  "tender": {
    "id": "LA-50-GYR-050GYR041-N-120-2026",
    "title": "SERVICIO DE MANTENIMIENTO  PREVENTIVO A CALDERAS POWER MASTER 150 C.C, 20 C.C",
    "description": "SERVICIO DE MANTENIMIENTO  PREVENTIVO A CALDERAS POWER MASTER 150 C.C, 20 C.C Y EQUIPOS PERIFÉRICOS DE CASA DE MÁQUINAS PARA EL CENTRO VACACIONAL TRINIDAD EJERCICIO 2026",
    "status": "active",
    "procurementMethod": "open",
    "procurementMethodDetails": "LICITACIÓN PÚBLICA",
    "awardCriteriaDetails": "BINARIO",
    "mainProcurementCategory": "goods",
    "tenderPeriod": {
      "startDate": "2026-09-04T18:16:17.000Z",
      "endDate": "2026-09-22T17:30:00.000Z"
    },
    "awardPeriod": {
      "endDate": "2026-09-25T17:30:00.000Z"
    },
    "items": [
      {
        "id": "1",
        "description": "MANTENIMIENTO PREVENTIVO A CALDERA FIRE BURN DE 20 C.C.                                                                                                                                                                                            ACTIVIDADES A REALIZAR:\nAPERTURAS DE TAPAS FRONTAL Y TRASERA.\nLAVADO Y DESHOLLINADO DE TUBOS FLUX Y ESPEJOS CON ESCOBILLÓN Y AGUA A ALTA PRESIÓN.\nCAMBIO DE EMPAQUES DE LAS TAPAS, INCLUYE LOS EMPAQUES.\nLAVADO INTERIOR LADO AGUA DE LA CALDERA QUITANDO REGISTROS MANO Y HOMBRE PARA EFECTUAR LA LIMPIEZA CON AGUA A PRESIÓN HASTA ELIMINAR TODA LA INCRUSTACIÓN QUE SEA FACTIBLE DE QUITAR.\nRETIRAREMOS TUBERÍA DE ALIMENTACIÓN DE AGUA A LA CALDERA CON EL FIN DE VERIFICAR QUE NO HAYA TAPONAMIENTOS QUE IMPIDAN EL LLENADO DE AGUA A LA CALDERA.\nSE CAMBIARÁN EMPAQUES A LOS REGISTROS MANO Y HOMBRE, PARA SU POSTERIOR SELLADO HERMÉTICO.\nSELLADO DE LAS TAPAS, INCLUYE EL MATERIAL DE SELLADO.\nRETIRO DE FLOTADOR DE COLUMNA DE NIVEL Y REALIZACIÓN DE LIMPIEZA DE HOUSING DE ACCIONAMIENTO DEL FLOTADOR, VERIFICANDO VASOS COMUNICANTES CON CALDERA.\nSUMINISTRO Y SUSTITUCIÓN DE VÁLVULAS PORTA NIVEL Y DE PURGA DE MUESTREO.\nREALIZACIÓN DE PRUEBA HIDROSTÁTICA PARA VERIFICAR HERMETICIDAD EN EMPAQUES Y TUBOS FLUX.\nREVISIÓN, LIMPIEZA Y AJUSTES AL TABLERO DE CONTROL.\nREVISIÓN, LIMPIEZA Y AJUSTES AL QUEMADOR.\nANÁLISIS DE GASES Y CARBURACIÓN DEJANDO IMPRESIÓN DE RESULTADOS ANTES Y DESPUÉS DE CARBURACIÓN, DICHOS RESULTADOS CUMPLIRÁN LOS PARÁMETROS QUE MARCA LA NORMA NOM085SEMARNAT2011 PARA LA EMISIÓN DE GASES CONTAMINANTES DE FUENTES FIJAS.\nSE REALIZARÁN PRUEBAS DE SEGURIDAD Y FALLAS DE FLAMA Y DE BAJO NIVEL EN COLUMNA PRINCIPAL Y AUXILIAR.\nREVISIÓN GENERAL DE ACCESORIOS Y EQUIPO PERIFÉRICO DE LA CALDERA PARA ASEGURAR UN BUEN FUNCIONAMIENTO, COMO SON: LÍNEA DE ALIMENTACIÓN DE AGUA Y DE COMBUSTIBLE, LÍNEA DE PURGAS TANTO PRINCIPAL COMO DE COLUMNA DE NIVEL; CABEZAL DE DISTRIBUCIÓN DE VAPOR Y DEMÁS EQUIPO PERIFÉRICO QUE SE ENCUENTRE INSTALADO.",
        "classification": {
          "scheme": "CUCOP",
          "id": "35701-0001",
          "description": "MAQUINARIA Y EQUIPO (MANTENIMIENTO Y REPARACION)"
        },
        "quantity": 1,
        "additionalClassifications": [
          {
            "scheme": "CUCOP-partida",
            "id": "35701",
            "description": "MANTENIMIENTO Y CONSERVACIÓN DE MAQUINARIA Y EQUIPO"
          }
        ],
        "unit": {
          "name": "SERVICIO"
        }
      },
      {
        "id": "2",
        "description": "MANTENIMIENTO PREVENTIVO A DOS CALDERAS POWER MASTER DE 150 C.C.                                                                                                                                                                                            ACTIVIDADES A REALIZAR:\nAPERTURAS DE TAPAS FRONTAL Y TRASERA.\nLAVADO Y DESHOLLINADO DE TUBOS FLUX Y ESPEJOS CON ESCOBILLÓN Y AGUA A ALTA PRESIÓN.\nCAMBIO DE EMPAQUES DE LAS TAPAS, INCLUYE LOS EMPAQUES.\nLAVADO INTERIOR LADO AGUA DE LA CALDERA QUITANDO REGISTROS MANO Y HOMBRE PARA EFECTUAR LA LIMPIEZA CON AGUA A PRESIÓN HASTA ELIMINAR TODA LA INCRUSTACIÓN QUE SEA FACTIBLE DE QUITAR.\nRETIRAREMOS TUBERÍA DE ALIMENTACIÓN DE AGUA A LA CALDERA CON EL FIN DE VERIFICAR QUE NO HAYA TAPONAMIENTOS QUE IMPIDAN EL LLENADO DE AGUA A LA CALDERA.\nSE CAMBIARÁN EMPAQUES A LOS REGISTROS MANO Y HOMBRE, PARA SU POSTERIOR SELLADO HERMÉTICO.\nSELLADO DE LAS TAPAS, INCLUYE EL MATERIAL DE SELLADO.\nRETIRO DE FLOTADOR DE COLUMNA DE NIVEL Y REALIZACIÓN DE LIMPIEZA DE HOUSING DE ACCIONAMIENTO DEL FLOTADOR, VERIFICANDO VASOS COMUNICANTES CON CALDERA.\nSUMINISTRO Y SUSTITUCIÓN DE VÁLVULAS PORTA NIVEL Y DE PURGA DE MUESTREO.\nLIMPIEZA A VARILLA DE ELECTRODO DE NIVEL DEL SISTEMA AUXILIAR DE NIVEL.\nREALIZACIÓN DE PRUEBA HIDROSTÁTICA PARA VERIFICAR HERMETICIDAD EN EMPAQUES Y TUBOS FLUX.\nREVISIÓN, LIMPIEZA Y AJUSTES AL TABLERO DE CONTROL.\nREVISIÓN, LIMPIEZA Y AJUSTES AL QUEMADOR.\n REVISION DE BOBINAS DEL SISTEMA DE REGULACIÓN DEL QUEMADOR Y ALIMENTACIÓN DE GAS.\nANÁLISIS DE GASES Y CARBURACIÓN DEJANDO IMPRESIÓN DE RESULTADOS ANTES Y DESPUÉS DE CARBURACIÓN, DICHOS RESULTADOS CUMPLIRÁN LOS PARÁMETROS QUE MARCA LA NORMA NOM085SEMARNAT2011 PARA LA EMISIÓN DE GASES CONTAMINANTES DE FUENTES FIJAS.",
        "classification": {
          "scheme": "CUCOP",
          "id": "35701-0001",
          "description": "MAQUINARIA Y EQUIPO (MANTENIMIENTO Y REPARACION)"
        },
        "quantity": 1,
        "additionalClassifications": [
          {
            "scheme": "CUCOP-partida",
            "id": "35701",
            "description": "MANTENIMIENTO Y CONSERVACIÓN DE MAQUINARIA Y EQUIPO"
          }
        ],
        "unit": {
          "name": "SERVICIO"
        }
      },
      {
        "id": "3",
        "description": "MANTENIMIENTO PREVENTIVO A EQUIPOS PERIFERICOS DEL CUARTO DE CASA DE MAQUINAS PRINCIPAL:\nINCLUYE:\n\nMANTENIMIENTO PREVENTIVO CAMBIO DE  VALVULA FLOTADOR DEL TANQUE DE CONDENZADOS Y AJUSTE DE NIVEL EN EL TANQUE. \nREVISION Y LIMPIEZA DE FILTROS DE TUBERIA Y VALVULAS CHECK  VALIDANDO EL CORRECTO FUNCIONAMIENTO.\nMANTENIMIENTO PREVENTIVO A BOMBAS DE TANQUE DE CONDENSADOS MARCA GRUNDFOS 3HP, CAMBIO DE RODAMIENTOS, CAMBIO SE SELLO MECANICO, CAMBIO DE RETENES, REVISION DE BOBINADO ( CAMBIO SI LO REQUIERE) Y TODO LO NECESARIO PAR SU CORRECTO FUNCIONAMIENTO.\nREVISION DEL CORRECTO FUNCIONAMIENTO DE LAS VALVULAS COLUMNA DE NIVEL Y CAMBIO DE LAS MISMAS SI SE REQUIERE EN EL TANQUE DE CONDENSADOS.",
        "classification": {
          "scheme": "CUCOP",
          "id": "35701-0001",
          "description": "MAQUINARIA Y EQUIPO (MANTENIMIENTO Y REPARACION)"
        },
        "quantity": 1,
        "additionalClassifications": [
          {
            "scheme": "CUCOP-partida",
            "id": "35701",
            "description": "MANTENIMIENTO Y CONSERVACIÓN DE MAQUINARIA Y EQUIPO"
          }
        ],
        "unit": {
          "name": "SERVICIO"
        }
      },
      {
        "id": "4",
        "description": "MANTENIMIENTO ANUAL :\nA. DESCALCIFICACIÓN DEL INTERCAMBIADOR DE CALOR\nCON AYUDA DE UNA BOMBA RECIRCULADORA HACER CIRCULAR UNA SOLUCIÓN QUÍMICA DESINCRUSTANTE (ÁCIDO CÍTRICO O PRODUCTOS REACTIVOS INHIBIDOS PARA NO DAÑAR EL COBRE) PARA DISOLVER EL SARRO.\nB. LIMPIEZA DEL BLOQUE DE QUEMADORES Y TOBERAS\nDESMONTAR LAS FLAUTAS DE QUEMADORES PARA ASPIRAR EL HOLLÍN, POLVO O RESIDUOS DE COMBUSTIÓN. SE LIMPIAN LAS ESPREAS (TOBERAS) PARA ASEGURAR QUE EL GAS FLUYA UNIFORMEMENTE.\nC. REVISIÓN DEL SISTEMA DE IGNICIÓN Y SEGURIDAD\nLIMPIEZA DEL SENSOR DE IONIZACIÓN (O TERMOPAR): LIJAR SUAVEMENTE PARA RETIRAR LA CARBONILLA. SI ESTE SENSOR NO DETECTA LA LLAMA CORRECTAMENTE REALIZAR EL CAMBIO. \nACTIVAR MANUALMENTE LA VÁLVULA DE ALIVIO DE PRESIÓN PARA ASEGURAR QUE NO ESTÉ PEGADA POR EL SARRO.\nD. INSPECCIÓN DEL SISTEMA DE EVACUACIÓN DE GASES\nREVISAR QUE EL DUCTO DE VENTILACIÓN (CHIMENEA) NO ESTÉ OBSTRUIDO POR NIDOS DE AVES, HOLLÍN U OBJETOS EXTRAÑOS, Y QUE EL EXTRACTOR DE HUMOS (SI ES DE TIRO FORZADO) FUNCIONE SUAVEMENTE Y SIN RUIDOS EXTRAÑOS.\nREVISAR EL CORRECTO FUNCIONAMIENTO DEL SISTEMA DE ENCENDIDO AUTOMÁTICO DE LA CALDERETA EN CASO DE ENCONTRAR ALGUNA FALLA O ANOMALÍA REEMPLAZAR LOS ELEMENTOS NECESARIOS PARA DEJAR EN ÓPTIMAS CONDICIONES EL EQUIPO.",
        "classification": {
          "scheme": "CUCOP",
          "id": "35701-0001",
          "description": "MAQUINARIA Y EQUIPO (MANTENIMIENTO Y REPARACION)"
        },
        "quantity": 1,
        "additionalClassifications": [
          {
            "scheme": "CUCOP-partida",
            "id": "35701",
            "description": "MANTENIMIENTO Y CONSERVACIÓN DE MAQUINARIA Y EQUIPO"
          }
        ],
        "unit": {
          "name": "SERVICIO"
        }
      },
      {
        "id": "5",
        "description": "MANTENIMIENTO PREVENTIVO A EQUIPOS PERIFERICOS DEL CUARTO DE CASA DE MAQUINAS PRINCIPAL.\nINCLUYE:\nMANTENIMIENTO PREVENTIVO, A SUAVISADORES REALIZANDO CAMBIO DE EMPAQUES Y RETENES ASEGURANDO EL CORRECTO FUNCIONAMIENTO Y CERO FUGAS.\n\nMANTENIMIENTO PREVENTIVO A BOMBAS DOSIFICADORAS ELECTRONICAS AUTOMATICAS DE SUAVISADORES Y PARA ADICIÓN DE CLORO. REALIZANDO EL CAMBIO DE KIT DE MEMBRANA RECORTE DE MANGUERAS Y VALIDACION DE CONECCIONES (DE SER NECESARIO EL CAMBIO REALIZAR) Y LIMPIEZA DE LA BOMBA.\n ASEGURANDO QUE LA DOSIFICACION  SEA CORRECTA  DE CADA BOMBA ENTREGANDO LOS 4.73 LPH A UNA PRESION DE 7 BARES Y LA OTRA DE  ENTREGANDO 4 LPH A UNA PRESION MAXIMA DE 10 BARES RESPECTIVAMENTE DE ACUERDO A LA PLACA DE DATOS.",
        "classification": {
          "scheme": "CUCOP",
          "id": "35701-0001",
          "description": "MAQUINARIA Y EQUIPO (MANTENIMIENTO Y REPARACION)"
        },
        "quantity": 1,
        "additionalClassifications": [
          {
            "scheme": "CUCOP-partida",
            "id": "35701",
            "description": "MANTENIMIENTO Y CONSERVACIÓN DE MAQUINARIA Y EQUIPO"
          }
        ],
        "unit": {
          "name": "SERVICIO"
        }
      }
    ],
    "documents": [
      {
        "id": "1",
        "title": "CONV CALDERAS.docx",
        "url": "https://comprasmx.buengobierno.gob.mx/sitiopublico/#/sitiopublico/detalle/3f91d5a761344ffc9a88228a4d9c1ab8/procedimiento",
        "documentType": "biddingDocuments",
        "datePublished": "2026-09-04T18:21:36.556Z"
      },
      {
        "id": "2",
        "title": "ANEXO TECNICO.pdf",
        "url": "https://comprasmx.buengobierno.gob.mx/sitiopublico/#/sitiopublico/detalle/3f91d5a761344ffc9a88228a4d9c1ab8/procedimiento",
        "documentType": "biddingDocuments",
        "datePublished": "2026-09-04T18:21:31.606Z"
      },
      {
        "id": "3",
        "title": "MOD CONT.DOCX",
        "url": "https://comprasmx.buengobierno.gob.mx/sitiopublico/#/sitiopublico/detalle/3f91d5a761344ffc9a88228a4d9c1ab8/procedimiento",
        "documentType": "biddingDocuments",
        "datePublished": "2026-09-04T18:21:33.778Z"
      },
      {
        "id": "4",
        "title": "ACTA_JA_LA-50-GYR-050GYR041-N-120-2026.pdf",
        "url": "https://comprasmx.buengobierno.gob.mx/sitiopublico/#/sitiopublico/detalle/3f91d5a761344ffc9a88228a4d9c1ab8/procedimiento",
        "documentType": "biddingDocuments",
        "datePublished": "2026-09-10T19:03:35.990Z"
      },
      {
        "id": "5",
        "title": "Documento_Word_1.docx",
        "url": "https://comprasmx.buengobierno.gob.mx/sitiopublico/#/sitiopublico/detalle/3f91d5a761344ffc9a88228a4d9c1ab8/procedimiento",
        "documentType": "biddingDocuments",
        "datePublished": "2026-09-04T18:21:38.738Z"
      }
    ]
  },
  "awards": [],
  "extensions": {
    "source": "ComprasMX",
    "canonical": "https://licitia.com.mx/licitacion/la-50-gyr-050gyr041-n-120-2026",
    "license": "https://creativecommons.org/licenses/by/4.0/",
    "ocidPrefixRegistered": false
  }
}