{
  "html_url": "https://licitia.com.mx/licitacion/la-11-l6h-011l6h001-i-5-2025",
  "canonical": "https://licitia.com.mx/licitacion/la-11-l6h-011l6h001-i-5-2025",
  "id": "c335b140e63d45de87af7f337c23c864",
  "procedure_number": "LA-11-L6H-011L6H001-I-5-2025",
  "file_number": "E-2025-00096655",
  "title": "ADQUISICIÓN DE SISTEMA DE SECUENCIACIÓN POR SÍNTESIS PARA EL LABORATORIO NACIONA",
  "description": {
    "short": null,
    "detailed": "SURGE LA NECESIDAD DE CONTAR CON UN SISTEMA DE SECUENCIACIÓN POR SÍNTESIS, PARA CON ELLO OBTENER DATOS MEDIANTE SECUENCIACIÓN DE MUESTRAS ESPECÍFICAS DE ADN, LO QUE PERMITE A LOS INVESTIGADORES COMPRENDER MEJOR LA ESTRUCTURA GENÉTICA Y LA FUNCIÓN DE LOS ORGANISMOS, ASÍ MISMO, ENTENDER LA EVOLUCIÓN BIOLÓGICA, DESARROLLAR NUEVOS MEDICAMENTOS Y TRATAMIENTOS, Y AVANZAR EN CAMPOS COMO LA BIOLOGÍA MOLECULAR Y LA GENÓMICA"
  },
  "lifecycle": {
    "section": "concluido",
    "source_status": "DESIERTO",
    "moved_at": "2025-12-03T10:28:18.271Z"
  },
  "buyer": {
    "agency": "COFAA",
    "acronym": "COFAA",
    "branch": "11 - EDUCACIÓN PÚBLICA",
    "buying_unit": "DIRECCION DE ADQUISICIONES",
    "requesting_unit": "unidad requiriente data",
    "requesting_group": "DIRECCION DE ADQUISICIONES",
    "entity": "COMISION DE OPERACION Y FOMENTO DE ACTIVIDADES ACADEMICAS DEL IPN",
    "slug": "cofaa",
    "unit_slug": "direccion-de-adquisiciones-011l6h001"
  },
  "classification": {
    "procedure_type": "LICITACIÓN PÚBLICA",
    "contracting_type": "ADQUISICIONES",
    "publication_type": null,
    "character": "INTERNACIONAL ABIERTO",
    "fiscal_year": 2025,
    "law": "LEY DE ADQUISICIONES, ARRENDAMIENTOS Y SERVICIOS DEL SECTOR PÚBLICO",
    "legal_basis_id": null,
    "exception_basis": null,
    "internal_control_number": "LA-11-L6H-011L6H001-I-5-2025",
    "supply_source_number": null
  },
  "schedule": {
    "published_at": "2025-10-17T20:43:09.000Z",
    "clarification_meeting_at": "2025-10-23T17:30:00.000Z",
    "clarification_questions_deadline_at": "2025-10-22T17:30:00.000Z",
    "clarification_responses_deadline_at": null,
    "bid_opening_at": "2025-10-29T16:00:00.000Z",
    "award_at": "2025-11-06T20:00:00.000Z",
    "estimated_contract_at": "2025-11-07T06:00:00.000Z",
    "site_visit_at": null,
    "estimated_work_start_at": null
  },
  "estimated_value": {
    "minimum": null,
    "maximum": null,
    "currency": "MXN",
    "updated_at": null
  },
  "lots": [
    {
      "number": "1",
      "name": "PARTIDA SOLA",
      "description": "PARTIDA SOLA",
      "requirement_group_id": "1",
      "items": [
        {
          "number": "1",
          "cucop_code": "53101-1325",
          "specific_item_code": "53101",
          "cucop_description": "531.048.0315 ANALIZADOR AUTOMATIZADO PARA PRUEBAS DE PCR. EL INSTRUMENTO ES UN ANALIZADOR AUTOMATIZADO DE DIAGNOSTICO IN VITRO DISEÑADO PARA SU FUNCIONAMIENTO CON CARTUCHOS DE REACTIVOS ESPECIFICOS PARA DETECTAR MULTIPLES SECUENCIAS DIANA DE ACIDOS NUCLEICOS CONTENIDOS EN MUESTRAS CLINICAS. PARA USO DE LABORATORIOS CLINICOS O DE GABINETE. EL SISTEMA SE COMPONE ENTRE UNO Y OCHO INSTRUMENTOS CONECTADOS A UN ORDENADOR Y RECOPILA ALMACENA Y ANALIZA LOS DATOS GENERADOS POR CADA INSTRUMENTO. EL INSTRUMENTO INTERACTUA CON EL CARTUCHO DE REACTIVOS TANTO PARA PURIFICAR ACIDOS NUCLEICOS COMO PARA AMPLIFICAR SECUENCIAS DE ACIDO NUCLEICO DIANA UTILIZANDO PCR MULTIPLE ANIDADA EN UN SISTEMA CERRADO. LOS PRODUCTOS RESULTANTES DE LA PCR SE EVALUAN MEDIANTE ANALISIS DE FUSION DE ADN. EL SOFTWARE INTERPRETA LOS RESULTADOS AUTOMATICAMENTE Y PRODUCE UN INFORME DESGLOSADO DE LA PRUEBA ESPECIFICANDO EL RESULTADO DE CADA DIANA. CADA SISTEMA SE ENTREGA CON UN INSTRUMENTO ACCESORIOS SISTEMA INFORMATICO IMPRESORA Y GRADILLA DE INSTRUMENTOS (OPCIONAL).",
          "description": "SISTEMA DE SECUENCIACIÓN POR SÍNTESIS.\n\nLOS COMPONENTES DEL SISTEMA DE SECUENCIACIÓN POR SÍNTESIS DEBERÁN SER COMPATIBLES PARA TRABAJAR EN CONJUNTO, ASEGURANDO UNA INTEGRACIÓN FLUIDA Y EFICIENTE PARA QUE AL FUNCIONAR EN SECUENCIA PERMITA DETERMINAR EL ORDEN PRECISO DE LAS BASES NITROGENADAS (ADENINA, TIMINA, GUANINA Y CITOSINA) QUE COMPONEN UNA CADENA DE ADN.\nTECNOLOGÍA DE SECUENCIACIÓN DE NUEVA GENERACIÓN. \nSEGUIMIENTO DE RFID (IDENTIFICACIÓN POR RADIOFRECUENCIA) PARA CONSUMIBLES, SOFTWARE DE CONTROL Y ADMINISTRADOR DE EJECUCIÓN LOCAL DE SOFTWARE INTEGRADO.\nSECUENCIACIÓN METAGENÓMICA DE 16S, SECUENCIACIÓN DE DETECCIÓN GENÉTICO PREIMPLANTACIONAL, SECUENCIACIÓN PEQUEÑA DEL GENOMA COMPLETO, SECUENCIACIÓN DE GENES DIANA.\nCELDAS POR CORRIDA: 1 SALIDA DE 300MB-15GB.\nTIEMPO DE CORRIDA 4-56 HR.\nFILTRO DE PASO EN GRUPO POR CELDA DE FLUJO 1-25 MILLONES\nAMPLIA GAMA DE CELDAS DE FLUJO, NANO, MICRO V2 Y V3 LONGITUD MÁXIMA DE LECTURA 2 X 300 PB.\nDIMENSIONES: ANCHO × PROFUNDIDAD × ALTURA: 68,6 CM × 56,5 CM × 52,3 CM (27,0 IN × 22,2 IN × 20,6 IN).\nALIMENTACIÓN ELÉCTRICA:\nVOLTAJE: 90-264 VOLTAJE DE CA\nFRECUENCIA: 50/60 HZ\nCORRIENTE: 10 A.\nPOTENCIA: 400 W CON SISTEMA DE PROTECCIÓN ANTE DESCARGAS Y/O VARIACIONES ELÉCTRICAS.\n\nEL SISTEMA DE SECUENCIACIÓN CUENTA CON:\n\n- ANALIZADOR DE FRAGMENTOS.\nANALIZADOR DE FRAGMENTOS PARA CONTROL DE CALIDAD DE GENOTECAS.\nANÁLISIS POR MUESTRA DE 1 A 7 MIN PARA FRAGMENTOS DEBAJO DE 1KB.\nRESOLUCIÓN DE 1 A 4 PB PARA FRAGMENTOS POR DEBAJO DE 150PB.\nVOLUMEN MÍNIMO POR MUESTRA: 1-2UL.\nTIPO DE DETECCIÓN: POR FLUORESCENCIA\nRECURSO DE LUZ: LED \nVOLTAJE DE SEPARACIÓN: 1-15KV.\nCONEXIÓN: USB\nADAPTADOR DE CORRIENTE QUE OPERA EN AC 100-240V.\nPESO APROXIMADO: 15KG.\nDIMENSIONES 38X30X40 CM.\nMUESTREO AUTOMÁTICO DE 1-96 MUESTRAS CARTUCHO DE GEL DESECHABLE.\nINCLUYE: SISTEMA DE PROTECCIÓN ANTE DESCARGAS Y/O VARIACIONES ELÉCTRICAS, EQUIPO CON SOFTWARE, KIT DE REACTIVOS PARA 200 CORRIDAS, MARCADO DE ALINEAMIENTO 20 BP& & 1000BP 500UL, 20 BP& & 5000BP 500UL, MARCADOR PBR322",
          "requested_quantity": "2",
          "minimum_quantity": "2",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null
        }
      ]
    }
  ],
  "awards": [],
  "documents": [
    {
      "id": "155853dd-72a0-478e-8e10-f1e8fec1e2cf",
      "annex_number": 1,
      "document_type": null,
      "description": "CONVOCATORIA",
      "filename": "LA-I-5 SEC.pdf",
      "availability": "available",
      "size_bytes": "49671209",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2026-08-04T12:31:20.944Z",
      "updated_at": "2026-08-04T12:31:20.944Z"
    },
    {
      "id": null,
      "annex_number": 1,
      "document_type": null,
      "description": "AVISO DE DIFERIMIENTO DE FALLO",
      "filename": "DIF SECUENC.pdf",
      "availability": "available",
      "size_bytes": "893022",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-03T10:32:26.847Z",
      "updated_at": "2025-12-03T10:32:26.849Z"
    },
    {
      "id": "e0ac1c91-2569-4c5f-a2b2-14647b7b90b2",
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "AT SECUEN.docx",
      "availability": "available",
      "size_bytes": "563078",
      "mime_type": "application/vnd.openxmlformats-officedocument.wordprocessingml.document",
      "sha256": "dba0cd64713268904f1e798b6d96c0e0e532dbe8cdfb65ee70a69937bf0e4a34",
      "uploaded_at": "2026-08-04T12:30:27.467Z",
      "updated_at": "2026-08-06T02:54:00.980Z"
    },
    {
      "id": "5427cfa5-f74f-4f6a-9496-cde24ef1ffff",
      "annex_number": 3,
      "document_type": null,
      "description": "MODELO DE CONTRATO",
      "filename": "MOD CONTRATO.docx",
      "availability": "available",
      "size_bytes": "537860",
      "mime_type": "application/vnd.openxmlformats-officedocument.wordprocessingml.document",
      "sha256": "bb7138b7887a3701609e40eae9fa27658f20366fc4cdc944bd2f41aa4a3c9525",
      "uploaded_at": "2026-08-04T12:30:28.675Z",
      "updated_at": "2026-08-06T02:54:01.043Z"
    },
    {
      "id": "2cca2418-b7ff-494a-9166-54997063505f",
      "annex_number": 4,
      "document_type": null,
      "description": "EDITABLES",
      "filename": "EDITABLES SEC.docx",
      "availability": "available",
      "size_bytes": "761363",
      "mime_type": "application/vnd.openxmlformats-officedocument.wordprocessingml.document",
      "sha256": "b318f31fdde4404ac94a8e3135b851519372a9c240af96a8a31dc2841b018b17",
      "uploaded_at": "2026-08-04T12:30:30.110Z",
      "updated_at": "2026-08-06T02:54:01.106Z"
    },
    {
      "id": "98bc78fd-eb07-4570-9bb4-10c10c746fb1",
      "annex_number": 7,
      "document_type": null,
      "description": "ACTA JUNTA DE ACLARACIONES",
      "filename": "JA 1a parte SEC.pdf",
      "availability": "available",
      "size_bytes": "375742",
      "mime_type": "application/pdf",
      "sha256": "ace5263f220845d8d2568cf95f50085da86a687cf8551ff480f545cdd704aeb3",
      "uploaded_at": "2026-08-04T12:31:22.018Z",
      "updated_at": "2026-08-06T02:54:01.045Z"
    },
    {
      "id": "f42778f2-3c43-4f3c-b91d-62b0f29a0e3d",
      "annex_number": 8,
      "document_type": null,
      "description": "ACTA CIERRE JUNTA DE ACLARACIONES",
      "filename": "JA 2DA SEC.pdf",
      "availability": "available",
      "size_bytes": "6531080",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2026-08-04T12:31:26.084Z",
      "updated_at": "2026-08-04T12:31:26.084Z"
    },
    {
      "id": null,
      "annex_number": 9,
      "document_type": null,
      "description": "ACTA DE APERTURA DE PROPOSICIONES",
      "filename": "APERT DE PROP.pdf",
      "availability": "available",
      "size_bytes": "19145577",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-03T10:32:21.470Z",
      "updated_at": "2025-12-03T10:32:21.472Z"
    },
    {
      "id": null,
      "annex_number": 11,
      "document_type": null,
      "description": "ACTA DE FALLO",
      "filename": "acta_de_fallo-firmada.pdf",
      "availability": "available",
      "size_bytes": "11446948",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-03T10:33:05.388Z",
      "updated_at": "2025-12-03T10:33:05.389Z"
    }
  ],
  "alternates": [],
  "similar": [
    {
      "numero_procedimiento": "la-87-y04-928003999-n-31-2024",
      "nombre_procedimiento": "03..-ADQUISICION DE EQUIPO MEDICO Y DE LABORATORIO",
      "dependencia": "087Y04",
      "siglas": "087Y04",
      "score": 0.22217267751691516
    },
    {
      "numero_procedimiento": "la-77-011-918002995-n-12-2025",
      "nombre_procedimiento": "ADQUISICIÓN DE REACTIVOS, INSUMOS Y EQUIPO PARA EL LABORATORIO DE GENÉTICA",
      "dependencia": "SECRETARÍA DE HACIENDA (NAY)",
      "siglas": "077011",
      "score": 0.2719227347466018
    },
    {
      "numero_procedimiento": "la-48-d00-048d00001-n-668-2025",
      "nombre_procedimiento": "PROGRAMA DE ADQUISICIONES DE EQUIPO CIENTÍFICO Y TECNOLÓGICO PARA LA FORMACIÓN E",
      "dependencia": "INAH",
      "siglas": "INAH",
      "score": 0.29909559499077354
    },
    {
      "numero_procedimiento": "la-78-zi1-919044992-t-14-2025",
      "nombre_procedimiento": "\"ADQUISICIÓN DE EQUIPO DE LABORATORIO Y EQUIPO DIVERSO (TIEMPOS RECORTADOS)\"",
      "dependencia": "SALUDNL",
      "siglas": "SALUDNL",
      "score": 0.30127068742862595
    },
    {
      "numero_procedimiento": "la-75-t35-916039984-n-14-2023",
      "nombre_procedimiento": "PRODUCTOS QUÍMICOS",
      "dependencia": "075T35",
      "siglas": "075T35",
      "score": 0.30301094597382194
    },
    {
      "numero_procedimiento": "la-74-t12-915105899-n-3-2025",
      "nombre_procedimiento": "ADQUISICIÓN DE EQUIPO DE LABORATORIO INSTITUCIONAL",
      "dependencia": "UNIVERSIDAD TECNOLÓGICA DE TECÁMAC",
      "siglas": "UTTÉCAMAC",
      "score": 0.31227680298366023
    }
  ]
}