{
  "html_url": "https://licitia.com.mx/proveedor/healthcare-systems-de-mexico",
  "canonical": "https://licitia.com.mx/proveedor/healthcare-systems-de-mexico",
  "id": "1039342",
  "slug": "healthcare-systems-de-mexico",
  "displayName": "HEALTHCARE SYSTEMS DE MEXICO SA DE CV",
  "normalizedName": "healthcare-systems-de-mexico",
  "aliasCount": 1,
  "totalContracts": 132,
  "totalProcedures": 124,
  "totalAwardedAmount": "1198793017.35",
  "minAmount": "40832",
  "maxAmount": "97440000",
  "medianAmount": "1865033.5",
  "suspectContracts": 0,
  "foreignContracts": 0,
  "foreignTotals": null,
  "distinctBuyers": 14,
  "distinctStates": 20,
  "distinctCucop": 56,
  "topBuyers": [
    {
      "slug": "imss",
      "monto": 659329647.46,
      "nombre": "INSTITUTO MEXICANO DEL SEGURO SOCIAL",
      "contratos": 77
    },
    {
      "slug": "imss-bienestar-056ayo",
      "monto": 197703092,
      "nombre": "SERVICIOS DE SALUD DEL INSTITUTO MEXICANO DEL SEGURO SOCIAL PARA EL BIENESTAR (IMSS-BIENESTAR)",
      "contratos": 5
    },
    {
      "slug": "sedena",
      "monto": 124694078.59,
      "nombre": "SECRETARIA DE LA DEFENSA NACIONAL",
      "contratos": 12
    },
    {
      "slug": "sapuebla",
      "monto": 55332000,
      "nombre": "SECRETARÍA DE PLANEACIÓN, FINANZAS Y ADMINISTRACIÓN (PUE)",
      "contratos": 1
    },
    {
      "slug": "sesa",
      "monto": 46496571.8,
      "nombre": "SECRETARÍA DE SALUD (QRO)",
      "contratos": 5
    },
    {
      "slug": "incmnsz",
      "monto": 45796960,
      "nombre": "INSTITUTO NACIONAL DE CIENCIAS MÉDICAS Y NUTRICIÓN SALVADOR ZUBIRÁN",
      "contratos": 2
    },
    {
      "slug": "inper",
      "monto": 15159901.86,
      "nombre": "INSTITUTO NACIONAL DE PERINATOLOGÍA ISIDRO ESPINOSA DE LOS REYES",
      "contratos": 5
    },
    {
      "slug": "imss-bienestar-sin-identificar",
      "monto": 15159181.6,
      "nombre": "IMSS-BIENESTAR",
      "contratos": 6
    },
    {
      "slug": "insabi",
      "monto": 13663538.1,
      "nombre": "INSTITUTO DE SALUD PARA EL BIENESTAR",
      "contratos": 7
    },
    {
      "slug": "him",
      "monto": 12972834.49,
      "nombre": "HOSPITAL INFANTIL DE MÉXICO FEDERICO GÓMEZ",
      "contratos": 7
    },
    {
      "slug": "069q55",
      "monto": 10920936,
      "nombre": "SECRETARÍA DE SALUD (DGO)",
      "contratos": 2
    },
    {
      "slug": "iner",
      "monto": 790200.19,
      "nombre": "INSTITUTO NACIONAL DE ENFERMEDADES RESPIRATORIAS ISMAEL COSÍO VILLEGAS",
      "contratos": 1
    },
    {
      "slug": "issste",
      "monto": 443265,
      "nombre": "INSTITUTO DE SEGURIDAD Y SERVICIOS SOCIALES DE LOS TRABAJADORES DEL ESTADO",
      "contratos": 1
    },
    {
      "slug": "ssaludtab",
      "monto": 330810.26,
      "nombre": "SECRETARÍA DE SALUD (TAB)",
      "contratos": 1
    }
  ],
  "topCucop": [
    {
      "clave": "53101-0388",
      "monto": 388796235.84,
      "partidas": 12,
      "descripcion": "ANGIOGRAFO"
    },
    {
      "clave": "53101-1330",
      "monto": 185671800.64,
      "partidas": 6,
      "descripcion": "531.055.0024 ANGIOGRAFO ARCO MONOPLANAR. SISTEMA DE RAYOS \"\"X\"\" PARA ESTUDIOS DIAGNOSTICOS Y TERAPEUTICOS. CON LAS SIGUIENTES CARACTERISTICAS SELECCIONABLES DE ACUERDO A LAS NECESIDADES DE LAS UNIDADES MEDICAS: INTEGRADO POR UN ARCO AL PISO O AL TECHO CON LAS SIGUIENTES CARACTERISTICAS DE ACUERDO A APLICACIONES DIAGNOSTICAS Y DE TRATAMIENTO: ROTACION Y ANGULACION MOVIMIENTO AXIAL MANUAL O MOTORIZADO DEL INTENSIFICADOR DE IMAGEN O PANTALLA PLANA PARA AJUSTAR LA DISTANCIA FOCO-PACIENTE DISTANCIA VARIABLE ENTRE EL FOCO Y LA PANTALLA DEL INTENSIFICADOR DE IMAGEN PROFUNDIDAD DEL BRAZO MOVIMIENTOS MOTORIZADOS DEL ARCO DE VELOCIDAD VARIABLE CON ROTACION Y ANGULACION INTENSIFICADOR DE IMAGEN O PANTALLA PLANA CON PROTECCION CONTRA O ANTICOLISION. MESA PARA EL PACIENTE: CON MOVIMIENTO LONGITUDINAL Y TRANSVERSAL AJUSTE DE LA ALTURA CARGA MAXIMA DEL PACIENTE. SISTEMA DE RAYOS \"\"X : GENERADOR DE RAYOS \"\"X\"\" DE ALTA FRECUENCIA CONTROLADO POR MICROPROCESADOR CORRIENTE DEL GENERADOR TUBO DE RAYOS \"\"X\"\" CON DOS PUNTOS FOCALES CON CAPACIDAD DE ALMACENAMIENTO DE CALOR DEL ANODO Y CAPACIDAD DE DISIPACION DE CALOR POSICION MANUAL O AUTOMATICA. FILTRACION DE LA RADIACION. SISTEMA DE ADQUISICION: PROGRAMAS PARA FLUOROSCOPIA CON CONTROL DE DOSIS PROCESAMIENTO DIGITAL Y SELECCION DE FILTROS DE RAYOS \"\"X\"\" A IMPULSOS PARA FLUOROSCOPIA PULSADA. CADENA DIGITAL DE TV CON SALIDA DIGITAL CUATRO MONITORES DE ALTA RESOLUCION PANTALLA ANTIRREFLEJANTE CON ADAPTACION AUTOMATICA DEL BRILLO Y CONTRASTE A LAS CONDICIONES DE LA SALA. SUSPENSION A TECHO PARA COLOCACION DE MONITORES. MODULO O CONSOLA DE DESPLIEGUE QUE APORTE INFORMACION SOBRE: EL ESTADO DE ROTACION/ANGULACION DEL BRAZO MENSAJES DEL SISTEMA EL ESTADO DE CARGA DE LOS TUBOS. DE RAYOS \"\"X\"\" LA MODALIDAD FLUORO SELECCIONADA Y CAMPO DE LOS INTENSIFICADORES DE IMAGEN O CAMPOS O AREAS DE VISION O IMAGEN. MODULO PARA LECTURA DE LA TASA DE DOSIS DE RADIACION EN CGY/CM2/SEG Y CRONOMETRO. ESTACION DE TRABAJO CON MONITOR TECLADO ALFANUMERICO Y MOUSE. CAPACIDAD PARA ADQUISICION Y ALMACENAMIENTO DE SEÑALES FISIOLOGICAS Y SU DESPLIEGUE. PROCESAMIENTO DE IMAGEN: MATRICES Y VELOCIDADES DE ADQUISICION Y CON SUSTRACCION DIGITAL EN TIEMPO REAL."
    },
    {
      "clave": "35401-0003",
      "monto": 136157658.21,
      "partidas": 38,
      "descripcion": "SERVICIOS DE MANTENIMIENTO DE EQUIPO E INSTRUMENTAL MEDICO"
    },
    {
      "clave": "53101-1776",
      "monto": 49468794.58,
      "partidas": 1,
      "descripcion": "531.791.0066 RESONANCIA MAGNETICA DE 1.5 TESLAS UNIDAD DE IMAGEN POR. EQUIPO PARA OBTENER IMAGENES DIAGNOSTICAS DE CUERPO ENTERO MEDIANTE EL USO DE RADIOFRECUENCIAS Y CAMPOS MAGNETICOS. CON CAPACIDAD DE 1.5 TESLAS. MAGNETO SUPER CONDUCTOR. GRADIENTE POR EJE DE 30 MILITESLAS/MTS COMO MINIMO Y UN SLEW RATE 120 COMO MINIMO. CON METODO O TECNICA DE REDUCCION DE TIEMPO DE ADQUISICION O INCREMENTO DE LA VELOCIDAD DE ADQUISICION. SINCRONIZACION DE LA IMAGEN CON LA RESPIRACION Y ECG O DE MEDICIONES FISIOLOGICAS. TECNOLOGIA DE ADQUISICION O SISTEMA DE RF O TECNOLOGIA DE RF DE AL MENOS 8 CANALES. ESTACION DE ADQUISICION: MONITOR DE PANTALLA PLANA O LCD A COLOR DE 18 Š O MAYOR MATRIZ DE DESPLIEGUE DE 1024 X 1024 O MAYOR. QUEMADOR DE CD O DVD. DICOM PRINT QUERY/RETRIEVE STORAGE Y WORKLIST. FUNCIONES PARA RECONSTRUCCION. UPS PARA EL EQUIPO DE COMPUTO. PROGRAMAS: PAQUETE DE SPIN ECHO. PAQUETE DE RECUPERACION INVERSION: INVERSION RECOVERY. TECNICA DE DIFERENCIACION BASADA EN AGUA O GRASA O RECUPERACION POR SATURACION O TECNICA DE SATURACION GRASA. FAST SPIN ECHO O TURBO SPIN ECHO. PAQUETE PARA ANGIO RESONANCIA CON TIME OF FLIGHT (TOF) O INFLOW. MAGNETIZACION TRANSFER (MTC). PAQUETE DE CINE FLAIR O DARK FLUID. DIFUSION. PERFUSION. PROGRAMA DE REALCE DE CONTRASTE O CONSTRAST ENHANCEMENT. PROGRAMA PARA ANGIOGRAFIA PERIFERICA O VASCULAR PERIFERICA. PROGRAMA DE CORRECCION DE MOVIMIENTO. BOBINAS: SERAN DETERMINADAS O ELEGIDAS DE ACUERDO A LAS NECESIDADES OPERATIVAS DE LAS UNIDADES MEDICAS. MULTICANAL PARA COLUMNA CERVICAL - TORACICA - LUMBAR O CTL O COLUMNA COMPLETA. MULTICANAL DE CUERPO. MULTICANAL PARA CARDIOLOGIA. DE PROPOSITO GENERAL O FLEXIBLE O EXTREMIDADES. DE 8 CANALES PARA CABEZA. MULTICANAL PARA RODILLA. MULTICANAL PARA HOMBRO. MULTICANAL PARA MAMA. ENDOCAVITARIA O PROSTATA. MULTICANAL PARA NEUROVASCULAR O NV. JUEGO DE SUJETADORES AJUSTABLES O DE DIFERENTES TAMAÑOS. JAULA DE FARADAY O APANTALLAMIENTO MAGNETICO. SISTEMA DE ENFRIAMIENTO."
    },
    {
      "clave": "35401-0001",
      "monto": 47568411.95,
      "partidas": 2,
      "descripcion": "SERVICIOS DE INSTALACION DE EQUIPO E INSTRUMENTAL MEDICO"
    },
    {
      "clave": "53101-1842",
      "monto": 41702265.68,
      "partidas": 4,
      "descripcion": "531.924.0031 ULTRASONOGRAFO. EQUIPO DE ULTRASONIDO CON FINES DIAGNOSTICOS APLICABLE EN PACIENTES ADULTOS Y PEDIATRICOS. CON LAS SIGUIENTES CARACTERISTICAS SELECCIONABLES DE ACUERDO A LAS NECESIDADES DE LAS UNIDADES MEDICAS: MONITOR CON NIVELES DE GRIS TONOS DE COLOR. MODOS: B M/B M RANGO DINAMICO DEL SISTEMA EN DB. DOPPLER CONTINUO Y PULSADO DOPPLER COLOR. SISTEMA DE MAPEO A COLOR ANGIO POWER DOPPLER. IMAGENES ARMONICAS EN MODO B Y COLOR EN LAS VARIABLES: PENETRACION RESOLUCION O INVERSION DE PULSOS. PROGRAMA DE ECORREALZADORES O MEDIOS DE CONTRASTE. CON MEMORIA DE IMAGEN CUADRO POR CUADRO O CINE LOOP EN COLOR BLANCO Y NEGRO Y CINE ESPECTRAL. TECLADO ALFANUMERICO Y SALIDA DE VIDEO. CONVERTIDOR DE BARRIDO DE CANALES DE PROCESO DIGITAL DESDE LA FORMACION DEL HAZ. SELECCION DE PUNTOS FOCALES. ZOOM. CONTROL DE GANANCIA Y AJUSTE DE LA CURVA."
    },
    {
      "clave": "53101-1797",
      "monto": 31302600,
      "partidas": 1,
      "descripcion": "531.829.0276 SISTEMA DE PLANIFICACION DEL TRATAMIENTO DE RADIOTERAPIA. EQUIPO DE LOCALIZACION DE TUMORES LLAMADO SIMULADOR CON OPCION DE TOMOGRAFIA COMPUTADA UTIL PARA PLANEACION DE TRATAMIENTOS CON RADIACION Y CON TECNICA TRIDIMENSIONAL. SIMULADOR DE TRATAMIENTOS DE RADIOTERAPIA POR MEDIO DE TOMOGRAFIA AXIAL COMPUTARIZADA QUE PERMITE EL MARCADO DE LOS CAMPOS DE ENTRADA Y VISUALIZACION DE LOS MISMOS CON RESPECTO AL VOLUMEN TUMORAL CON LAS SIGUIENTES CARACTERISTICAS: DIAMETRO DEL TUNEL A TRAVES DEL CUAL SE EXAMINA AL PACIENTE NO MENOR DE 69 CM. ARREGLO CIRCULAR DE 600 FOTODIODOS ROTACION ± 360 ° EN EL ISOCENTRO GENERACION DE IMAGENES TRANSVERSAS Y CORONALES CON TIEMPO DE BARRIDO 360 ° DE 2.5 5 Y 10 SEG; ESPESOR DEL CORTE DE 2 A 10 MM CON PASOS DE 1 MM. PERMITE LA SIMULACION DE TRATAMIENTO DE 80 A 140 CM DE DISTANCIA FOCO ISOCENTRO (DFI) E INCLUYE SISTEMA DE ALINEACION DE PACIENTES A BASE DE RAYOS LASER."
    },
    {
      "clave": "53101-1417",
      "monto": 30913652,
      "partidas": 6,
      "descripcion": "531.191.0391 CARRO ROJO CON EQUIPO COMPLETO PARA REANIMACION CON DESFIBRILADOR-MONITOR-MARCAPASO. CARRO RODABLE CON SISTEMA DE FRENO PARA REALIZAR LAS MANIOBRAS DE REANIMACION CARDIOVERSION Y DESFIBRILACION CARDIOPULMONAR. CON COMPARTIMIENTOS PARA ACCESORIOS AL MENOS UNO DE ELLOS CON DISPOSITIVO DE SEGURIDAD. CON SOPORTE PARA LA TABLA DE COMPRESIONES CARDIACAS EXTERNAS Y PARA TANQUE DE OXIGENO. POSTE DE ALTURA AJUSTABLE PARA INFUSIONES. REANIMADOR PULMONAR. CON EQUIPO PARA INTUBACION ENDOTRAQUEAL. EQUIPO DE MONITOREO CONTINUO CON PANTALLA DE DESPLIEGUE DE AL MENOS ECG SATURACION DE OXIGENO Y FRECUENCIA CARDIACA. ENERGIA PARA DESCARGA EXTERNA SELECCIONABLE. ALARMAS VISIBLES Y AUDIBLES. INDICADORES. CAPACIDAD DE MEMORIA DE ACUERDO A LAS NECESIDADES. REGISTRO EN PAPEL TERMICO DE TENDENCIAS. PALETAS PEDIATRICAS Y ADULTO PARA DESFIBRILACION Y CARDIOVERSION. CON SELECTOR DE MODO. CON OPCION DE DESCARGA. CON SISTEMA DE SUSPENSION DE LA CARGA. CON SISTEMA PARA PROBAR DESCARGA. BATERIA RECARGABLE QUE GARANTICE AL MENOS 30 DESFIBRILACIONES A CARGA MAXIMA. CON TIEMPO DE CARGA COMPLETA DE LA BATERIA. CON ENERGIA BIFASICA. MARCAPASO EXTERNO TRANSCUTANEO INTERCONSTRUIDO. SELECCIONABLE EN INTERVALOS. FRECUENCIA DE MARCAPASO AJUSTABLE. ACTIVACION POR MODOS: FIJO O ASINCRONICO Y A DEMANDA O SINCRONICO."
    },
    {
      "clave": "53101-2326",
      "monto": 29715354.6,
      "partidas": 3,
      "descripcion": "535.701.0833 PINZA HALSTED MOSQUITO CURVA SIN DIENTES LONGITUD DE 120 A 130 MM."
    },
    {
      "clave": "53101-1447",
      "monto": 25960800,
      "partidas": 1,
      "descripcion": "531.254.0155 TOMOGRAFIA COMPUTARIZADA MULTICORTES DE 64 CORTES UNIDAD PARA. EQUIPO DE RAYOS X PARA REALIZAR ESTUDIOS TOMOGRAFICOS DE 64 CORTES POR GIRO O ROTACION DE DIFERENTES PARTES DEL CUERPO CON FINES DIAGNOSTICOS. CON UN TIEMPO DE EXPLORACION O RASTREO DE 0.4 SEG O MENOR EN UN GIRO O ROTACION DE 360 °. RESOLUCION TEMPORAL. GANTRY: ANGULACION DE ±30 GRADOS O MAYOR Y APERTURA DE 70 CENTIMETROS O MAYOR. MESA DE PACIENTE: CAPACIDAD DE CARGA DE LA MESA DE 180 KILOGRAMOS O MAYOR. SISTEMA DE POSICIONAMIENTO EN 2 EJES (VERTICAL Y HORIZONTAL). ALINEACION EN AL MENOS TRES EJES PARA DEFINIR EL PLANO DE CORTE. SISTEMA DE RAYOS X: TUBO DE RAYOS X CON CAPACIDAD DE ALMACENAMIENTO DE CALOR EN EL ANODO DE 7.5 MHU O MAYOR. CAPACIDAD DE DISIPACION DE CALOR. CON ESPESOR DE CORTE DE 0.625 MM O MENOR POR 64 CORTES EN HELICOIDAL. GENERADOR DE RAYOS X. CAMPO DE RASTREO O FOV DE 50 CM O MAYOR. PROCESAMIENTO DE IMAGENES: RECONSTRUCCION DE IMAGEN DE 16 IMAGENES POR SEGUNDO O MAYOR. RESOLUCION ESPACIAL. MATRIZ DE RECONSTRUCCION. MATRIZ DE DESPLIEGUE DE 1024X1024 O MAYOR. RECONSTRUCCION DE CONJUNTOS DE CORTES TRIDIMENSIONALES O 3D. RECONSTRUCCION DE VOLUMENES Y SUPERFICIES QUE PERMITA ROTACION ZOOM Y SEGMENTACION DE ORGANOS. CONSOLA DEL OPERADOR O ESTACION DE ADQUISICION: DOS MONITORES CON PANTALLA PLANA O LCD A COLOR DE ALTA RESOLUCION MATRIZ DE DESPLIEGUE DE 1024 X 1024 O MAYOR. CAPACIDAD DE ALMACENAJE DE IMAGENES EN DISCO DURO DE 140 GB O MAYOR. CAPACIDAD DE ALMACENAJE EXTERNO DE IMAGENES EN CD O DVD. CON PROGRAMAS PARA APLICACION DIAGNOSTICA: HERRAMIENTAS BASICAS PARA IMAGENES: ZOOM ROTACION IMAGEN ESPECULAR O EN ESPEJO ESCALA DE GRISES DISTANCIAS VOLUMENES. PROGRAMAS ESPECIFICOS PARA: REDUCCION DE DOSIS DE RADIACION PARA PEDIATRIA. MPR (PROYECCION MULTIPLANAR) EN TIEMPO REAL EN POR LO MENOS TRES PLANOS. DICOM PRINT QUERY/RETRIEVE STORAGE Y WORKLIST."
    },
    {
      "clave": "32401-0004",
      "monto": 19994205.12,
      "partidas": 8,
      "descripcion": "ARRENDAMIENTO DE EQUIPO MEDICO QUIRURGICO Y DE DIAGNOSTICO"
    },
    {
      "clave": "62201-0008",
      "monto": 17330379.02,
      "partidas": 1,
      "descripcion": "CONSTRUCCION DE EDIFICIOS DE SALUD"
    },
    {
      "clave": "53101-1539",
      "monto": 17150353.62,
      "partidas": 4,
      "descripcion": "531.341.2552 UNIDAD RADIOLOGICA Y FLUOROSCOPICA TRANSPORTABLE TIPO ARCO EN \"\"C . EQUIPO MOVIL DE RADIOLOGIA CON FLUOROSCOPIA PARA DIAGNOSTICO QUE UTILIZA UN BRAZO EN C Y APLICA TECNICAS ANALOGICAS O DE CONVERSION ANALOGICA A DIGITAL PARA LA CAPTURA PRESENTACION Y MANIPULACION DE IMAGENES PARA DIVERSAS APLICACIONES COMO LA EVALUACION VISUAL Y CUANTITATIVA DE LA ANATOMIA Y FUNCIONAMIENTO DE DIVERSAS ZONAS SELECCIONADAS. GENERADOR DE RAYOS X DE ALTA FRECUENCIA: POTENCIA DE 2 KW. O MAYOR KV. DE 40 O MENOR A 110 CORRIENTE EN FLUOROSCOPIA PULSADA O CONTINUA DE 7 MA. O MAYOR CORRIENTE DE RADIOGRAFIA DE 18 MA. O MAYOR. TUBO DE RAYOS X: UN PUNTO FOCAL DE 0.6 MM O MENOR O DOS PUNTOS FOCALES UNO DE 0.6 MM. O MENOR Y EL OTRO DE 1.4 MM. O MENOR CAPACIDAD DE ALMACENAMIENTO DE CALOR TERMICO EN EL ANODO DE 45 KHU O MAYOR ANODO FIJO O ROTATORIO. ARCO EN C: SID DE 90 CM. O MAYOR. DISTANCIA ENTRE FOCO E IMAGEN (SOURCE IMAGE DISTANCE) ROTACION DE +/- 110 GRADOS O MAYOR RECORRIDO HORIZONTAL RECORRIDO VERTICAL MOVIMIENTO PANORAMICO O LATERAL. CADENA DE IMAGEN DIGITAL O CAMARA DE VIDEO O CCD DE AL MENOS 1K X 1K O MAYOR A 12 BITS O MAYOR. DIAMETRO DEL INTENSIFICADOR DE IMAGEN DE 9Š O MAYOR DE 2 CAMPOS COMO MINIMO. ADQUISICION O ALMACENAMIENTO DE 6 IMAGENES O PULSOS/SEG. O MAYOR. CON CAPACIDAD DE ALMACENAMIENTO DE AL MENOS 3000 IMAGENES O 100 GB O MAYOR. ICOM PRINT Y DICOM SEND O STORE AL MENOS. CON UNIDAD DE GRABACION CD-R O DVD EN FORMATO DICOM. CONSOLA DE CONTROL MOVIL: DOS MONITORES DE 18Š O MAYOR CON RESOLUCION DE 1K X 1K TECLADO ALFA NUMERICO DE CONTROL DE PROCESOS."
    },
    {
      "clave": "53101-1730",
      "monto": 17121772.77,
      "partidas": 4,
      "descripcion": "531.632.0554 CENTRAL DE MONITOREO PARA MULTIPLES CAMAS. SISTEMA DE VIGILANCIA DE CONSTANTES VITALES CON LAS SIGUIENTES CARACTERISTICAS SELECCIONABLES DE ACUERDO A LAS NECESIDADES DE LAS UNIDADES MEDICAS: QUE OPERE POR MICROPROCESADOR FIJO QUE REQUIERE DE INSTALACION ELECTRICA E INTERCONEXION ENTRE LOS ELEMENTOS QUE LO INTEGRAN. PARA DOCUMENTAR LOS PARAMETROS CON SOFTWARE Y ALARMAS QUE REQUIERAN LAS UNIDADES MEDICAS. TECLADO ALFANUMERICO Y RATON. IMPRESORA LASER. MONITORES MODULARES DE CABECERA."
    },
    {
      "clave": "53101-0391",
      "monto": 15294062.76,
      "partidas": 7,
      "descripcion": "UNIDAD PARA ULTRASONOGRAFIA"
    },
    {
      "clave": "53101-1716",
      "monto": 15061466.07,
      "partidas": 9,
      "descripcion": "531.619.0403 MONITOR DE SIGNOS VITALES. EQUIPO INVASIVO Y NO INVASIVO QUE REGISTRA EN PANTALLA LAS CONSTANTES VITALES DEL PACIENTE CON FINES DIAGNOSTICOS Y TERAPEUTICOS. CON LAS SIGUIENTES CARACTERISTICAS SELECCIONABLES DE ACUERDO A LAS NECESIDADES DE LAS UNIDADES MEDICAS: MONITOR CONFIGURADO O MODULAR CON PANTALLA. CON CAPACIDAD PARA CONECTARSE A RED DE MONITOREO. PANTALLA PARA PRESENTACION DE CURVAS FISIOLOGICAS SIMULTANEAS E INFORMACION NUMERICA PARA LOS SIGUIENTES PARAMETROS: ELECTROCARDIOGRAMA EN DERIVACIONES SELECCIONABLES POR EL USUARIO. PRESENTACION DE UN CANAL DE ECG MINIMO EN PANTALLA. OXIMETRIA DE PULSO. FRECUENCIA RESPIRATORIA CON DESPLIEGUE DE SU CURVA. DESPLIEGUE NUMERICO DE: FRECUENCIA CARDIACA PRESION ARTERIAL NO INVASIVA SISTOLICA Y DIASTOLICA. MODOS PARA LA TOMA DE PRESION: MANUAL Y AUTOMATICA A DIFERENTES INTERVALOS DE TIEMPO. TEMPERATURA EN AL MENOS UN CANAL. FRECUENCIA DE PULSO. OPCION DE MONITOREO DE CAPNOGRAFIA A FUTURO. CANALES DE PRESION INVASIVA CADA UNO DEBE MEDIR Y MOSTRAR SIMULTANEAMENTE EN PANTALLA: PRESION SISTOLICA DIASTOLICA Y MEDIA. DEBE CONTAR CON FUNCION DE ETIQUETADO PARA CADA CANAL DE PRESION INVASIVA: PRESION ARTERIAL PRESION VENOSA CENTRAL ARTERIA PULMONAR COMO MINIMO. CON AJUSTE AUTOMATICO DE ESCALA Y ALARMAS. TENDENCIAS GRAFICAS Y NUMERICAS DE TODOS LOS PARAMETROS SELECCIONABLES POR EL USUARIO. USO PARA ADULTO Y PEDIATRICO. CON BATERIA INTERNA RECARGABLE CON CARGADOR INTEGRADO E INDICADOR DE BAJO NIVEL EN PANTALLA. ALARMAS AUDIBLES Y VISIBLES CON FUNCION QUE PERMITA REVISAR Y MODIFICAR LOS LIMITES SUPERIOR E INFERIOR DE LOS SIGUIENTES PARAMETROS: SATURACION DE OXIGENO FRECUENCIA CARDIACA PRESION ARTERIAL NO INVASIVA SISTOLICA Y DIASTOLICA TEMPERATURA FRECUENCIA RESPIRATORIA Y ALARMA DE APNEA PRESION INVASIVA SISTOLICA DIASTOLICA Y MEDIA. QUE IDENTIFIQUE NIVELES DE PRIORIDAD EN LAS ALTERACIONES FISIOLOGICAS. CON SILENCIADOR DE ALARMAS. TODAS LAS FUNCIONES DEBEN SER ACCESADAS MEDIANTE TECLAS DE MEMBRANA SENSIBLES AL TACTO O PERILLA SELECTORA EN EL GABINETE DEL MONITOR. TECLADO MENUS Y MENSAJES EN PANTALLA EN ESPAÑOL. REGISTRADOR. DISEÑO QUE PERMITA SER USADO COMO MONITOR DE TRANSPORTE Y MONITOR DE CABECERA."
    },
    {
      "clave": "53101-1691",
      "monto": 14432720,
      "partidas": 1,
      "descripcion": "531.611.0033 MASTOGRAFO DIGITAL CON ESTEREOTAXIA Y TOMOSINTESIS. EQUIPO FIJO PARA REALIZAR ESTUDIOS RADIOLOGICOS DE MAMA CON ADQUISICION DE IMAGEN DIGITAL DE CAMPO COMPLETO CON TOMOSINTESIS Y ESTUDIOS DE BIOPSIA CON FINES DIAGNOSTICOS."
    },
    {
      "clave": "61600-0107",
      "monto": 13843969.31,
      "partidas": 1,
      "descripcion": "OTRA CONSTRUCCION DE INGENIERIA CIVIL"
    },
    {
      "clave": "33901-0001",
      "monto": 12100981.86,
      "partidas": 1,
      "descripcion": "ESTUDIOS E INVESTIGACIONES"
    },
    {
      "clave": "53101-1537",
      "monto": 11198891.92,
      "partidas": 1,
      "descripcion": "531.341.2529 UNIDAD RADIOLOGICA Y FLUOROSCOPICA CON TELEMANDO Y ARCO EN ŠCŠ CON MESA BASCULABLE. SISTEMA DE RAYOS \"\"X\"\" MULTIPROPOSITO PARA APLICACIONES RADIOGRAFICAS FLUOROSCOPICAS ANGIOGRAFICAS E INTERVENCIONALES. MESA DE RAYOS \"\"X\"\" TELECOMANDADA CON BRAZO TIPO \"\"C\"\" PARA MONTAJE DEL TUBO E INTENSIFICADOR DE IMAGEN CON COBERTURA DE PACIENTE DE AL MENOS 120 CM. CON SISTEMA DE PROTECCION DE CHOQUES. GENERADOR GENERADOR TRIFASICO DE RAYOS \"\"X\"\" DE ALTA FRECUENCIA CONTROLADO MEDIANTE MICROPROCESADORES Y SISTEMA DE PROTECCION DE ERROR CON PROTECCION CONTRA SOBRECARGA DEL TUBO POTENCIA DE 80 KW COMO MINIMO Y AL MENOS 1000 MA DE CORRIENTE MAXIMA TIEMPO DE EXPOSICION DE 2 MS O MENOR CON AJUSTE DE VOLTAJE ENTRE 40 KW O MENOR HASTA 125 KW O MAYOR CONTROL AUTOMATICO DE EXPOSICION CONTROL AUTOMATICO DE BRILLO. CON CONSOLA DE CONTROL DE MANDO CERCANO Y TELEMANDO. TUBO DE RAYOS \"\"X\"\" 9000 R.P.M. COMO MINIMO CON PUNTO FOCAL FINO NO MAYOR A 0.6 MM Y PUNTO FOCAL GRUESO NO MAYOR A 1.2 MM. CON CAPACIDAD DE ACUMULACION DE CALOR EN EL ANODO DE AL MENOS 300 KHU. MESA PACIENTE TELEMANDO BASCULABLE 85°/ -45° SUSPENDIDA DE UN SOLO PUNTO Y CONO PARA COMPRESION MANEJADO A CONTROL REMOTO ALTURA DE LA MESA VARIABLE DESDE 90 CM O MENOR HASTA 120 CM. O MAYOR DESPLAZAMIENTO LATERAL DEL TABLERO DE LA MESA DE AL MENOS + 12.5 CM. Y 20 CM O DESPLAZAMIENTO LATERAL DEL BRAZO EN C DE AL MENOS + 13 CM Y DE - 15 CM. CARACTERISTICAS DEL BRAZO DESPLAZAMIENTO LONGITUDINAL DEL BRAZO C DE AL MENOS 125 CM. CON VELOCIDAD CONTINUAMENTE VARIABLE ROTACION DEL BRAZO EN C DE 90 ° LAO COMO MINIMO HASTA AL MENOS 40 ° RAO ANGULACION CRANEO - CAUDAL DEL BRAZO EN C DE POR LO MENOS ± 30 ° EN POSICION A.P Y P.A. CON VELOCIDAD VARIABLE. INTENSIFICADOR DE IMAGEN DE 35 CM O MAYOR CON AL MENOS 3 CAMPOS 35/25/17 CM O MAYOR Y SISTEMA DE DETECCION DE COLISION INCORPORADO DOS MONITORES DE T.V. CON LAS SIGUIENTES CARACTERISTICAS: ALTA RESOLUCION DE 1049 AJUSTE AUTOMATICO DE BRILLO PANTALLA DE 50 CM O MAYOR CON SUSPENSION AL TECHO. CON SISTEMA DIGITAL DE ADQUISICION DE IMAGENES EN 1024 X 1024 PIXELES Y 10 BITS QUE CUENTE CON: AL MENOS 64 MBYTES DE MEMORIA RAM O EN DISCO ADQUISICION DE 7.5 IMAGENES POR SEGUNDO O MAYOR DISCO OPTICO MAGNETICO CON CAPACIDAD MINIMA DE 600 MB O MAYOR SUSTRACCION DIGITAL EN TIEMPO REAL DESPLIEGUE DE 16 IMAGENES. CONTROL REMOTO PARA SELECCION DE IMAGENES CONSOLA CON TECLADO ALFANUMERICO Y MONITOR DE 53 CM O MAYOR Y 1000 LINEAS O MAYOR CON PROGRAMAS PARA PROCESAMIENTO DE LA IMAGEN QUE AL MENOS PERMITAN EL REALCE DE BORDES ADAPTACION DEL BRILLO RE-ENMASCARAMIENTO CORRECCION EN TIEMPO REAL O FILTRO PARA CORRECCIONES DINAMICAS DE LOS ARTEFACTOS POR MOVIMIENTO ZOOM Y ANOTACION DE TEXTO."
    }
  ],
  "recentProcedures": [
    {
      "numero": "aa-50-gyr-050gyr057-n-85-2026",
      "titulo": "MANTENIMIENTO PREVENTIVO Y CORRECTIVO A INYECTORES",
      "estatus": "ADJUDICADO",
      "fecha_publicacion": "2026-07-29T14:33:35+00:00"
    },
    {
      "numero": "aa-56-ayo-056ayo954-n-127-2026",
      "titulo": "SERVICIO DE MANTENIMIENTO PREVENTIVO Y/O CORRECTIVO PARA EQUIPO MÉDICO DE ALTA T",
      "estatus": "ADJUDICADO",
      "fecha_publicacion": "2026-06-12T09:18:35+00:00"
    },
    {
      "numero": "ia-50-gyr-050gyr057-n-51-2026",
      "titulo": "ARRENDAMIENTO DE EQUIPO MEDICO",
      "estatus": "ADJUDICADO",
      "fecha_publicacion": "2026-05-07T17:35:36+00:00"
    },
    {
      "numero": "aa-56-ayo-056ayo954-i-80-2026",
      "titulo": "ADQUISICIÓN DE BIENES PARA EL PROYECTO DE INVERSIÓN DENOMINADO CONCLUSIÓN DEL HG",
      "estatus": "ADJUDICADO",
      "fecha_publicacion": "2026-04-27T13:58:48+00:00"
    },
    {
      "numero": "la-50-gyr-050gyr057-n-34-2026",
      "titulo": "SERVICIO DE MANTENIMIENTO PREVENTIVO Y CORRECTIVO A EQUIPO MÉDICO",
      "estatus": "ADJUDICADO",
      "fecha_publicacion": "2026-03-26T16:44:49+00:00"
    },
    {
      "numero": "la-50-gyr-050gyr015-n-92-2026",
      "titulo": "ARRENDAMIENTO DE EQUIPOS MÉDICOS PARA LOS HOSPITALES GENERALES DE ZONA",
      "estatus": "ADJUDICADO PARCIAL",
      "fecha_publicacion": "2026-03-13T11:27:56+00:00"
    },
    {
      "numero": "la-50-gyr-050gyr030-n-59-2026",
      "titulo": "LA-050GYR030-N-59-2026 - ARRENDAMIENTO DE EQUIPO MÉDICO PARA LOS HOSPITALES HGZ",
      "estatus": "ADJUDICADO PARCIAL",
      "fecha_publicacion": "2026-03-10T12:47:36+00:00"
    },
    {
      "numero": "aa-81-019-922010998-n-5-2026",
      "titulo": "SESEQ ADF 001 2026 PARTIDA PRESUPUESTAL 5354011",
      "estatus": "ADJUDICADO",
      "fecha_publicacion": "2026-02-23T09:28:41+00:00"
    },
    {
      "numero": "la-12-nde-012nde001-n-9-2026",
      "titulo": "SERVICIO PARA LA OBTENCIÓN, RESGUARDO Y ENTREGA DE IMÁGENES DIAGNÓSTICAS",
      "estatus": "ADJUDICADO",
      "fecha_publicacion": "2026-02-13T15:46:21+00:00"
    },
    {
      "numero": "la-50-gyr-050gyr055-t-34-2026",
      "titulo": "ADQUISICIÓN DE LOS GRUPOS DE SUMINISTRO 379 CONSUMIBLES DE EQUIPOS MÉDICOS Y DE",
      "estatus": "ADJUDICADO PARCIAL",
      "fecha_publicacion": "2026-02-10T16:57:50+00:00"
    },
    {
      "numero": "la-47-ayo-047ayo954-t-46-2026",
      "titulo": "ADQUISICIÓN DE BIENES PARA EL PROGRAMA DE INVERSIÓN DENOMINADO PROGRAMA NACIONAL",
      "estatus": "ADJUDICADO PARCIAL",
      "fecha_publicacion": "2026-01-28T20:31:56+00:00"
    },
    {
      "numero": "aa-47-ayo-047ayo954-i-40-2026",
      "titulo": "ADQUISICIÓN DE BIENES PARA EL PROGRAMA DE INVERSIÓN DENOMINADO SUSTITUCIÓN DE EQ",
      "estatus": "ADJUDICADO",
      "fecha_publicacion": "2026-01-14T10:32:03+00:00"
    },
    {
      "numero": "aa-47-ayo-047ayo954-i-33-2026",
      "titulo": "ADQUISICIÓN DE BIENES PARA EL PROGRAMA DE INVERSIÓN DENOMINADO SUSTITUCIÓN DEL E",
      "estatus": "ADJUDICADO",
      "fecha_publicacion": "2026-01-05T20:14:42+00:00"
    },
    {
      "numero": "la-07-110-007000999-n-51-2026",
      "titulo": "ACTUALIZACION SV. DE SOPORTE TECNICO AL HADWARE Y SOFTWARE PARA EL SIST. PACS",
      "estatus": "ADJUDICADO",
      "fecha_publicacion": "2025-11-19T15:39:25+00:00"
    },
    {
      "numero": "aa-51-gyn-051gyn020-t-15-2025",
      "titulo": "PARTIDAS DESIERTAS LA-51-GYN-051GYN020-T-10-2025 ECENTRO MEDICO 20 DE NOV",
      "estatus": "ADJUDICADO PARCIAL",
      "fecha_publicacion": "2025-10-31T15:58:36+00:00"
    }
  ],
  "amountByYear": {
    "2023": {
      "monto": 642561999.25,
      "contratos": 59
    },
    "2024": {
      "monto": 256549381.35,
      "contratos": 37
    },
    "2025": {
      "monto": 42657415.36,
      "contratos": 21
    },
    "2026": {
      "monto": 257024221.39,
      "contratos": 15
    }
  },
  "firstContractAt": "2023-01-12T00:00:00.000Z",
  "lastContractAt": "2026-07-29T00:00:00.000Z",
  "entityType": "moral",
  "distinctMoralRfcs": 0,
  "isAmbiguous": false,
  "isIndexable": true,
  "noindexReason": null,
  "contentHash": "9c254f057ff105a20b956a54898667c902a26b96b1f47aaf1e84bc34dad0ca50",
  "refreshedAt": "2026-08-18T04:39:58.645Z",
  "snapshot": {
    "snapshot_id": "9c254f057ff105a20b956a54898667c902a26b96b1f47aaf1e84bc34dad0ca50",
    "as_of": "2026-08-18T04:39:58.645Z",
    "procedures": {
      "total": 124,
      "shown": 15,
      "complete": false
    }
  }
}