS CAMBIAR ESCALAS GENERAR REPORTES DE PACIENTES ETC. PERIFERICOS: UNIDAD CON BOMBA DE INFUSION DIGITAL ANALOGA CONTROLADA POR LA COMPUTADORA DE 5 A 180 ML/SEG Y 0-200 CMH2O. UNIDAD RETRACTOR DE CATETER UPP CON VELOCIDAD AJUSTABLE. UNIDAD DE ELECTROMIOGRAFIA.",
          "description": "SISTEMA DE MEDICIÓN URODINÁMICA",
          "requested_quantity": "2",
          "minimum_quantity": "2",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "49",
          "cucop_code": "53101-1492",
          "specific_item_code": "53101",
          "cucop_description": "531.327.0232 SISTEMA DE MONITOREO ELECTROCARDIOGRAFICO CONTINUO Y AMBULATORIO. EQUIPO FIJO OPERADO POR MICROPROCESADORES PARA REGISTRAR Y ALMACENAR INFORMACION DE LAS DERIVACIONES ELECTROCARDIOGRAFICAS PARA EL DIAGNOSTICO DE ALTERACIONES DEL RITMO Y DE LA CONDUCCION EN PACIENTES AMBULATORIOS. CONFORMADO POR UNA ESTACION DE ALMACENAMIENTO EDICION Y ANALISIS DE SEÑALES DE ECG. SISTEMA COMPUTARIZADO CON OPCION A ESCALAMIENTO CONTINUO DEL SOFTWARE INTEGRADO POR: GRABADORA DIGITAL CON OPCION A BATERIA RECARGABLE O BATERIAS ALCALINAS AA. TARJETA DE ESTADO SOLIDO. MARCADOR DE EVENTOS Y ANALISIS DE RUIDO DE LA SEÑAL. PESO DE 400 G O MENOR. CAPACIDAD DE GUARDAR LAS DERIVACIONES ELECTROCARDIOGRAFICAS DURANTE 24 HORAS COMO MINIMO. ADQUISICION SIMULTANEA DE 6 DERIVACIONES COMO MINIMO Y REGISTRO DE 3 CANALES O MAYOR. REGISTRO DIGITAL DE MARCAPASO. COMPUTADORA CON PROCESADOR DE 200 MHZ O MAYOR. MONITOR A COLOR DE ALTA RESOLUCION. DISCO DURO CON CAPACIDAD MINIMA DE 2.1 GB O MAYOR. CAPACIDAD DE ALMACENAMIENTO EN DISCO FLEXIBLE. SOFTWARE CON CAPACIDAD DE EDITAR SEÑALES DE ECG EN SISTEMA OPERATIVO Y MODO GRAFICO. REGISTRO DE 24 HORAS. REGISTRO DE ECG SELECCIONABLE DESPLEGADO CON BASE DE TIEMPO VARIABLE. GRAFICAS DE TENDENCIA DE FRECUENCIA CARDIACA. GRAFICAS DE TENDENCIA DEL NIVEL DEL SEGMENTO ST. REGISTRO DE 3 CANALES COMO MINIMO. ANALISIS DE POTENCIALES TARDIOS. REGISTRO DE FRECUENCIA MAXIMA Y MINIMA DE LA PRESENTACION DE LOS EVENTOS. VARIABILIDAD DE FRECUENCIA CARDIACA. DEBERA CONTAR CON COMPAS ELECTRONICO (CALIPER) PARA MEDICION DE VOLTAJE Y TIEMPO. PUERTO TIPO PCMCIA PARA LECTURA DE TARJETAS DE ESTADO SOLIDO. IMPRESION DE GRAFICAS DE: TENDENCIA DE FRECUENCIA ARRITMIAS VENTRICULARES MORFOLOGIAS TIPICAS.",
          "description": "SISTEMA DE MONITOREO ELECTROCARDIOGRÁFICO CONTINUO Y AMBULATORIO. - HOLTER CARDIACO",
          "requested_quantity": "2",
          "minimum_quantity": "2",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "50",
          "cucop_code": "53101-1801",
          "specific_item_code": "53101",
          "cucop_description": "531.829.0615 MONITORIZACION PARA PRUEBAS DE ESFUERZO CARDIACO SISTEMA DE. EQUIPO PARA LA AUTOMATIZACION DE LA PRUEBA DE ESFUERZO. CON LAS SIGUIENTES CARACTERISTICAS SELECCIONABLES DE ACUERDO A LAS NECESIDADES DE LAS UNIDADES MEDICAS: GRAFICA DE ALTA RESOLUCION REGISTRO ELECTROCARDIOGRAFICO MULTICANAL EN TIEMPO REAL. CON ALGORITMOS PARA DETECCION DE ARRITMIAS Y MEDICION AUTOMATICA DEL SEGMENTO ST CALCULO AUTOMATICO DE LA FRECUENCIA CARDIACA MAXIMA Y EL CONSUMO DE OXIGENO ESPERADO DE ACUERDO A LAS CARACTERISTICAS DEL PACIENTE. CON UN SISTEMA DE COMPUTO CON MONITOR DE COLOR DE ALTA RESOLUCION REGISTRADOR TECLADO UNIDAD DE DISCOS PUERTO SERIE DE COMUNICACION Y VEHICULO DE TRANSPORTE.",
          "description": "SISTEMA DE MONITORIZACIÓN FISIOLÓGICA EN PRUEBA DE ESFUERZO",
          "requested_quantity": "1",
          "minimum_quantity": "1",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "51",
          "cucop_code": "53101-0879",
          "specific_item_code": "53101",
          "cucop_description": "TORRE DE ENDOSCOPIA",
          "description": "TORRE PARA ENDOSCOPIA DE VIDEO CON ACCESORIOS.",
          "requested_quantity": "2",
          "minimum_quantity": "2",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "52",
          "cucop_code": "53101-0868",
          "specific_item_code": "53101",
          "cucop_description": "TORRE DE ENDOUROLOGIA",
          "description": "TORRE DE ENDOUROLOGÍA CON ACCESORIOS.",
          "requested_quantity": "2",
          "minimum_quantity": "2",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "53",
          "cucop_code": "53101-1842",
          "specific_item_code": "53101",
          "cucop_description": "531.924.0031 ULTRASONOGRAFO. EQUIPO DE ULTRASONIDO CON FINES DIAGNOSTICOS APLICABLE EN PACIENTES ADULTOS Y PEDIATRICOS. CON LAS SIGUIENTES CARACTERISTICAS SELECCIONABLES DE ACUERDO A LAS NECESIDADES DE LAS UNIDADES MEDICAS: MONITOR CON NIVELES DE GRIS TONOS DE COLOR. MODOS: B M/B M RANGO DINAMICO DEL SISTEMA EN DB. DOPPLER CONTINUO Y PULSADO DOPPLER COLOR. SISTEMA DE MAPEO A COLOR ANGIO POWER DOPPLER. IMAGENES ARMONICAS EN MODO B Y COLOR EN LAS VARIABLES: PENETRACION RESOLUCION O INVERSION DE PULSOS. PROGRAMA DE ECORREALZADORES O MEDIOS DE CONTRASTE. CON MEMORIA DE IMAGEN CUADRO POR CUADRO O CINE LOOP EN COLOR BLANCO Y NEGRO Y CINE ESPECTRAL. TECLADO ALFANUMERICO Y SALIDA DE VIDEO. CONVERTIDOR DE BARRIDO DE CANALES DE PROCESO DIGITAL DESDE LA FORMACION DEL HAZ. SELECCION DE PUNTOS FOCALES. ZOOM. CONTROL DE GANANCIA Y AJUSTE DE LA CURVA.",
          "description": "ULTRASONÓGRAFO - DOPPLER COLOR",
          "requested_quantity": "6",
          "minimum_quantity": "6",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "54",
          "cucop_code": "53101-1842",
          "specific_item_code": "53101",
          "cucop_description": "531.924.0031 ULTRASONOGRAFO. EQUIPO DE ULTRASONIDO CON FINES DIAGNOSTICOS APLICABLE EN PACIENTES ADULTOS Y PEDIATRICOS. CON LAS SIGUIENTES CARACTERISTICAS SELECCIONABLES DE ACUERDO A LAS NECESIDADES DE LAS UNIDADES MEDICAS: MONITOR CON NIVELES DE GRIS TONOS DE COLOR. MODOS: B M/B M RANGO DINAMICO DEL SISTEMA EN DB. DOPPLER CONTINUO Y PULSADO DOPPLER COLOR. SISTEMA DE MAPEO A COLOR ANGIO POWER DOPPLER. IMAGENES ARMONICAS EN MODO B Y COLOR EN LAS VARIABLES: PENETRACION RESOLUCION O INVERSION DE PULSOS. PROGRAMA DE ECORREALZADORES O MEDIOS DE CONTRASTE. CON MEMORIA DE IMAGEN CUADRO POR CUADRO O CINE LOOP EN COLOR BLANCO Y NEGRO Y CINE ESPECTRAL. TECLADO ALFANUMERICO Y SALIDA DE VIDEO. CONVERTIDOR DE BARRIDO DE CANALES DE PROCESO DIGITAL DESDE LA FORMACION DEL HAZ. SELECCION DE PUNTOS FOCALES. ZOOM. CONTROL DE GANANCIA Y AJUSTE DE LA CURVA.",
          "description": "ULTRASONÓGRAFO - BÁSICO",
          "requested_quantity": "2",
          "minimum_quantity": "2",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "55",
          "cucop_code": "53101-1327",
          "specific_item_code": "53101",
          "cucop_description": "531.053.0364 ANESTESIA BASICA UNIDAD DE. UNIDAD DE ANESTESIA GENERAL PARA ADMINISTRACION DE OXIGENO OXIDO NITROSO OTROS GASES MEDICINALES Y AGENTES ANESTESICOS. GABINETE: CON LAS SIGUIENTES CARACTERISTICAS: UNO O DOS VAPORIZADORES CON SISTEMA DE EXCLUSION. VENTILADOR INTERCONSTRUIDO O INTEGRADO. CON AL MENOS 3 CONTACTOS ELECTRICOS. YUGOS PARA CILINDROS O2 Y N2O. AL MENOS UN CAJON. MESA DE TRABAJO. REPISA PARA MONITOR. CUATRO RUEDAS DOS CON FRENO. INDICADORES O MANOMETROS INTERCONSTRUIDOS DE PRESION PARA SUMINISTRO DE TOMA MURAL Y DE CILINDROS (2 GASES). CODIFICADOS DE ACUERDO AL CODIGO AMERICANO DE COLORES: O2-VERDE N2O-AZUL AIRE-AMARILLO. BATERIA DE RESPALDO INTERCONSTRUIDA O NO-BREAK GRADO MEDICO CON CAPACIDAD PARA 60 MINUTOS O MAYOR. SUMINISTRO DE GASES: FLUJOMETROS CODIFICADOS DE ACUERDO AL CODIGO AMERICANO DE COLORES: PARA O2 Y N2O NEUMATICOS DOBLES Y PARA AIRE NEUMATICO SENCILLO O DOBLE. CON ILUMINACION PARA EL AREA DE TRABAJO. GUARDA HIPOXICA DE 23% O MAS. FLUSH O SUMINISTRO DE OXIGENO DIRECTO. CIRCUITO DE PACIENTE: UNO O DOS CANISTER REUSABLE Y ESTERILIZABLE EN AUTOCLAVE CON CAPACIDAD TOTAL DE 800 G. O MAYOR. MONTAJE DE CIRCUITO DE REINHALACION PARCIAL (DIRECTO O ADAPTADOR) QUE PERMITA VENTILACION MECANICA Y MANUAL. SISTEMA DE EVACUACION ACTIVO O PASIVO. TODOS LOS ELEMENTOS EN CONTACTO CON EL GAS ESPIRADO DEL PACIENTE DEBERAN SER ESTERILIZABLES EN AUTOCLAVE. VALVULA AJUSTABLE DE PRESION (APL). VALVULA DE SOBREPRESION. VALVULA CONMUTADORA BOLSA-VENTILADOR. RESERVORIO DE POLVO Y AGUA. SOPORTE PARA LA BOLSA DE REINHALACION. VENTILADOR MICROPROCESADO E INTEGRADO: MODOS DE VENTILACION: CONTROLADO POR VOLUMEN. CONTROLADO POR PRESION. CONMUTACION A VENTILACION MANUAL. CONTROL PARA AJUSTES DE VOLUMEN QUE CUBRA EL RANGO DE 50 ML O MENOR A 1400 ML O MAYOR. CONTROL DE FRECUENCIA RESPIRATORIA QUE CUBRA COMO MINIMO EL RANGO DE 6 A 60 RESPIRACIONES POR MINUTO. CONTROL Y AJUSTE DEL PEEP (NO VALVULA EXTERNA). CONTROL PARA AJUSTES DE RELACION I:E Y RELACION I:E INVERSA. CONTROL PARA AJUSTES DE PRESION INSPIRATORIA QUE CUBRA COMO MINIMO EL RANGO DE 10 CM H2O A 50 CM H2O. CONTROL PARA AJUSTES DE PRESION LIMITE: AJUSTABLE CUBRIENDO EL RANGO DE 10-70 CM H2O. SISTEMA DE COMPROBACION. COMPENSACIONES: DE VOLUMEN O DESACOPLO DE FLUJO DE GAS FRESCO. PARAMETROS DE VENTILACION MONITORIZADOS Y DESPLEGADOS NUMERICA O GRAFICAMENTE EN PANTALLA DEL VENTILADOR O DEL MONITOR: FIO2: INTERCONSTRUIDO SENSOR O CELDA O TECNOLOGIA PARAMAGNETICA CON CAPACIDAD DE MONITOREO EN MODO MANUAL Y AUTOMATICO. VOLUMEN CORRIENTE. VOLUMEN MINUTO. PRESION MEDIA. PRESION PICO. PEEP. DESPLIEGUE GRAFICO DE PVA (PRESION VIAS AEREAS). FRECUENCIA RESPIRATORIA. SISTEMA DE ALARMAS AUDIBLES Y VISIBLES: DESPLIEGUE EN MAQUINA O EN PANTALLA DEL VENTILADOR O EN EL MONITOR DE SIGNOS VITALES: FIO2 (ALTA Y BAJA). VM (VOLUMEN MINUTO ALTA Y BAJA). PRESION BAJA DE SUMINISTRO DE GAS. FALLA EN EL SUMINISTRO ELECTRICO. PRESION ALTA Y BAJA DE VIAS AEREAS. INDICADOR EN FUENTE DE ALIMENTACION AC O DC. APNEA. VAPORIZADORES: SUMINISTRAR UNO O DOS VAPORIZADORES A ELECCION DEL USUARIO CON SISTEMA DE EXCLUSION DE USO SIMULTANEO PARA DOS VAPORIZADORES. MONITOR DE SIGNOS VITALES: PRECONFIGURADO O MODULAR. TECLADO SENSIBLE AL TACTO O DE MEMBRANA O PERILLA SELECTORA. PANTALLA TIPO TFT O LCD DE 8Š O MAYOR. POLICROMATICO. CONFIGURABLE POR EL USUARIO. BATERIA DE RESPALDO INTERCONSTRUIDA O NO-BREAK DE GRADO MEDICO CON CAPACIDAD PARA 60 MINUTOS O MAYOR. SOFTWARE EN ESPAÑOL. TENDENCIAS GRAFICAS Y NUMERICAS PARA TODOS LOS PARAMETROS DE DOCE HORAS O MAS. ALARMAS: AUDIOVISUALES PREDETERMINADAS Y CONFIGURABLES POR EL USUARIO PARA TODOS LOS PARAMETROS MONITORIZADOS. POR LO MENOS 3 TRAZOS SIMULTANEOS. PARAMETROS EN MONITOR DE SIGNOS VITALES MONITOREADOS Y DESPLEGADOS EN PANTALLA DEL VENTILADOR O DEL MONITOR: FRECUENCIA CARDIACA ECG EN AL MENOS TRES DERIVACIONES SELECCIONABLES POR EL USUARIO. DESPLIEGUE DE AL MENOS UN CANAL. CAPNOGRAFIA Y CAPNOMETRIA: VALOR DE CO2 INSPIRADO Y ESPIRADO Y DESPLIEGUE DE CURVA DE CO2. SPO",
          "description": "UNIDAD DE ANESTESIA BÁSICA.",
          "requested_quantity": "2",
          "minimum_quantity": "2",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "56",
          "cucop_code": "53101-1326",
          "specific_item_code": "53101",
          "cucop_description": "531.053.0356 ANESTESIA DE ALTA ESPECIALIDAD UNIDAD DE. UNIDAD DE ANESTESIA GENERAL COMPLETAMENTE INTEGRADO PARA ADMINISTRACION DE OXIGENO OXIDO NITROSO OTROS GASES MEDICINALES Y AGENTES ANESTESICOS. CARACTERISTICAS GENERALES: GABINETE: CON LAS SIGUIENTES CARACTERISTICAS SELECCIONABLES DE ACUERDO A NECESIDADES DE LAS UNIDADES MEDICAS: DOS VAPORIZADORES CON SISTEMA DE EXCLUSION. VENTILADOR INTERCONSTRUIDO. MINIMO TRES CONTACTOS ELECTRICOS. YUGOS O REDUCTORES PARA CILINDROS O2 Y N2O. CAJONES AL MENOS UNO. MESA DE TRABAJO. REPISA PARA MONITOR. CUATRO RUEDAS DOS CON FRENO. INDICADORES O MANOMETROS INTERCONSTRUIDOS DE PRESION PARA SUMINISTRO DE TOMA MURAL Y DE CILINDROS (2 GASES). CODIFICADOS DE ACUERDO AL CODIGO AMERICANO DE COLORES (O2-VERDE N2O-AZUL AIRE-AMARILLO). REGULADOR DE SUCCION. BATERIA DE RESPALDO INTERCONSTRUIDA O NO-BREAK GRADO MEDICO CON CAPACIDAD PARA 60 MINUTOS O MAYOR. SUMINISTRO DE GASES: FLUJOMETROS NEUMATICOS DOBLES O ELECTRONICOS O VIRTUALES PARA O2 Y N2O Y AIRE CODIFICADOS DE ACUERDO AL CODIGO AMERICANO DE COLORES (O2 VERDE N2O AZUL AIRE AMARILLO). CON ILUMINACION. MEZCLADOR ELECTRONICO O MECANICO. GUARDA HIPOXICA DENTRO DEL RANGO DE 23% O MAYOR. FLUSH O SUMINISTRO DE OXIGENO DIRECTO. CIRCUITO DE PACIENTE: UNO O DOS CANISTER REUSABLE Y ESTERILIZABLE EN AUTOCLAVE. CON CAPACIDAD TOTAL DE 800 G. O MAYOR. CON UN SISTEMA QUE PERMITA EL CAMBIO DEL CANISTER DURANTE LA VENTILACION MECANICA SIN OCASIONAR FUGAS. MONTAJE DE CIRCUITO DE REINHALACION PARCIAL (DIRECTO O ADAPTADOR). CIRCUITO SEMICERRADO QUE PERMITA VENTILACION MECANICA O MANUAL. SISTEMA DE EVACUACION ACTIVO O PASIVO. TODOS LOS ELEMENTOS EN CONTACTO CON EL GAS ESPIRADO DEL PACIENTE DEBERAN SER ESTERILIZABLES EN AUTOCLAVE. VALVULA AJUSTABLE DE PRESION (APL). VALVULA DE SOBREPRESION. VALVULA CONMUTADORA BOLSA-VENTILADOR. RESERVORIO DE POLVO Y AGUA. SOPORTE PARA LA BOLSA DE REINHALACION. VENTILADOR MICROPROCESADO E INTEGRADO: MODOS DE VENTILACION: CONTROLADO POR VOLUMEN. CONTROLADO POR PRESION. CONMUTACION A VENTILACION MANUAL. SIMV (DISPARO POR FLUJO). PRESION SOPORTE. CONTROL PARA AJUSTES DE VOLUMEN: QUE CUBRA EL RANGO DE 20 A 1400 ML O MAYOR. CONTROL DE FRECUENCIA RESPIRATORIA: QUE CUBRA COMO MINIMO EL RANGO DE 4 A 80 RESPIRACIONES POR MINUTO. CONTROL PARA AJUSTES DE PEEP ELECTRONICO. CONTROL PARA AJUSTES DE RELACION I:E Y RELACION I:E INVERSA. CONTROL PARA AJUSTES DE PRESION INSPIRATORIA: QUE CUBRA COMO MINIMO EL RANGO DE 10 A 50 CM H2O. CONTROL PARA AJUSTES DE PRESION LIMITE: QUE CUBRA COMO MINIMO EL RANGO DE 15 A 70 CM H2O. SISTEMA DE COMPROBACION AUTOMATICO. CONTROL PARA AJUSTES DE PAUSA INSPIRATORIA (VARIABLE Y CONTINUA). COMPENSACIONES: DISTENSIBILIDAD Y FUGAS DEL CIRCUITO DE VOLUMEN O DESACOPLO DE FLUJO DE GAS FRESCO PARA TODO TIPO DE PACIENTES SIN NECESIDAD DE CAMBIO DE FUELLE O PISTON CONTROL DE FLUJO INSPIRATORIO. PANTALLA A COLOR LCD O TFT DE 8\"\" O MAYOR EN DIAGONAL. VENTILADOR DE LA MISMA MARCA QUE EL SISTEMA DE ANESTESIA. PARAMETROS DE VENTILACION MONITORIZADOS Y DESPLEGADOS NUMERICA O GRAFICAMENTE EN PANTALLA DEL VENTILADOR O DEL MONITOR: FIO2: INTERCONSTRUIDO INCLUIR SENSOR O CELDA CON CAPACIDAD DE MONITOREO EN MODO MANUAL Y AUTOMATICO VOLUMEN CORRIENTE-INSPIRADO Y ESPIRADO. VOLUMEN MINUTO INSPIRADO Y ESPIRADO. PRESION MEDIA. PRESION PICO. PEEP. DESPLIEGUE GRAFICO DE LAS CURVAS: PVA FLUJO LAZOS. (PRESION/VOLUMEN FLUJO/VOLUMEN) Y DE AGENTES ANESTESICOS FRECUENCIA RESPIRATORIA. CONCENTRACION INSPIRADA Y ESPIRADA DE TRES AGENTES ANESTESICOS Y OXIDO NITROSO PRESION PLATEAU O MESETA. AGENTES ANESTESICOS: IDENTIFICACION AUTOMATICA DE AGENTES ANESTESICOS Y DETECCION DE MEZCLAS CON DESPLIEGUE DE LA CONCENTRACION INDIVIDUAL DE CADA UNO DE LOS AGENTES. COMPLIANZA Y RESISTENCIA PULMONAR MEDIDAS RESPIRACION A RESPIRACION DEL PACIENTE Y TENDENCIAS DE COMPLIANZA. CONCENTRACION DE O2 INSPIRADO Y ESPIRADO DESPLIEGUE NUMERICO Y DE CURVA. MAC Y TENDENCIAS DE MAC. ALMACENAMIENTO DE LAZOS (CURVAS DE REFERENCIA). ALARMAS CON DESPLIEGUE EN MAQUINA O EN PANTALLA DEL",
          "description": "UNIDAD DE ANESTESIA DE ALTA ESPECIALIDAD.",
          "requested_quantity": "8",
          "minimum_quantity": "8",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "57",
          "cucop_code": "53101-1328",
          "specific_item_code": "53101",
          "cucop_description": "531.053.0372 ANESTESIA INTERMEDIA UNIDAD DE. UNIDAD DE ANESTESIA GENERAL PARA ADMINISTRACION DE OXIGENO OXIDO NITROSO OTROS GASES MEDICINALES Y AGENTES ANESTESICOS. CARACTERISTICAS GENERALES: GABINETE: CON LAS SIGUIENTES CARACTERISTICAS SELECCIONABLES DE ACUERDO A NECESIDADES DE LAS UNIDADES MEDICAS: DOS VAPORIZADORES CON SISTEMA DE EXCLUSION. VENTILADOR INTERCONSTRUIDO O INTEGRADO. CONTACTOS ELECTRICOS MINIMO 3 YUGOS PARA CILINDROS O2 Y N2O. CAJONES AL MENOS UNO. MESA DE TRABAJO. REPISA PARA MONITOR. CUATRO RUEDAS DOS CON FRENO. INDICADORES O MANOMETROS INTERCONSTRUIDOS DE PRESION PARA SUMINISTRO DE TOMA MURAL Y DE CILINDROS (2 GASES). CODIFICADOS DE ACUERDO AL CODIGO AMERICANO DE COLORES (O2-VERDE N2O-AZUL AIRE-AMARILLO). BATERIA DE RESPALDO INTERCONSTRUIDA O NO-BREAK GRADO MEDICO CON CAPACIDAD PARA 60 MINUTOS O MAYOR. SUMINISTRO DE GASES: FLUJOMETROS CODIFICADOS DE ACUERDO AL CODIGO AMERICANO DE COLORES (O2 VERDE N2O AZUL AIRE AMARILLO).PARA O2 N2O Y AIRE NEUMATICOS DOBLES O ELECTRONICOS. CON ILUMINACION EN FLUJOMETROS NEUMATICOS O DESPLIEGUE DIGITAL ELECTROLUMINISCENTE. GUARDA HIPOXICA DENTRO DEL RANGO DE 23% O MAYOR. FLUSH O SUMINISTRO DE OXIGENO DIRECTO. CIRCUITO DE PACIENTE: UNO O DOS CANISTER REUSABLE Y ESTERILIZABLE EN AUTOCLAVE. CON CAPACIDAD TOTAL DE 800 G. O MAYOR. MONTAJE DE CIRCUITO DE REINHALACION PARCIAL (DIRECTO O ADAPTADOR) QUE PERMITA VENTILACION MECANICA O MANUAL. SISTEMA DE EVACUACION ACTIVO O PASIVO. TODOS LOS ELEMENTOS EN CONTACTO CON EL GAS ESPIRADO DEL PACIENTE DEBERAN SER ESTERILIZABLES EN AUTOCLAVE. VALVULA AJUSTABLE DE PRESION (APL). VALVULA DE SOBREPRESION. CONMUTACION DE BOLSA A VENTILADOR. RESERVORIO DE POLVO Y AGUA. SOPORTE PARA LA BOLSA DE REINHALACION. VENTILADOR MICROPROCESADO E INTEGRADO: MODOS DE VENTILACION: CONTROLADO POR VOLUMEN. CONTROLADO POR PRESION. CONMUTACION A VENTILACION MANUAL. SIMV (DISPARADO POR PRESION O POR FLUJO). CAPACIDAD PARA INTEGRAR VENTILACION POR PRESION-SOPORTE. CONTROL PARA AJUSTES DE VOLUMEN QUE CUBRA EL RANGO DE 20 A 1400 ML O MAYOR. CONTROL DE FRECUENCIA RESPIRATORIA QUE CUBRA COMO MINIMO EL RANGO DE 4 A 60 RESPIRACIONES POR MINUTO. CONTROL PARA AJUSTES DE PEEP ELECTRONICO. CONTROL PARA AJUSTES DE RELACION I:E Y RELACION I:E INVERSA. CONTROL PARA AJUSTES DE PRESION INSPIRATORIA QUE CUBRA COMO MINIMO EL RANGO DE 10 CM H2O A 50 CM H2O. CONTROL PARA AJUSTES DE PRESION LIMITE QUE CUBRA COMO MINIMO EL RANGO DE 15-70 CM H2O. SISTEMA DE COMPROBACION AUTOMATICO. CONTROL PARA AJUSTES DE PAUSA INSPIRATORIA VARIABLE Y CONTINUA. COMPENSACION: DISTENSIBILIDAD Y FUGAS DE CIRCUITO. DE VOLUMEN O DESACOPLO DE VOLUMEN CORRIENTE DEL GAS FRESCO. PARA TODO TIPO DE PACIENTES SIN NECESIDAD DE CAMBIO DE FUELLE O PISTON. VENTILADOR DE LA MISMA MARCA QUE EL SISTEMA DE ANESTESIA. PARAMETROS DE VENTILACION MONITORIZADOS Y DESPLEGADOS NUMERICA O GRAFICAMENTE EN PANTALLA DEL VENTILADOR O DEL MONITOR: FIO2. INTERCONSTRUIDO. SENSOR O CELDA O TECNOLOGIA PARAMAGNETICA. CON CAPACIDAD DE MONITOREO EN MODO MANUAL Y AUTOMATICO. VOLUMEN CORRIENTE. VOLUMEN MINUTO. PRESION MEDIA. PRESION PICO. PEEP. DESPLIEGUE GRAFICO DE PVA (PRESION VIAS AEREAS). FRECUENCIA RESPIRATORIA. SISTEMA DE ALARMAS AUDIBLES Y VISIBLES: PRIORIZADAS EN TRES NIVELES CON DESPLIEGUE DE MENSAJES DE LAS MISMAS EN ESPAÑOL. DESPLIEGUE EN MAQUINA O EN PANTALLA DEL VENTILADOR O EN EL MONITOR DE SIGNOS VITALES: FIO2 (ALTA Y BAJA). VM (VOLUMEN MINUTO ALTA Y BAJA). PRESION BAJA DE SUMINISTRO DE O2. FALLA EN EL SUMINISTRO ELECTRICO. PRESION ALTA Y BAJA DE VIAS AEREAS. INDICADOR EN FUENTE DE ALIMENTACION AC O DC. APNEA. SENSOR DE OXIGENO: FALLA O CAMBIO DEL SENSOR DE O2. FALLA EN LA MEDICION DE O2 CON TECNICA PARAMAGNETICA. FALLA EN SENSOR DE PRESION O FLUJO. ALARMA DE FUGA. VAPORIZADORES: DOS VAPORIZADORES A ELECCION DEL USUARIO CON SISTEMA DE EXCLUSION DE USO SIMULTANEO PARA DOS VAPORIZADORES. MONITOR DE SIGNOS VITALES: PRECONFIGURADO O MODULAR. PANTALLA SENSIBLE AL TACTO O TECLADO SENSIBLE AL TACTO O DE MEMBRANA O DE PERILLA SELECTORA. PAN",
          "description": "UNIDAD DE ANESTESIA INTERMEDIA.",
          "requested_quantity": "11",
          "minimum_quantity": "11",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "58",
          "cucop_code": "53101-0325",
          "specific_item_code": "53101",
          "cucop_description": "UNIDAD CRIOCIRUGIA (EQUIPO MEDICO QUIRURGICO)",
          "description": "UNIDAD DE CRIOCIRUGÍA GINECOLÓGICA",
          "requested_quantity": "1",
          "minimum_quantity": "1",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "59",
          "cucop_code": "53101-1500",
          "specific_item_code": "53101",
          "cucop_description": "531.328.0181 UNIDAD DE ELECTROCIRUGIA DE USO GENERAL. ELECTROCOAGULADOR QUIRURGICO PARA HEMOSTASIA Y CORTE POR MEDIO DE ALTA FRECUENCIA. CON LAS SIGUIENTES CARACTERISTICAS DE ACUERDO A LAS NECESIDADES DE LAS UNIDADES MEDICAS: COAGULACION Y CORTE. RANGO DE POTENCIA MAXIMA EN EL CORTE. EFECTOS DE COAGULACION Y POTENCIA MAXIMA DE SALIDA EN COAGULACION. CORTE Y COAGULACION CONTROLADOS POR MICROPROCESADOR. INDICADORES DIGITALES MONO Y BIPOLAR. ALARMAS. INDICADORES AUDIBLES Y VISIBLES. SALIDAS MONOPOLARES PARA CORTAR Y COAGULAR. PROGRAMAS DE AUTODIAGNOSTICO Y REPORTE DE ERRORES.",
          "description": "UNIDAD DE ELECTROCIRUGÍA - BIPOLAR.",
          "requested_quantity": "21",
          "minimum_quantity": "21",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "60",
          "cucop_code": "53101-1500",
          "specific_item_code": "53101",
          "cucop_description": "531.328.0181 UNIDAD DE ELECTROCIRUGIA DE USO GENERAL. ELECTROCOAGULADOR QUIRURGICO PARA HEMOSTASIA Y CORTE POR MEDIO DE ALTA FRECUENCIA. CON LAS SIGUIENTES CARACTERISTICAS DE ACUERDO A LAS NECESIDADES DE LAS UNIDADES MEDICAS: COAGULACION Y CORTE. RANGO DE POTENCIA MAXIMA EN EL CORTE. EFECTOS DE COAGULACION Y POTENCIA MAXIMA DE SALIDA EN COAGULACION. CORTE Y COAGULACION CONTROLADOS POR MICROPROCESADOR. INDICADORES DIGITALES MONO Y BIPOLAR. ALARMAS. INDICADORES AUDIBLES Y VISIBLES. SALIDAS MONOPOLARES PARA CORTAR Y COAGULAR. PROGRAMAS DE AUTODIAGNOSTICO Y REPORTE DE ERRORES.",
          "description": "UNIDAD DE ELECTROCIRUGÍA DE USO GENERAL - GINECOLÓGICA",
          "requested_quantity": "1",
          "minimum_quantity": "1",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "61",
          "cucop_code": "53101-1742",
          "specific_item_code": "53101",
          "cucop_description": "531.661.0079 UNIDAD DE FACOEMULSION. APARATO PARA EXTRACCION DE CATARATA POR FACOFRAGMENTACION Y VITRECTOMIA ANTERIOR. UNIDAD QUE CONSTA DE: PIEZA DE MANO DE ULTRASONIDO PARA FACOEMULSIFICACION; PIEZA DE MANO I/A DE PUNTA INTERCAMBIABLE; PUNTA CON PUERTO DE 0.3 MM CURVA DE I/A; PUNTA CON PUERTO DE 0.3 MM A 90 ° DE I/A. PEDAL DE TECNOLOGIA AVANZADA. CABEZA DE OCUTOMO DE VITRECTOMIA ANTERIOR. PUNTA DE FACOEMULSIFICACION DE 30 °. JUEGO DE TUBERIA.",
          "description": "UNIDAD DE FACOEMULSIÓN CON VITRECTOR",
          "requested_quantity": "1",
          "minimum_quantity": "1",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "62",
          "cucop_code": "53101-1776",
          "specific_item_code": "53101",
          "cucop_description": "531.791.0066 RESONANCIA MAGNETICA DE 1.5 TESLAS UNIDAD DE IMAGEN POR. EQUIPO PARA OBTENER IMAGENES DIAGNOSTICAS DE CUERPO ENTERO MEDIANTE EL USO DE RADIOFRECUENCIAS Y CAMPOS MAGNETICOS. CON CAPACIDAD DE 1.5 TESLAS. MAGNETO SUPER CONDUCTOR. GRADIENTE POR EJE DE 30 MILITESLAS/MTS COMO MINIMO Y UN SLEW RATE 120 COMO MINIMO. CON METODO O TECNICA DE REDUCCION DE TIEMPO DE ADQUISICION O INCREMENTO DE LA VELOCIDAD DE ADQUISICION. SINCRONIZACION DE LA IMAGEN CON LA RESPIRACION Y ECG O DE MEDICIONES FISIOLOGICAS. TECNOLOGIA DE ADQUISICION O SISTEMA DE RF O TECNOLOGIA DE RF DE AL MENOS 8 CANALES. ESTACION DE ADQUISICION: MONITOR DE PANTALLA PLANA O LCD A COLOR DE 18 Š O MAYOR MATRIZ DE DESPLIEGUE DE 1024 X 1024 O MAYOR. QUEMADOR DE CD O DVD. DICOM PRINT QUERY/RETRIEVE STORAGE Y WORKLIST. FUNCIONES PARA RECONSTRUCCION. UPS PARA EL EQUIPO DE COMPUTO. PROGRAMAS: PAQUETE DE SPIN ECHO. PAQUETE DE RECUPERACION INVERSION: INVERSION RECOVERY. TECNICA DE DIFERENCIACION BASADA EN AGUA O GRASA O RECUPERACION POR SATURACION O TECNICA DE SATURACION GRASA. FAST SPIN ECHO O TURBO SPIN ECHO. PAQUETE PARA ANGIO RESONANCIA CON TIME OF FLIGHT (TOF) O INFLOW. MAGNETIZACION TRANSFER (MTC). PAQUETE DE CINE FLAIR O DARK FLUID. DIFUSION. PERFUSION. PROGRAMA DE REALCE DE CONTRASTE O CONSTRAST ENHANCEMENT. PROGRAMA PARA ANGIOGRAFIA PERIFERICA O VASCULAR PERIFERICA. PROGRAMA DE CORRECCION DE MOVIMIENTO. BOBINAS: SERAN DETERMINADAS O ELEGIDAS DE ACUERDO A LAS NECESIDADES OPERATIVAS DE LAS UNIDADES MEDICAS. MULTICANAL PARA COLUMNA CERVICAL - TORACICA - LUMBAR O CTL O COLUMNA COMPLETA. MULTICANAL DE CUERPO. MULTICANAL PARA CARDIOLOGIA. DE PROPOSITO GENERAL O FLEXIBLE O EXTREMIDADES. DE 8 CANALES PARA CABEZA. MULTICANAL PARA RODILLA. MULTICANAL PARA HOMBRO. MULTICANAL PARA MAMA. ENDOCAVITARIA O PROSTATA. MULTICANAL PARA NEUROVASCULAR O NV. JUEGO DE SUJETADORES AJUSTABLES O DE DIFERENTES TAMAÑOS. JAULA DE FARADAY O APANTALLAMIENTO MAGNETICO. SISTEMA DE ENFRIAMIENTO.",
          "description": "UNIDAD DE IMAGEN POR RESONANCIA MAGNÉTICA DE 1.5 TESLAS - CON EQUIPO Y MOBILIARIO ANTIMAGNÉTICO",
          "requested_quantity": "1",
          "minimum_quantity": "1",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "63",
          "cucop_code": "53101-1782",
          "specific_item_code": "53101",
          "cucop_description": "531.806.0042 UNIDAD DE SECADO PARA EQUIPO DE INHALOTERAPIA. EQUIPO ELECTROHIDRAULICO FIJO PARA SECAR TUBOS. Y ACCESORIOS DEL EQUIPO QUE SE MANEJA EN INHALOTERAPIA Y ANESTESIA EL CUAL TRABAJA EN BASE A FLUJO DE AIRE LAMINAR Y AIRE CALIENTE. CONTROLADO POR MICROPROCESADOR CON MODULO DE SECADO INTEGRADO POR DOS CABINAS: UNA PARA COLOCAR AL MENOS DOS CHAROLAS CON RIELES A DIFERENTE ALTURA UNA CON SUJETADORES PARA COLGAR TUBOS. PUERTA TRANSPARENTE QUE PERMITA OBSERVAR EL MATERIAL EN PROCESO. INDICADOR (LED) DE APAGADO/ENCENDIDO. ENTRADA DE AIRE PREFILTRADO EN LA PARTE FRONTAL SUPERIOR PARA PARTICULAS GRANDES. CONTROL DE TEMPERATURA Y TIEMPO DE SECADO. SISTEMA DE RECIRCULACION DE AIRE CALIENTE. CHAROLAS DE DIMENSIONES COMPATIBLES CON LAS MEDIDAS DE LA CABINA PARA COLOCACION DE MATERIAL. DIMENSIONES: 220 CM DE ALTURA 120 CM ANCHO Y 52 CM DE PROFUNDIDAD CON +/- 10% DE TOLERANCIA EN LAS TRES MEDIDAS.",
          "description": "UNIDAD DE SECADO PARA EQUIPO DE INHALOTERAPIA",
          "requested_quantity": "1",
          "minimum_quantity": "1",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "64",
          "cucop_code": "53101-1765",
          "specific_item_code": "53101",
          "cucop_description": "531.772.0265 REFRACTOR Y QUERATOMETRO AUTOMATICO.. APARATO QUE REALIZA AUTORREFRACCION Y QUERATOMETRIA EN DIFERENTES TIPOS DE PACIENTES (AUN CON CATARATA O CON LENTE INTRAOCULAR). AUTORREFRACTOR Y QUERATOMETRO CON PANEL DE CONTROL A 90 O 180 GRADOS CON ALINEAMIENTO AUTOMATICO CON RANGOS DE ESFERA DE -17D A +20D EN PASOS DE 0.12D Y 0.25D RANGO DEL CILINDRO DE -7D A +7D CON PASOS DE 0.12D A 0.25D RANGO DEL EJE DE 0 A 180 ° EN PASOS DE 1 GRADO. LINEAS DE AGUDEZA DE 20 / 15 A 20 / 400 DISTANCIA AL VERTICE DE 0.0 10.5 12.0 13.5 16.5 MM. RANGOS DE QUERATOMETRIA DE 30.00D A 60.00D EN PASOS DE 0.12D. EJE DE 0 A 180 ° EN PASOS DE 1 GRADO UNA PANTALLA DE 5 \"\". CRT INTERFASE RS-232C Y VIDEO. ELECTRICO DE 90-264 VAC. CARTILLAS STARBUST SNELLEN ROJO-VERDE VISION CERCANA BAJO CONTRASTE Y PARA NIÑOS. IMPRESION DE REFRACCION OBJETIVA SUBJETIVA VISION CERCANA AGUDEZA VISUAL BAJO CONTRASTE QUERATOMETRIA DISTANCIA AL VERTICE Y DISTANCIA INTERPUPILAR. MESA DE ALTURA ELECTRICA.",
          "description": "UNIDAD OFTALMOLÓGICA CON REFRACTOR Y QUERATOMETRO",
          "requested_quantity": "2",
          "minimum_quantity": "2",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "65",
          "cucop_code": "53101-1746",
          "specific_item_code": "53101",
          "cucop_description": "531.670.0060 UNIDAD OTORRINOLARINGOLOGICA. UNIDAD FIJA INTEGRADA POR ADITAMENTOS NECESARIOS PARA EL DIAGNOSTICO Y TRATAMIENTO DE PROBLEMAS OTORRINOLARINGOLOGICOS. UNIDAD INTEGRADA POR CONSOLA PARA FUENTE DE ENERGIA Y CONTROL DE INSTRUMENTOS QUE CONSTA DE: ATOMIZADOR DE POLVOS. ATOMIZADOR PARA SOLUCION ACUOSA. ATOMIZADOR PARA SOLUCION ACEITOSA. UNIDAD DE SUCCION. SOPORTE PARA EQUIPO MICROCAUTERIZADOR O CAUTERIZADOR. TABLERO INTEGRADO A LA CONSOLA PARA INSTRUMENTOS. SISTEMA DE CALENTAMIENTO PARA SOLUCIONES POR MEDIOS ELECTRICOS. VALVULA PARA CONTROL DEL SUMINISTRO DE AGUA. NEGATOSCOPIO INTEGRADO A LA CONSOLA. UNIDAD DE TRANSILUMINACION INTEGRADA A LA CONSOLA. CON DISPOSITIVO O PISTOLA DE IRRIGACION INTEGRADO A LA UNIDAD. SILLON CON AJUSTE VERTICAL POR ELECTROMOTOR Y CONTROL DE PEDAL ROTACION LIBRE DE CUANDO MENOS 330 GRADOS SIN PASOS SOPORTE AJUSTABLE PARA CABEZA DESCANSAPIES AJUSTABLE DESCANSABRAZOS ABATIBLE RESPALDO RECLINABLE DESDE 90 GRADOS HASTA POSICION HORIZONTAL ROTACION DEL ASIENTO A IZQUIERDA Y DERECHA HASTA 330 GRADOS.",
          "description": "UNIDAD OTORRINOLARINGOLÓGICA",
          "requested_quantity": "2",
          "minimum_quantity": "2",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "66",
          "cucop_code": "53101-1447",
          "specific_item_code": "53101",
          "cucop_description": "531.254.0155 TOMOGRAFIA COMPUTARIZADA MULTICORTES DE 64 CORTES UNIDAD PARA. EQUIPO DE RAYOS X PARA REALIZAR ESTUDIOS TOMOGRAFICOS DE 64 CORTES POR GIRO O ROTACION DE DIFERENTES PARTES DEL CUERPO CON FINES DIAGNOSTICOS. CON UN TIEMPO DE EXPLORACION O RASTREO DE 0.4 SEG O MENOR EN UN GIRO O ROTACION DE 360 °. RESOLUCION TEMPORAL. GANTRY: ANGULACION DE ±30 GRADOS O MAYOR Y APERTURA DE 70 CENTIMETROS O MAYOR. MESA DE PACIENTE: CAPACIDAD DE CARGA DE LA MESA DE 180 KILOGRAMOS O MAYOR. SISTEMA DE POSICIONAMIENTO EN 2 EJES (VERTICAL Y HORIZONTAL). ALINEACION EN AL MENOS TRES EJES PARA DEFINIR EL PLANO DE CORTE. SISTEMA DE RAYOS X: TUBO DE RAYOS X CON CAPACIDAD DE ALMACENAMIENTO DE CALOR EN EL ANODO DE 7.5 MHU O MAYOR. CAPACIDAD DE DISIPACION DE CALOR. CON ESPESOR DE CORTE DE 0.625 MM O MENOR POR 64 CORTES EN HELICOIDAL. GENERADOR DE RAYOS X. CAMPO DE RASTREO O FOV DE 50 CM O MAYOR. PROCESAMIENTO DE IMAGENES: RECONSTRUCCION DE IMAGEN DE 16 IMAGENES POR SEGUNDO O MAYOR. RESOLUCION ESPACIAL. MATRIZ DE RECONSTRUCCION. MATRIZ DE DESPLIEGUE DE 1024X1024 O MAYOR. RECONSTRUCCION DE CONJUNTOS DE CORTES TRIDIMENSIONALES O 3D. RECONSTRUCCION DE VOLUMENES Y SUPERFICIES QUE PERMITA ROTACION ZOOM Y SEGMENTACION DE ORGANOS. CONSOLA DEL OPERADOR O ESTACION DE ADQUISICION: DOS MONITORES CON PANTALLA PLANA O LCD A COLOR DE ALTA RESOLUCION MATRIZ DE DESPLIEGUE DE 1024 X 1024 O MAYOR. CAPACIDAD DE ALMACENAJE DE IMAGENES EN DISCO DURO DE 140 GB O MAYOR. CAPACIDAD DE ALMACENAJE EXTERNO DE IMAGENES EN CD O DVD. CON PROGRAMAS PARA APLICACION DIAGNOSTICA: HERRAMIENTAS BASICAS PARA IMAGENES: ZOOM ROTACION IMAGEN ESPECULAR O EN ESPEJO ESCALA DE GRISES DISTANCIAS VOLUMENES. PROGRAMAS ESPECIFICOS PARA: REDUCCION DE DOSIS DE RADIACION PARA PEDIATRIA. MPR (PROYECCION MULTIPLANAR) EN TIEMPO REAL EN POR LO MENOS TRES PLANOS. DICOM PRINT QUERY/RETRIEVE STORAGE Y WORKLIST.",
          "description": "UNIDAD PARA TOMOGRAFÍA COMPUTARIZADA MULTICOLORES",
          "requested_quantity": "1",
          "minimum_quantity": "1",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "67",
          "cucop_code": "53101-1447",
          "specific_item_code": "53101",
          "cucop_description": "531.254.0155 TOMOGRAFIA COMPUTARIZADA MULTICORTES DE 64 CORTES UNIDAD PARA. EQUIPO DE RAYOS X PARA REALIZAR ESTUDIOS TOMOGRAFICOS DE 64 CORTES POR GIRO O ROTACION DE DIFERENTES PARTES DEL CUERPO CON FINES DIAGNOSTICOS. CON UN TIEMPO DE EXPLORACION O RASTREO DE 0.4 SEG O MENOR EN UN GIRO O ROTACION DE 360 °. RESOLUCION TEMPORAL. GANTRY: ANGULACION DE ±30 GRADOS O MAYOR Y APERTURA DE 70 CENTIMETROS O MAYOR. MESA DE PACIENTE: CAPACIDAD DE CARGA DE LA MESA DE 180 KILOGRAMOS O MAYOR. SISTEMA DE POSICIONAMIENTO EN 2 EJES (VERTICAL Y HORIZONTAL). ALINEACION EN AL MENOS TRES EJES PARA DEFINIR EL PLANO DE CORTE. SISTEMA DE RAYOS X: TUBO DE RAYOS X CON CAPACIDAD DE ALMACENAMIENTO DE CALOR EN EL ANODO DE 7.5 MHU O MAYOR. CAPACIDAD DE DISIPACION DE CALOR. CON ESPESOR DE CORTE DE 0.625 MM O MENOR POR 64 CORTES EN HELICOIDAL. GENERADOR DE RAYOS X. CAMPO DE RASTREO O FOV DE 50 CM O MAYOR. PROCESAMIENTO DE IMAGENES: RECONSTRUCCION DE IMAGEN DE 16 IMAGENES POR SEGUNDO O MAYOR. RESOLUCION ESPACIAL. MATRIZ DE RECONSTRUCCION. MATRIZ DE DESPLIEGUE DE 1024X1024 O MAYOR. RECONSTRUCCION DE CONJUNTOS DE CORTES TRIDIMENSIONALES O 3D. RECONSTRUCCION DE VOLUMENES Y SUPERFICIES QUE PERMITA ROTACION ZOOM Y SEGMENTACION DE ORGANOS. CONSOLA DEL OPERADOR O ESTACION DE ADQUISICION: DOS MONITORES CON PANTALLA PLANA O LCD A COLOR DE ALTA RESOLUCION MATRIZ DE DESPLIEGUE DE 1024 X 1024 O MAYOR. CAPACIDAD DE ALMACENAJE DE IMAGENES EN DISCO DURO DE 140 GB O MAYOR. CAPACIDAD DE ALMACENAJE EXTERNO DE IMAGENES EN CD O DVD. CON PROGRAMAS PARA APLICACION DIAGNOSTICA: HERRAMIENTAS BASICAS PARA IMAGENES: ZOOM ROTACION IMAGEN ESPECULAR O EN ESPEJO ESCALA DE GRISES DISTANCIAS VOLUMENES. PROGRAMAS ESPECIFICOS PARA: REDUCCION DE DOSIS DE RADIACION PARA PEDIATRIA. MPR (PROYECCION MULTIPLANAR) EN TIEMPO REAL EN POR LO MENOS TRES PLANOS. DICOM PRINT QUERY/RETRIEVE STORAGE Y WORKLIST.",
          "description": "UNIDAD PARA TOMOGRAFÍA COMPUTARIZADA AXIAL",
          "requested_quantity": "1",
          "minimum_quantity": "1",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "68",
          "cucop_code": "53101-1487",
          "specific_item_code": "53101",
          "cucop_description": "531.325.0069 UNIDAD PARA ULTRASONOGRAFIA OFTALMOLOGICA.. EQUIPO AUXILIAR EN EL DIAGNOSTICO DE RETINOPATIAS EN PACIENTES DIABETICOS LESIONES O TUMORES OCULARES. ULTRASONIDO OCULAR TECLADO ALFANUMERICO PANTALLA INTERCONSTRUIDA BLANCO Y NEGRO 64 NIVELES DE GRIS O MAYOR. PORTA-TRANSDUCTORES. FUNCION PARA CALCULO DE LENTES INTRAOCULARES DE ACUERDO A BINKHORST Y HOLLADAY COMO MINIMO. DE 60 ° Y FRECUENCIA DE RASTREO DE 10 HZ MEDICIONES DE DISTANCIA Y AREA. MODOS DE OPERACION. MODO A Y MODO B. TRANSDUCTOR CON FRECUENCIA DE 10 MHZ O MAYOR. INTERVALO MEDIBLE DE 15 MM O MENOR A 39 MM O MAYOR GANANCIA VARIABLE CALCULOS DE: LONGITUD AXIAL Y DEL VITREO PROFUNDIDAD DE CAMARA ANTERIOR ESPESOR DE LENTES EN MODO A. TRANSDUCTOR DE 10 MHZ O MAYOR CON ANGULO DE RASTREO EN MODO B.",
          "description": "UNIDAD PARA ULTRASONOGRAFÍA OFTALMOLÓGICA.",
          "requested_quantity": "1",
          "minimum_quantity": "1",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "69",
          "cucop_code": "53101-1489",
          "specific_item_code": "53101",
          "cucop_description": "531.325.0192 UNIDAD PARA ULTRASONOGRAFIA TRANSOPERATORIA. EQUIPO DE ULTRASONOGRAFIA PARA DIAGNOSTICO DURANTE EL TRANSOPERATORIO ULTRASONOGRAFO COMPACTO DE 47 X 45 X 26 CM CON DOPPLER A COLOR Y TRANSDUCTORES ESTERILIZABLES EN LIQUIDOS CON GAS. INTEGRACION DE VIDEO PIP LO CUAL PERMITE QUE LA IMAGEN DEL ULTRASONIDO SEA MOSTRADA EN EL MONITOR DE VIDEO AL MISMO TIEMPO QUE OTRAS IMAGENES EXTERNAS EN QUIROFANO. UNIDAD DE CONTROL REMOTO DISEÑADA PARA FACIL Y RAPIDA OPERACION DENTRO DE QUIROFANO. LAS TECLAS EN EL CONTROL ESTAN MARCADAS PARA RAPIDO RECONOCIMIENTO DE LAS FUNCIONES A REALIZAR COMO SON FREEZE GANANCIA SIZE COPIA ORIENTACION RANGO COLOR BOX. UN MOUSE INTEGRADO PARA MODOS DE MEDICION Y SELECCION. LAS FUNCIONES DE SET-UP SON SELECCIONADAS DESDE EL KEYBOARD COMPLEMENTADO CONUN INTUITIVO SOFTWARE ON- SCREEN Y OPCIONES DE MENU. MODOS DE EXPLORACION: B B + COLOR FLOW MAPPING (STEERABLE) B + POWER DOPPLER (STEERABLE). RANGO DE FRECUENCIA CENTRAL DE TRANSDUCTORES DE 2.7 A 12.5 MHZ. TRANSDUCTORES LINEAL/CONVEXO DE ARREGLO EN FASE ELECTRONICOS Y DE UN ELEMENTO. CARACTERISTICAS DE IMAGEN DE 530 X 400 PUNTOS. NUMERO DE ESCALAS DE GRISES DE 256 NIVELES. CAPACIDAD DE MEMORIA 1024 X 512 X 8 BITS. PRESENTACION DE ESPEJO ARRIBA/ABAJO IZQUIERDA/DERECHA. FUNCION ZOOM DE 2.3 X 2.3 CM A 25 X 25 CM Y EL NUMERO DE PASOS DEPENDE DEL TRANSDUCTOR EMPLEADO. CARACTERISTICAS: SPLIT SCREEN VERTICAL/HORIZONTAL USER SET-UP INCLUYENDO TRES POR CADA TRANSDUCTOR REVISION DE IMAGENES (DE 1 A 7 SEG./ 25 A 70 IMAGENES DE ULTRASONIDO) DEPENDIENDO DEL TIPO DE TRANSDUCTOR. ESCALA DE IMAGEN LINEAS DE PUNCION. ANOTACIONES DENTRO DE LA IMAGEN: ALFANUMERICAS NIVELES Y COMENTARIOS MARCADORES DE CUERPO IDENTIFICACION DE PACIENTE Y UNIDAD MEDICA. PRESENTACION DE IMAGENES MEDIANTE MULTIFORMATO ELECTRONICO. VIDEOIMPRESORA EN COLOR O BLANCO Y NEGRO. VIDEOCASETERA (SVHS). PUERTO DE SALIDA RS232 PARA CONEXION A SISTEMA DE RED DE ALTA VELOCIDAD. CON OPCION A TRANSDUCTORES: NEUROQUIRURGICO MFI (5 6 6.5 7.5 Y 8 MHZ) LAPAROSCOPICO (5 6.5 Y 7.5 MHZ) INTRAOPERATIVO (5 6.5 Y 7.5 MHZ) PEDIATRICOS (5 7 Y 8 MHZ) Y ENDOLUMINAL (9 Y 12.5 MHZ).",
          "description": "UNIDAD PARA ULTRASONOGRAFÍA TRANSOPERATORIA - DOPPLER COLOR",
          "requested_quantity": "8",
          "minimum_quantity": "8",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "70",
          "cucop_code": "53101-1538",
          "specific_item_code": "53101",
          "cucop_description": "531.341.2537 UNIDAD RADIOLOGICA DIGITAL PARA ESTUDIOS DE TORAX. EQUIPO RADIOGRAFICO PARA LA TOMA DE IMAGENES DIGITALES DE TORAX. SISTEMA DE DETECCION: SISTEMA DETECTOR 2000 X 2000 X 12 BIT O MAYOR QUE PERMITA FORMATOS HASTA 40 X 40 CM O MAYOR DISTANCIA FOCO IMAGEN DE 180 CM O MAYOR. RECORRIDO VERTICAL. ESTACION DE TRABAJO QUE PERMITA LA VISUALIZACION DE LAS IMAGENES ADQUIRIDAS ASI COMO SU ALMACENAMIENTO CON MONITOR DE 21 PULGADAS O MAYOR B/N O COLOR CON RESOLUCION DE 1280 X 1024 PIXELES O MAYOR ALMACENAMIENTO DE 300 O MAS IMAGENES. GENERADOR DE RAYOS X DE ALTA FRECUENCIA POTENCIA NOMINAL DE 50 KW O MAYOR CORRIENTE MAXIMA DE 650 MA KILOVOLTAJE HASTA 140 KV VARIABLE CONTROL AUTOMATICO DE EXPOSICION. TUBO DE RAYOS X: PUNTO FOCAL DE 1.3 MM O MENOR CAPACIDAD CALORIFICA DEL ANODO DE 300 KHU.",
          "description": "UNIDAD RADIOLÓGICA DIGITAL PARA ESTUDIOS DE TÓRAX",
          "requested_quantity": "3",
          "minimum_quantity": "3",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "71",
          "cucop_code": "53101-1532",
          "specific_item_code": "53101",
          "cucop_description": "531.341.2479 UNIDAD RADIOLOGICA PORTATIL. EQUIPO DE RAYOS \"\"X\"\" MOVIL CON LAS SIGUIENTES CARACTERISTICAS APLICABLES SEGUN NECESIDADES DIAGNOSTICAS: GENERADOR DE RAYOS \"\"X\"\" DE ALTA FRECUENCIA O TIPO CONVERTIDOR POTENCIA AJUSTE DE KILOVOLTAJE CORRIENTE TIEMPO DE EXPOSICION AJUSTE DE MAS. CONTROLES E INDICADORES DE PARAMETROS DE EXPOSICION CON DESPLIEGUE EN PANTALLA DIGITAL. TUBO DE RAYOS \"\"X : CON ANODO ROTATORIO CON AL MENOS UN PUNTO FOCAL CON CAPACIDAD TERMICA DE ALMACENAMIENTO DEL ANODO. COLIMADOR MANUAL CON CENTRADOR DE HAZ LUMINOSO. PORTATUBO TIPO TELESCOPICO O CONTRAPESADO: GIRATORIO ALTURA MAXIMA DEL FOCO AL PISO GIRO DEL TUBO. CAJON GUARDACHASISES. RODAMIENTO CON SISTEMA DE FRENADO. PESO. CON O SIN BATERIA RECARGABLE PARA EL DISPARO. MANDIL EMPLOMADO.",
          "description": "UNIDAD RADIOLÓGICA PORTÁTIL - DIGITAL",
          "requested_quantity": "10",
          "minimum_quantity": "10",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "72",
          "cucop_code": "53101-1537",
          "specific_item_code": "53101",
          "cucop_description": "531.341.2529 UNIDAD RADIOLOGICA Y FLUOROSCOPICA CON TELEMANDO Y ARCO EN ŠCŠ CON MESA BASCULABLE. SISTEMA DE RAYOS \"\"X\"\" MULTIPROPOSITO PARA APLICACIONES RADIOGRAFICAS FLUOROSCOPICAS ANGIOGRAFICAS E INTERVENCIONALES. MESA DE RAYOS \"\"X\"\" TELECOMANDADA CON BRAZO TIPO \"\"C\"\" PARA MONTAJE DEL TUBO E INTENSIFICADOR DE IMAGEN CON COBERTURA DE PACIENTE DE AL MENOS 120 CM. CON SISTEMA DE PROTECCION DE CHOQUES. GENERADOR GENERADOR TRIFASICO DE RAYOS \"\"X\"\" DE ALTA FRECUENCIA CONTROLADO MEDIANTE MICROPROCESADORES Y SISTEMA DE PROTECCION DE ERROR CON PROTECCION CONTRA SOBRECARGA DEL TUBO POTENCIA DE 80 KW COMO MINIMO Y AL MENOS 1000 MA DE CORRIENTE MAXIMA TIEMPO DE EXPOSICION DE 2 MS O MENOR CON AJUSTE DE VOLTAJE ENTRE 40 KW O MENOR HASTA 125 KW O MAYOR CONTROL AUTOMATICO DE EXPOSICION CONTROL AUTOMATICO DE BRILLO. CON CONSOLA DE CONTROL DE MANDO CERCANO Y TELEMANDO. TUBO DE RAYOS \"\"X\"\" 9000 R.P.M. COMO MINIMO CON PUNTO FOCAL FINO NO MAYOR A 0.6 MM Y PUNTO FOCAL GRUESO NO MAYOR A 1.2 MM. CON CAPACIDAD DE ACUMULACION DE CALOR EN EL ANODO DE AL MENOS 300 KHU. MESA PACIENTE TELEMANDO BASCULABLE 85°/ -45° SUSPENDIDA DE UN SOLO PUNTO Y CONO PARA COMPRESION MANEJADO A CONTROL REMOTO ALTURA DE LA MESA VARIABLE DESDE 90 CM O MENOR HASTA 120 CM. O MAYOR DESPLAZAMIENTO LATERAL DEL TABLERO DE LA MESA DE AL MENOS + 12.5 CM. Y 20 CM O DESPLAZAMIENTO LATERAL DEL BRAZO EN C DE AL MENOS + 13 CM Y DE - 15 CM. CARACTERISTICAS DEL BRAZO DESPLAZAMIENTO LONGITUDINAL DEL BRAZO C DE AL MENOS 125 CM. CON VELOCIDAD CONTINUAMENTE VARIABLE ROTACION DEL BRAZO EN C DE 90 ° LAO COMO MINIMO HASTA AL MENOS 40 ° RAO ANGULACION CRANEO - CAUDAL DEL BRAZO EN C DE POR LO MENOS ± 30 ° EN POSICION A.P Y P.A. CON VELOCIDAD VARIABLE. INTENSIFICADOR DE IMAGEN DE 35 CM O MAYOR CON AL MENOS 3 CAMPOS 35/25/17 CM O MAYOR Y SISTEMA DE DETECCION DE COLISION INCORPORADO DOS MONITORES DE T.V. CON LAS SIGUIENTES CARACTERISTICAS: ALTA RESOLUCION DE 1049 AJUSTE AUTOMATICO DE BRILLO PANTALLA DE 50 CM O MAYOR CON SUSPENSION AL TECHO. CON SISTEMA DIGITAL DE ADQUISICION DE IMAGENES EN 1024 X 1024 PIXELES Y 10 BITS QUE CUENTE CON: AL MENOS 64 MBYTES DE MEMORIA RAM O EN DISCO ADQUISICION DE 7.5 IMAGENES POR SEGUNDO O MAYOR DISCO OPTICO MAGNETICO CON CAPACIDAD MINIMA DE 600 MB O MAYOR SUSTRACCION DIGITAL EN TIEMPO REAL DESPLIEGUE DE 16 IMAGENES. CONTROL REMOTO PARA SELECCION DE IMAGENES CONSOLA CON TECLADO ALFANUMERICO Y MONITOR DE 53 CM O MAYOR Y 1000 LINEAS O MAYOR CON PROGRAMAS PARA PROCESAMIENTO DE LA IMAGEN QUE AL MENOS PERMITAN EL REALCE DE BORDES ADAPTACION DEL BRILLO RE-ENMASCARAMIENTO CORRECCION EN TIEMPO REAL O FILTRO PARA CORRECCIONES DINAMICAS DE LOS ARTEFACTOS POR MOVIMIENTO ZOOM Y ANOTACION DE TEXTO.",
          "description": "UNIDAD RADIOLÓGICA Y FLUOROSCOPICA DIGITAL CON TELEMANDO",
          "requested_quantity": "1",
          "minimum_quantity": "1",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "73",
          "cucop_code": "53101-1859",
          "specific_item_code": "53101",
          "cucop_description": "531.941.0972 VENTILADOR ADULTO PEDIATRICO. EQUIPO ELECTROMECANICO CONTROLADO POR MICROPROCESADOR DE SOPORTE DE VIDA PARA APOYO VENTILATORIO EN PACIENTES ADULTOS Y PEDIATRICOS QUE TIENEN COMPROMETIDA LA FUNCION RESPIRATORIA. CON PANTALLA A COLOR QUE MUESTRE GRAFICAS DATOS NUMERICOS ALARMAS PRIORIZADAS EN TIEMPO REAL Y LOS DIFERENTES MODOS VENTILATORIOS SELECCIONADOS PARA UN ADECUADO TRATAMIENTO. PANTALLA INTERCONSTRUIDA: TIPO LCD LCD-TFT O TFT O LED. A COLOR. TAMAÑO MINIMO DE 10Š (25 CM) O MAYOR CONFIGURABLE POR EL USUARIO. CARACTERISTICAS GENERALES: MEZCLADOR DE AIRE-OXIGENO INTERNO. MONITOREO FIO2 INTERNO O INTEGRADO. SENSOR DE FLUJO REUSABLE. CON SISTEMA DE COMPENSACION DE FUGAS. HUMIDIFICADOR SERVOCONTROLADO PARA USO CON CALENTADOR DE TUBO SENCILLO O DUAL; CON SENSOR DE TEMPERATURA SENCILLO O DUAL DE SOPORTE AL VENTILADOR. TODO EL SISTEMA EN IDIOMA ESPAÑOL. TECLADO SENSIBLE AL TACTO O DE MEMBRANA; O PERILLA SELECTORA PARA EL AJUSTE DE LOS VALORES DE TODOS LOS PARAMETROS DE CONTROL. CONTROL DE PARAMETROS DE: VOLUMEN CORRIENTE QUE CUBRA EL RANGO DE 50 A 2000 ML. FLUJO INSPIRATORIO O FLUJO ADAPTATIVO QUE CUBRA EL RANGO DE 10 A 140 L/MIN. PRESION INSPIRATORIA QUE CUBRA EL RANGO DE 5 A 60 CMH2O. FRECUENCIA RESPIRATORIA QUE CUBRA EL RANGO DE 1 A 80 RESPIRACIONES POR MINUTO. TIEMPO INSPIRATORIO QUE CUBRA EL RANGO DE 0.3 A 5 SEGUNDOS. FIO2 QUE CUBRA EL RANGO DE 21 A 100 %. PEEP/CPAP QUE CUBRA EL RANGO DE 1 A 35 CMH2O. PRESION SOPORTE (PSV) PRESION ASISTIDA O ASB QUE CUBRA EL RANGO DE 0 A 50 CMH2O. CON OPCION MESETA INSPIRATORIA DE PLATEU O PAUSA INSPIRATORIA. CON OPCION DE PAUSA ESPIRATORIA DE 0 A 2 SEGUNDOS O MAYOR. CON OPCION A RESPIRACION MANUAL. SALIDA PARA NEBULIZADOR O NEBULIZADOR SINCRONICO ULTRASONICO O ELECTRICO. MECANISMO DE DISPARO O TRIGGER POR FLUJO Y/O POR PRESION. SENSIBILIDAD ESPIRATORIA O TERMINACION DE LA FASE INSPIRATORIA. BIAS FLOW FLUJO BASE CONTINUO O CPAP. AJUSTE DE RAMPA DE PRESION RISE TIME RETARDO INSPIRATORIO RAMPA O INCREMENTO DE LA PENDIENTE DE PRESION 100% DE O2 DE 2 MINUTOS O MAYOR. MODOS VENTILATORIOS: VENTILACION ASISTO CONTROLADA Y SIMV CONTROLADA POR VOLUMEN.VENTILACION ASISTO CONTROLADA Y SIMV CONTROLADA POR PRESION. PRESION SOPORTE (PSV) O PRESION ASISTIDA. CPAP O ESPONTANEO CON LINEA DE BASE ELEVADA. RESPALDO EN CASO DE APNEA DE ACUERDO AL MODO VENTILATORIO POR VOLUMEN O PRESION. VENTILACION NO INVASIVA. PARAMETROS MONITORIZADOS: PRESION INSPIRATORIA PICO O MAXIMA. PRESION MEDIA EN VIAS AEREAS. PRESION DE MESETA O PLATEAU. PEEP. FRECUENCIA RESPIRATORIA. VOLUMEN MINUTO. RELACION I:E. VOLUMEN CORRIENTE EXHALADO. FIO2. INDICADOR DE HORAS DE USO. INDICADOR DE BATERIA DE RESPALDO EN USO. CALCULO DE DISTENSIBILIDAD O COMPLIANCE. CALCULO DE LA RESISTENCIA. DESPLIEGUE DE AL MENOS 2 DE LAS 3 CURVAS DE VENTILACION DE FORMA SIMULTANEA: VOLUMEN- TIEMPO; FLUJO-TIEMPO; PRESION-TIEMPO. DESPLIEGUE DE AL MENOS 2 LAZOS O LOOPS. CAPACIDAD DE ALMACENAR EVENTOS RELACIONADOS CON LOS PARAMETROS VENTILATORIOS SELECCIONADOS Y TENDENCIAS AL MENOS DE 24 HORAS. MEDICION DE AUTOPEEP O PEEPTOTAL. ALARMAS: AUDIBLES Y VISUALES AMBAS PRIORIZADAS EN TRES NIVELES. PRESION INSPIRATORIA ALTA Y BAJA. PEEP BAJO O DESCONEXION DEL PACIENTE. APNEA. VOLUMEN MINUTO Y/O CORRIENTE (ALTO Y BAJO). FRECUENCIA RESPIRATORIA ALTA. FIO2 ALTA Y BAJA. BAJA PRESION DEL SUMINISTRO DE GASES. FALTA DE ALIMENTACION ELECTRICA. BATERIA BAJA. VENTILADOR INOPERANTE O FALLA DEL VENTILADOR. SILENCIO DE ALARMA. ACCESORIOS INCLUIDOS: BRAZO SOPORTE PARA CIRCUITO DE PACIENTE. BASE RODABLE PARA EL EQUIPO CON SISTEMA DE FRENO EN AL MENOS DOS RUEDAS. BATERIA DE RESPALDO INTERNA CON DURACION DE 60 MINUTOS DE RESPALDO COMO MINIMO. MANGUERAS PARA SUMINISTRO DE GAS DE ACUERDO AL CODIGO AMERICANO DE COLORES: O2 - VERDE AIRE - AMARILLO; PUDIENDO SE AIRE Y OXIGENO O SOLO OXIGENO SEGUN MARCA Y MODELO. REGULADORES DE PRESION INTEGRADOS PARA EL SUMINISTRO DE GASES. DOS CIRCUITOS DE PACIENTE ADULTO REUSABLES LIBRES DE LATEX (INCLUYE ADAPTADORES CONECTORES Y TRAMPAS DE AGUA) O",
          "description": "VENTILADOR CON ACCESORIOS ADULTO-PEDIÁTRICO-NEONATAL",
          "requested_quantity": "12",
          "minimum_quantity": "12",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "74",
          "cucop_code": "53101-1864",
          "specific_item_code": "53101",
          "cucop_description": "531.941.1048 VENTILADOR ADULTO / PEDIATRICO DE ALTA FRECUENCIA OSCILATORIA. UNIDAD DE CUIDADOS INTENSIVOS PEDIATRICOS HOSPITALIZACION INHALOTERAPIA URGENCIAS. EQUIPO ELECTROMECANICO DE SOPORTE DE VIDA PARA APOYO EN MODO DE VENTILACION DE ALTA FRECUENCIA OSCILATORIA PARA PACIENTES ADULTOS Y PEDIATRICOS DE MAS DE 35 KG DE PESO CON COMPROMISO DE LA FUNCION RESPIRATORIA. CARACTERISTICAS GENERALES: MEZCLADOR DE AIRE-OXIGENO INTERNO O INTERCONSTRUIDO DE LA MISMA MARCA. GENERADOR DE OSCILACION POR PISTON MEMBRANA O SISTEMA NEUMATICO SIN VALVULA. HUMIDIFICADOR SERVOCONTROLADO PARA USO CON CALENTADOR DE RAMA INSPIRATORIA; CON SENSOR DE TEMPERATURA SENCILLO O DUAL Y SOPORTE AL VENTILADOR. PERILLA SELECTORA FISICA O EN PANTALLA TACTIL PARA EL AJUSTE DE LOS VALORES DE TODOS LOS PARAMETROS DE CONTROL. INDICADOR DE HORAS DE USO. CONTROL DE PARAMETROS DE: PRESION MEDIA EN LAS VIAS AEREAS QUE CUBRA EL RANGO DE 5 A 50 CMH2O O MBAR. FRECUENCIA RESPIRATORIA QUE CUBRA EL RANGO DE 5 A 15 HZ. FIO2 QUE CUBRA EL RANGO DE 21 A 100 %. FLUJO BASE QUE CUBRA EL RANGO DE 0 A 50 L/MIN. PORCENTAJE DE TIEMPO INSPIRATORIO QUE CUBRA EL RANGO DE 30 A 50 %. AMPLITUD QUE CUBRA EL RANGO DE 5 A 90 CMH2O O MBAR. CENTRADO MANUAL O AUTOMATICO DE LA AMPLITUD O DEL PISTON. INICIO O PARO DE OSCILACION. MODOS VENTILATORIOS: HFOV. PARAMETROS MONITORIZADOS: PRESION MEDIA EN LAS VIAS AEREAS (CMH2O O MBAR). FRECUENCIA RESPIRATORIA (HZ). PORCENTAJE DE TIEMPO INSPIRATORIO (%). AMPLITUD (CMH2O O MBAR). DESPLAZAMIENTO DEL PISTON EN CASO DE QUE LA TECNOLOGIA LO REQUIERA. MEDIDOR DE TIEMPO TRANSCURRIDO. ALARMAS: AUDIBLES Y VISUALES AMBAS PRIORIZADAS. PRESION MEDIA (ALTA Y BAJA). OSCILADOR DETENIDO. BAJA PRESION DEL SUMINISTRO DE GASES. FALTA DE ALIMENTACION ELECTRICA. BATERIA BAJA. SILENCIO DE ALARMA. ACCESORIOS INCLUIDOS: BRAZO SOPORTE PARA CIRCUITO PACIENTE. BASE RODABLE PARA EL EQUIPO CON SISTEMA DE FRENO EN AL MENOS DOS RUEDAS. MANGUERAS PARA SUMINISTRO DE GAS DE ACUERDO AL CODIGO AMERICANO DE COLORES: O2- VERDE AIRE - AMARILLO. Y CONEXIONES DE ACUERDO A CADA UNIDAD SOLICITANTE AL MOMENTO DE LICITAR. DIEZ CIRCUITOS DE PACIENTE ADULTO / PEDIATRICO DESECHABLES LIBRES DE LATEX (INCLUYE: ADAPTADORES Y CONECTORES; TAPONES DIAFRAGMA TUBOS DE CONEXION Y TRAMPAS DE AGUA EN CASO DE REQUERIRSE). CUATRO CONJUNTOS DE TAPONES Y DIAFRAGMAS EN CASO DE QUE LA TECNOLOGIA ASI LO REQUIERA. CUATRO FUELLES / TRAMPAS DE AGUA EN CASO DE QUE LA TECNOLOGIA ASI LO REQUIERA. CONJUNTO DE TUBOS DE CONEXION EN CASO DE QUE LA TECNOLOGIA ASI LO REQUIERA. DOS CAMARAS DE HUMIDIFICACION REUSABLES O DIEZ CAMARAS DESECHABLES ADULTO/PEDIATRICO EN CASO DE QUE LA TECNOLOGIA ASI LO REQUIERA.",
          "description": "VENTILADOR DE ALTA FRECUENCIA OSCILATORIA CON ACCESORIOS PEDIÁTRICO/NEONATAL CON MODO CONVENCIONAL",
          "requested_quantity": "20",
          "minimum_quantity": "20",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "75",
          "cucop_code": "53101-1858",
          "specific_item_code": "53101",
          "cucop_description": "531.941.0279 VENTILADOR DE TRASLADO PEDIATRICO-ADULTO. EQUIPO ELECTROMECANICO PORTATIL CONTROLADO POR MICROPROCESADOR CON BATERIA INTERNA DE SOPORTE DE VIDA PARA APOYO VENTILATORIO EN PACIENTES PEDIATRICOS Y ADULTOS QUE TIENEN COMPROMETIDA LA FUNCION RESPIRATORIA Y REQUIEREN TRASLADOS INTRA O EXTRA-HOSPITALARIOS EN TODO TIPO DE AMBULANCIAS O EN SITIOS DE EMERGENCIA. CON PANTALLA MONOCROMATICA O A COLOR QUE MUESTRE GRAFICAS DATOS NUMERICOS Y ALARMAS. PESO NO MAYOR DE 7 KG. PANTALLA INTERCONSTRUIDA: TIPO LCD LCD-TFT TFT O LED. A COLOR O MONOCROMATICA. TAMAÑO DE 5.7\"\" O MAYOR. CONFIGURABLE POR EL USUARIO. CARACTERISTICAS GENERALES: MEZCLADOR DE AIRE-OXIGENO INTERNO O INTEGRADO Y DE LA MISMA MARCA. MONITOREO DE FIO2 INTERNO. SENSOR DE FLUJO REUSABLE. COMPENSACION AUTOMATICA DE LA ALTITUD. DURACION DE LA BATERIA DE RESPALDO (EXTERNA Y/O INTERNA) DE 4 HORAS COMO MINIMO. TIEMPO DE RECARGA DE LA BATERIA DE 5 HORAS COMO MAXIMO. ASA Y SOPORTE PARA CAMILLA. TODO EL SISTEMA EN IDIOMA ESPAÑOL. PERILLA SELECTORA PARA EL AJUSTE DE LOS VALORES DE TODOS LOS PARAMETROS DE CONTROL. CONTROL DE PARAMETROS DE: VOLUMEN CORRIENTE QUE CUBRA EL RANGO DE 50 A 2000 ML. FLUJO INSPIRATORIO DE 100 L/MIN O MAYOR. PRESION INSPIRATORIA QUE CUBRA EL RANGO DE 5 A 55 CMH2O. FRECUENCIA RESPIRATORIA QUE CUBRA EL RANGO DE 2 A 60 RESPIRACIONES POR MINUTO. TIEMPO INSPIRATORIO QUE CUBRA EL RANGO DE 0.3 A 3 SEGUNDOS. FIO2 QUE CUBRA EL RANGO DE 40 A 100 %. PEEP/CPAP QUE CUBRA EL RANGO DE 0 A 20 CMH2O. PRESION SOPORTE (PSV) PRESION ASISTIDA O ASB QUE CUBRA EL RANGO DE 0 A 35 CMH2O. CON OPCION MESETA INSPIRATORIA DE PLATEU O PAUSA INSPIRATORIA. RESPIRACION MANUAL. SENSIBILIDAD ESPIRATORIA O TERMINACION DE LA FASE INSPIRATORIA. AJUSTE DE RAMPA DE PRESION RISE TIME RETARDO INSPIRATORIO RAMPA O INCREMENTO DE LA PENDIENTE DE PRESION. 100% DE O2 DURANTE 2 MINUTOS O MAS. MECANISMO DE DISPARO O TRIGGER POR FLUJO Y/O POR PRESION. MODOS VENTILATORIOS: VENTILACION ASISTO CONTROLADA Y SIMV CONTROLADA POR VOLUMEN. VENTILACION ASISTO CONTROLADA Y SIMV CONTROLADA POR PRESION. VENTILACION MANDATORIA INTERMITENTE (SIMV) CON PRESION SOPORTE. PRESION SOPORTE (PSV) O PRESION ASISTIDA O ASB. CPAP O ESPONTANEO CON LINEA DE BASE ELEVADA. RESPALDO EN CASO DE APNEA DE ACUERDO AL MODO VENTILATORIO POR VOLUMEN O PRESION. VENTILACION NO INVASIVA. PARAMETROS MONITORIZADOS: PRESION INSPIRATORIA PICO O MAXIMA. PRESION MEDIA EN VIAS AEREAS. PRESION DE MESETA O PLATEAU. VOLUMEN CORRIENTE INSPIRADO Y ESPIRADO. VOLUMEN MINUTO. PEEP. FRECUENCIA RESPIRATORIA. RELACION I:E. TIEMPO INSPIRATORIO (S). FIO2. CALCULO DE DISTENSIBILIDAD Y/O RESISTENCIA. INDICADOR DE HORAS DE USO. INDICADOR DEL ESTADO DE LA BATERIA DE RESPALDO EN USO. DESPLIEGUE DE AL MENOS 2 DE LAS 3 CURVAS DE VENTILACION DE FORMA SIMULTANEA: VOLUMEN-TIEMPO; FLUJO-TIEMPO; PRESION-TIEMPO. ALARMAS: AUDIBLES Y VISUALES. PRESION INSPIRATORIA ALTA Y BAJA. PEEP BAJO O DESCONEXION DEL PACIENTE. APNEA. VOLUMEN MINUTO Y/O CORRIENTE (ALTO Y BAJO). FRECUENCIA RESPIRATORIA ALTA. FIO2 ALTA Y BAJA. BAJA PRESION DEL SUMINISTRO DE GASES. FALLA DE ALIMENTACION ELECTRICA. BATERIA BAJA. VENTILADOR INOPERANTE FALLA DEL VENTILADOR FALLA TECNICA O FALLA DE CICLO. SILENCIO DE ALARMA. PROGRAMACION AUTOMATICA DE ALARMAS. ACCESORIOS INCLUIDOS: MANGUERA PARA SUMINISTRO DE GAS DE ACUERDO AL CODIGO AMERICANO DE COLORES: O2 - VERDE. DOS CIRCUITOS DE PACIENTE REUSABLES LIBRES DE LATEX (INCLUYE ADAPTADORES CONECTORES Y TRAMPAS DE AGUA). O DIEZ CIRCUITOS DESECHABLES LIBRES DE LATEX PARA PACIENTE ADULTO Y/O PEDIATRICO. DOS SENSORES DE FLUJO DE ADULTO Y DOS SENSORES DE FLUJO PEDIATRICO EN CASO DE QUE LA TECNOLOGIA ASI LO REQUIERA. DIEZ NARICES ARTIFICIALES / FILTRO HME (INTERCAMBIADOR DE HUMEDAD Y TEMPERATURA) PARA USO PEDIATRICO / ADULTO DE ACUERDO A LOS REQUERIMIENTOS DE LA UNIDAD. DIEZ MASCARILLAS DESECHABLES LIBRES DE LATEX PARA VENTILACION NO INVASIVA. TAMAÑO DE ACUERDO A LOS REQUERIMIENTOS DE LA UNIDAD.",
          "description": "VENTILADOR DE TRASLADO CON ACCESORIOS PEDIÁTRICO-ADULTO, NEONATAL",
          "requested_quantity": "35",
          "minimum_quantity": "35",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "76",
          "cucop_code": "53101-1860",
          "specific_item_code": "53101",
          "cucop_description": "531.941.0980 VENTILADOR VOLUMETRICO NEONATAL-PEDIATRICO-ADULTO. EQUIPO ELECTROMECANICO CONTROLADO POR MICROPROCESADOR DE SOPORTE DE VIDA PARA APOYO VENTILATORIO EN PACIENTES QUE TIENEN COMPROMETIDA LA FUNCION RESPIRATORIA. CARACTERISTICAS GENERALES: CON LAS SIGUIENTES CARACTERISTICAS SELECCIONABLES DE ACUERDO A LAS NECESIDADES DE LAS UNIDADES MEDICAS: TECNOLOGIA BASADA EN MICROPROCESADOR QUE INTEGRE SU PROPIO AUTOSUMINISTRO DE AIRE. CON PROGRAMA EN IDIOMA ESPAÑOL. CONTROLADO POR VOLUMEN Y POR PRESION PARA LOS SIGUIENTES MODOS DE VENTILACION: VENTILACION CONTROLADA POR VOLUMEN Y POR PRESION; VENTILACION MANDATORIA INTERMITENTE SINCRONIZADA; PRESION CONTINUA EN LA VIA AEREA; PRESION SOPORTE; RESPALDO EN CASO DE APNEA; MODO NO INVASIVO. COMPENSACION DE TUBO ENDOTRAQUEAL. MEZCLADOR DE AIRE Y OXIGENO INTERNO ELECTRONICAMENTE CONTROLADO. SALIDA PARA NEBULIZADOR SINCRONIZADO CON LA FASE INSPIRATORIA. CAPACIDAD DE REALIZAR AUTOPRUEBA DE FUNCIONAMIENTO. VALVULA DE SOBREPRESION. MEDIDOR DE HORAS DE USO. BATERIA INTERNA CON DURACION MINIMA DE 30 MINUTOS PARA RESPALDO DE LAS FUNCIONES DEL VENTILADOR. REGULADORES DE LA PRESION DE LAS FUENTES DE ALIMENTACION NEUMATICAS INTEGRADOS. SOPORTE RODABLE CON SISTEMA DE FRENO EN AL MENOS DOS RUEDAS. MANUAL DE OPERACION Y DE SERVICIO EN ESPAÑOL. CONTROLES: CON LAS SIGUIENTES CARACTERISTICAS SELECCIONABLES DE ACUERDO A LAS NECESIDADES DE LAS UNIDADES MEDICAS: VENTILACION ASISTIDA EN AL MENOS DOS MODOS DIFERENTES; VENTILACION MANDATORIA INTERMITENTE SINCRONIZADA EN AL MENOS DOS MODOS VENTILATORIOS DIFERENTES; FUNCION DE SELECCION AUTOMATICA DEL MODO VENTILATORIO DE CONTROLADO A ASISTIDO Y VICEVERSA; PRESION POSITIVA AL FINAL DE LA ESPIRACION EN TODOS LOS MODOS VENTILATORIOS. FLUJO INSPIRATORIO MANUAL O AUTOMATICO. QUE ENTREGUE DIFERENTES TIPOS DE FORMA DE ONDA. VOLUMEN CORRIENTE; VOLUMEN MINUTO AJUSTABLE; FRECUENCIA RESPIRATORIA CON CONTROL DE PEEP CON ESCALA REGULABLE. POSIBILIDAD DE MANEJAR RELACION I:E INVERSA. CON PRESION CONTROLADA; PRESION DE SOPORTE AJUSTABLE. SENSIBILIDAD DE DISPARO: POR PRESION Y POR FLUJO CON POSIBILIDAD DE INCREMENTAR LA PENDIENTE DE LA CURVA DE PRESION PAUSAS INSPIRATORIA Y ESPIRATORIA RESPIRACION MANUAL RESPIRACION CON 100% DE OXIGENO DURANTE 2 MINUTOS O MAYOR; FRECUENCIA RESPIRATORIA GRADUABLE VOLUMEN MINUTO RELACION AJUSTABLE I: E O TIEMPO INSPIRATORIO; SOPORTE DE PRESION SENSIBILIDAD DE DISPARO: POR PRESION NEGATIVA PAUSAS INSPIRATORIA Y ESPIRATORIA. ALARMAS: ALARMAS AUDIBLES Y VISIBLES CON LAS SIGUIENTES CARACTERISTICAS SELECCIONABLES DE ACUERDO A LAS NECESIDADES DE LAS UNIDADES MEDICAS: CODIFICADAS O PRIORIZADAS EN 3 NIVELES EN COLOR Y AUDIO: ALTA Y BAJA DE PRESION INSPIRATORIA PICO EN VIAS AEREAS; PRESION EN VIAS AEREAS; ALARMA DE BAJA CONCENTRACION DE FIO2; APNEA. ALARMA DE BAJA PRESION EN EL SUMINISTRO DE GASES: AIRE Y OXIGENO; FALLO DE SUMINISTRO ELECTRICO Y NEUMATICO; FALLAS TECNICAS; BATERIA BAJA. MONITOREO DE PARAMETROS: CON LAS SIGUIENTES CARACTERISTICAS SELECCIONABLES DE ACUERDO A LAS NECESIDADES DE LAS UNIDADES MEDICAS: CON PANTALLA PLANA POLICROMATICA TIPO ELECTROLUMINISCENTE O CRISTAL LIQUIDO MAYOR O IGUAL A 10 PULGADAS EN DIAGONAL PARA DESPLIEGUE DE LOS SIGUIENTES PARAMETROS Y CURVAS: GRAFICAS EN TIEMPO REAL: VOLUMEN-TIEMPO; PRESION-TIEMPO; FLUJO-TIEMPO; VOLUMEN-PRESION; PRESION-VOLUMEN; FLUJO-VOLUMEN; FLUJO-PRESION; OPCIONALES CURVAS ETCO2 SPO2 O PLETISMOGRAFICA. SALIDA PARA IMPRESORA Y OTROS PUERTOS DE COMUNICACION. DESPLIEGUE NUMERICO DE PARAMETROS DE MECANICA RESPIRATORIA: FRECUENCIA RESPIRATORIA PROGRAMADA; FRECUENCIA RESPIRATORIA MEDIDA; PRESION PICO; PRESION MEDIA; PRESION DE MESETA O PRESION ALVEOLAR O PRESION DE PLATEAU; VOLUMEN CORRIENTE PROGRAMADO Y MEDIDO; VOLUMEN MINUTO PROGRAMADO MEDIDO; RELACION I:E; CONCENTRACION DE O2 PROGRAMADA Y MEDIDA; PRESION SUMINISTRO DE GASES; PRESION DE LA PAUSA PEEP VOLUMEN ATRAPADO RESISTENCIA INSPIRATORIA Y ESPIRATORIA COMPLIANZA DINAMICA Y ESTATICA PRESION DE OCLUSION P0.1 INDICE F/VT CALCULO DE LA PRESION INS",
          "description": "VENTILADOR VOLUMÉTRICO CON ACCESORIOS NEONATAL-PEDIÁTRICO- ADULTO",
          "requested_quantity": "60",
          "minimum_quantity": "60",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "77",
          "cucop_code": "53101-1379",
          "specific_item_code": "53101",
          "cucop_description": "531.146.1544 VIDEOBRONCOSCOPIO. EQUIPO COMPUTARIZADO CON VIDEOPROCESADOR DE IMAGENES INVASIVO UTILIZADO PARA EL DIAGNOSTICO Y TRATAMIENTO. TUBO DE INSERCION ENTRE 5.9 Y 6 MM DE DIAMETRO. LONGITUD DE 55 A 60 CM. CANAL DE TRABAJO DENTRO DEL RANGO DE 2.5 A 2.6 MM. ANGULOS DE FLEXION ARRIBA: MAYOR DE 170 GRADOS ABAJO: MAYOR DE 120 ° GRADOS. BOTON PARA CONGELAR IMAGEN EN EL CUERPO DEL ENDOSCOPIO. BOTON PARA ACTIVAR LA VIDEOIMPRESORA EN EL CUERPO DEL ENDOSCOPIO. CON CHIP INTEGRADO EN LA PUNTA DISTAL. VIDEOPROCESADOR DE IMAGENES EN VIVO CON CAPACIDAD PARA VISUALIZAR SIMULTANEAMENTE UN CUADRO DE IMAGENES CONGELADAS Y UN CUADRO DE IMAGENES EN VIVO EN EL MISMO MONITOR CON TECLADO BALANCE DE BLANCO Y DATOS EN PANTALLA. CON FUENTE DE LUZ DE XENON. SALIDA PARA VIDEO COMPUESTO AUTOMATICO Y MANUAL DE BRILLANTEZ.",
          "description": "VIDEOBRONCOSCOPIO",
          "requested_quantity": "3",
          "minimum_quantity": "3",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "78",
          "cucop_code": "53101-1378",
          "specific_item_code": "53101",
          "cucop_description": "531.146.1536 VIDEOBRONCOSCOPIO PEDIATRICO.. EQUIPO PARA OBSERVAR TRAQUEA Y BRONQUIOS CON FINES DIAGNOSTICOS Y TERAPEUTICOS. ENDOSCOPIO DE FIBRA OPTICA FLEXIBLE SUMERGIBLE ANGULO VISUAL: 120 ° VISION FRONTAL; PROFUNDIDAD DE CAMPO 3 A 50 MM DIAMETROS EXTERNOS: TUBO DE INSERCION 3.4 MM Y EXTREMO DISTAL 3.6 MM FLEXION DE LA PUNTA: 180 ° HACIA ARRIBA Y 130 ° HACIA ABAJO; LONGITUDES APROXIMADAS TOTAL 600 MM Y DE TRABAJO 550 MM; CANAL DE TRABAJO MINIMO 1.8 MM.",
          "description": "VIDEOBRONCOSCOPIO PEDIÁTRICO",
          "requested_quantity": "2",
          "minimum_quantity": "2",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "79",
          "cucop_code": "53101-0886",
          "specific_item_code": "53101",
          "cucop_description": "VIDEOLARINGOSCOPIO",
          "description": "VIDEOLARINGOSCOPIO",
          "requested_quantity": "7",
          "minimum_quantity": "7",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        },
        {
          "number": "80",
          "cucop_code": "53101-1695",
          "specific_item_code": "53101",
          "cucop_description": "531.614.0374 PAQUIMETRO ULTRASONICO. APARATO ELECTRONICO QUE PERMITE EL ESTUDIO DEL OJO PARA DETECTAR ALTERACIONES CORNEALES. PARA REALIZAR MEDIDAS EN EL ESPESOR CORNEAL. CON RESOLUCION DE UN MICRON. UN TRANSDUCTOR ANGULADO. CON MODO DE LECTURA AUTOMATICO. CON DESPLIEGUE DIGITAL DE MEDIDA ACTUALY CALCULADA.",
          "description": "PAQUÍMETRO ULTRASÓNICO",
          "requested_quantity": "1",
          "minimum_quantity": "1",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        }
      ]
    }
  ],
  "awards": [
    {
      "id": "C-2024-00097906",
      "internal_reference": "D.G.ADMÓN. SAS-562/CONV/2024",
      "title": "SUSTITUCIONDEL HOSPITAL GENERAL AGUSTIN O' HORANEN MERIDA, YUCATAN",
      "status": "PUBLICADO",
      "contractor": {
        "name": "BTL LABORATORIOS DE TECNOLOGIA SA DE CV",
        "normalized_name": "BTL LABORATORIOS DE TECNOLOGIA",
        "rfc_type": null,
        "slug": "btl-laboratorios-de-tecnologia"
      },
      "contract_period": {
        "published_at": "2024-07-12T02:10:42.000Z",
        "starts_at": "2024-07-10T06:00:00.000Z",
        "ends_at": "2024-12-31T06:00:00.000Z"
      },
      "value": {
        "subtotal": "460000",
        "tax": "73600",
        "total": "533600",
        "maximum_subtotal": "0",
        "maximum_total": "0",
        "currency": "MXN"
      },
      "open_contract_type": null,
      "quantity": null,
      "exercised_quantity": null,
      "participants": [],
      "line_items": [
        {
          "number": "0",
          "cucop_code": "53101-1801",
          "description": "SISTEMA DE MONITORIZACIÓN FISIOLÓGICA EN PRUEBA DE ESFUERZO",
          "unit": "PIEZA",
          "requested_quantity": "1",
          "awarded_quantity": null,
          "unit_price": "460000",
          "subtotal": "460000",
          "tax": "73600",
          "other_taxes": null,
          "total": "533600"
        }
      ]
    },
    {
      "id": "C-2024-00097908",
      "internal_reference": "D.G.ADMÓN. SAS-563/CONV/2024",
      "title": "SUSTITUCIONDEL HOSPITAL GENERAL AGUSTIN O' HORANEN MERIDA, YUCATAN",
      "status": "PUBLICADO",
      "contractor": {
        "name": "COMERCIALIZADORA SARHUA SA DE CV",
        "normalized_name": "COMERCIALIZADORA SARHUA",
        "rfc_type": null,
        "slug": "comercializadora-sarhua"
      },
      "contract_period": {
        "published_at": "2024-07-12T02:10:14.000Z",
        "starts_at": "2024-07-10T06:00:00.000Z",
        "ends_at": "2024-12-31T06:00:00.000Z"
      },
      "value": {
        "subtotal": "11676560",
        "tax": "1868249.6",
        "total": "13544809.6",
        "maximum_subtotal": "0",
        "maximum_total": "0",
        "currency": "MXN"
      },
      "open_contract_type": null,
      "quantity": null,
      "exercised_quantity": null,
      "participants": [],
      "line_items": [
        {
          "number": "0",
          "cucop_code": "53101-1864",
          "description": "VENTILADOR DE ALTA FRECUENCIA OSCILATORIA CON ACCESORIOS PEDIÁTRICO/NEONATAL CON MODO CONVENCIONAL",
          "unit": "PIEZA",
          "requested_quantity": "20",
          "awarded_quantity": null,
          "unit_price": "583828",
          "subtotal": "11676560",
          "tax": "1868249.6",
          "other_taxes": null,
          "total": "13544809.6"
        }
      ]
    },
    {
      "id": "C-2024-00097910",
      "internal_reference": "D.G.ADMÓN. SAS-564/CONV/2024",
      "title": "SUSTITUCIONDEL HOSPITAL GENERAL AGUSTIN O' HORANEN MERIDA, YUCATAN",
      "status": "PUBLICADO",
      "contractor": {
        "name": "COMPAÑIA INTERNACIONAL DE DISTRIBUCIONES SA DE CV",
        "normalized_name": "COMPANIA INTERNACIONAL DE DISTRIBUCIONES",
        "rfc_type": null,
        "slug": "compania-internacional-de-distribuciones"
      },
      "contract_period": {
        "published_at": "2024-07-12T02:09:48.000Z",
        "starts_at": "2024-07-10T06:00:00.000Z",
        "ends_at": "2024-12-31T06:00:00.000Z"
      },
      "value": {
        "subtotal": "9652368",
        "tax": "1544378.88",
        "total": "11196746.88",
        "maximum_subtotal": "0",
        "maximum_total": "0",
        "currency": "MXN"
      },
      "open_contract_type": null,
      "quantity": null,
      "exercised_quantity": null,
      "participants": [],
      "line_items": [
        {
          "number": "0",
          "cucop_code": "53101-1720",
          "description": "MICROSCOPIO PARA OFTALMOCIRUGÍA",
          "unit": "PIEZA",
          "requested_quantity": "1",
          "awarded_quantity": null,
          "unit_price": "4153568",
          "subtotal": "4153568",
          "tax": "664570.88",
          "other_taxes": null,
          "total": "4818138.88"
        },
        {
          "number": "0",
          "cucop_code": "53101-1721",
          "description": "MICROSCOPIO PARA OTORRINOLARINGOLOGÍA",
          "unit": "PIEZA",
          "requested_quantity": "2",
          "awarded_quantity": null,
          "unit_price": "2749400",
          "subtotal": "5498800",
          "tax": "879808",
          "other_taxes": null,
          "total": "6378608"
        }
      ]
    },
    {
      "id": "C-2024-00097911",
      "internal_reference": "D.G.ADMÓN. SAS-565/CONV/2024",
      "title": "SUSTITUCIONDEL HOSPITAL GENERAL AGUSTIN O' HORANEN MERIDA, YUCATAN",
      "status": "PUBLICADO",
      "contractor": {
        "name": "CONCENTRADORA EN TECNOLOGIA HOSPITALARIA SA DE CV",
        "normalized_name": "CONCENTRADORA EN TECNOLOGIA HOSPITALARIA",
        "rfc_type": null,
        "slug": "concentradora-en-tecnologia-hospitalaria"
      },
      "contract_period": {
        "published_at": "2024-07-12T02:09:10.000Z",
        "starts_at": "2024-07-10T06:00:00.000Z",
        "ends_at": "2024-12-31T06:00:00.000Z"
      },
      "value": {
        "subtotal": "8800000",
        "tax": "1408000",
        "total": "10208000",
        "maximum_subtotal": "0",
        "maximum_total": "0",
        "currency": "MXN"
      },
      "open_contract_type": null,
      "quantity": null,
      "exercised_quantity": null,
      "participants": [],
      "line_items": [
        {
          "number": "0",
          "cucop_code": "53101-1326",
          "description": "UNIDAD DE ANESTESIA DE ALTA ESPECIALIDAD.",
          "unit": "PIEZA",
          "requested_quantity": "8",
          "awarded_quantity": null,
          "unit_price": "1100000",
          "subtotal": "8800000",
          "tax": "1408000",
          "other_taxes": null,
          "total": "10208000"
        }
      ]
    },
    {
      "id": "C-2024-00097913",
      "internal_reference": "D.G.ADMÓN. SAS-566/CONV/2024",
      "title": "SUSTITUCIONDEL HOSPITAL GENERAL AGUSTIN O' HORANEN MERIDA, YUCATAN",
      "status": "PUBLICADO",
      "contractor": {
        "name": "DEWIMED SA",
        "normalized_name": "DEWIMED",
        "rfc_type": null,
        "slug": "dewimed"
      },
      "contract_period": {
        "published_at": "2024-07-12T02:08:50.000Z",
        "starts_at": "2024-07-10T06:00:00.000Z",
        "ends_at": "2024-12-31T06:00:00.000Z"
      },
      "value": {
        "subtotal": "30832034.89",
        "tax": "4933125.58",
        "total": "35765160.47",
        "maximum_subtotal": "0",
        "maximum_total": "0",
        "currency": "MXN"
      },
      "open_contract_type": null,
      "quantity": null,
      "exercised_quantity": null,
      "participants": [],
      "line_items": [
        {
          "number": "0",
          "cucop_code": "53101-1336",
          "description": "EQUIPO PARA ARTROSCOPIA (TORRE COMPLETA PARA ARTROSCOPIA)",
          "unit": "PIEZA",
          "requested_quantity": "2",
          "awarded_quantity": null,
          "unit_price": "3301326.27",
          "subtotal": "6602652.54",
          "tax": "1056424.41",
          "other_taxes": null,
          "total": "7659076.95"
        },
        {
          "number": "0",
          "cucop_code": "53101-1552",
          "description": "LASER HOLMIO DE 30 WATTS.",
          "unit": "PIEZA",
          "requested_quantity": "1",
          "awarded_quantity": null,
          "unit_price": "4536827.4",
          "subtotal": "4536827.4",
          "tax": "725892.38",
          "other_taxes": null,
          "total": "5262719.78"
        },
        {
          "number": "0",
          "cucop_code": "53101-1789",
          "description": "SILLÓN PARA OTORRINOLARINGOLOGÍA",
          "unit": "PIEZA",
          "requested_quantity": "1",
          "awarded_quantity": null,
          "unit_price": "124378.11",
          "subtotal": "124378.11",
          "tax": "19900.5",
          "other_taxes": null,
          "total": "144278.61"
        },
        {
          "number": "0",
          "cucop_code": "53101-0868",
          "description": "TORRE DE ENDOUROLOGÍA CON ACCESORIOS.",
          "unit": "PIEZA",
          "requested_quantity": "2",
          "awarded_quantity": null,
          "unit_price": "5858527.39",
          "subtotal": "11717054.78",
          "tax": "1874728.76",
          "other_taxes": null,
          "total": "13591783.54"
        },
        {
          "number": "0",
          "cucop_code": "53101-1765",
          "description": "UNIDAD OFTALMOLÓGICA CON REFRACTOR Y QUERATOMETRO",
          "unit": "PIEZA",
          "requested_quantity": "2",
          "awarded_quantity": null,
          "unit_price": "1458431.93",
          "subtotal": "2916863.86",
          "tax": "466698.22",
          "other_taxes": null,
          "total": "3383562.08"
        },
        {
          "number": "0",
          "cucop_code": "53101-1746",
          "description": "UNIDAD OTORRINOLARINGOLÓGICA",
          "unit": "PIEZA",
          "requested_quantity": "2",
          "awarded_quantity": null,
          "unit_price": "2467129.1",
          "subtotal": "4934258.2",
          "tax": "789481.31",
          "other_taxes": null,
          "total": "5723739.51"
        }
      ]
    },
    {
      "id": "C-2024-00097917",
      "internal_reference": "D.G.ADMÓN. SAS-567/CONV/2024",
      "title": "SUSTITUCIONDEL HOSPITAL GENERAL AGUSTIN O' HORANEN MERIDA, YUCATAN",
      "status": "PUBLICADO",
      "contractor": {
        "name": "ENDOSCOPIA E INSTRUMENTOS SA DE CV",
        "normalized_name": "ENDOSCOPIA E INSTRUMENTOS",
        "rfc_type": null,
        "slug": "endoscopia-e-instrumentos"
      },
      "contract_period": {
        "published_at": "2024-07-12T02:08:31.000Z",
        "starts_at": "2024-07-10T06:00:00.000Z",
        "ends_at": "2024-12-31T06:00:00.000Z"
      },
      "value": {
        "subtotal": "13425000",
        "tax": "2148000",
        "total": "15573000",
        "maximum_subtotal": "0",
        "maximum_total": "0",
        "currency": "MXN"
      },
      "open_contract_type": null,
      "quantity": null,
      "exercised_quantity": null,
      "participants": [],
      "line_items": [
        {
          "number": "0",
          "cucop_code": "53101-1655",
          "description": "EQUIPO PARA LAPAROSCOPIA (TORRE COMPLETA PARA LAPAROSCOPIA)",
          "unit": "PIEZA",
          "requested_quantity": "2",
          "awarded_quantity": null,
          "unit_price": "3300000",
          "subtotal": "6600000",
          "tax": "1056000",
          "other_taxes": null,
          "total": "7656000"
        },
        {
          "number": "0",
          "cucop_code": "53101-1500",
          "description": "UNIDAD DE ELECTROCIRUGÍA - BIPOLAR.",
          "unit": "PIEZA",
          "requested_quantity": "21",
          "awarded_quantity": null,
          "unit_price": "325000",
          "subtotal": "6825000",
          "tax": "1092000",
          "other_taxes": null,
          "total": "7917000"
        }
      ]
    },
    {
      "id": "C-2024-00097925",
      "internal_reference": "D.G.ADMÓN. SAS-568/CONV/2024",
      "title": "SUSTITUCIONDEL HOSPITAL GENERAL AGUSTIN O' HORANEN MERIDA, YUCATAN",
      "status": "PUBLICADO",
      "contractor": {
        "name": "FEHLMEX SA DE CV",
        "normalized_name": "FEHLMEX",
        "rfc_type": null,
        "slug": "fehlmex"
      },
      "contract_period": {
        "published_at": "2024-07-12T02:08:10.000Z",
        "starts_at": "2024-07-10T06:00:00.000Z",
        "ends_at": "2024-12-31T06:00:00.000Z"
      },
      "value": {
        "subtotal": "8815000",
        "tax": "1410400",
        "total": "10225400",
        "maximum_subtotal": "0",
        "maximum_total": "0",
        "currency": "MXN"
      },
      "open_contract_type": null,
      "quantity": null,
      "exercised_quantity": null,
      "participants": [],
      "line_items": [
        {
          "number": "0",
          "cucop_code": "53101-1587",
          "description": "ESTERILIZADOR DE VAPOR AUTOGENERADO 450 L",
          "unit": "PIEZA",
          "requested_quantity": "5",
          "awarded_quantity": null,
          "unit_price": "1325000",
          "subtotal": "6625000",
          "tax": "1060000",
          "other_taxes": null,
          "total": "7685000"
        },
        {
          "number": "0",
          "cucop_code": "53101-1587",
          "description": "ESTERILIZADOR DE VAPOR AUTOGENERADO - 250 LT DE 1 PUERTA",
          "unit": "PIEZA",
          "requested_quantity": "2",
          "awarded_quantity": null,
          "unit_price": "1050000",
          "subtotal": "2100000",
          "tax": "336000",
          "other_taxes": null,
          "total": "2436000"
        },
        {
          "number": "0",
          "cucop_code": "53101-1145",
          "description": "ESTERILIZADOR DE VAPOR AUTOGENERADO PARA LABORATORIO",
          "unit": "PIEZA",
          "requested_quantity": "1",
          "awarded_quantity": null,
          "unit_price": "90000",
          "subtotal": "90000",
          "tax": "14400",
          "other_taxes": null,
          "total": "104400"
        }
      ]
    },
    {
      "id": "C-2024-00097926",
      "internal_reference": "D.G.ADMÓN. SAS-569/CONV/2024",
      "title": "SUSTITUCIONDEL HOSPITAL GENERAL AGUSTIN O' HORANEN MERIDA, YUCATAN",
      "status": "PUBLICADO",
      "contractor": {
        "name": "GE SISTEMAS MEDICOS DE MEXICO SA DE CV",
        "normalized_name": "GE SISTEMAS MEDICOS DE MEXICO",
        "rfc_type": null,
        "slug": "ge-sistemas-medicos-de-mexico"
      },
      "contract_period": {
        "published_at": "2024-07-12T02:07:47.000Z",
        "starts_at": "2024-07-10T06:00:00.000Z",
        "ends_at": "2024-12-31T06:00:00.000Z"
      },
      "value": {
        "subtotal": "3577600",
        "tax": "572416",
        "total": "4150016",
        "maximum_subtotal": "0",
        "maximum_total": "0",
        "currency": "MXN"
      },
      "open_contract_type": null,
      "quantity": null,
      "exercised_quantity": null,
      "participants": [],
      "line_items": [
        {
          "number": "0",
          "cucop_code": "53101-1483",
          "description": "ECOCARDIÓGRAFO BIDIMENSIONAL DOPPLER COLOR",
          "unit": "PIEZA",
          "requested_quantity": "2",
          "awarded_quantity": null,
          "unit_price": "1014800",
          "subtotal": "2029600",
          "tax": "324736",
          "other_taxes": null,
          "total": "2354336"
        },
        {
          "number": "0",
          "cucop_code": "53101-1484",
          "description": "ECOCARDIÓGRAFO TRIDIMENSIONAL DOPPLER COLOR",
          "unit": "PIEZA",
          "requested_quantity": "1",
          "awarded_quantity": null,
          "unit_price": "1548000",
          "subtotal": "1548000",
          "tax": "247680",
          "other_taxes": null,
          "total": "1795680"
        }
      ]
    },
    {
      "id": "C-2024-00097928",
      "internal_reference": "D.G.ADMÓN. SAS-570/CONV/2024",
      "title": "SUSTITUCIONDEL HOSPITAL GENERAL AGUSTIN O' HORANEN MERIDA, YUCATAN",
      "status": "PUBLICADO",
      "contractor": {
        "name": "GUGA EQUIPOS Y SERVICIOS SA DE CV",
        "normalized_name": "GUGA EQUIPOS Y SERVICIOS",
        "rfc_type": null,
        "slug": "guga-equipos-y-servicios"
      },
      "contract_period": {
        "published_at": "2024-07-12T02:07:20.000Z",
        "starts_at": "2024-07-10T06:00:00.000Z",
        "ends_at": "2024-12-31T06:00:00.000Z"
      },
      "value": {
        "subtotal": "909115.2",
        "tax": "145458.43",
        "total": "1054573.63",
        "maximum_subtotal": "0",
        "maximum_total": "0",
        "currency": "MXN"
      },
      "open_contract_type": null,
      "quantity": null,
      "exercised_quantity": null,
      "participants": [],
      "line_items": [
        {
          "number": "0",
          "cucop_code": "53101-1520",
          "description": "KIT DE CONTROL DE CALIDAD PARA RAYOS X Y FLUOROSCOPÍA (FLUORO PHANTON)",
          "unit": "PIEZA",
          "requested_quantity": "3",
          "awarded_quantity": null,
          "unit_price": "303038.4",
          "subtotal": "909115.2",
          "tax": "145458.43",
          "other_taxes": null,
          "total": "1054573.63"
        }
      ]
    },
    {
      "id": "C-2024-00097931",
      "internal_reference": "D.G.ADMÓN. SAS-571/CONV/2024",
      "title": "SUSTITUCIONDEL HOSPITAL GENERAL AGUSTIN O' HORANEN MERIDA, YUCATAN",
      "status": "PUBLICADO",
      "contractor": {
        "name": "INSTRUMENTACION MEDICA SA DE CV",
        "normalized_name": "INSTRUMENTACION MEDICA",
        "rfc_type": null,
        "slug": "instrumentacion-medica"
      },
      "contract_period": {
        "published_at": "2024-07-12T02:06:54.000Z",
        "starts_at": "2024-07-10T06:00:00.000Z",
        "ends_at": "2024-12-31T06:00:00.000Z"
      },
      "value": {
        "subtotal": "12183300",
        "tax": "1949328",
        "total": "14132628",
        "maximum_subtotal": "0",
        "maximum_total": "0",
        "currency": "MXN"
      },
      "open_contract_type": null,
      "quantity": null,
      "exercised_quantity": null,
      "participants": [],
      "line_items": [
        {
          "number": "0",
          "cucop_code": "53101-1408",
          "description": "CÁMARA DIGITAL NO MEDIATRICA PARA FONDO DE OJO, CON CAPACIDAD PARA ESTUDIOS DE FLUORANGIOGRAFIA",
          "unit": "PIEZA",
          "requested_quantity": "1",
          "awarded_quantity": null,
          "unit_price": "2313000",
          "subtotal": "2313000",
          "tax": "370080",
          "other_taxes": null,
          "total": "2683080"
        },
        {
          "number": "0",
          "cucop_code": "53101-1410",
          "description": "CAMPÍMETRO COMPUTARIZADO",
          "unit": "PIEZA",
          "requested_quantity": "2",
          "awarded_quantity": null,
          "unit_price": "990000",
          "subtotal": "1980000",
          "tax": "316800",
          "other_taxes": null,
          "total": "2296800"
        },
        {
          "number": "0",
          "cucop_code": "53101-1585",
          "description": "ESTERILIZADOR DE BAJA TEMPERATURA A TRAVÉS DE PLASMA DE PERÓXIDO DE HIDRÓGENO",
          "unit": "PIEZA",
          "requested_quantity": "3",
          "awarded_quantity": null,
          "unit_price": "2100000",
          "subtotal": "6300000",
          "tax": "1008000",
          "other_taxes": null,
          "total": "7308000"
        },
        {
          "number": "0",
          "cucop_code": "53101-1546",
          "description": "LÁSER QUIRÚRGICO OFTALMOLÓGICO.",
          "unit": "PIEZA",
          "requested_quantity": "1",
          "awarded_quantity": null,
          "unit_price": "1330000",
          "subtotal": "1330000",
          "tax": "212800",
          "other_taxes": null,
          "total": "1542800"
        },
        {
          "number": "0",
          "cucop_code": "53101-1500",
          "description": "UNIDAD DE ELECTROCIRUGÍA DE USO GENERAL - GINECOLÓGICA",
          "unit": "PIEZA",
          "requested_quantity": "1",
          "awarded_quantity": null,
          "unit_price": "260300",
          "subtotal": "260300",
          "tax": "41648",
          "other_taxes": null,
          "total": "301948"
        }
      ]
    },
    {
      "id": "C-2024-00097932",
      "internal_reference": "D.G.ADMÓN. SAS-572/CONV/2024",
      "title": "SUSTITUCIONDEL HOSPITAL GENERAL AGUSTIN O' HORANEN MERIDA, YUCATAN",
      "status": "PUBLICADO",
      "contractor": {
        "name": "GESTUM CONSULTORES SA DE CV",
        "normalized_name": "GESTUM CONSULTORES",
        "rfc_type": null,
        "slug": "gestum-consultores"
      },
      "contract_period": {
        "published_at": "2024-07-12T02:05:56.000Z",
        "starts_at": "2024-07-10T06:00:00.000Z",
        "ends_at": "2024-12-31T06:00:00.000Z"
      },
      "value": {
        "subtotal": "2995190.3",
        "tax": "479230.45",
        "total": "3474420.75",
        "maximum_subtotal": "0",
        "maximum_total": "0",
        "currency": "MXN"
      },
      "open_contract_type": null,
      "quantity": null,
      "exercised_quantity": null,
      "participants": [],
      "line_items": [
        {
          "number": "0",
          "cucop_code": "53101-1381",
          "description": "BRONCOSCOPIO FLEXIBLE DE FIBRA ÓPTICA",
          "unit": "PIEZA",
          "requested_quantity": "1",
          "awarded_quantity": null,
          "unit_price": "1785000",
          "subtotal": "1785000",
          "tax": "285600",
          "other_taxes": null,
          "total": "2070600"
        },
        {
          "number": "0",
          "cucop_code": "53101-1708",
          "description": "MESA QUIRÚRGICA UNIVERSAL AVANZADA - ELÉCTRICA ORTOPÉDICA",
          "unit": "PIEZA",
          "requested_quantity": "2",
          "awarded_quantity": null,
          "unit_price": "605095.15",
          "subtotal": "1210190.3",
          "tax": "193630.45",
          "other_taxes": null,
          "total": "1403820.75"
        }
      ]
    },
    {
      "id": "C-2024-00097933",
      "internal_reference": "D.G.ADMÓN. SAS-573/CONV/2024",
      "title": "SUSTITUCIONDEL HOSPITAL GENERAL AGUSTIN O' HORANEN MERIDA, YUCATAN",
      "status": "PUBLICADO",
      "contractor": {
        "name": "IMPULSO MEXICANO SA DE CV",
        "normalized_name": "IMPULSO MEXICANO",
        "rfc_type": null,
        "slug": "impulso-mexicano"
      },
      "contract_period": {
        "published_at": "2024-07-12T02:05:07.000Z",
        "starts_at": "2024-07-10T06:00:00.000Z",
        "ends_at": "2024-12-31T06:00:00.000Z"
      },
      "value": {
        "subtotal": "25906700",
        "tax": "4145072",
        "total": "30051772",
        "maximum_subtotal": "0",
        "maximum_total": "0",
        "currency": "MXN"
      },
      "open_contract_type": null,
      "quantity": null,
      "exercised_quantity": null,
      "participants": [
        {
          "number": "1",
          "name": "SOLUCIONES MEDICAS COMERCIAL SA DE CV",
          "rfc_type": "moral"
        }
      ],
      "line_items": [
        {
          "number": "0",
          "cucop_code": "53101-1532",
          "description": "UNIDAD RADIOLÓGICA PORTÁTIL - DIGITAL",
          "unit": "PIEZA",
          "requested_quantity": "10",
          "awarded_quantity": null,
          "unit_price": "2590670",
          "subtotal": "25906700",
          "tax": "4145072",
          "other_taxes": null,
          "total": "30051772"
        }
      ]
    },
    {
      "id": "C-2024-00097935",
      "internal_reference": "D.G.ADMÓN. SAS-574/CONV/2024",
      "title": "SUSTITUCIONDEL HOSPITAL GENERAL AGUSTIN O' HORANEN MERIDA, YUCATAN",
      "status": "PUBLICADO",
      "contractor": {
        "name": "CENTRAL MEDICA DE SUMINISTROS SA DE CV",
        "normalized_name": "CENTRAL MEDICA DE SUMINISTROS",
        "rfc_type": null,
        "slug": "central-medica-de-suministros"
      },
      "contract_period": {
        "published_at": "2024-07-12T02:04:35.000Z",
        "starts_at": "2024-07-10T06:00:00.000Z",
        "ends_at": "2024-12-31T06:00:00.000Z"
      },
      "value": {
        "subtotal": "74789580",
        "tax": "11966332.8",
        "total": "86755912.8",
        "maximum_subtotal": "0",
        "maximum_total": "0",
        "currency": "MXN"
      },
      "open_contract_type": null,
      "quantity": null,
      "exercised_quantity": null,
      "participants": [
        {
          "number": "1",
          "name": "ALTA TECNOLOGIA EN EQUIPO MEDICO ISAGEI SA DE CV",
          "rfc_type": "moral"
        }
      ],
      "line_items": [
        {
          "number": "0",
          "cucop_code": "53101-1417",
          "description": "CARRO ROJO CON EQUIPO COMPLETO PARA REANIMACIÓN CON DESFIBRILADOR MONITOR MARCAPASO",
          "unit": "PIEZA",
          "requested_quantity": "59",
          "awarded_quantity": null,
          "unit_price": "203000",
          "subtotal": "11977000",
          "tax": "1916320",
          "other_taxes": null,
          "total": "13893320"
        },
        {
          "number": "0",
          "cucop_code": "53101-1652",
          "description": "LÁMPARA DE HENDIDURA",
          "unit": "PIEZA",
          "requested_quantity": "2",
          "awarded_quantity": null,
          "unit_price": "698200",
          "subtotal": "1396400",
          "tax": "223424",
          "other_taxes": null,
          "total": "1619824"
        },
        {
          "number": "0",
          "cucop_code": "53101-1707",
          "description": "MESA QUIRÚRGICA PARA OBSTETRICIA - ELÉCTRICA",
          "unit": "PIEZA",
          "requested_quantity": "3",
          "awarded_quantity": null,
          "unit_price": "320000",
          "subtotal": "960000",
          "tax": "153600",
          "other_taxes": null,
          "total": "1113600"
        },
        {
          "number": "0",
          "cucop_code": "53101-1708",
          "description": "MESA QUIRÚRGICA UNIVERSAL AVANZADA - ELÉCTRICA",
          "unit": "PIEZA",
          "requested_quantity": "11",
          "awarded_quantity": null,
          "unit_price": "360000",
          "subtotal": "3960000",
          "tax": "633600",
          "other_taxes": null,
          "total": "4593600"
        },
        {
          "number": "0",
          "cucop_code": "53101-1730",
          "description": "CENTRAL DE MONITOREO PARA MÚLTIPLES CAMAS - 6 MONITORES",
          "unit": "PIEZA",
          "requested_quantity": "1",
          "awarded_quantity": null,
          "unit_price": "1402580",
          "subtotal": "1402580",
          "tax": "224412.8",
          "other_taxes": null,
          "total": "1626992.8"
        },
        {
          "number": "0",
          "cucop_code": "53101-1730",
          "description": "CENTRAL DE MONITOREO PARA MÚLTIPLES CAMAS - 10 MONITORES",
          "unit": "PIEZA",
          "requested_quantity": "2",
          "awarded_quantity": null,
          "unit_price": "2034300",
          "subtotal": "4068600",
          "tax": "650976",
          "other_taxes": null,
          "total": "4719576"
        },
        {
          "number": "0",
          "cucop_code": "53101-1730",
          "description": "CENTRAL DE MONITOREO PARA MÚLTIPLES CAMAS - 8 MONITORES",
          "unit": "PIEZA",
          "requested_quantity": "5",
          "awarded_quantity": null,
          "unit_price": "1875600",
          "subtotal": "9378000",
          "tax": "1500480",
          "other_taxes": null,
          "total": "10878480"
        },
        {
          "number": "0",
          "cucop_code": "53101-1492",
          "description": "SISTEMA DE MONITOREO ELECTROCARDIOGRÁFICO CONTINUO Y AMBULATORIO. - HOLTER CARDIACO",
          "unit": "PIEZA",
          "requested_quantity": "2",
          "awarded_quantity": null,
          "unit_price": "325000",
          "subtotal": "650000",
          "tax": "104000",
          "other_taxes": null,
          "total": "754000"
        },
        {
          "number": "0",
          "cucop_code": "53101-1327",
          "description": "UNIDAD DE ANESTESIA BÁSICA.",
          "unit": "PIEZA",
          "requested_quantity": "2",
          "awarded_quantity": null,
          "unit_price": "425000",
          "subtotal": "850000",
          "tax": "136000",
          "other_taxes": null,
          "total": "986000"
        },
        {
          "number": "0",
          "cucop_code": "53101-1328",
          "description": "UNIDAD DE ANESTESIA INTERMEDIA.",
          "unit": "PIEZA",
          "requested_quantity": "11",
          "awarded_quantity": null,
          "unit_price": "665000",
          "subtotal": "7315000",
          "tax": "1170400",
          "other_taxes": null,
          "total": "8485400"
        },
        {
          "number": "0",
          "cucop_code": "53101-1859",
          "description": "VENTILADOR CON ACCESORIOS ADULTO-PEDIÁTRICO-NEONATAL",
          "unit": "PIEZA",
          "requested_quantity": "12",
          "awarded_quantity": null,
          "unit_price": "456000",
          "subtotal": "5472000",
          "tax": "875520",
          "other_taxes": null,
          "total": "6347520"
        },
        {
          "number": "0",
          "cucop_code": "53101-1860",
          "description": "VENTILADOR VOLUMÉTRICO CON ACCESORIOS NEONATAL-PEDIÁTRICO- ADULTO",
          "unit": "PIEZA",
          "requested_quantity": "60",
          "awarded_quantity": null,
          "unit_price": "456000",
          "subtotal": "27360000",
          "tax": "4377600",
          "other_taxes": null,
          "total": "31737600"
        }
      ]
    },
    {
      "id": "C-2024-00097936",
      "internal_reference": "D.G.ADMÓN. SAS-575/CONV/2024",
      "title": "SUSTITUCIONDEL HOSPITAL GENERAL AGUSTIN O' HORANEN MERIDA, YUCATAN",
      "status": "PUBLICADO",
      "contractor": {
        "name": "CONDUIT LIFE SA DE CV",
        "normalized_name": "CONDUIT LIFE",
        "rfc_type": null,
        "slug": "conduit-life"
      },
      "contract_period": {
        "published_at": "2024-07-12T02:04:17.000Z",
        "starts_at": "2024-07-10T06:00:00.000Z",
        "ends_at": "2024-12-31T06:00:00.000Z"
      },
      "value": {
        "subtotal": "14000000",
        "tax": "2240000",
        "total": "16240000",
        "maximum_subtotal": "0",
        "maximum_total": "0",
        "currency": "MXN"
      },
      "open_contract_type": null,
      "quantity": null,
      "exercised_quantity": null,
      "participants": [
        {
          "number": "1",
          "name": "BIOSYSTEMS HLS SA DE CV",
          "rfc_type": "moral"
        }
      ],
      "line_items": [
        {
          "number": "0",
          "cucop_code": "53101-1858",
          "description": "VENTILADOR DE TRASLADO CON ACCESORIOS PEDIÁTRICO-ADULTO, NEONATAL",
          "unit": "PIEZA",
          "requested_quantity": "35",
          "awarded_quantity": null,
          "unit_price": "400000",
          "subtotal": "14000000",
          "tax": "2240000",
          "other_taxes": null,
          "total": "16240000"
        }
      ]
    },
    {
      "id": "C-2024-00097942",
      "internal_reference": "D.G.ADMÓN. SAS-576/CONV/2024",
      "title": "SUSTITUCIONDEL HOSPITAL GENERAL AGUSTIN O' HORANEN MERIDA, YUCATAN",
      "status": "PUBLICADO",
      "contractor": {
        "name": "MANTENIMIENTO PREVENTIVO Y CORRECTIVO SA DE CV",
        "normalized_name": "MANTENIMIENTO PREVENTIVO Y CORRECTIVO",
        "rfc_type": null,
        "slug": "mantenimiento-preventivo-y-correctivo"
      },
      "contract_period": {
        "published_at": "2024-07-12T02:03:57.000Z",
        "starts_at": "2024-07-10T06:00:00.000Z",
        "ends_at": "2024-12-31T06:00:00.000Z"
      },
      "value": {
        "subtotal": "285000",
        "tax": "45600",
        "total": "330600",
        "maximum_subtotal": "0",
        "maximum_total": "0",
        "currency": "MXN"
      },
      "open_contract_type": null,
      "quantity": null,
      "exercised_quantity": null,
      "participants": [
        {
          "number": "1",
          "name": "MANPREC SA DE CV",
          "rfc_type": "moral"
        }
      ],
      "line_items": [
        {
          "number": "0",
          "cucop_code": "53101-1665",
          "description": "LAVADORA DE EQUIPO DE INHALOTERAPIA",
          "unit": "PIEZA",
          "requested_quantity": "1",
          "awarded_quantity": null,
          "unit_price": "285000",
          "subtotal": "285000",
          "tax": "45600",
          "other_taxes": null,
          "total": "330600"
        }
      ]
    },
    {
      "id": "C-2024-00097944",
      "internal_reference": "D.G.ADMÓN. SAS-577/CONV/2024",
      "title": "SUSTITUCIONDEL HOSPITAL GENERAL AGUSTIN O' HORANEN MERIDA, YUCATAN",
      "status": "PUBLICADO",
      "contractor": {
        "name": "NUDOMI SA DE CV",
        "normalized_name": "NUDOMI",
        "rfc_type": null,
        "slug": "nudomi"
      },
      "contract_period": {
        "published_at": "2024-07-12T02:03:40.000Z",
        "starts_at": "2024-07-10T06:00:00.000Z",
        "ends_at": "2024-12-31T06:00:00.000Z"
      },
      "value": {
        "subtotal": "61153000",
        "tax": "9784480",
        "total": "70937480",
        "maximum_subtotal": "0",
        "maximum_total": "0",
        "currency": "MXN"
      },
      "open_contract_type": null,
      "quantity": null,
      "exercised_quantity": null,
      "participants": [
        {
          "number": "1",
          "name": "MANPREC SA DE CV",
          "rfc_type": "moral"
        },
        {
          "number": "2",
          "name": "MANTENIMIENTO PREVENTIVO Y CORRECTIVO SA DE CV",
          "rfc_type": "moral"
        }
      ],
      "line_items": [
        {
          "number": "0",
          "cucop_code": "53101-1528",
          "description": "RAYOS X CON FLUOROSCOPÍA, MÓVIL DIGITAL TIPO ARCO EN C",
          "unit": "PIEZA",
          "requested_quantity": "3",
          "awarded_quantity": null,
          "unit_price": "3650000",
          "subtotal": "10950000",
          "tax": "1752000",
          "other_taxes": null,
          "total": "12702000"
        },
        {
          "number": "0",
          "cucop_code": "53101-1776",
          "description": "UNIDAD DE IMAGEN POR RESONANCIA MAGNÉTICA DE 1.5 TESLAS - CON EQUIPO Y MOBILIARIO ANTIMAGNÉTICO",
          "unit": "PIEZA",
          "requested_quantity": "1",
          "awarded_quantity": null,
          "unit_price": "50203000",
          "subtotal": "50203000",
          "tax": "8032480",
          "other_taxes": null,
          "total": "58235480"
        }
      ]
    },
    {
      "id": "C-2024-00097946",
      "internal_reference": "D.G.ADMÓN. SAS-578/CONV/2024",
      "title": "SUSTITUCIONDEL HOSPITAL GENERAL AGUSTIN O' HORANEN MERIDA, YUCATAN",
      "status": "PUBLICADO",
      "contractor": {
        "name": "REPRESENTACIONES Y DISTRIBUCIONES DEL RELLO SA DE CV",
        "normalized_name": "REPRESENTACIONES Y DISTRIBUCIONES DEL RELLO",
        "rfc_type": null,
        "slug": "representaciones-y-distribuciones-del-rello"
      },
      "contract_period": {
        "published_at": "2024-07-12T02:03:03.000Z",
        "starts_at": "2024-07-10T06:00:00.000Z",
        "ends_at": "2024-12-31T06:00:00.000Z"
      },
      "value": {
        "subtotal": "1180219.26",
        "tax": "188835.08",
        "total": "1369054.34",
        "maximum_subtotal": "0",
        "maximum_total": "0",
        "currency": "MXN"
      },
      "open_contract_type": null,
      "quantity": null,
      "exercised_quantity": null,
      "participants": [],
      "line_items": [
        {
          "number": "0",
          "cucop_code": "53101-1395",
          "description": "CÁMARA SONO-AMORTIGUADORA CON COMPARTIMIENTO SENCILLO",
          "unit": "PIEZA",
          "requested_quantity": "2",
          "awarded_quantity": null,
          "unit_price": "240000",
          "subtotal": "480000",
          "tax": "76800",
          "other_taxes": null,
          "total": "556800"
        },
        {
          "number": "0",
          "cucop_code": "53101-1826",
          "description": "EQUIPO PORTÁTIL PARA TAMIZ AUDITIVO A TRAVÉS DE EMISIONES OTOACÚSTICAS",
          "unit": "PIEZA",
          "requested_quantity": "1",
          "awarded_quantity": null,
          "unit_price": "376531.83",
          "subtotal": "376531.83",
          "tax": "60245.09",
          "other_taxes": null,
          "total": "436776.92"
        },
        {
          "number": "0",
          "cucop_code": "53101-1351",
          "description": "IMPEDANCIOMETRO AVANZADO",
          "unit": "PIEZA",
          "requested_quantity": "1",
          "awarded_quantity": null,
          "unit_price": "323687.43",
          "subtotal": "323687.43",
          "tax": "51789.99",
          "other_taxes": null,
          "total": "375477.42"
        }
      ]
    },
    {
      "id": "C-2024-00097949",
      "internal_reference": "D.G.ADMÓN. SAS-579/CONV/2024",
      "title": "SUSTITUCIONDEL HOSPITAL GENERAL AGUSTIN O' HORANEN MERIDA, YUCATAN",
      "status": "PUBLICADO",
      "contractor": {
        "name": "SERVICIO Y VENTA DE INSUMOS MEDICOS ESPECIALIZADOS SA DE CV",
        "normalized_name": "SERVICIO Y VENTA DE INSUMOS MEDICOS ESPECIALIZADOS",
        "rfc_type": null,
        "slug": "servicio-y-venta-de-insumos-medicos-especializados"
      },
      "contract_period": {
        "published_at": "2024-07-12T02:02:45.000Z",
        "starts_at": "2024-07-10T06:00:00.000Z",
        "ends_at": "2024-12-31T06:00:00.000Z"
      },
      "value": {
        "subtotal": "7006046.63",
        "tax": "1120967.46",
        "total": "8127014.09",
        "maximum_subtotal": "0",
        "maximum_total": "0",
        "currency": "MXN"
      },
      "open_contract_type": null,
      "quantity": null,
      "exercised_quantity": null,
      "participants": [],
      "line_items": [
        {
          "number": "0",
          "cucop_code": "53101-1533",
          "description": "MASTÓGRAFO DIGITAL CON ESTEREOTAXIA Y TOMOSÍNTESIS.",
          "unit": "PIEZA",
          "requested_quantity": "1",
          "awarded_quantity": null,
          "unit_price": "7006046.63",
          "subtotal": "7006046.63",
          "tax": "1120967.46",
          "other_taxes": null,
          "total": "8127014.09"
        }
      ]
    },
    {
      "id": "C-2024-00097951",
      "internal_reference": "D.G.ADMÓN. SAS-580/CONV/2024",
      "title": "SUSTITUCIONDEL HOSPITAL GENERAL AGUSTIN O' HORANEN MERIDA, YUCATAN",
      "status": "PUBLICADO",
      "contractor": {
        "name": "SINCRONIA MEDICA APLICADA SA DE CV",
        "normalized_name": "SINCRONIA MEDICA APLICADA",
        "rfc_type": null,
        "slug": "sincronia-medica-aplicada"
      },
      "contract_period": {
        "published_at": "2024-07-12T02:02:12.000Z",
        "starts_at": "2024-07-10T06:00:00.000Z",
        "ends_at": "2024-12-31T06:00:00.000Z"
      },
      "value": {
        "subtotal": "36380000",
        "tax": "5820800",
        "total": "42200800",
        "maximum_subtotal": "0",
        "maximum_total": "0",
        "currency": "MXN"
      },
      "open_contract_type": null,
      "quantity": null,
      "exercised_quantity": null,
      "participants": [],
      "line_items": [
        {
          "number": "0",
          "cucop_code": "51501-0032",
          "description": "ESTACIÓN DE TRABAJO PARA INTERPRETACIÓN RIS - PACS",
          "unit": "PIEZA",
          "requested_quantity": "2",
          "awarded_quantity": null,
          "unit_price": "9940000",
          "subtotal": "19880000",
          "tax": "3180800",
          "other_taxes": null,
          "total": "23060800"
        },
        {
          "number": "0",
          "cucop_code": "53101-1842",
          "description": "ULTRASONÓGRAFO - DOPPLER COLOR",
          "unit": "PIEZA",
          "requested_quantity": "6",
          "awarded_quantity": null,
          "unit_price": "2750000",
          "subtotal": "16500000",
          "tax": "2640000",
          "other_taxes": null,
          "total": "19140000"
        }
      ]
    },
    {
      "id": "C-2024-00097954",
      "internal_reference": "D.G.ADMÓN. SAS-581/CONV/2024",
      "title": "SUSTITUCIONDEL HOSPITAL GENERAL AGUSTIN O' HORANEN MERIDA, YUCATAN",
      "status": "PUBLICADO",
      "contractor": {
        "name": "SUMINISTRO PARA USO MEDICO Y HOSPITALARIO SA DE CV",
        "normalized_name": "SUMINISTRO PARA USO MEDICO Y HOSPITALARIO",
        "rfc_type": null,
        "slug": "suministro-para-uso-medico-y-hospitalario"
      },
      "contract_period": {
        "published_at": "2024-07-12T02:01:37.000Z",
        "starts_at": "2024-07-10T06:00:00.000Z",
        "ends_at": "2024-12-31T06:00:00.000Z"
      },
      "value": {
        "subtotal": "18914500",
        "tax": "3026320",
        "total": "21940820",
        "maximum_subtotal": "0",
        "maximum_total": "0",
        "currency": "MXN"
      },
      "open_contract_type": null,
      "quantity": null,
      "exercised_quantity": null,
      "participants": [],
      "line_items": [
        {
          "number": "0",
          "cucop_code": "53101-1530",
          "description": "OSTEODENSITÓMETRO",
          "unit": "PIEZA",
          "requested_quantity": "1",
          "awarded_quantity": null,
          "unit_price": "2026000",
          "subtotal": "2026000",
          "tax": "324160",
          "other_taxes": null,
          "total": "2350160"
        },
        {
          "number": "0",
          "cucop_code": "53101-1538",
          "description": "UNIDAD RADIOLÓGICA DIGITAL PARA ESTUDIOS DE TÓRAX",
          "unit": "PIEZA",
          "requested_quantity": "3",
          "awarded_quantity": null,
          "unit_price": "5629500",
          "subtotal": "16888500",
          "tax": "2702160",
          "other_taxes": null,
          "total": "19590660"
        }
      ]
    },
    {
      "id": "C-2024-00097961",
      "internal_reference": "D.G.ADMÓN. SAS-582/CONV/2024",
      "title": "SUSTITUCIONDEL HOSPITAL GENERAL AGUSTIN O' HORANEN MERIDA, YUCATAN",
      "status": "PUBLICADO",
      "contractor": {
        "name": "TECNOLOGIA BIOMEDICA INTEGRAL SA DE CV",
        "normalized_name": "TECNOLOGIA BIOMEDICA INTEGRAL",
        "rfc_type": null,
        "slug": "tecnologia-biomedica-integral"
      },
      "contract_period": {
        "published_at": "2024-07-12T02:01:06.000Z",
        "starts_at": "2024-07-10T06:00:00.000Z",
        "ends_at": "2024-12-31T06:00:00.000Z"
      },
      "value": {
        "subtotal": "627945",
        "tax": "100471.2",
        "total": "728416.2",
        "maximum_subtotal": "0",
        "maximum_total": "0",
        "currency": "MXN"
      },
      "open_contract_type": null,
      "quantity": null,
      "exercised_quantity": null,
      "participants": [],
      "line_items": [
        {
          "number": "0",
          "cucop_code": "53101-1433",
          "description": "COLPOSCÓPIO - CON CÁMARA Y MONITOR.",
          "unit": "PIEZA",
          "requested_quantity": "3",
          "awarded_quantity": null,
          "unit_price": "209315",
          "subtotal": "627945",
          "tax": "100471.2",
          "other_taxes": null,
          "total": "728416.2"
        }
      ]
    },
    {
      "id": "C-2024-00097964",
      "internal_reference": "D.G.ADMÓN. SAS-583/CONV/2024",
      "title": "SUSTITUCIONDEL HOSPITAL GENERAL AGUSTIN O' HORANEN MERIDA, YUCATAN",
      "status": "PUBLICADO",
      "contractor": {
        "name": "TELECOMUNICACION Y EQUIPOS SA DE CV",
        "normalized_name": "TELECOMUNICACION Y EQUIPOS",
        "rfc_type": null,
        "slug": "telecomunicacion-y-equipos"
      },
      "contract_period": {
        "published_at": "2024-07-12T02:00:41.000Z",
        "starts_at": "2024-07-10T06:00:00.000Z",
        "ends_at": "2024-12-31T06:00:00.000Z"
      },
      "value": {
        "subtotal": "19585000",
        "tax": "3133600",
        "total": "22718600",
        "maximum_subtotal": "0",
        "maximum_total": "0",
        "currency": "MXN"
      },
      "open_contract_type": null,
      "quantity": null,
      "exercised_quantity": null,
      "participants": [],
      "line_items": [
        {
          "number": "0",
          "cucop_code": "53101-1447",
          "description": "UNIDAD PARA TOMOGRAFÍA COMPUTARIZADA MULTICOLORES",
          "unit": "PIEZA",
          "requested_quantity": "1",
          "awarded_quantity": null,
          "unit_price": "19585000",
          "subtotal": "19585000",
          "tax": "3133600",
          "other_taxes": null,
          "total": "22718600"
        }
      ]
    }
  ],
  "documents": [
    {
      "id": null,
      "annex_number": 1,
      "document_type": null,
      "description": "CONVOCATORIA",
      "filename": "CONV. T463.pdf",
      "availability": "available",
      "size_bytes": "4226809",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:31:21.249Z",
      "updated_at": "2025-12-01T18:31:21.250Z"
    },
    {
      "id": null,
      "annex_number": 1,
      "document_type": null,
      "description": "AVISO DE SUSPENSIÓN DE JUNTA DE ACLARACIONES",
      "filename": "SUSPNCION JA T463.pdf",
      "availability": "available",
      "size_bytes": "2342488",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:31:26.667Z",
      "updated_at": "2025-12-01T18:31:26.668Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 1.pdf",
      "availability": "available",
      "size_bytes": "2507113",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:18:36.195Z",
      "updated_at": "2025-12-01T18:18:36.196Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 10.pdf",
      "availability": "available",
      "size_bytes": "3517670",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:18:47.449Z",
      "updated_at": "2025-12-01T18:18:47.450Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 11.pdf",
      "availability": "available",
      "size_bytes": "3174536",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:18:50.297Z",
      "updated_at": "2025-12-01T18:18:50.298Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 12.pdf",
      "availability": "available",
      "size_bytes": "4232426",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:18:54.765Z",
      "updated_at": "2025-12-01T18:18:54.767Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 13.pdf",
      "availability": "available",
      "size_bytes": "3187984",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:19:08.327Z",
      "updated_at": "2025-12-01T18:19:08.329Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 14.pdf",
      "availability": "available",
      "size_bytes": "2879231",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:19:16.414Z",
      "updated_at": "2025-12-01T18:19:16.415Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 15.pdf",
      "availability": "available",
      "size_bytes": "3356797",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:19:21.132Z",
      "updated_at": "2025-12-01T18:19:21.134Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 16.pdf",
      "availability": "available",
      "size_bytes": "17103526",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:19:46.939Z",
      "updated_at": "2025-12-01T18:19:46.940Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 17.pdf",
      "availability": "available",
      "size_bytes": "26960959",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:20:36.299Z",
      "updated_at": "2025-12-01T18:20:36.300Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 18.pdf",
      "availability": "available",
      "size_bytes": "26573344",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:21:18.320Z",
      "updated_at": "2025-12-01T18:21:18.321Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 19.pdf",
      "availability": "available",
      "size_bytes": "25152942",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:21:56.707Z",
      "updated_at": "2025-12-01T18:21:56.708Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 2.pdf",
      "availability": "available",
      "size_bytes": "3176205",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:22:01.465Z",
      "updated_at": "2025-12-01T18:22:01.466Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 20.pdf",
      "availability": "available",
      "size_bytes": "16184148",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:22:20.394Z",
      "updated_at": "2025-12-01T18:22:20.395Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 21.pdf",
      "availability": "available",
      "size_bytes": "43039452",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:23:14.219Z",
      "updated_at": "2025-12-01T18:23:14.220Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 22.pdf",
      "availability": "available",
      "size_bytes": "10129711",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:23:35.775Z",
      "updated_at": "2025-12-01T18:23:35.780Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 23.pdf",
      "availability": "available",
      "size_bytes": "11271568",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:23:58.084Z",
      "updated_at": "2025-12-01T18:23:58.085Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 24.pdf",
      "availability": "available",
      "size_bytes": "16967350",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:24:22.463Z",
      "updated_at": "2025-12-01T18:24:22.464Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 25.pdf",
      "availability": "available",
      "size_bytes": "8281748",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:24:37.109Z",
      "updated_at": "2025-12-01T18:24:37.110Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 26.pdf",
      "availability": "available",
      "size_bytes": "22257054",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:25:01.922Z",
      "updated_at": "2025-12-01T18:25:01.923Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 27.pdf",
      "availability": "available",
      "size_bytes": "7848961",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:25:15.373Z",
      "updated_at": "2025-12-01T18:25:15.374Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 28.pdf",
      "availability": "available",
      "size_bytes": "18775629",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:25:50.050Z",
      "updated_at": "2025-12-01T18:25:50.051Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 29.pdf",
      "availability": "available",
      "size_bytes": "8891690",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:25:57.427Z",
      "updated_at": "2025-12-01T18:25:57.428Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 3.pdf",
      "availability": "available",
      "size_bytes": "2992091",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:25:59.988Z",
      "updated_at": "2025-12-01T18:25:59.989Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 30.pdf",
      "availability": "available",
      "size_bytes": "15278325",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:26:27.900Z",
      "updated_at": "2025-12-01T18:26:27.901Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 31.pdf",
      "availability": "available",
      "size_bytes": "10248170",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:26:35.201Z",
      "updated_at": "2025-12-01T18:26:35.202Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 32.pdf",
      "availability": "available",
      "size_bytes": "21835417",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:26:44.905Z",
      "updated_at": "2025-12-01T18:26:44.907Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 33.pdf",
      "availability": "available",
      "size_bytes": "13603265",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:26:53.309Z",
      "updated_at": "2025-12-01T18:26:53.311Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 34.pdf",
      "availability": "available",
      "size_bytes": "16164319",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:27:03.684Z",
      "updated_at": "2025-12-01T18:27:03.685Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 35.pdf",
      "availability": "available",
      "size_bytes": "9762232",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:27:06.874Z",
      "updated_at": "2025-12-01T18:27:06.875Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 36.pdf",
      "availability": "available",
      "size_bytes": "11479426",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:27:11.279Z",
      "updated_at": "2025-12-01T18:27:11.281Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 37.pdf",
      "availability": "available",
      "size_bytes": "11476561",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:27:21.107Z",
      "updated_at": "2025-12-01T18:27:21.108Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 38.pdf",
      "availability": "available",
      "size_bytes": "19689211",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:27:30.614Z",
      "updated_at": "2025-12-01T18:27:30.616Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 39.pdf",
      "availability": "available",
      "size_bytes": "19476074",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:27:40.132Z",
      "updated_at": "2025-12-01T18:27:40.133Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 4.pdf",
      "availability": "available",
      "size_bytes": "3137601",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:27:43.270Z",
      "updated_at": "2025-12-01T18:27:43.271Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 40.pdf",
      "availability": "available",
      "size_bytes": "17906182",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:27:52.895Z",
      "updated_at": "2025-12-01T18:27:52.896Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 41.pdf",
      "availability": "available",
      "size_bytes": "13058204",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:27:59.322Z",
      "updated_at": "2025-12-01T18:27:59.324Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 42.pdf",
      "availability": "available",
      "size_bytes": "13001487",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:28:04.295Z",
      "updated_at": "2025-12-01T18:28:04.296Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 43.pdf",
      "availability": "available",
      "size_bytes": "12980070",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:28:10.749Z",
      "updated_at": "2025-12-01T18:28:10.750Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 44.pdf",
      "availability": "available",
      "size_bytes": "4502787",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:28:13.537Z",
      "updated_at": "2025-12-01T18:28:13.539Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 45.pdf",
      "availability": "available",
      "size_bytes": "4234591",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:28:16.176Z",
      "updated_at": "2025-12-01T18:28:16.177Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 46.pdf",
      "availability": "available",
      "size_bytes": "3037490",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:28:18.247Z",
      "updated_at": "2025-12-01T18:28:18.248Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 47.pdf",
      "availability": "available",
      "size_bytes": "4850506",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:28:21.592Z",
      "updated_at": "2025-12-01T18:28:21.593Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 48.pdf",
      "availability": "available",
      "size_bytes": "3201367",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:28:23.865Z",
      "updated_at": "2025-12-01T18:28:23.866Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 49.pdf",
      "availability": "available",
      "size_bytes": "11232248",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:28:31.205Z",
      "updated_at": "2025-12-01T18:28:31.207Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 5.pdf",
      "availability": "available",
      "size_bytes": "5516833",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:28:33.831Z",
      "updated_at": "2025-12-01T18:28:33.833Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 50.pdf",
      "availability": "available",
      "size_bytes": "11604097",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:28:39.942Z",
      "updated_at": "2025-12-01T18:28:39.944Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 51.pdf",
      "availability": "available",
      "size_bytes": "4480907",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:28:43.815Z",
      "updated_at": "2025-12-01T18:28:43.816Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 52.pdf",
      "availability": "available",
      "size_bytes": "5364900",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:28:48.427Z",
      "updated_at": "2025-12-01T18:28:48.428Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 53.pdf",
      "availability": "available",
      "size_bytes": "4014445",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:28:50.916Z",
      "updated_at": "2025-12-01T18:28:50.918Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 54.pdf",
      "availability": "available",
      "size_bytes": "22179934",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:29:00.622Z",
      "updated_at": "2025-12-01T18:29:00.624Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 55.pdf",
      "availability": "available",
      "size_bytes": "28652391",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:29:07.952Z",
      "updated_at": "2025-12-01T18:29:07.953Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 56.pdf",
      "availability": "available",
      "size_bytes": "16939049",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:29:12.731Z",
      "updated_at": "2025-12-01T18:29:12.733Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 57.pdf",
      "availability": "available",
      "size_bytes": "27821615",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:29:20.791Z",
      "updated_at": "2025-12-01T18:29:20.793Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 58.pdf",
      "availability": "available",
      "size_bytes": "2886603",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:29:23.248Z",
      "updated_at": "2025-12-01T18:29:23.249Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 59.pdf",
      "availability": "available",
      "size_bytes": "3382013",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:29:25.281Z",
      "updated_at": "2025-12-01T18:29:25.282Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 6.pdf",
      "availability": "available",
      "size_bytes": "3029560",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:29:27.752Z",
      "updated_at": "2025-12-01T18:29:27.753Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 60.pdf",
      "availability": "available",
      "size_bytes": "3376973",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:29:29.637Z",
      "updated_at": "2025-12-01T18:29:29.639Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 61.pdf",
      "availability": "available",
      "size_bytes": "3179193",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:29:31.556Z",
      "updated_at": "2025-12-01T18:29:31.557Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 62.pdf",
      "availability": "available",
      "size_bytes": "5829489",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:29:34.348Z",
      "updated_at": "2025-12-01T18:29:34.349Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 63.pdf",
      "availability": "available",
      "size_bytes": "2992184",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:29:36.313Z",
      "updated_at": "2025-12-01T18:29:36.314Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 64.pdf",
      "availability": "available",
      "size_bytes": "3604184",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:29:38.481Z",
      "updated_at": "2025-12-01T18:29:38.482Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 65.pdf",
      "availability": "available",
      "size_bytes": "11617021",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:29:42.085Z",
      "updated_at": "2025-12-01T18:29:42.086Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 66.pdf",
      "availability": "available",
      "size_bytes": "18767683",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:29:47.744Z",
      "updated_at": "2025-12-01T18:29:47.746Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 67.pdf",
      "availability": "available",
      "size_bytes": "19883166",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:29:58.524Z",
      "updated_at": "2025-12-01T18:29:58.526Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 68.pdf",
      "availability": "available",
      "size_bytes": "3752396",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:30:24.407Z",
      "updated_at": "2025-12-01T18:30:24.408Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 69.pdf",
      "availability": "available",
      "size_bytes": "4289249",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:30:28.161Z",
      "updated_at": "2025-12-01T18:30:28.162Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 7.pdf",
      "availability": "available",
      "size_bytes": "3376462",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:30:30.659Z",
      "updated_at": "2025-12-01T18:30:30.660Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 70.pdf",
      "availability": "available",
      "size_bytes": "4748922",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:30:33.492Z",
      "updated_at": "2025-12-01T18:30:33.494Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 71.pdf",
      "availability": "available",
      "size_bytes": "14937194",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:30:37.331Z",
      "updated_at": "2025-12-01T18:30:37.333Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 72.pdf",
      "availability": "available",
      "size_bytes": "4603309",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:30:39.960Z",
      "updated_at": "2025-12-01T18:30:39.961Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 73.pdf",
      "availability": "available",
      "size_bytes": "11753111",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:30:43.197Z",
      "updated_at": "2025-12-01T18:30:43.199Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 74.pdf",
      "availability": "available",
      "size_bytes": "12558432",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:30:48.700Z",
      "updated_at": "2025-12-01T18:30:48.702Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 75.pdf",
      "availability": "available",
      "size_bytes": "3705027",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:30:50.781Z",
      "updated_at": "2025-12-01T18:30:50.782Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 76.pdf",
      "availability": "available",
      "size_bytes": "12692124",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:30:55.598Z",
      "updated_at": "2025-12-01T18:30:55.599Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 77.pdf",
      "availability": "available",
      "size_bytes": "3572888",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:30:57.715Z",
      "updated_at": "2025-12-01T18:30:57.716Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 78.pdf",
      "availability": "available",
      "size_bytes": "3516944",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:31:00.784Z",
      "updated_at": "2025-12-01T18:31:00.786Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 79.pdf",
      "availability": "available",
      "size_bytes": "1747320",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:31:02.916Z",
      "updated_at": "2025-12-01T18:31:02.917Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 8.pdf",
      "availability": "available",
      "size_bytes": "3320418",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:31:05.055Z",
      "updated_at": "2025-12-01T18:31:05.057Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 80.pdf",
      "availability": "available",
      "size_bytes": "3222426",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:31:07.164Z",
      "updated_at": "2025-12-01T18:31:07.166Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "A 9.pdf",
      "availability": "available",
      "size_bytes": "2909920",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:31:09.024Z",
      "updated_at": "2025-12-01T18:31:09.025Z"
    },
    {
      "id": null,
      "annex_number": 3,
      "document_type": null,
      "description": "MODELO DE CONTRATO",
      "filename": "MODELO DE CONTRATO.pdf",
      "availability": "available",
      "size_bytes": "1857752",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:31:12.095Z",
      "updated_at": "2025-12-01T18:31:12.096Z"
    },
    {
      "id": null,
      "annex_number": 4,
      "document_type": null,
      "description": "ANEXOS DE CONVOCATORIA",
      "filename": "ANEXO 1.pdf",
      "availability": "available",
      "size_bytes": "802976",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:31:13.657Z",
      "updated_at": "2025-12-01T18:31:13.659Z"
    },
    {
      "id": null,
      "annex_number": 4,
      "document_type": null,
      "description": "ANEXOS DE CONVOCATORIA",
      "filename": "ANEXO A.pdf",
      "availability": "available",
      "size_bytes": "1298115",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:31:15.667Z",
      "updated_at": "2025-12-01T18:31:15.668Z"
    },
    {
      "id": null,
      "annex_number": 4,
      "document_type": null,
      "description": "ANEXOS DE CONVOCATORIA",
      "filename": "ANEXO C.pdf",
      "availability": "available",
      "size_bytes": "9870429",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:31:18.783Z",
      "updated_at": "2025-12-01T18:31:18.784Z"
    },
    {
      "id": null,
      "annex_number": 5,
      "document_type": null,
      "description": "SUSPENSION DE JUNTA",
      "filename": "Suspension T-463.pdf",
      "availability": "available",
      "size_bytes": "1177580",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:31:23.037Z",
      "updated_at": "2025-12-01T18:31:23.038Z"
    },
    {
      "id": null,
      "annex_number": 8,
      "document_type": null,
      "description": "SUSPENCIÓN DE JUNTA DE ACLRACIONES T-463",
      "filename": "SUSPENCION T463.pdf",
      "availability": "available",
      "size_bytes": "2319800",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:31:24.885Z",
      "updated_at": "2025-12-01T18:31:24.887Z"
    },
    {
      "id": null,
      "annex_number": 10,
      "document_type": null,
      "description": "ACTA JUNTA DE ACLARACIONES",
      "filename": "RESPUESTAS TECS. Y ADTVS.T-463.pdf",
      "availability": "available",
      "size_bytes": "2962397",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:31:28.855Z",
      "updated_at": "2025-12-01T18:31:28.857Z"
    },
    {
      "id": null,
      "annex_number": 11,
      "document_type": null,
      "description": "ACTA CIERRE JUNTA DE ACLARACIONES",
      "filename": "JUNTA DE ACLARCIONES T463 PARTE I.pdf",
      "availability": "available",
      "size_bytes": "220098213",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:32:18.579Z",
      "updated_at": "2025-12-01T18:32:18.580Z"
    },
    {
      "id": null,
      "annex_number": 12,
      "document_type": null,
      "description": "ANEXOS ACTA DE JUNTA DE ACLARACIONES",
      "filename": "ACTA JUNTA DE ACLARACIONES T463 PARTE II.pdf",
      "availability": "available",
      "size_bytes": "200811557",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:32:51.902Z",
      "updated_at": "2025-12-01T18:32:51.903Z"
    },
    {
      "id": null,
      "annex_number": 13,
      "document_type": null,
      "description": "ANEXO ACTA DE APERTURA DE PROPOSICIONES",
      "filename": "ACUSES.pdf",
      "availability": "available",
      "size_bytes": "22549073",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:33:01.606Z",
      "updated_at": "2025-12-01T18:33:01.607Z"
    },
    {
      "id": null,
      "annex_number": 14,
      "document_type": null,
      "description": "ACTA DE APERTURA DE PROPOSICIONES",
      "filename": "ACTA APERT T463.pdf",
      "availability": "available",
      "size_bytes": "3230249",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:33:04.860Z",
      "updated_at": "2025-12-01T18:33:04.862Z"
    },
    {
      "id": null,
      "annex_number": 15,
      "document_type": null,
      "description": "ACTA DIFERIMIENTO FALLO",
      "filename": "ACTA DIF FALLO T463.pdf",
      "availability": "available",
      "size_bytes": "1056513",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:33:06.760Z",
      "updated_at": "2025-12-01T18:33:06.761Z"
    },
    {
      "id": null,
      "annex_number": 16,
      "document_type": null,
      "description": "ANEXOS ACTA DE FALLO",
      "filename": "CARTAS FALLO T-463.pdf",
      "availability": "available",
      "size_bytes": "1285453",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:33:08.581Z",
      "updated_at": "2025-12-01T18:33:08.582Z"
    },
    {
      "id": null,
      "annex_number": 17,
      "document_type": null,
      "description": "ANEXOS ACTA DE FALLO",
      "filename": "ACTA ADMINISTRATIVA T-463.pdf",
      "availability": "available",
      "size_bytes": "209410",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:33:10.138Z",
      "updated_at": "2025-12-01T18:33:10.139Z"
    },
    {
      "id": null,
      "annex_number": 18,
      "document_type": null,
      "description": "ACTA DE FALLO",
      "filename": "ACTA DE FALLO T-463.pdf",
      "availability": "available",
      "size_bytes": "5008154",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:33:14.091Z",
      "updated_at": "2025-12-01T18:33:14.093Z"
    },
    {
      "id": null,
      "annex_number": 19,
      "document_type": null,
      "description": "ANEXOS ACTA DE FALLO",
      "filename": "RESUMEN.pdf",
      "availability": "available",
      "size_bytes": "14279072",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:33:18.420Z",
      "updated_at": "2025-12-01T18:33:18.421Z"
    },
    {
      "id": null,
      "annex_number": 20,
      "document_type": null,
      "description": "ANEXOS ACTA DE FALLO",
      "filename": "JUSTIFICACION.pdf",
      "availability": "available",
      "size_bytes": "25914601",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:33:27.075Z",
      "updated_at": "2025-12-01T18:33:27.077Z"
    },
    {
      "id": null,
      "annex_number": 21,
      "document_type": null,
      "description": "ANEXOS ACTA DE FALLO",
      "filename": "1.pdf",
      "availability": "available",
      "size_bytes": "87394437",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:33:44.949Z",
      "updated_at": "2025-12-01T18:33:44.950Z"
    },
    {
      "id": null,
      "annex_number": 22,
      "document_type": null,
      "description": "ANEXOS ACTA DE FALLO",
      "filename": "pdf24_unido (1).pdf",
      "availability": "available",
      "size_bytes": "160571645",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:34:16.369Z",
      "updated_at": "2025-12-01T18:34:16.371Z"
    },
    {
      "id": null,
      "annex_number": 23,
      "document_type": null,
      "description": "ANEXOS ACTA DE FALLO",
      "filename": "pdf24_unido (2).pdf",
      "availability": "available",
      "size_bytes": "62921918",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:34:33.679Z",
      "updated_at": "2025-12-01T18:34:33.680Z"
    },
    {
      "id": null,
      "annex_number": 24,
      "document_type": null,
      "description": "ANEXOS ACTA DE FALLO",
      "filename": "pdf24_unido (3).pdf",
      "availability": "available",
      "size_bytes": "109969423",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:34:56.812Z",
      "updated_at": "2025-12-01T18:34:56.814Z"
    },
    {
      "id": null,
      "annex_number": 25,
      "document_type": null,
      "description": "ANEXOS ACTA DE FALLO",
      "filename": "pdf24_unido (4).pdf",
      "availability": "available",
      "size_bytes": "33909973",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:35:04.159Z",
      "updated_at": "2025-12-01T18:35:04.160Z"
    },
    {
      "id": null,
      "annex_number": 26,
      "document_type": null,
      "description": "ANEXOS ACTA DE FALLO",
      "filename": "pdf24_unido (5).pdf",
      "availability": "available",
      "size_bytes": "71369627",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:35:17.171Z",
      "updated_at": "2025-12-01T18:35:17.173Z"
    },
    {
      "id": null,
      "annex_number": 27,
      "document_type": null,
      "description": "ANEXOS ACTA DE FALLO",
      "filename": "pdf24_unido (6).pdf",
      "availability": "available",
      "size_bytes": "104421180",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:35:38.383Z",
      "updated_at": "2025-12-01T18:35:38.384Z"
    },
    {
      "id": null,
      "annex_number": 28,
      "document_type": null,
      "description": "ANEXOS ACTA DE FALLO",
      "filename": "pdf24_unido (7).pdf",
      "availability": "available",
      "size_bytes": "94983605",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:35:57.755Z",
      "updated_at": "2025-12-01T18:35:57.756Z"
    },
    {
      "id": null,
      "annex_number": 29,
      "document_type": null,
      "description": "ANEXOS ACTA DE FALLO",
      "filename": "pdf24_unido (8).pdf",
      "availability": "available",
      "size_bytes": "62674821",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:36:20.131Z",
      "updated_at": "2025-12-01T18:36:20.132Z"
    },
    {
      "id": null,
      "annex_number": 30,
      "document_type": null,
      "description": "ANEXOS ACTA DE FALLO",
      "filename": "pdf24_unido (9).pdf",
      "availability": "available",
      "size_bytes": "79848110",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:36:35.794Z",
      "updated_at": "2025-12-01T18:36:35.795Z"
    },
    {
      "id": null,
      "annex_number": 31,
      "document_type": null,
      "description": "ANEXOS ACTA DE FALLO",
      "filename": "pdf24_unido (10).pdf",
      "availability": "available",
      "size_bytes": "88571678",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:36:51.841Z",
      "updated_at": "2025-12-01T18:36:51.842Z"
    },
    {
      "id": null,
      "annex_number": 32,
      "document_type": null,
      "description": "ANEXOS ACTA DE FALLO",
      "filename": "pdf24_unido (11).pdf",
      "availability": "available",
      "size_bytes": "51112880",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:37:02.049Z",
      "updated_at": "2025-12-01T18:37:02.050Z"
    },
    {
      "id": null,
      "annex_number": 33,
      "document_type": null,
      "description": "ANEXOS ACTA DE FALLO",
      "filename": "pdf24_unido (12).pdf",
      "availability": "available",
      "size_bytes": "59500577",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:37:14.682Z",
      "updated_at": "2025-12-01T18:37:14.683Z"
    },
    {
      "id": null,
      "annex_number": 34,
      "document_type": null,
      "description": "ANEXOS ACTA DE FALLO",
      "filename": "pdf24_unido (14).pdf",
      "availability": "available",
      "size_bytes": "122920185",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:37:39.751Z",
      "updated_at": "2025-12-01T18:37:39.753Z"
    },
    {
      "id": null,
      "annex_number": 35,
      "document_type": null,
      "description": "ANEXOS ACTA DE FALLO",
      "filename": "pdf24_unido 13.pdf",
      "availability": "available",
      "size_bytes": "140335108",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:38:10.400Z",
      "updated_at": "2025-12-01T18:38:10.402Z"
    },
    {
      "id": null,
      "annex_number": 36,
      "document_type": null,
      "description": "ANEXOS ACTA DE FALLO",
      "filename": "pdf24_unido (16).pdf",
      "availability": "available",
      "size_bytes": "79478441",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:38:28.133Z",
      "updated_at": "2025-12-01T18:38:28.134Z"
    },
    {
      "id": null,
      "annex_number": 37,
      "document_type": null,
      "description": "TESTIMONIO DE TESTIGO SOCIAL",
      "filename": "Testigo T-463.pdf",
      "availability": "available",
      "size_bytes": "4119069",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-01T18:38:30.454Z",
      "updated_at": "2025-12-01T18:38:30.456Z"
    }
  ],
  "alternates": [],
  "similar": [
    {
      "numero_procedimiento": "la-62-o27-903006996-n-7-2024",
      "nombre_procedimiento": "ADQUISICIÓN DE EQUIPO MÉDICO Y MOBILIARIO PARA EL EQUIPAMIENTO DEL HOSPITAL",
      "dependencia": "SSBCS",
      "siglas": "SSBCS",
      "score": 0.03260091044309421
    },
    {
      "numero_procedimiento": "la-07-110-007000999-t-642-2024",
      "nombre_procedimiento": "CONSTRUCCION DE UN HOSPITAL MILITAR DE ZONA EN LA PLAZA DE CAMPECHE, CAMP.",
      "dependencia": "SEDENA",
      "siglas": "SEDENA",
      "score": 0.03512630180653609
    },
    {
      "numero_procedimiento": "la-50-gyr-050gyr027-t-116-2025",
      "nombre_procedimiento": "ADQUISICION DE EQUIPAMIENTO MÉDICO COMPLEMENTARIO HOSPITAL 72 CAMAS GUANAJUATO",
      "dependencia": "IMSS",
      "siglas": "IMSS",
      "score": 0.04172000413298582
    },
    {
      "numero_procedimiento": "la-75-t20-916011999-n-19-2023",
      "nombre_procedimiento": "ADQUISICIÓN DE EQUIPO MÉD. Y LAB., INSTRUMENTAL MED. Y LAB.Y MOBILIARIO",
      "dependencia": "075T20",
      "siglas": "075T20",
      "score": 0.04411163794661266
    },
    {
      "numero_procedimiento": "la-51-gyn-051gyn020-t-10-2025",
      "nombre_procedimiento": "“ADQUISICIÓN DE EQUIPAMIENTO DEL CENTRO MÉDICO NACIONAL 20  DE NOVIEMBRE”",
      "dependencia": "ISSSTE",
      "siglas": "ISSSTE",
      "score": 0.04448852605946363
    },
    {
      "numero_procedimiento": "la-50-gyr-050gyr031-t-222-2025",
      "nombre_procedimiento": "ADQUISICIÓN DE EQUIPO MÉDICO PARA EL HGZ 15",
      "dependencia": "INSTITUTO MEXICANO DEL SEGURO SOCIAL",
      "siglas": "IMSS",
      "score": 0.04607370633106511
    }
  ]
}