{
  "html_url": "https://licitia.com.mx/proveedor/med-iq-supplies",
  "canonical": "https://licitia.com.mx/proveedor/med-iq-supplies",
  "id": "1061267",
  "slug": "med-iq-supplies",
  "displayName": "MED IQ SUPPLIES SA DE CV",
  "normalizedName": "med-iq-supplies",
  "aliasCount": 1,
  "totalContracts": 5,
  "totalProcedures": 5,
  "totalAwardedAmount": "174017045.98",
  "minAmount": "7979687.56",
  "maxAmount": "97935401.2",
  "medianAmount": "25667768.94",
  "suspectContracts": 0,
  "foreignContracts": 0,
  "foreignTotals": null,
  "distinctBuyers": 2,
  "distinctStates": 2,
  "distinctCucop": 8,
  "topBuyers": [
    {
      "slug": "issste",
      "monto": 166037358.42,
      "nombre": "INSTITUTO DE SEGURIDAD Y SERVICIOS SOCIALES DE LOS TRABAJADORES DEL ESTADO",
      "contratos": 4
    },
    {
      "slug": "imss-bienestar-056ayo",
      "monto": 7979687.56,
      "nombre": "SERVICIOS DE SALUD DEL INSTITUTO MEXICANO DEL SEGURO SOCIAL PARA EL BIENESTAR (IMSS-BIENESTAR)",
      "contratos": 1
    }
  ],
  "topCucop": [
    {
      "clave": "53101-0066",
      "monto": 132029835.37,
      "partidas": 2,
      "descripcion": "CAMA CLINICA (EQUIPO MEDICO QUIRURGICO)"
    },
    {
      "clave": "53101-1532",
      "monto": 11737022.91,
      "partidas": 1,
      "descripcion": "531.341.2479 UNIDAD RADIOLOGICA PORTATIL. EQUIPO DE RAYOS \"\"X\"\" MOVIL CON LAS SIGUIENTES CARACTERISTICAS APLICABLES SEGUN NECESIDADES DIAGNOSTICAS: GENERADOR DE RAYOS \"\"X\"\" DE ALTA FRECUENCIA O TIPO CONVERTIDOR POTENCIA AJUSTE DE KILOVOLTAJE CORRIENTE TIEMPO DE EXPOSICION AJUSTE DE MAS. CONTROLES E INDICADORES DE PARAMETROS DE EXPOSICION CON DESPLIEGUE EN PANTALLA DIGITAL. TUBO DE RAYOS \"\"X : CON ANODO ROTATORIO CON AL MENOS UN PUNTO FOCAL CON CAPACIDAD TERMICA DE ALMACENAMIENTO DEL ANODO. COLIMADOR MANUAL CON CENTRADOR DE HAZ LUMINOSO. PORTATUBO TIPO TELESCOPICO O CONTRAPESADO: GIRATORIO ALTURA MAXIMA DEL FOCO AL PISO GIRO DEL TUBO. CAJON GUARDACHASISES. RODAMIENTO CON SISTEMA DE FRENADO. PESO. CON O SIN BATERIA RECARGABLE PARA EL DISPARO. MANDIL EMPLOMADO."
    },
    {
      "clave": "33903-0012",
      "monto": 7979687.56,
      "partidas": 1,
      "descripcion": "SERVICIOS INTEGRALES"
    },
    {
      "clave": "53101-1858",
      "monto": 7803207.71,
      "partidas": 2,
      "descripcion": "531.941.0279 VENTILADOR DE TRASLADO PEDIATRICO-ADULTO. EQUIPO ELECTROMECANICO PORTATIL CONTROLADO POR MICROPROCESADOR CON BATERIA INTERNA DE SOPORTE DE VIDA PARA APOYO VENTILATORIO EN PACIENTES PEDIATRICOS Y ADULTOS QUE TIENEN COMPROMETIDA LA FUNCION RESPIRATORIA Y REQUIEREN TRASLADOS INTRA O EXTRA-HOSPITALARIOS EN TODO TIPO DE AMBULANCIAS O EN SITIOS DE EMERGENCIA. CON PANTALLA MONOCROMATICA O A COLOR QUE MUESTRE GRAFICAS DATOS NUMERICOS Y ALARMAS. PESO NO MAYOR DE 7 KG. PANTALLA INTERCONSTRUIDA: TIPO LCD LCD-TFT TFT O LED. A COLOR O MONOCROMATICA. TAMAÑO DE 5.7\"\" O MAYOR. CONFIGURABLE POR EL USUARIO. CARACTERISTICAS GENERALES: MEZCLADOR DE AIRE-OXIGENO INTERNO O INTEGRADO Y DE LA MISMA MARCA. MONITOREO DE FIO2 INTERNO. SENSOR DE FLUJO REUSABLE. COMPENSACION AUTOMATICA DE LA ALTITUD. DURACION DE LA BATERIA DE RESPALDO (EXTERNA Y/O INTERNA) DE 4 HORAS COMO MINIMO. TIEMPO DE RECARGA DE LA BATERIA DE 5 HORAS COMO MAXIMO. ASA Y SOPORTE PARA CAMILLA. TODO EL SISTEMA EN IDIOMA ESPAÑOL. PERILLA SELECTORA PARA EL AJUSTE DE LOS VALORES DE TODOS LOS PARAMETROS DE CONTROL. CONTROL DE PARAMETROS DE: VOLUMEN CORRIENTE QUE CUBRA EL RANGO DE 50 A 2000 ML. FLUJO INSPIRATORIO DE 100 L/MIN O MAYOR. PRESION INSPIRATORIA QUE CUBRA EL RANGO DE 5 A 55 CMH2O. FRECUENCIA RESPIRATORIA QUE CUBRA EL RANGO DE 2 A 60 RESPIRACIONES POR MINUTO. TIEMPO INSPIRATORIO QUE CUBRA EL RANGO DE 0.3 A 3 SEGUNDOS. FIO2 QUE CUBRA EL RANGO DE 40 A 100 %. PEEP/CPAP QUE CUBRA EL RANGO DE 0 A 20 CMH2O. PRESION SOPORTE (PSV) PRESION ASISTIDA O ASB QUE CUBRA EL RANGO DE 0 A 35 CMH2O. CON OPCION MESETA INSPIRATORIA DE PLATEU O PAUSA INSPIRATORIA. RESPIRACION MANUAL. SENSIBILIDAD ESPIRATORIA O TERMINACION DE LA FASE INSPIRATORIA. AJUSTE DE RAMPA DE PRESION RISE TIME RETARDO INSPIRATORIO RAMPA O INCREMENTO DE LA PENDIENTE DE PRESION. 100% DE O2 DURANTE 2 MINUTOS O MAS. MECANISMO DE DISPARO O TRIGGER POR FLUJO Y/O POR PRESION. MODOS VENTILATORIOS: VENTILACION ASISTO CONTROLADA Y SIMV CONTROLADA POR VOLUMEN. VENTILACION ASISTO CONTROLADA Y SIMV CONTROLADA POR PRESION. VENTILACION MANDATORIA INTERMITENTE (SIMV) CON PRESION SOPORTE. PRESION SOPORTE (PSV) O PRESION ASISTIDA O ASB. CPAP O ESPONTANEO CON LINEA DE BASE ELEVADA. RESPALDO EN CASO DE APNEA DE ACUERDO AL MODO VENTILATORIO POR VOLUMEN O PRESION. VENTILACION NO INVASIVA. PARAMETROS MONITORIZADOS: PRESION INSPIRATORIA PICO O MAXIMA. PRESION MEDIA EN VIAS AEREAS. PRESION DE MESETA O PLATEAU. VOLUMEN CORRIENTE INSPIRADO Y ESPIRADO. VOLUMEN MINUTO. PEEP. FRECUENCIA RESPIRATORIA. RELACION I:E. TIEMPO INSPIRATORIO (S). FIO2. CALCULO DE DISTENSIBILIDAD Y/O RESISTENCIA. INDICADOR DE HORAS DE USO. INDICADOR DEL ESTADO DE LA BATERIA DE RESPALDO EN USO. DESPLIEGUE DE AL MENOS 2 DE LAS 3 CURVAS DE VENTILACION DE FORMA SIMULTANEA: VOLUMEN-TIEMPO; FLUJO-TIEMPO; PRESION-TIEMPO. ALARMAS: AUDIBLES Y VISUALES. PRESION INSPIRATORIA ALTA Y BAJA. PEEP BAJO O DESCONEXION DEL PACIENTE. APNEA. VOLUMEN MINUTO Y/O CORRIENTE (ALTO Y BAJO). FRECUENCIA RESPIRATORIA ALTA. FIO2 ALTA Y BAJA. BAJA PRESION DEL SUMINISTRO DE GASES. FALLA DE ALIMENTACION ELECTRICA. BATERIA BAJA. VENTILADOR INOPERANTE FALLA DEL VENTILADOR FALLA TECNICA O FALLA DE CICLO. SILENCIO DE ALARMA. PROGRAMACION AUTOMATICA DE ALARMAS. ACCESORIOS INCLUIDOS: MANGUERA PARA SUMINISTRO DE GAS DE ACUERDO AL CODIGO AMERICANO DE COLORES: O2 - VERDE. DOS CIRCUITOS DE PACIENTE REUSABLES LIBRES DE LATEX (INCLUYE ADAPTADORES CONECTORES Y TRAMPAS DE AGUA). O DIEZ CIRCUITOS DESECHABLES LIBRES DE LATEX PARA PACIENTE ADULTO Y/O PEDIATRICO. DOS SENSORES DE FLUJO DE ADULTO Y DOS SENSORES DE FLUJO PEDIATRICO EN CASO DE QUE LA TECNOLOGIA ASI LO REQUIERA. DIEZ NARICES ARTIFICIALES / FILTRO HME (INTERCAMBIADOR DE HUMEDAD Y TEMPERATURA) PARA USO PEDIATRICO / ADULTO DE ACUERDO A LOS REQUERIMIENTOS DE LA UNIDAD. DIEZ MASCARILLAS DESECHABLES LIBRES DE LATEX PARA VENTILACION NO INVASIVA. TAMAÑO DE ACUERDO A LOS REQUERIMIENTOS DE LA UNIDAD."
    },
    {
      "clave": "53101-1502",
      "monto": 4505795.77,
      "partidas": 1,
      "descripcion": "531.328.0221 UNIDAD DE ELECTROCIRUGIA AVANZADA CON SELLADO O TERMOFUSION DE VASOS. EQUIPO CON GENERADOR QUE CREA UNA CORRIENTE DE ALTA FRECUENCIA A FIN DE GENERAR CALOR EN LOS TEJIDOS PARA CORTAR Y COAGULAR DURANTE LA CIRUGIA INCLUYENDO SALIDAS DE ENERGIA MONOPOLAR BIPOLAR Y SELLADO O TERMOFUSION DE VASOS (BIPOLAR MODIFICADO). UNIDAD DE ELECTROCIRUGIA CON SALIDA MONOPOLAR DE CORTE PURO CON POTENCIA DE SALIDA DE 300 WATTS O MAYOR; MEZCLA O BLEND CON POTENCIA MINIMA DE 200 WATTS; CON AL MENOS DOS MODOS DE COAGULACION MONOPOLAR CON POTENCIA MINIMA DE 110 WATTS. SALIDA BIPOLAR: COAGULACION CON POTENCIA DE SALIDA DE 70 WATTS O MAYOR Y CONTROL INDEPENDIENTE PARA SELECCION DE POTENCIA EN MODO BIPOLAR. SALIDA PARA SELLADO O TERMOFUSION DE VASOS (BIPOLAR MODIFICADO) CON SALIDA INDEPENDIENTE MEMORIA INTERNA PARA RECONOCIMIENTO DE LOS INSTRUMENTOS; FORMACION DE SELLOS QUE SOPORTAN 400 MMHG O MAS SIN DEPENDER DE TROMBOS; CAPACIDAD DE MEDIR LA IMPEDANCIA DE LOS TEJIDOS Y HACER UNA SELECCION CONTINUA DEL NIVEL DE ENERGIA DE SALIDA TRABAJA DE FORMA DINAMICA; CAPACIDAD DE SELLADO DE VASOS DE HASTA 7 MM DE DIAMETRO GENERANDO DAÑO TERMICO LATERAL MENOR DE 3 MM; ALARMA AUDIBLE DE FINALIZACION DE SELLADO DE VASOS. PANTALLA LCD O TECNOLOGIA SUPERIOR. DESPLIEGUE NUMERICO Y DE FUNCIONES EN PANTALLA DE: POTENCIA DE SALIDA MONOPOLAR POTENCIA DE SALIDA BIPOLAR INDICADOR DE ACTIVACION DE SELLADO DE VASOS (BIPOLAR MODIFICADO) INDICADOR DEL MODO EN USO INDICADOR DE MONITORIZACION DE LA CALIDAD DEL CONTACTO DEL ELECTRODO DE RETORNO INDICADOR DE ERRORES. ACTIVACION DE LA UNIDAD POR MEDIO DEL INSTRUMENTO Y/O PEDAL EN SALIDA MONOPOLAR POR MEDIO DEL INSTRUMENTO Y/O PEDAL EN SALIDA BIPOLAR POR MEDIO DEL INSTRUMENTO Y/O PEDAL EN SALIDA DE SELLADO DE VASOS (BIPOLAR MODIFICADO). INDICADORES AUDIBLES Y VISIBLES AL ACCIONAR CUALQUIERA DE LOS MODOS DEL EQUIPO. ALARMAS AUDIBLES Y VISIBLES DE: FALLA EN ALGUNO DE LOS MODOS FALSO CONTACTO DEL ELECTRODO DE RETORNO CON EL PACIENTE O QUE NO ESTE CONECTADO A LA UNIDAD INTERRUPCION DEL CICLO DE SELLADO DE VASOS FALLAS DURANTE LA FORMACION DEL SELLO DE LOS VASOS. PEDAL BIPOLAR. PEDAL MONOPOLAR. CARRO PARA SOPORTE Y TRASLADO DEL EQUIPO. PINZA BIPOLAR RECTA Y DE BAYONETA."
    },
    {
      "clave": "53101-1861",
      "monto": 4061786.4,
      "partidas": 1,
      "descripcion": "531.941.1012 VENTILADOR DE ALTA FRECUENCIA OSCILATORIA PEDIATRICO/NEONATAL CON MODO CONVENCIONAL. EQUIPO ELECTROMECANICO CONTROLADO POR MICROPROCESADOR DE SOPORTE DE VIDA PARA APOYO EN MODO DE VENTILACION DE ALTA FRECUENCIA OSCILATORIA Y CONVENCIONAL PARA PACIENTES NEONATOS Y PEDIATRICOS CON COMPROMISO DE LA FUNCION RESPIRATORIA. PANTALLA INTERCONSTRUIDA: TIPO LCD LCD-TFT TFT O LED. A COLOR. SENSIBLE AL TACTO O TOUCH SCREEN. TAMAÑO DE 10.4\"\" O MAYOR. CARACTERISTICAS DEL MODO DE ALTA FRECUENCIA OSCILATORIA: CONTROLES Y AJUSTES DE (VENTILACION DE ALTA FRECUENCIA): PRESION MEDIA EN LAS VIAS AEREAS QUE CUBRA EL RANGO DE 5 A 25 CMH2O O MBAR. FRECUENCIA RESPIRATORIA QUE CUBRA EL RANGO DE 5 A 15 HZ. FIO2 QUE CUBRA EL RANGO DE 21 A 100 %. AMPLITUD QUE CUBRA EL RANGO DE 5 A 80 (EN CMH2O O MBAR. O PORCENTAJE DE LA PRESION MEDIA). MODOS VENTILATORIOS: HFV. HFV MAS MODO CONVENCIONAL O VOLUMEN GARANTIZADO. PARAMETROS MONITORIZADOS: PRESION MEDIA EN LAS VIAS AEREAS (CMH2O O MBAR). FRECUENCIA RESPIRATORIA (HZ). FIO2 (%). AMPLITUD (CMH2O O MBAR). VOLUMEN MINUTO (L/MIN). VOLUMEN CORRIENTE (ML). DCO2 (ML2/S). ALARMAS: AUDIBLES Y VISUALES AMBAS PRIORIZADAS EN TRES NIVELES. PRESION MEDIA (ALTA Y BAJA). FIO2 (ALTA Y BAJA). BAJA PRESION DEL SUMINISTRO DE GASES. FALTA DE ALIMENTACION ELECTRICA. VENTILADOR INOPERANTE O FALLA DEL VENTILADOR. VOLUMEN MINUTO ALTO Y BAJO. CARACTERISTICAS DEL MODO CONVENCIONAL: CONTROLES Y AJUSTES DE (VENTILACION CONVENCIONAL): PRESION INSPIRATORIA QUE CUBRA EL RANGO DE 10 A 65 CMH2O O MBAR. FRECUENCIA RESPIRATORIA QUE CUBRA EL RANGO DE 20 A 150 RESPIRACIONES POR MINUTO. TIEMPO INSPIRATORIO QUE CUBRA EL RANGO DE 0.1 A 2 SEGUNDOS. FIO2 QUE CUBRA EL RANGO DE 21 A 100 %. VOLUMEN CORRIENTE QUE CUBRA EL RANGO DE 2 A 100 ML. PEEP/CPAP QUE CUBRA EL RANGO DE 0 A 20 CMH2O O BAR. PRESION SOPORTE (PSV) PRESION ASISTIDA O ASB (CMH2O O MBAR) O PORCENTAJE DEL FLUJO PICO QUE CUBRA EL RANGO DE 10 O MENOR. O 50% A 80 O MAYOR (EN CMH2O O MBAR. O PORCENTAJE DE LA PRESION MEDIA). CON VOLUMEN GARANTIZADO OBJETIVO O PRVC (ML). RESPIRACION MANUAL. BIAS FLOW FLUJO BASE O CONTINUO. MECANISMO DE DISPARO O TRIGGER POR FLUJO. SENSIBILIDAD ESPIRATORIA TERMINACION DE LA FASE INSPIRATORIA O DE FINALIZACION POR FLUJO. MODOS VENTILATORIOS: VENTILACION ASISTO CONTROLADA PTV IPPV O SIPPV Y SIMV CONTROLADA. VENTILACION MANDATORIA INTERMITENTE (SIMV) CON PRESION SOPORTE. PRESION SOPORTE (PSV) O PRESION ASISTIDA O ASB. CPAP O ESPONTANEO CON LINEA DE BASE ELEVADA. VENTILACION NO INVASIVA O CPAP NASAL. PARAMETROS MONITORIZADOS: PRESION INSPIRATORIA PICO O MAXIMA. PRESION MEDIA EN VIAS AEREAS. VOLUMEN CORRIENTE ESPIRADO. VOLUMEN MINUTO. PEEP. FRECUENCIA RESPIRATORIA. RELACION I:E. TIEMPO INSPIRATORIO Y ESPIRATORIO. FIO2. CALCULO DE DISTENSIBILIDAD O COMPLIANCE. CALCULO DE LA RESISTENCIA. DESPLIEGUE DE AL MENOS DOS LAZOS O LOOPS. CAPACIDAD DE ALMACENAR EVENTOS RELACIONADOS CON LOS PARAMETROS VENTILATORIOS SELECCIONADOS Y TENDENCIAS DE AL MENOS 24 HORAS. DESPLIEGUE DE AL MENOS 2 DE LAS 3 CURVAS DE VENTILACION DE FORMA SIMULTANEA: VOLUMEN-TIEMPO; FLUJO-TIEMPO; PRESION-TIEMPO. ALARMAS: AUDIBLES Y VISUALES AMBAS PRIORIZADAS EN TRES NIVELES. PRESION INSPIRATORIA ALTA Y BAJA. PEEP BAJO O DESCONEXION DEL PACIENTE O FUGA. APNEA. VOLUMEN MINUTO Y/O CORRIENTE (ALTO Y BAJO). FRECUENCIA RESPIRATORIA ALTA. FIO2 ALTA Y BAJA. BAJA PRESION O PERDIDA DEL SUMINISTRO DE GASES. FALLA DE ALIMENTACION ELECTRICA. BATERIA BAJA. VENTILADOR INOPERANTE FALLA DEL VENTILADOR FALLA TECNICA O FALLA DE CICLO. SILENCIO DE ALARMA. PROGRAMACION DE ALARMAS. CARACTERISTICAS GENERALES: MEZCLADOR DE AIRE-OXIGENO INTERNO. MONITOREO DE FIO2 INTERNO. SENSOR DE FLUJO REUSABLE. HUMIDIFICADOR SERVOCONTROLADO PARA USO CON CALENTADOR DE RAMA INSPIRATORIA O DUAL; CON SENSOR DE TEMPERATURA SENCILLO O DUAL Y SOPORTE AL VENTILADOR. TODO EL SISTEMA EN IDIOMA ESPAÑOL. CON SISTEMA DE COMPENSACION DE FUGAS. PERILLA SELECTORA FISICA O EN PANTALLA TACTIL PARA EL AJUSTE DE LOS VALORES DE TODOS LOS PARAMETROS DE CONTROL."
    },
    {
      "clave": "53101-1547",
      "monto": 3882691.12,
      "partidas": 1,
      "descripcion": "531.350.0075 LÁSER QUIRÚRGICO DE DIÓXIDO DE CARBONO CO2. EQUIPO DE RAYO LÁSER PARA MANIOBRA QUIRÚRGICA DE CORTE COAGULACIÓN Y VAPORIZACIÓN EN CIRUGÍA GENERAL Y MICROCIRUGÍA. APARATO DE RAYOS LÁSER DE CO2 EN BASE RODABLE POTENCIA DE 20 A 150 W SOBRE TEJIDO OPERACIÓN CONTINUA Y PULSADA CON BRAZO ARTICULADO DE FIBRA DE CARBONO Y SISTEMA DE BALANCEO DEL BRAZO EN BASE A RESORTE ENFRIAMIENTO POR AIRE. CAPACIDAD PARA ALMACENAMIENTO DE PROTOCOLOS."
    },
    {
      "clave": "53101-1717",
      "monto": 2017019.14,
      "partidas": 2,
      "descripcion": "531.619.0411 MONITOR DE SIGNOS VITALES PARA EL TRASLADO DEL PACIENTE. EQUIPO PORTATIL NO INVASIVO QUE REGISTRA EN PANTALLA LAS CONSTANTES VITALES DEL PACIENTE CON FINES DIAGNOSTICOS Y TERAPEUTICOS. CON LAS SIGUIENTES CARACTERISTICAS SELECCIONABLES DE ACUERDO A LAS NECESIDADES DE LAS UNIDADES MEDICAS: MONITOR. CON ASA PARA TRANSPORTE Y SISTEMA PARA SUJECION A RIELES LATERALES DE CAMILLA. CONTROLADO POR MICROPROCESADOR. PARA PRESENTACION SIMULTANEA DE CURVAS FISIOLOGICAS E INFORMACION NUMERICA PARA LOS SIGUIENTES PARAMETROS DE ACUERDO A LAS NECESIDADES DE LAS UNIDADES MEDICAS: OXIMETRIA DE PULSO ELECTROCARDIOGRAMA RESPIRACION POR IMPEDANCIA. DESPLIEGUE NUMERICO SIMULTANEO DE: FRECUENCIA CARDIACA PRESION ARTERIAL NO INVASIVA PROGRAMACION DE LA TOMA DE PRESION A DIFERENTES INTERVALOS DE TIEMPO: SISTOLICA DIASTOLICA TEMPERATURA EN AL MENOS UN CANAL FRECUENCIA RESPIRATORIA CON PRESENTACION DE SU CURVA OXIMETRIA DE PULSO Y FRECUENCIA DEL PULSO. ALMACENAMIENTO DE TENDENCIAS GRAFICAS Y NUMERICAS. USO ADULTO Y PEDIATRICO. BATERIA INTERNA RECARGABLE. CARGADOR. INDICADOR LUMINOSO O EN PANTALLA DE BAJA BATERIA. ALARMAS AUDIBLES Y VISIBLES CON FUNCION QUE PERMITA REVISAR Y MODIFICAR LOS LIMITES DE ALARMA DE LOS SIGUIENTES PARAMETROS: SATURACION DE OXIGENO FRECUENCIA CARDIACA PRESION ARTERIAL NO INVASIVA TEMPERATURA FRECUENCIA RESPIRATORIA Y ALARMA DE APNEA. CON SILENCIADOR DE ALARMAS. MANUAL Y MENSAJES EN ESPAÑOL. TECLADO DEL EQUIPO EN ESPAÑOL Y CON SIMBOLOGIA ACEPTADA INTERNACIONALMENTE. PESO INCLUYENDO LA BATERIA Y EL CARGADOR."
    }
  ],
  "recentProcedures": [
    {
      "numero": "aa-51-gyn-051gyn020-t-7-2026",
      "titulo": "ADQUISICION DE CAMAS ELECTRICAS",
      "estatus": "ADJUDICADO",
      "fecha_publicacion": "2026-05-15T13:35:59+00:00"
    },
    {
      "numero": "la-51-gyn-051gyn020-t-5-2026",
      "titulo": "ADQUISICIÓN DE CAMAS ELÉCTRICAS HOSPITALARIAS PARA DIVERSAS UNIDADES MÉDICAS",
      "estatus": "ADJUDICADO",
      "fecha_publicacion": "2026-04-08T13:06:52+00:00"
    },
    {
      "numero": "aa-47-ayo-047ayo937-n-73-2025",
      "titulo": "SERVICIO INTEGRAL DE TRASPLANTE",
      "estatus": "ADJUDICADO",
      "fecha_publicacion": "2025-10-28T15:02:26+00:00"
    },
    {
      "numero": "la-51-gyn-051gyn020-t-10-2025",
      "titulo": "“ADQUISICIÓN DE EQUIPAMIENTO DEL CENTRO MÉDICO NACIONAL 20  DE NOVIEMBRE”",
      "estatus": "ADJUDICADO PARCIAL",
      "fecha_publicacion": "2025-08-15T20:50:29+00:00"
    },
    {
      "numero": "la-51-gyn-051gyn020-t-9-2025",
      "titulo": "“ADQUISICIÓN DE EQUIPO MÉDICO PARA DIVERSAS UNIDADES MÉDICAS”",
      "estatus": "ADJUDICADO PARCIAL",
      "fecha_publicacion": "2025-08-15T20:22:40+00:00"
    }
  ],
  "amountByYear": {
    "2025": {
      "monto": 41987210.61,
      "contratos": 3
    },
    "2026": {
      "monto": 132029835.37,
      "contratos": 2
    }
  },
  "firstContractAt": "2025-10-02T00:00:00.000Z",
  "lastContractAt": "2026-05-15T00:00:00.000Z",
  "entityType": "moral",
  "distinctMoralRfcs": 1,
  "isAmbiguous": false,
  "isIndexable": true,
  "noindexReason": null,
  "contentHash": "af827fc5a0726089c588313bab69e15d69f7faaf5c05a01ee856b9acf3a385a6",
  "refreshedAt": "2026-08-18T04:39:58.645Z",
  "snapshot": {
    "snapshot_id": "af827fc5a0726089c588313bab69e15d69f7faaf5c05a01ee856b9acf3a385a6",
    "as_of": "2026-08-18T04:39:58.645Z",
    "procedures": {
      "total": 5,
      "shown": 5,
      "complete": true
    }
  }
}