{
  "html_url": "https://licitia.com.mx/proveedor/servicio-y-soporte-biomedico",
  "canonical": "https://licitia.com.mx/proveedor/servicio-y-soporte-biomedico",
  "id": "1075957",
  "slug": "servicio-y-soporte-biomedico",
  "displayName": "SERVICIO Y SOPORTE BIOMEDICO SA DE CV",
  "normalizedName": "servicio-y-soporte-biomedico",
  "aliasCount": 1,
  "totalContracts": 78,
  "totalProcedures": 74,
  "totalAwardedAmount": "117177024.53",
  "minAmount": "99.64",
  "maxAmount": "16217043.6",
  "medianAmount": "317435.34",
  "suspectContracts": 0,
  "foreignContracts": 0,
  "foreignTotals": null,
  "distinctBuyers": 2,
  "distinctStates": 20,
  "distinctCucop": 31,
  "topBuyers": [
    {
      "slug": "imss",
      "monto": 116664002.93,
      "nombre": "INSTITUTO MEXICANO DEL SEGURO SOCIAL",
      "contratos": 75
    },
    {
      "slug": "sedena",
      "monto": 513021.6,
      "nombre": "SECRETARIA DE LA DEFENSA NACIONAL",
      "contratos": 3
    }
  ],
  "topCucop": [
    {
      "clave": "35401-0003",
      "monto": 79343418.6,
      "partidas": 300,
      "descripcion": "SERVICIOS DE MANTENIMIENTO DE EQUIPO E INSTRUMENTAL MEDICO"
    },
    {
      "clave": "35401-0001",
      "monto": 18303552.08,
      "partidas": 3,
      "descripcion": "SERVICIOS DE INSTALACION DE EQUIPO E INSTRUMENTAL MEDICO"
    },
    {
      "clave": "35102-0003",
      "monto": 5967021.44,
      "partidas": 1,
      "descripcion": "MANTENIMIENTO DE INMUEBLES PARA LA PRESTACION DE SERVICIOS PUBLICOS"
    },
    {
      "clave": "35401-0002",
      "monto": 5862385.15,
      "partidas": 12,
      "descripcion": "SERVICIOS DE REPARACION DE EQUIPO E INSTRUMENTAL MEDICO"
    },
    {
      "clave": "33901-0032",
      "monto": 3050364.7,
      "partidas": 1,
      "descripcion": "SUBCONTRATACIÓN DE SERVICIOS CON TERCEROS"
    },
    {
      "clave": "25401-0607",
      "monto": 748108.68,
      "partidas": 14,
      "descripcion": "INSUMO PARA MONITOREO DE CONSTANTES VITALES"
    },
    {
      "clave": "25401-0605",
      "monto": 721204.48,
      "partidas": 12,
      "descripcion": "INSUMO QUIRURGICO"
    },
    {
      "clave": "29501-0008",
      "monto": 513021.6,
      "partidas": 10,
      "descripcion": "REFACCIONES MENORES DE EQUIPO E INSTRUMENTAL MEDICO Y DE LABORATORIO"
    },
    {
      "clave": "25401-0088",
      "monto": 482767.64,
      "partidas": 1,
      "descripcion": "CAMPANA CON CIRCUITO INTEGRADO PARA HEMOFERESIS ADULTO"
    },
    {
      "clave": "53101-0335",
      "monto": 387440,
      "partidas": 1,
      "descripcion": "VENTILADOR TERAPIA RESPIRATORIA (EQUIPO MEDICO QUIRURGICO)"
    },
    {
      "clave": "29501-0005",
      "monto": 206022.65,
      "partidas": 16,
      "descripcion": "ACCESORIOS DE EQUIPO E INSTRUMENTAL MEDICO Y DE LABORATORIO"
    },
    {
      "clave": "25401-0618",
      "monto": 163536.8,
      "partidas": 1,
      "descripcion": "OXISENSOR NEONATAL"
    },
    {
      "clave": "29801-0031",
      "monto": 129920,
      "partidas": 1,
      "descripcion": "VALVULA"
    },
    {
      "clave": "29501-0009",
      "monto": 126774.66,
      "partidas": 4,
      "descripcion": "ACCESORIOS MENORES DE EQUIPO E INSTRUMENTAL MEDICO Y DE LABORATORIO"
    },
    {
      "clave": "53101-1822",
      "monto": 121990.05,
      "partidas": 1,
      "descripcion": "531.829.0899 SISTEMA DE VENTILADORES. INDICADO PARA PROPORCIONAR SOPORTE RESPIRATORIO, MONITORIZACION Y TRATAMIENTO PEDIATRICOS Y ADULTOS. EL SISTEMA DE VENTILACION CONSTA DE: INTERFAZ DE USUARIO: PERMITE AJUSTAR LOS REGIMENES DE VENTILACION, MOSTRAR DATOS E INDICAR ALARMAS. UNIDAD DE PACIENTE: PERMITE MEZCLAR LOS GASES Y CONTROLAR EL SUMINISTRO DE GAS. CIRCUITO DEL PACIENTE: PERMITE SUMINISTRAR E INTERCAMBIAR GASES. PANTALLA INTERCONSTRUIDA: TIPO LCD, TFT-LCD O TFT O LED. A COLOR. TAMAÑO MINIMO DE 10\"\" (25 CM) O MAYOR CONFIGURABLE POR EL USUARIO. CARACTERISTICAS GENERALES: MEZCLADOR DE AIRE-OXIGENO INTERNO. MONITOREO FIO2 INTERNO O INTEGRADO. SENSOR DE FLUJO REUSABLE. CON SISTEMA DE COMPENSACION DE FUGAS. HUMIDIFICADOR SERVOCONTROLADO PARA USO CON CALENTADOR DE TUBO SENCILLO O DUAL; CON SENSOR DE TEMPERATURA SENCILLO O DUAL DE SOPORTE AL VENTILADOR. TODO EL SISTEMA EN IDIOMA ESPAÑOL. TECLADO SENSIBLE AL TACTO O DE MEMBRANA; O PERILLA SELECTORA PARA EL AJUSTE DE LOS VALORES DE TODOS LOS PARAMETROS DE CONTROL. CONTROL DE PARAMETROS DE: VOLUMEN CORRIENTE QUE CUBRA EL RANGO DE 20 A 2000 ML. FLUJO INSPIRATORIO O FLUJO ADAPTATIVO QUE CUBRA EL RANGO DE 0 A 240 L/MIN. PRESION INSPIRATORIA QUE CUBRA EL RANGO DE 5 A 60 CMH2O. FRECUENCIA RESPIRATORIA QUE CUBRA EL RANGO DE 4 A 150 RESPIRACIONES POR MINUTO. TIEMPO INSPIRATORIO QUE CUBRA EL RANGO DE 0.1 A 5 SEGUNDOS. FIO2 QUE CUBRA EL RANGO DE 21 A 100 %. PEEP/CPAP QUE CUBRA EL RANGO DE 0 A 50 CMH2O. PRESION SOPORTE (PSV), PRESION ASISTIDA O ASB QUE CUBRA EL RANGO DE 0 A 99 CMH2O. CON OPCION MESETA INSPIRATORIA, DE PLATEU O PAUSA INSPIRATORIA. CON OPCION DE PAUSA ESPIRATORIA DE 0 A 1.5 SEGUNDOS O MAYOR. CON OPCION A RESPIRACION MANUAL. SALIDA PARA NEBULIZADOR O NEBULIZADOR SINCRONICO, ULTRASONICO O ELECTRICO. MECANISMO DE DISPARO O TRIGGER POR FLUJO Y/O POR PRESION. SENSIBILIDAD ESPIRATORIA O TERMINACION DE LA FASE INSPIRATORIA. BIAS FLOW, FLUJO BASE, CONTINUO O CPAP. AJUSTE DE RAMPA DE PRESION, RISE TIME, RETARDO INSPIRATORIO, RAMPA, O INCREMENTO DE LA PENDIENTE DE PRESION. MODOS VENTILATORIOS: VENTILACION ASISTO CONTROLADA Y SIMV CONTROLADA POR VOLUMEN. VENTILACION ASISTO CONTROLADA Y SIMV CONTROLADA POR PRESION. PRESION SOPORTE (PSV) O PRESION ASISTIDA. BIVENT/APRV, CPAP O ESPONTANEO CON LINEA DE BASE ELEVADA. RESPALDO EN CASO DE APNEA DE ACUERDO AL MODO VENTILATORIO, POR VOLUMEN O PRESION. VENTILACION NO INVASIVA. TERAPIA DE ALTO FLUJO PARAMETROS MONITORIZADOS: PRESION INSPIRATORIA PICO O MAXIMA. PRESION MEDIA EN VIAS AEREAS. PRESION DE MESETA O PLATEAU. PEEP. FRECUENCIA RESPIRATORIA. VOLUMEN MINUTO. RELACION I:E. VOLUMEN CORRIENTE EXPIRADO. FIO2. INDICADOR DE HORAS DE USO. INDICADOR DE BATERIA DE RESPALDO EN USO. CALCULO DE DISTENSIBILIDAD O COMPLIANCE. CALCULO DE LA RESISTENCIA. DESPLIEGUE DE AL MENOS 2 DE LAS 3 CURVAS DE VENTILACION DE FORMA SIMULTANEA: VOLUMEN-TIEMPO; FLUJO-TIEMPO; PRESION- TIEMPO. DESPLIEGUE DE AL MENOS 2 LAZOS O LOOPS. CAPACIDAD DE ALMACENAR EVENTOS RELACIONADOS CON LOS PARAMETROS VENTILATORIOS SELECCIONADOS Y TENDENCIAS AL MENOS DE 24 HORAS. MEDICION DE AUTOPEEP O PEEPTOTAL. PRESION DE IMPULSO. ALARMAS: AUDIBLES Y VISUALES, AMBAS PRIORIZADAS EN TRES NIVELES. PRESION INSPIRATORIA ALTA Y BAJA. PEEP BAJO O DESCONEXION DEL PACIENTE. APNEA. VOLUMEN MINUTO Y/O CORRIENTE (ALTO Y BAJO). FRECUENCIA RESPIRATORIA ALTA. FIO2 ALTA Y BAJA. BAJA PRESION DEL SUMINISTRO DE GASES. FALTA DE ALIMENTACION ELECTRICA. BATERIA BAJA. VENTILADOR INOPERANTE O FALLA DEL VENTILADOR. SILENCIO DE ALARMA. ACCESORIOS INCLUIDOS: BRAZO SOPORTE PARA CIRCUITO DE PACIENTE. BASE RODABLE PARA EL EQUIPO CON SISTEMA DE FRENO EN AL MENOS DOS RUEDAS. BATERIA DE RESPALDO INTERNA, CON DURACION DE 60 MINUTOS DE RESPALDO COMO MINIMO. MANGUERAS PARA SUMINISTRO DE GAS DE ACUERDO AL CODIGO AMERICANO DE COLORES: O2 - VERDE, AIRE - AMARILLO; PUDIENDO SE AIRE Y OXIGENO O SOLO OXIGENO, SEGUN MARCA Y MODELO. REGULADORES DE PRESION INTEGRADOS PARA EL SUMINISTRO DE GASES. DOS CIRCUITOS DE PACIENTE ADULTO REUSABLES LIBR"
    },
    {
      "clave": "22301-0110",
      "monto": 115072,
      "partidas": 1,
      "descripcion": "FILTROS DESECHABLES"
    },
    {
      "clave": "25501-0020",
      "monto": 114255.36,
      "partidas": 3,
      "descripcion": "HOJA LARINGOSCOPIO"
    },
    {
      "clave": "25401-0571",
      "monto": 110200,
      "partidas": 1,
      "descripcion": "BALON PARA ANGIOGRAFIA"
    },
    {
      "clave": "25401-8127",
      "monto": 109583.57,
      "partidas": 4,
      "descripcion": "SENSOR DE OXIMETRO"
    },
    {
      "clave": "24601-0019",
      "monto": 97980.79,
      "partidas": 1,
      "descripcion": "CABLES"
    }
  ],
  "recentProcedures": [
    {
      "numero": "la-50-gyr-050gyr002-n-161-2026",
      "titulo": "SERVICIO DE MANTENIMIENTO PREVENTIVO Y CORRECTIVO A EQUIPOS CUNA DE CALOR RADIAN",
      "estatus": "ADJUDICADO",
      "fecha_publicacion": "2026-07-17T17:20:56+00:00"
    },
    {
      "numero": "ia-50-gyr-050gyr063-t-55-2026",
      "titulo": "ADQUISICIÓN DE CONSUMIBLES DE EQUIPO MÉDICO",
      "estatus": "ADJUDICADO PARCIAL",
      "fecha_publicacion": "2026-06-02T17:42:54+00:00"
    },
    {
      "numero": "la-50-gyr-050gyr008-t-54-2026",
      "titulo": "LA-T54-2026 ADQUISICION DE CONSUMIBLES PARA EQUIPO MEDICO",
      "estatus": "ADJUDICADO PARCIAL",
      "fecha_publicacion": "2026-05-07T08:25:51+00:00"
    },
    {
      "numero": "la-50-gyr-050gyr010-t-51-2026",
      "titulo": "LA-50-GYR-050GYR010-T-51-2026 ADQUISICION DE CONSUMIBLES Y ACCESORIO  MÉDICO.",
      "estatus": "ADJUDICADO PARCIAL",
      "fecha_publicacion": "2026-05-05T14:43:37+00:00"
    },
    {
      "numero": "la-07-110-007000999-t-368-2026",
      "titulo": "ADQUISICION DE REFACCIONES PARA MANTENIMIENTO PREVENTIVO Y/O CORRECTIVO A EQUIPO",
      "estatus": "ADJUDICADO PARCIAL",
      "fecha_publicacion": "2026-04-30T19:16:42+00:00"
    },
    {
      "numero": "aa-50-gyr-050gyr037-n-61-2026",
      "titulo": "MANTENIMIENTO A MONITORES DE SIGNOS VITALES PARA EL EJERCICIO 2026",
      "estatus": "ADJUDICADO",
      "fecha_publicacion": "2026-04-23T16:26:51+00:00"
    },
    {
      "numero": "ia-50-gyr-050gyr046-t-21-2026",
      "titulo": "CONSUMIBLES EQUIPO MEDICO 2026 REQ A26011, 12 Y 14",
      "estatus": "ADJUDICADO PARCIAL",
      "fecha_publicacion": "2026-04-21T16:00:18+00:00"
    },
    {
      "numero": "aa-50-gyr-050gyr027-n-79-2026",
      "titulo": "SERVICIOS DE MANTENIMIENTO PREVENTIVO Y CORRECTIVO A TODOS /ADJ 20 26 BIS",
      "estatus": "ADJUDICADO",
      "fecha_publicacion": "2026-03-18T18:16:11+00:00"
    },
    {
      "numero": "la-50-gyr-050gyr022-t-72-2026",
      "titulo": "ADQUISICIÓN DE CONSUMIBLES, SENSORES Y MANGOS DE LARINGOSCOPIOS",
      "estatus": "ADJUDICADO PARCIAL",
      "fecha_publicacion": "2026-02-17T15:37:51+00:00"
    },
    {
      "numero": "la-50-gyr-050gyr055-t-34-2026",
      "titulo": "ADQUISICIÓN DE LOS GRUPOS DE SUMINISTRO 379 CONSUMIBLES DE EQUIPOS MÉDICOS Y DE",
      "estatus": "ADJUDICADO PARCIAL",
      "fecha_publicacion": "2026-02-10T16:57:50+00:00"
    },
    {
      "numero": "la-50-gyr-050gyr067-n-20-2026",
      "titulo": "MANTENIMIENTO PREVENTIVO Y CORRECTIVO A EQUIPO MÉDICO (2DO BLOQUE)",
      "estatus": "ADJUDICADO PARCIAL",
      "fecha_publicacion": "2026-02-10T13:16:41+00:00"
    },
    {
      "numero": "aa-50-gyr-050gyr037-n-151-2025",
      "titulo": "MANTENIMIENTO A EQUIPO MEDICO EJERCICIO 2025",
      "estatus": "ADJUDICADO",
      "fecha_publicacion": "2025-12-10T15:16:08+00:00"
    },
    {
      "numero": "la-50-gyr-050gyr004-n-423-2025",
      "titulo": "SERV DE MPC CON REFACCIONES A EQUIPO MEDICO Y MOBILIARIO EJERCICIO 2026.",
      "estatus": "ADJUDICADO",
      "fecha_publicacion": "2025-11-25T14:33:29+00:00"
    },
    {
      "numero": "la-50-gyr-050gyr015-n-33-2026",
      "titulo": "SERVICIO DE MANTENIMIENTO PREVENTIVO Y CORRECTIVO A EQUIPOS MÉDICOS",
      "estatus": "ADJUDICADO PARCIAL",
      "fecha_publicacion": "2025-11-20T15:18:33+00:00"
    },
    {
      "numero": "la-50-gyr-050gyr015-t-166-2025",
      "titulo": "ADQ CONS EQ MED, MOB, INSTRUMENTAL, GRUPO 379, 513, 526, 531, 535, 537 Y 564,",
      "estatus": "ADJUDICADO PARCIAL",
      "fecha_publicacion": "2025-10-02T15:49:08+00:00"
    }
  ],
  "amountByYear": {
    "2023": {
      "monto": 17247333.54,
      "contratos": 23
    },
    "2024": {
      "monto": 24497654.39,
      "contratos": 19
    },
    "2025": {
      "monto": 49586010.72,
      "contratos": 21
    },
    "2026": {
      "monto": 25846025.88,
      "contratos": 15
    }
  },
  "firstContractAt": "2023-01-01T00:00:00.000Z",
  "lastContractAt": "2026-08-14T00:00:00.000Z",
  "entityType": "moral",
  "distinctMoralRfcs": 0,
  "isAmbiguous": false,
  "isIndexable": true,
  "noindexReason": null,
  "contentHash": "81e3351d26578ecc7b6010e639e4320ed885c967b1bbbc23ea9c351caae01453",
  "refreshedAt": "2026-08-18T04:39:58.645Z",
  "snapshot": {
    "snapshot_id": "81e3351d26578ecc7b6010e639e4320ed885c967b1bbbc23ea9c351caae01453",
    "as_of": "2026-08-18T04:39:58.645Z",
    "procedures": {
      "total": 74,
      "shown": 15,
      "complete": false
    }
  }
}